LINKB-OPT-FDDI-MIB-1-1-2 DEFINITIONS ::= BEGIN
IMPORTS
enterprises, Counter FROM RFC1155-SMI
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
FddiTimeNano,
FddiSMTStationIdType,
fddimibSMTStationId,
fddimibSMTCFState,
fddimibSMTPeerWrapFlag,
fddimibMACSMTAddress,
fddimibMACDaFlag,
fddimibMACUnaDaFlag,
fddimibMACFrameErrorFlag,
fddimibMACFrameCts,
fddimibMACErrorCts,
fddimibMACLostCts,
fddimibMACFrameErrorRatio,
fddimibMACNotCopiedCts,
fddimibMACCopiedCts,
fddimibMACNotCopiedRatio,
fddimibMACNotCopiedFlag,
fddimibMACUpstreamNbr,
fddimibMACOldUpstreamNbr,
fddimibMACDownstreamNbr,
fddimibMACOldDownstreamNbr,
fddimibMACCurrentPath,
fddimibMACAvailablePaths,
fddimibMACRequestedPaths,
fddimibPORTLerCutoff,
fddimibPORTLerAlarm,
fddimibPORTLerEstimate,
fddimibPORTLemRejectCts,
fddimibPORTLemCts,
fddimibPORTLerFlag,
fddimibPORTMyType,
fddimibPORTConnectState,
fddimibPORTNeighborType,
fddimibPORTPCWithhold,
fddimibPORTAvailablePaths,
fddimibPORTCurrentPath,
fddimibPORTRequestedPaths FROM DRAFT-FDDI-MIB-VER-3-2;
a3Com OBJECT IDENTIFIER ::= { enterprises 43 }
lb3gh OBJECT IDENTIFIER ::= { a3Com 7 }
lb3ghOptFddi OBJECT IDENTIFIER ::= { lb3gh 2 }
lbOptSMT OBJECT IDENTIFIER ::= { lb3ghOptFddi 1 }
lbOptMAC OBJECT IDENTIFIER ::= { lb3ghOptFddi 2 }
lbOptPATH OBJECT IDENTIFIER ::= { lb3ghOptFddi 3 }
lbOptPORT OBJECT IDENTIFIER ::= { lb3ghOptFddi 4 }
lbOptSMTTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbOptSMTEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of optional SMT entries. The number of entries
shall not exceed the value of snmpFddiSMTNumber."
::= { lbOptSMT 1 }
lbOptSMTEntry OBJECT-TYPE
SYNTAX LbOptSMTEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An optional SMT entry containing information common to
a given optional SMT."
INDEX { lbOptSMTIndex }
::= { lbOptSMTTable 1 }
LbOptSMTEntry ::=
SEQUENCE {
lbOptSMTIndex
INTEGER,
lbOptSMTManufacturerOUI
OCTET STRING,
lbOptSMTManufacturerData
OCTET STRING,
lbOptSMTHoldState
INTEGER,
lbOptSMTSetCount
INTEGER,
lbOptSMTLastSetStationId
FddiSMTStationIdType
}
lbOptSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber. The
value for each SMT must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { lbOptSMTEntry 1 }
lbOptSMTManufacturerOUI OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The three octets of manufacturer data which make
up the manufacturerOUI component."
REFERENCE
"ANSI { fddiSMT 16 }"
::= { lbOptSMTEntry 2 }
lbOptSMTManufacturerData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (29))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 29 octets of manufacturer data which make up the
manufacturerData component."
REFERENCE
"ANSI { fddiSMT 16 }"
::= { lbOptSMTEntry 3 }
lbOptSMTHoldState OBJECT-TYPE
SYNTAX INTEGER {
not-implemented(1), not-holding(2),
holding-prm(3), holding-sec(4) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable indicates the current state of the
Hold function. The value 'not-holding' is the
default and initial value. The value must be set
to 'not-holding' as part of Active_Actions and
when the conditions causing 'holding-prm' or
'holding-sec' are no longer true. The value
'holding-prm' must be set when the condition
(notTR_Flag & not RE_Flag & (PC_LS=QLS | LEM_Fail
| TNE>NS_Max | (not LS_Flag & TPC > T_Out))) is
satisfied in state PC8:ACTIVE for the A Port. The
value 'holding-sec' must be set when the condition
(notTR_Flag & not RE_Flag & (PC_LS=QLS | LEM_Fail
| TNE>NS_Max | (not LS_Flag & TPC > T_Out))) is
satisfied in state PC8:ACTIVE for the B Port."
REFERENCE
"ANSI { fddiSMT 43 }"
::= { lbOptSMTEntry 4 }
lbOptSMTSetCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is composed of a count incremented
in response to a Set operation on the MIB, and the
time of the change, however only the count is
reported here (refer to ANSI SMT 8.4.1)."
REFERENCE
"ANSI { fddiSMT 53 }"
::= { lbOptSMTEntry 5 }
lbOptSMTLastSetStationId OBJECT-TYPE
SYNTAX FddiSMTStationIdType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Station ID of the station that effected the last
change in the FDDI MIB."
REFERENCE
"ANSI { fddiSMT 54 }"
::= { lbOptSMTEntry 6 }
lbOptMACBridgeFunctionTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbOptMACBridgeFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of MAC bridge function entries."
::= { lbOptMAC 1 }
lbOptMACBridgeFunctionEntry OBJECT-TYPE
SYNTAX LbOptMACBridgeFunctionEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Bridge function information for a given MAC
within a given SMT."
INDEX { lbOptMACBridgeFunctionSMTIndex,
lbOptMACBridgeFunctionMACIndex }
::= { lbOptMACBridgeFunctionTable 1 }
LbOptMACBridgeFunctionEntry ::=
SEQUENCE {
lbOptMACBridgeFunctionSMTIndex
INTEGER,
lbOptMACBridgeFunctionMACIndex
INTEGER,
lbOptMACBridgeFunctions
INTEGER
}
lbOptMACBridgeFunctionSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber. The
value for each SMT must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { lbOptMACBridgeFunctionEntry 1 }
lbOptMACBridgeFunctionMACIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index variable for uniquely identifying the MAC
object instances."
REFERENCE
"ANSI { fddiMAC 34 }"
::= { lbOptMACBridgeFunctionEntry 2 }
lbOptMACBridgeFunctions OBJECT-TYPE
SYNTAX INTEGER (-1..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the MAC's optional bridging functions.
The Value -1 is used to indicate that bridging is
not supported by this MAC.
The value is a sum. This value initially takes
the value zero, then for each function present, 2
raised to a power is added to the sum. The powers
are according to the following table:
Function Power
tb 0 -- Transparent bridging active
sr 1 -- Src routing active
srt 2 -- Src routing transparent active
"
REFERENCE
"ANSI { fddiMAC 12 }"
::= { lbOptMACBridgeFunctionEntry 3 }
lbOptMACTPriTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbOptMACTPriEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of MAC T-Pri entries."
::= { lbOptMAC 2 }
lbOptMACTPriEntry OBJECT-TYPE
SYNTAX LbOptMACTPriEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A collection of T-Pri information for a given MAC within
a given SMT."
INDEX { lbOptMACTPriSMTIndex, lbOptMACTPriMACIndex }
::= { lbOptMACTPriTable 1 }
LbOptMACTPriEntry ::=
SEQUENCE {
lbOptMACTPriSMTIndex
INTEGER,
lbOptMACTPriMACIndex
INTEGER,
lbOptMACTPri0
FddiTimeNano,
lbOptMACTPri1
FddiTimeNano,
lbOptMACTPri2
FddiTimeNano,
lbOptMACTPri3
FddiTimeNano,
lbOptMACTPri4
FddiTimeNano,
lbOptMACTPri5
FddiTimeNano,
lbOptMACTPri6
FddiTimeNano
}
lbOptMACTPriSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber. The
value for each SMT must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { lbOptMACTPriEntry 1 }
lbOptMACTPriMACIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index variable for uniquely identifying the MAC
object instances."
REFERENCE
"ANSI { fddiMAC 34 }"
::= { lbOptMACTPriEntry 2 }
lbOptMACTPri0 OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute is an unsigned twos-complement T_pri
threshold as described in the MAC standard converted
to non-twos-complement form and reported in 1 ns units."
REFERENCE
"ANSI { fddiMAC 56 }"
::= { lbOptMACTPriEntry 3 }
lbOptMACTPri1 OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute is an unsigned twos-complement T_pri
threshold as described in the MAC standard converted
to non-twos-complement form and reported in 1 ns units."
REFERENCE
"ANSI { fddiMAC 57 }"
::= { lbOptMACTPriEntry 4 }
lbOptMACTPri2 OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute is an unsigned twos-complement T_pri
threshold as described in the MAC standard converted
to non-twos-complement form and reported in 1 ns units."
REFERENCE
"ANSI { fddiMAC 58 }"
::= { lbOptMACTPriEntry 5 }
lbOptMACTPri3 OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute is an unsigned twos-complement T_pri
threshold as described in the MAC standard converted
to non-twos-complement form and reported in 1 ns units."
REFERENCE
"ANSI { fddiMAC 59 }"
::= { lbOptMACTPriEntry 6 }
lbOptMACTPri4 OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute is an unsigned twos-complement T_pri
threshold as described in the MAC standard converted
to non-twos-complement form and reported in 1 ns units."
REFERENCE
"ANSI { fddiMAC 60 }"
::= { lbOptMACTPriEntry 7 }
lbOptMACTPri5 OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute is an unsigned twos-complement T_pri
threshold as described in the MAC standard converted
to non-twos-complement form and reported in 1 ns units."
REFERENCE
"ANSI { fddiMAC 61 }"
::= { lbOptMACTPriEntry 8 }
lbOptMACTPri6 OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute is an unsigned twos-complement T_pri
threshold as described in the MAC standard converted
to non-twos-complement form and reported in 1 ns units."
REFERENCE
"ANSI { fddiMAC 62 }"
::= { lbOptMACTPriEntry 9 }
lbOptPATHRingTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbOptPATHRingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PATH ring entries."
::= { lbOptPATH 1 }
lbOptPATHRingEntry OBJECT-TYPE
SYNTAX LbOptPATHRingEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Ring latency, trace status, and T-Rmode information for a
given PATH within a given SMT."
INDEX { lbOptPATHRingSMTIndex, lbOptPATHRingPATHIndex }
::= { lbOptPATHRingTable 1 }
LbOptPATHRingEntry ::=
SEQUENCE {
lbOptPATHRingSMTIndex
INTEGER,
lbOptPATHRingPATHIndex
INTEGER,
lbOptPATHRingLatency
FddiTimeNano,
lbOptPATHTraceStatus
INTEGER,
lbOptPATHT-Rmode
FddiTimeNano
}
lbOptPATHRingSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber. The
value for each SMT must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { lbOptPATHRingEntry 1 }
lbOptPATHRingPATHIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index variable for uniquely identifying the
primary, secondary and local PATH object
instances. Local PATH object instances are
represented with integer values 3 to 255."
REFERENCE
"ANSI { fddiPATH 11 }"
::= { lbOptPATHRingEntry 2 }
lbOptPATHRingLatency OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Gives the total accumulated latency of the ring
associated with this path. May be measured directly
by the station or calculated by a management station.
Values of this object are reported in 1 ns units."
REFERENCE
"ANSI { fddiPATH 13 }"
::= { lbOptPATHRingEntry 3 }
lbOptPATHTraceStatus OBJECT-TYPE
SYNTAX INTEGER (0..15)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the current trace status of
the path.
The value is a sum which represents all of the trace
status information which applies. This value initially
takes the value zero, then for each condition which
applies, 2 raised to a power is added to the sum. the
powers are according to the following table:
TraceStatus Power
traceinitiated 0
tracepropragated 1
traceterminated 2
tracetimeout 3"
REFERENCE
"ANSI { fddiPATH 14 }"
::= { lbOptPATHRingEntry 4 }
lbOptPATHT-Rmode OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used by RMT to limit the duration of restricted dialogs
on a path. This object is reported in 1 ns units."
REFERENCE
"ANSI { fddiPATH 19 }"
::= { lbOptPATHRingEntry 5 }
lbOptPATHSbaTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbOptPATHSbaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PATH Sba entries."
::= { lbOptPATH 2 }
lbOptPATHSbaEntry OBJECT-TYPE
SYNTAX LbOptPATHSbaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Sba information for a given PATH within a given SMT."
INDEX { lbOptPATHSbaSMTIndex, lbOptPATHSbaPATHIndex }
::= { lbOptPATHSbaTable 1 }
LbOptPATHSbaEntry ::=
SEQUENCE {
lbOptPATHSbaSMTIndex
INTEGER,
lbOptPATHSbaPATHIndex
INTEGER,
lbOptPATHSbaPayload
INTEGER,
lbOptPATHSbaOverhead
INTEGER,
lbOptPATHSbaAvailable
INTEGER
}
lbOptPATHSbaSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber. The
value for each SMT must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { lbOptPATHSbaEntry 1 }
lbOptPATHSbaPATHIndex OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index variable for uniquely identifying the
primary, secondary and local PATH object
instances. Local PATH object instances are
represented with integer values 3 to 255."
REFERENCE
"ANSI { fddiPATH 11 }"
::= { lbOptPATHSbaEntry 2 }
lbOptPATHSbaPayload OBJECT-TYPE
SYNTAX INTEGER (0..1562)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The payload portion of the Synchronous Bandwidth
Allocation for thi path. This value represents the
maximum number of bytes of data allocated for
transmission per 125 microseconds."
REFERENCE
"ANSI { fddiPATH 15 }"
::= { lbOptPATHSbaEntry 3 }
lbOptPATHSbaOverhead OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The overhead portion of the Synchronous Bandwith
Allocation for this path. This value repersents the
maximum number of bytes overhead (token capture, frame
header, etc.) used pre negotiated Target Token Rotation
Time (T_neg)."
REFERENCE
"ANSI { fddiPATH 16 }"
::= { lbOptPATHSbaEntry 4 }
lbOptPATHSbaAvailable OBJECT-TYPE
SYNTAX INTEGER (0..12500000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value is the maximum Synchronous Bandwith available
for a path in bytes per second."
REFERENCE
"ANSI { fddiPATH 20 }"
::= { lbOptPATHSbaEntry 5 }
lbOptPORTTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbOptPORTEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of optional PORT entries."
::= { lbOptPORT 1 }
lbOptPORTEntry OBJECT-TYPE
SYNTAX LbOptPORTEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"MAC loop time and EB error count information for a
given PORT within a given SMT."
INDEX { lbOptPORTSMTIndex, lbOptPORTIndex }
::= { lbOptPORTTable 1 }
LbOptPORTEntry ::=
SEQUENCE {
lbOptPORTSMTIndex
INTEGER,
lbOptPORTIndex
INTEGER,
lbOptPORTMACLoopTime
FddiTimeNano,
lbOptPORTEBErrorCt
Counter
}
lbOptPORTSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber. The
value for each SMT must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { lbOptPORTEntry 1 }
lbOptPORTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index variable for uniquely identifying the PORT
object instances."
REFERENCE
"ANSI { fddiPORT 29 }"
::= { lbOptPORTEntry 2 }
lbOptPORTMACLoopTime OBJECT-TYPE
SYNTAX FddiTimeNano
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute controls the value used for T_Next(9)
(see 9.4.4.2.3). This object is reported in 1 ns
units."
REFERENCE
"ANSI { fddiPORT 21 }"
::= { lbOptPORTEntry 3 }
lbOptPORTEBErrorCt OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A count that should as closely as possible match the
times an Elasticity Buffer Error has occurred while in
active line state."
REFERENCE
"ANSI { fddiPORT 41 }"
::= { lbOptPORTEntry 4 }
lbOptPORTLSTable OBJECT-TYPE
SYNTAX SEQUENCE OF LbOptPORTLSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of optional PORT line state entries."
::= { lbOptPORT 2 }
lbOptPORTLSEntry OBJECT-TYPE
SYNTAX LbOptPORTLSEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Maintenance line state and PC line state information
for a given PORT within a given SMT."
INDEX { lbOptPORTLSSMTIndex, lbOptPORTLSPORTIndex }
::= { lbOptPORTLSTable 1 }
LbOptPORTLSEntry ::=
SEQUENCE {
lbOptPORTLSSMTIndex
INTEGER,
lbOptPORTLSPORTIndex
INTEGER,
lbOptPORTMaintLS
INTEGER,
lbOptPORTPCLS
INTEGER
}
lbOptPORTLSSMTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each SMT. Its value ranges
between 1 and the value of snmpFddiSMTNumber. The
value for each SMT must remain constant at least
from one re-initialization of the entity's network
management system to the next re-initialization."
::= { lbOptPORTLSEntry 1 }
lbOptPORTLSPORTIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index variable for uniquely identifying the PORT
object instances."
REFERENCE
"ANSI { fddiPORT 29 }"
::= { lbOptPORTLSEntry 2 }
lbOptPORTMaintLS OBJECT-TYPE
SYNTAX INTEGER {
quiet(1),
idle(2),
master(3),
halt(4),
receive-active(5),
receive-unknown(6),
receive-noise(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The PORT Maintenance Line State specifies the line state
(Maint_LS) to be transmitted when the PCM state machine
for the port is in state PC9 Maint."
REFERENCE
"ANSI { fddiPORT 31 }"
::= { lbOptPORTLSEntry 3 }
lbOptPORTPCLS OBJECT-TYPE
SYNTAX INTEGER {
quiet(1),
idle(2),
master(3),
halt(4),
receive-active(5),
receive-unknown(6),
receive-noise(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the line state (PC_LS) received
by the port."
REFERENCE
"ANSI { fddiPORT 34 }"
::= { lbOptPORTLSEntry 4 }
lbOptSMTHoldCondition TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
lbOptSMTHoldState }
DESCRIPTION
"Generated when fddiSMTHoldState (fddimibSMTHoldState)
assumes the state holding-prm or holding-sec. This
notification is a Condition in the Status Report
Protocol (see 7.2.7 and 8.3)."
REFERENCE
"ANSI { fddiSMT 71 }"
::= 1
lbOptSMTPeerWrapCondition TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibSMTCFState,
fddimibSMTPeerWrapFlag }
DESCRIPTION
"This condition is active when fddiSMTPeerWrapFlag
(fddimibSMTPeerWrapFlag) is set. This notification is
a Condition in the Status Report Protocol (see 7.2.7
and 8.3)."
REFERENCE
"ANSI { fddiSMT 72 }"
::= 2
lbOptMACDuplicateAddressCondition TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibMACSMTAddress,
fddimibMACUpstreamNbr,
fddimibMACDaFlag,
fddimibMACUnaDaFlag }
DESCRIPTION
"This condition is active when either fddiMACDA-Flag
(fddimibMACDaFlag) or fddiMACUNDA-Flag
(fddimibMACUnaDaFlag) is set. This event is handled
as a Condition in the Status Report Protocol (see 7.2.7
and 8.3)."
REFERENCE
"ANSI { fddiMAC 140 }"
::= 3
lbOptMACFrameErrorCondition TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibMACFrameErrorFlag,
fddimibMACFrameCts,
fddimibMACErrorCts,
fddimibMACLostCts,
fddimibMACFrameErrorRatio }
DESCRIPTION
"Generated when the fddiMACFrameErrorRatio
(fddimibMACFrameErrorRatio) is greater than or equal
to fddiMACFrameErrorThreshold
(fddimibMACFrameErrorThreshold). This event is handled
as a Condition in the Status Report Protocol (see 7.2.7
and 8.3)."
REFERENCE
"ANSI { fddiMAC 141 }"
::= 4
lbOptMACNotCopiedCondition TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibMACNotCopiedCts,
fddimibMACCopiedCts,
fddimibMACNotCopiedRatio,
fddimibMACNotCopiedFlag }
DESCRIPTION
"Generated when the fddiMACNotCopiedRatio
(fddimibMACNotCopiedRatio) is greater than or equal to
the fddiMACNotCopiedThreshold (lbOptMACNotCopiedThreshold).
This event is handled as a Condition in the Status Report
Protocol (see 7.2.7 and 8.3)."
REFERENCE
"ANSI { fddiMAC 142 }"
::= 5
lbOptMACNeighborChangeEvent TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibMACUpstreamNbr,
fddimibMACOldUpstreamNbr,
fddimibMACDownstreamNbr,
fddimibMACOldDownstreamNbr,
fddimibMACCurrentPath,
fddimibMACSMTAddress }
DESCRIPTION
"Generated when a change in a MAC's upstream neighbor
address or downstream neighbor address is detected.
(see 7.2.7 and 8.3)."
REFERENCE
"ANSI { fddiMAC 143 }"
::= 6
lbOptMACPathChangeEvent TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibMACAvailablePaths,
fddimibMACCurrentPath,
fddimibMACRequestedPaths }
DESCRIPTION
"This event is generated when the value of the
fddiMACCurrentPath (fddimibMACCurrentPath) changes.
This event shall be supressed if the value changes
from isolated to local or local to isolated (see
7.2.7 and 8.3)."
REFERENCE
"ANSI { fddiMAC 144 }"
::= 7
lbOptPORTLerCondition TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibPORTLerCutoff,
fddimibPORTLerAlarm,
fddimibPORTLerEstimate,
fddimibPORTLemRejectCts,
fddimibPORTLemCts,
fddimibPORTLerFlag }
DESCRIPTION
"This condition becomes active when the value of
fddiPORTLer-Estimate (fddimibPORTLerEstimate)
is less than or equal to fddiPORTLer-Alarm
(fddimibPORTLerAlarm). This will be reported
with the Status Report Frames (SRF) (see 7.2.7
and 8.3)."
REFERENCE
"ANSI { fddiPORT 80 }"
::= 8
lbOptPORTUndesiredConnAttemptEvent TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibPORTMyType,
fddimibPORTConnectState,
fddimibPORTNeighborType,
fddimibPORTPCWithhold }
DESCRIPTION
"Generated when an undesired connection attempt has
been made (see 5.2.4, 7.2.7, and 8.3)."
REFERENCE
"ANSI { fddiPORT 81 }"
::= 9
lbOptPORTEBErrorCondition TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
lbOptPORTEBErrorCt }
DESCRIPTION
"Generated when the Elasticity Buffer Error-Ct
(lbOptPORTEBErrorCt) increments. This is handled
as a condition in the Status Report Protocol. It
is generated when an increment occurs in the
station's sampling period (see 7.2.7 and 8.3)."
REFERENCE
"ANSI { fddiPORT 82 }"
::= 10
lbOptPORTPathChangeEvent TRAP-TYPE
ENTERPRISE lb3ghOptFddi
VARIABLES { fddimibSMTStationId,
fddimibPORTAvailablePaths,
fddimibPORTCurrentPath,
fddimibPORTRequestedPaths,
fddimibPORTMyType,
fddimibPORTNeighborType }
DESCRIPTION
"This event is generated when the value of the
fddiPORTCurrentPath (lbOptPORTCurrentPath)
changes. This event shall be surpressed if the
value changes from isolated to local or local
to isolated (see 7.2.7 and 8.3)."
REFERENCE
"ANSI { fddiPORT 83 }"
::= 11
END