VINES-MIB { iso org(3) dod(6) internet(1) private(4) enterprises(1) 130 }
DEFINITIONS ::= BEGIN
IMPORTS
enterprises, OBJECT-TYPE, NetworkAddress, IpAddress, Counter,
Gauge, TimeTicks
FROM RFC1155-SMI;
banyan OBJECT IDENTIFIER ::= { enterprises 130 }
vinesmibs OBJECT IDENTIFIER ::= { banyan 1 }
mib1 OBJECT IDENTIFIER ::= { vinesmibs 1 }
systemsummary OBJECT IDENTIFIER ::= { mib1 1 }
services OBJECT IDENTIFIER ::= { mib1 2 }
peripherals OBJECT IDENTIFIER ::= { mib1 3 }
filesystem OBJECT IDENTIFIER ::= { mib1 4 }
commresources OBJECT IDENTIFIER ::= { mib1 5 }
vip OBJECT IDENTIFIER ::= { mib1 6 }
vrtp OBJECT IDENTIFIER ::= { mib1 7 }
vspp OBJECT IDENTIFIER ::= { mib1 8 }
vinterfaces OBJECT IDENTIFIER ::= { mib1 9 }
ssName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The StreetTalk name of the server, up to 15 characters long."
::= { systemsummary 1 }
ssNetid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VINES network ID of the server equal to the servr's serial
number. This id may be up to 4 bytes in length."
::= { systemsummary 2 }
ssSwRev OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The VINES software revision for this server."
::= { systemsummary 3 }
ssLoadAvg1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The one minute exponential decaying average of server load."
::= { systemsummary 4 }
ssLoadAvg5 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The five minute exponential decaying average of server load."
::= { systemsummary 5 }
ssLoadAvg15 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The 15 minute exponential decaying average of server load."
::= { systemsummary 6 }
ssMsgAvg1 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The one minute exponential decaying average of network
messages sent and received per second."
::= { systemsummary 7 }
ssMsgsIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of network messages that the server has
received over the network since the last reboot."
::= { systemsummary 8 }
ssMsgsOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of network messages that the server has sent
over the network since the last reboot."
::= { systemsummary 9 }
ssDrops OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of received messages that could not be
processed due to a lack of communications buffer space."
::= { systemsummary 10 }
ssSwapAvg OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An exponential decaying average of the number of times a
process was swapped to or from disk per second over a one
minute period."
::= { systemsummary 11 }
svcNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of services in the svcTable."
::= { services 1 }
svcTable OBJECT-TYPE
SYNTAX SEQUENCE OF SvcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of services on the server."
::= { services 2 }
svcEntry OBJECT-TYPE
SYNTAX SvcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Each entry contains a set of statistics for one service."
INDEX { svcIndex }
::= { svcTable 1 }
SvcEntry ::= SEQUENCE {
svcIndex
INTEGER,
svcName
OCTET STRING,
svcStatus
INTEGER,
svcUpTime
TimeTicks,
svcMsgsIn
Counter,
svcMsgsOut
Counter,
svcLocIn
Counter,
svcLocOut
Counter,
svcActSess
INTEGER,
svcTotSess
Counter,
svcCategory
INTEGER
}
svcIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each service used by SNMP to keep track of
service table entries. This value may vary if the table
changes."
::= { svcEntry 1 }
svcName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The StreetTalk name of the service, the names are of the form
'item@group@organization'."
::= { svcEntry 2 }
svcStatus OBJECT-TYPE
SYNTAX INTEGER {
running(1),
initializing(2),
crashing(3),
inconsistent(4),
stopped(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the service.
Running - available to users.
Initializing - starting and will be available shortly.
Crashing - not functioning properly.
Inconsistent - the name cannot be found.
Stopped - not running."
::= { svcEntry 3 }
svcUpTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of time that the service has been running."
::= { svcEntry 4 }
svcMsgsIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of messages that the service has received
over the network since the service was last started."
::= { svcEntry 5 }
svcMsgsOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of messages that the service has sent
over the network since the service was last started."
::= { svcEntry 6 }
svcLocIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of messages received by the service that were sent
by entities that are local to the service's server since the
service was last started."
::= { svcEntry 7 }
svcLocOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of messages sent by the service to entities that
are local to the service's server since the service was last
started."
::= { svcEntry 8 }
svcActSess OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active sessions with the service."
::= { svcEntry 9 }
svcTotSess OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of sessions that the service has handled
since it was last started."
::= { svcEntry 10 }
svcCategory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of service defined as follows:
1 Server service
2 File Service or DOS/UNIX bridge file service
3 Print Service
4 Mail Service
5 StreeTalk Service
8 Semaphore Service
9 3270/SNA Service
10 Asynchronous Terminal Emulation Service
12 Netbios Name Service
14 3270/BSC Service
16 Network Management Service
17 VINES Security Service
18 StreeTalk Directory Assistance Service
1887 SNMP Service
1888 SMTP Service
Third-party services return values from 1000 to 1899."
::= { svcEntry 11 }
svcUserTable OBJECT-TYPE
SYNTAX SEQUENCE OF SvcUserEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of the users for the services."
::= { services 3 }
svcUserEntry OBJECT-TYPE
SYNTAX SvcUserEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the list of service users."
INDEX { svcUserSvcIndex,
svcUserIndex }
::= { svcUserTable 1 }
SvcUserEntry ::= SEQUENCE {
svcUserSvcIndex
INTEGER,
svcUserIndex
INTEGER,
svcUserSvcName
OCTET STRING,
svcUserName
OCTET STRING
}
svcUserSvcIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each service on the server, used by SNMP
to order the list."
::= { svcUserEntry 1 }
svcUserIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each user of a service. This value will
change as new users are added and old users deleted from the
service."
::= { svcUserEntry 2 }
svcUserSvcName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The StreetTalk name of the service."
::= { svcUserEntry 3 }
svcUserName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The StreetTalk name of the user of the service."
::= { svcUserEntry 4 }
dskNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of disks in the disk table."
::= { peripherals 1 }
dskTable OBJECT-TYPE
SYNTAX SEQUENCE OF DskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of statistics for the disks on this server."
::= { peripherals 2 }
dskEntry OBJECT-TYPE
SYNTAX DskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The statistics for one disk."
INDEX { dskIndex }
::= { dskTable 1 }
DskEntry ::= SEQUENCE {
dskIndex
INTEGER,
dskName
OCTET STRING,
dskUtil
INTEGER,
dskDemand
INTEGER,
dskSizeMB
INTEGER,
dskUsedPct
INTEGER,
dskStatus
INTEGER,
dskNOperations
INTEGER,
dskNBlocks
INTEGER
}
dskIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each disk on the server, used by SNMP to
order the table."
::= { dskEntry 1 }
dskName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the disk unit."
::= { dskEntry 2 }
dskUtil OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A five minute exponential decaying average showing the
percentage of time that the disk unit was in use transferring
data."
::= { dskEntry 3 }
dskDemand OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A five minute exponential decaying average showing the
percentage of time that the disk unit needed to be used to
satisfy all requests."
::= { dskEntry 4 }
dskSizeMB OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the disk in megabytes."
::= { dskEntry 5 }
dskUsedPct OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The percentage of disk space that is currently in use."
::= { dskEntry 6 }
dskStatus OBJECT-TYPE
SYNTAX INTEGER {
down(1),
up(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The disks status, 1 is non-operational, 2 is operational."
::= { dskEntry 7 }
dskNOperations OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of reads and writes for the disk since the
server was last booted."
::= { dskEntry 8 }
dskNBlocks OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of 1-kilobyte data blocks transferred to and
from the disk since the server was last booted."
::= { dskEntry 9 }
prnNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of printers in the printer table."
::= { peripherals 3 }
prnTable OBJECT-TYPE
SYNTAX SEQUENCE OF PrnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of the printers on the server."
::= { peripherals 4 }
prnEntry OBJECT-TYPE
SYNTAX PrnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information for a printer on the server."
INDEX { prnIndex }
::= { prnTable 1 }
PrnEntry ::= SEQUENCE {
prnIndex
INTEGER,
prnName
OCTET STRING,
prnType
INTEGER
}
prnIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each printer connected to the server, used
by SNMP to order the table. This may change if a printer is
added or removed from the server."
::= { prnEntry 1 }
prnName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The StreetTalk name of the printer's VINES print service."
::= { prnEntry 2 }
prnType OBJECT-TYPE
SYNTAX INTEGER {
parallel(1),
serial(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The printer type."
::= { prnEntry 3 }
fsTotCache OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of server RAM, in kilobytes, that is used for
caching purposes. This is configurable from the server's
console."
::= { filesystem 1 }
fsCacheBufSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of server RAM, in kilobytes, that makes up a file
system cache buffer. Also configurable from the console."
::= { filesystem 2 }
fsMaxOpenFiles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The largest number of open files on the server at a single
point in time."
::= { filesystem 3 }
fsOpenFiles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of files currently open."
::= { filesystem 4 }
fsMaxOpensOnFiles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The largest number of open operations on files at a single
point in time. There can be more than one open operation on
an open file. For example, two users may open the same file.
This file would count as one open file and two open operations
on the file."
::= { filesystem 5 }
fsOpensOnFiles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of open operations on files."
::= { filesystem 6 }
fsRecLocks OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of record locks."
::= { filesystem 7 }
fsMaxRecLocks OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The largest number of simultaneous record locks."
::= { filesystem 8 }
fsPctCacheHits OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The percentage of cache buffer requests that the system was
able to service using existing cache buffers, without reading
new data from disk."
::= { filesystem 9 }
fsCacheUnavail OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cache buffer requests that the server was
unable to service without reading new data from disk."
::= { filesystem 10 }
commTotBufs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total communications buffer space (the amount of server
RAM used for network communications) in kilobytes. This is
configurable from the server's console."
::= { commresources 1 }
commBufUsage OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The percentage of the communications buffer space currently
in use."
::= { commresources 2 }
commAllocsFailed OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The cumulative total of the number of buffers that could not
be allocated since the server was last booted."
::= { commresources 3 }
commSocksCfg OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of sockets that can be open at one time.
Configurable from the server console."
::= { commresources 4 }
commSocksInUse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The percentage of the maximum configured sockets in use."
::= { commresources 5 }
commMaxOpenSocks OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of sockets in use since the server was
last booted."
::= { commresources 6 }
vipTotIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of VINES IP packets that the server has
received since the server was last booted."
::= { vip 1 }
vipTotOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of VINES IP packets that the server has
sent since the server was last booted."
::= { vip 2 }
vipBad OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of badly formed packets that the server
has received since the server was last booted."
::= { vip 3 }
vipRouted OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of packets that were routed to another node
since the server was last booted."
::= { vip 4 }
vipRoutedHWM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The largest number of packets routed in 1 second since the
server was last booted."
::= { vip 5 }
vipBcast OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of VINES IP broadcast packets sent, both generated
from the server and routed from other nodes."
::= { vip 6 }
vipBcastHWM OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The largest number of packets broadcast in 1 second since the
server was last booted."
::= { vip 7 }
vipReass OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times packets were reassembled since the server
was last booted. One VINES IP packet being broken into three
message fragments is counted as one fragmentation. The three
fragments being reassembled into one VINES IP packet counts as
one reassembly."
::= { vip 8 }
vipFrags OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packet fragmentations performed since the server
was last booted."
::= { vip 9 }
vipToDodIP OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that VINES IP passed to DARAP IP
(TCP/IP) for encapsulation in IP headers since the server was
last booted."
::= { vip 10 }
vipFromDodIP OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that VINES IP received from DARPA IP
(TCP/IP) since the server was last booted."
::= { vip 11 }
vrtpNbrNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of entries in the neighbor table (NbrTable)."
::= { vrtp 1 }
vrtpNbrTable OBJECT-TYPE
SYNTAX SEQUENCE OF NbrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of information about neighbors of this server."
::= { vrtp 2 }
vrtpNbrEntry OBJECT-TYPE
SYNTAX NbrEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The information for each entry in the table."
INDEX { vrtpNbrNetid,
vrtpNbrSubNetid,
vrtpNbrIfType,
vrtpNbrLocSlot,
vrtpNbrLocLine }
::= { vrtpNbrTable 1 }
NbrEntry ::= SEQUENCE {
vrtpNbrNetid
INTEGER,
vrtpNbrSubNetid
INTEGER,
vrtpNbrType
INTEGER,
vrtpNbrIfType
INTEGER,
vrtpNbrRemAddress
OCTET STRING,
vrtpNbrLocAddress
OCTET STRING,
vrtpNbrLocSlot
INTEGER,
vrtpNbrLocLine
INTEGER,
vrtpNbrSvrName
OCTET STRING
}
vrtpNbrNetid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network ID of the neighbor, which is the first part of
the neighbor's VINES internet address. If the neighbor is a
server the network number is the server's serial number."
::= { vrtpNbrEntry 1 }
vrtpNbrSubNetid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The subnetwork ID of the neighbor, which is the second part of
the neighbor's VINES internet address. If the neighbor is a
server the subnetwork number is 1."
::= { vrtpNbrEntry 2 }
vrtpNbrType OBJECT-TYPE
SYNTAX INTEGER {
server(1),
workstation(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the neighbor (workstation = pc)."
::= { vrtpNbrEntry 3 }
vrtpNbrIfType OBJECT-TYPE
SYNTAX INTEGER {
ethernet3Com(1),
ethernetNI5010(2),
ethernetBICC(3),
ethernetUB(4),
omninetCorvus(5),
arcnetSMC(6),
pcnetSytek(7),
proNetProteon(8),
unused9(9),
unused10(10),
hdlc(11),
blkAsync(12),
unused13(13),
unused14(14),
tokenRingIBM(15),
x25(16),
tokenRingUB(17),
ipaDavidSys(18),
tokenRingPronet4(19),
ethernetEplus3Com(20),
lanLinkNT(21),
unused22(22),
ethernetNI5210(23),
unused24(24),
unused25(25),
unused26(26),
starlanWDigital(27),
ethernetWDigital(28),
starlanATT(29),
starlanNI5210(30),
ethernet3Com3C503(31),
ethernet3Com3C523(32),
tokenRing3Com3C603(33),
lanLinkNTMC(34),
unused35(35),
ethernetIntelPC586E(36),
starlanATT10(37),
pronetProteonMC(38),
arcnetSMCMC(39),
tokenRingIBMMC(40),
ethernetNI9210MC(41)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of interface that the server uses to reach the
neighbor."
::= { vrtpNbrEntry 4 }
vrtpNbrRemAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The address of the neighbor's physical interface, such as a
LAN address. If the neighbor is connected via an HDLC or
asynchronous line this object specifies an internal id."
::= { vrtpNbrEntry 5 }
vrtpNbrLocAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The address of the server's physical interface, sucha as a
LAN address."
::= { vrtpNbrEntry 6 }
vrtpNbrLocSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of the interface card that the server uses to
reach the neighbor."
::= { vrtpNbrEntry 7 }
vrtpNbrLocLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of the line on the serial card that the server uses
to reach the neighbor. It does not apply to neighbors that are
reached over LANs."
::= { vrtpNbrEntry 8 }
vrtpNbrSvrName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the neighbor. If the neighbor is a workstation
then this object has no meaning."
::= { vrtpNbrEntry 9 }
vrtpRtNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of entires in the route table (RtTable)."
::= { vrtp 3 }
vrtpRtTable OBJECT-TYPE
SYNTAX SEQUENCE OF RtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of networks and the routing information to find them."
::= { vrtp 4 }
vrtpRtEntry OBJECT-TYPE
SYNTAX RtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry for one network."
INDEX { vrtpRtNetid }
::= { vrtpRtTable 1 }
RtEntry ::= SEQUENCE {
vrtpRtNetid
INTEGER,
vrtpRtMetric
INTEGER,
vrtpRtIdle
INTEGER,
vrtpRtGateNetid
INTEGER,
vrtpRtSvrName
OCTET STRING,
vrtpRtGateSvrName
OCTET STRING
}
vrtpRtNetid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network ID of the route's destination server."
::= { vrtpRtEntry 1 }
vrtpRtMetric OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The routing metric used by the called server to reach the
destination. The metric reflects the cost of the path to
the destination, it is in 200-millisecond units."
::= { vrtpRtEntry 2 }
vrtpRtIdle OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time to live timer for this route's entry. This value
indicicates the amount of time before the entry is removed
from the called server's routing table. The value is returned
in 90 second units."
::= { vrtpRtEntry 3 }
vrtpRtGateNetid OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network ID of the server that acts as the router for
reaching the destination server."
::= { vrtpRtEntry 4 }
vrtpRtSvrName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"The name of the destination server."
::= { vrtpRtEntry 5 }
vrtpRtGateSvrName OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS optional
DESCRIPTION
"The name of the server that acts as the router for reaching
the destination server."
::= { vrtpRtEntry 6 }
vsppConnsInUse OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of SPP connections currently in use by processes
on the server."
::= { vspp 1 }
vsppConnsCfg OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of SPP connections that can be in use
on the server at one time."
::= { vspp 2 }
vsppMaxConns OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of SPP connections in use at a single
point in time since the server was last booted."
::= { vspp 3 }
vifNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of VINES interfaces configured on the server."
::= { vinterfaces 1 }
vifTable OBJECT-TYPE
SYNTAX SEQUENCE OF IfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"List of interfaces with some statistics about each interface."
::= { vinterfaces 2 }
vifEntry OBJECT-TYPE
SYNTAX IfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about one interface."
INDEX { vifSlot,
vifLine,
vifSession }
::= { vifTable 1 }
IfEntry ::= SEQUENCE {
vifSlot
INTEGER,
vifLine
INTEGER,
vifSession
INTEGER,
vifType
INTEGER,
vifDescr
OCTET STRING,
vifAddress
OCTET STRING,
vifInPkts
Counter,
vifInErrs
Counter,
vifOutPkts
Counter,
vifOutErrs
Counter
}
vifSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of the interface's communications card."
::= { vifEntry 1 }
vifLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The line number of the interface, applies to serial interfaces
only."
::= { vifEntry 2 }
vifSession OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The local session number of an X.25 virtual circuit, applies
to X.25 interfaces only."
::= { vifEntry 3 }
vifType OBJECT-TYPE
SYNTAX INTEGER {
ethernet3Com(1),
ethernetNI5010(2),
ethernetBICC(3),
ethernetUB(4),
omninetCorvus(5),
arcnetSMC(6),
pcnetSytek(7),
proNetProteon(8),
unused9(9),
unused10(10),
hdlc(11),
blkAsync(12),
unused13(13),
unused14(14),
tokenRingIBM(15),
x25(16),
tokenRingUB(17),
ipaDavidSys(18),
tokenRingPronet4(19),
ethernetEplus3Com(20),
lanLinkNT(21),
unused22(22),
ethernetNI5210(23),
unused24(24),
unused25(25),
unused26(26),
starlanWDigital(27),
ethernetWDigital(28),
starlanATT(29),
starlanNI5210(30),
ethernet3Com3C503(31),
ethernet3Com3C523(32),
tokenRing3Com3C603(33),
lanLinkNTMC(34),
unused35(35),
ethernetIntelPC586E(36),
starlanATT10(37),
pronetProteonMC(38),
arcnetSMCMC(39),
tokenRingIBMMC(40),
ethernetNI9210MC(41)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interface type, types are the same as defined for
vrtpNbrIfType in the vrtp neighbor table."
::= { vifEntry 4 }
vifDescr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the interface."
::= { vifEntry 5 }
vifAddress OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The physical address of the interface, applies to LAN
interfaces only."
::= { vifEntry 6 }
vifInPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of VINES IP packets that the server
received since the last reboot."
::= { vifEntry 7 }
vifInErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of received VINES IP packets that contained
errors since the last reboot."
::= { vifEntry 8 }
vifOutPkts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of VINES IP packets that the server
sent since the last reboot."
::= { vifEntry 9 }
vifOutErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of transmitted VINES IP packets that
contained errors since the last reboot."
::= { vifEntry 10 }
vifLnkNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of serial links connected to the server."
::= { vinterfaces 3 }
vifLnkTable OBJECT-TYPE
SYNTAX SEQUENCE OF LnkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Data link level statistics for the serial lines on
this server."
::= { vinterfaces 4 }
vifLnkEntry OBJECT-TYPE
SYNTAX LnkEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Stats for one serial line."
INDEX { vifLnkSlot,
vifLnkLine }
::= { vifLnkTable 1 }
LnkEntry ::= SEQUENCE {
vifLnkSlot
INTEGER,
vifLnkLine
INTEGER,
vifLnkType
INTEGER,
vifLnkTotIn
Counter,
vifLnkTotOut
Counter,
vifLnkRetrans
Counter,
vifLnkCRCErrs
Counter,
vifLnkDrops
Counter,
vifLnkUnders
Counter,
vifLnkOvers
Counter,
vifLnkFrmErrs
Counter
}
vifLnkSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of the serial communications card to which
the serial line is connected."
::= { vifLnkEntry 1 }
vifLnkLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The line number of the line on the serial communications
card."
::= { vifLnkEntry 2 }
vifLnkType OBJECT-TYPE
SYNTAX INTEGER {
ate(1),
unused2(2),
unused3(3),
unused4(4),
unused5(5),
unused6(6),
blkasynch(7),
hdlc(8),
x25(9),
sdlcv1(10),
bsc3270(11),
sdlcv2(12)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of data link level protocol used on this line.
1 Asynchronous Terminal Emulation.
7 Block asynchronous.
8 High-level Data Link Control (HDLC).
9 X.25
10 Synchronous DataLink Control (SDLC) 1.
11 3270/BSC bisynchronous communication.
12 Same as SDLC1 except line is connected to an ICA card."
::= { vifLnkEntry 3 }
vifLnkTotIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of frames received."
::= { vifLnkEntry 4 }
vifLnkTotOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of frames transmitted."
::= { vifLnkEntry 5 }
vifLnkRetrans OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of frames retransmitted."
::= { vifLnkEntry 6 }
vifLnkCRCErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of errors due to CRC or frames that the card
dropped."
::= { vifLnkEntry 7 }
vifLnkDrops OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames that the server could not receive due to
a lack of communications buffers."
::= { vifLnkEntry 8 }
vifLnkUnders OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of transmitter underrun errors on receive."
::= { vifLnkEntry 9 }
vifLnkOvers OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of receiver overrun errors on receive."
::= { vifLnkEntry 10 }
vifLnkFrmErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of framing errors."
::= { vifLnkEntry 11 }
vifX25VCNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of X.25 virtual circuits that are available to
the server."
::= { vinterfaces 5 }
vifX25VCTable OBJECT-TYPE
SYNTAX SEQUENCE OF X25VCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of X.25 packet level statistics for the virtual
circuit."
::= { vinterfaces 6 }
vifX25VCEntry OBJECT-TYPE
SYNTAX X25VCEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Statistics for one virtual circuit."
INDEX { vifX25VCSlot,
vifX25VCLine,
vifX25VCSession }
::= { vifX25VCTable 1 }
X25VCEntry ::= SEQUENCE {
vifX25VCSlot
INTEGER,
vifX25VCLine
INTEGER,
vifX25VCSession
INTEGER,
vifX25VCTotIn
Counter,
vifX25VCTotOut
Counter,
vifX25VCInErrs
Counter,
vifX25VCOutErrs
Counter,
vifX25VCPktsOut
Counter,
vifX25VCPktsAwaitAck
INTEGER,
vifX25VCBytesOut
Counter,
vifX25VCBytesAwaitAck
INTEGER,
vifX25VCPktsIn
Counter,
vifX25VCBytesIn
Counter,
vifX25VCResetsIn
Counter,
vifX25VCResetsOut
Counter
}
vifX25VCSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of the serial communications card to which
the virtual circuit's line is connected."
::= { vifX25VCEntry 1 }
vifX25VCLine OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of the X.25 line configured on the serial
communications card."
::= { vifX25VCEntry 2 }
vifX25VCSession OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The local session number of the virtual circuit."
::= { vifX25VCEntry 3 }
vifX25VCTotIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of VINES IP packets received on this VC."
::= { vifX25VCEntry 4 }
vifX25VCTotOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of VINES IP packets sent on this VC."
::= { vifX25VCEntry 5 }
vifX25VCInErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of received X.25 packets that contained
errors."
::= { vifX25VCEntry 6 }
vifX25VCOutErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of transmitted X.25 packets that contained
errors."
::= { vifX25VCEntry 7 }
vifX25VCPktsOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of X.25 packets transmitted."
::= { vifX25VCEntry 8 }
vifX25VCPktsAwaitAck OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of X.25 packets transmitted that are
awaiting acknowledgement."
::= { vifX25VCEntry 9 }
vifX25VCBytesOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of bytes transmitted."
::= { vifX25VCEntry 10 }
vifX25VCBytesAwaitAck OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of bytes transmitted that are awaiting
acknowledgement."
::= { vifX25VCEntry 11 }
vifX25VCPktsIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of X.25 packets that have been received."
::= { vifX25VCEntry 12 }
vifX25VCBytesIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of bytes received."
::= { vifX25VCEntry 13 }
vifX25VCResetsIn OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of X.25 reset packets received."
::= { vifX25VCEntry 14 }
vifX25VCResetsOut OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of X.25 reset packets transmitted."
::= { vifX25VCEntry 15 }
vifStatsList OBJECT-TYPE
SYNTAX SEQUENCE OF VifStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of statistics for each LAN card in the server. The
type and quantity of statistics depend on the type of the
card."
::= { vinterfaces 7 }
vifStatEntry OBJECT-TYPE
SYNTAX VifStatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The statistics for one card."
INDEX { vifStatSlot,
vifStatIndex }
::= { vifStatsList 1 }
VifStatEntry ::= SEQUENCE {
vifStatSlot
INTEGER,
vifStatIndex
INTEGER,
vifStatDescr
OCTET STRING,
vifStatValue
INTEGER
}
vifStatSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The slot number of the LAN interface card."
::= { vifStatEntry 1 }
vifStatIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique value for each statistic, used by SNMP to order
the table."
::= { vifStatEntry 2 }
vifStatDescr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A brief description of the statistic."
::= { vifStatEntry 3 }
vifStatValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of the statistic."
::= { vifStatEntry 4 }
END