CPQHOST-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises FROM RFC1155-SMI
Counter FROM RFC1155-SMI
IpAddress FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
sysName FROM RFC1213-MIB;
compaq OBJECT IDENTIFIER ::= { enterprises 232 }
cpqHostOs OBJECT IDENTIFIER ::= { compaq 11 }
cpqHoMibRev OBJECT IDENTIFIER ::= { cpqHostOs 1 }
cpqHoComponent OBJECT IDENTIFIER ::= { cpqHostOs 2 }
cpqHoInterface OBJECT IDENTIFIER ::= { cpqHoComponent 1 }
cpqHoInfo OBJECT IDENTIFIER ::= { cpqHoComponent 2 }
cpqHoUtil OBJECT IDENTIFIER ::= { cpqHoComponent 3 }
cpqHoFileSys OBJECT IDENTIFIER ::= { cpqHoComponent 4 }
cpqHoIfPhysMap OBJECT IDENTIFIER ::= { cpqHoComponent 5 }
cpqHoSWRunning OBJECT IDENTIFIER ::= { cpqHoComponent 6 }
cpqHoSwVer OBJECT IDENTIFIER ::= { cpqHoComponent 7 }
cpqHoGeneric OBJECT IDENTIFIER ::= { cpqHoComponent 8 }
cpqHoSwPerf OBJECT IDENTIFIER ::= { cpqHoComponent 9 }
cpqHoSystemStatus OBJECT IDENTIFIER ::= { cpqHoComponent 10 }
cpqHoTrapInfo OBJECT IDENTIFIER ::= { cpqHoComponent 11 }
cpqHoClients OBJECT IDENTIFIER ::= { cpqHoComponent 12 }
cpqHoOsCommon OBJECT IDENTIFIER ::= { cpqHoInterface 4 }
cpqHoMibRevMajor OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Major Revision level of the MIB.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information.
Correct interpretation of data may require a MIB document with
the same major revision level."
::= { cpqHoMibRev 1 }
cpqHoMibRevMinor OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Minor Revision level of the MIB.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred."
::= { cpqHoMibRev 2 }
cpqHoMibCondition OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2), degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The overall condition.
This object represents the overall status of the server's host
system represented by this MIB."
::= { cpqHoMibRev 3 }
cpqHoOsCommonPollFreq OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero (0)
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero (0) will
always fail. An agent may choose to fail any request to change
the poll frequency to a value that would severely impact system
performance."
::= { cpqHoOsCommon 1 }
cpqHoOsCommonModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoOsCommonModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of software modules that provide an interface to the
device this MIB describes."
::= { cpqHoOsCommon 2 }
cpqHoOsCommonModuleEntry OBJECT-TYPE
SYNTAX CpqHoOsCommonModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a software module that provides an interface
to the device this MIB describes."
INDEX { cpqHoOsCommonModuleIndex }
::= { cpqHoOsCommonModuleTable 1 }
CpqHoOsCommonModuleEntry ::= SEQUENCE {
cpqHoOsCommonModuleIndex INTEGER,
cpqHoOsCommonModuleName DisplayString,
cpqHoOsCommonModuleVersion DisplayString,
cpqHoOsCommonModuleDate OCTET STRING,
cpqHoOsCommonModulePurpose DisplayString
}
cpqHoOsCommonModuleIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index for this module description."
::= { cpqHoOsCommonModuleEntry 1 }
cpqHoOsCommonModuleName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module name."
::= { cpqHoOsCommonModuleEntry 2 }
cpqHoOsCommonModuleVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be null (size 0) string if the agent
cannot provide the module version."
::= { cpqHoOsCommonModuleEntry 3 }
cpqHoOsCommonModuleDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octect first."
::= { cpqHoOsCommonModuleEntry 4 }
cpqHoOsCommonModulePurpose OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The purpose of the module described in this entry."
::= { cpqHoOsCommonModuleEntry 5 }
cpqHoName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the host operating system (OS)."
::= { cpqHoInfo 1 }
cpqHoVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the host OS."
::= { cpqHoInfo 2 }
cpqHoDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A further description of the host OS."
::= { cpqHoInfo 3 }
cpqHoOsType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
netware(2), windowsnt(3), sco-unix(4), unixware(5), os-2(6), ms-dos(7), dos-windows(8), windows95(9) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Host Operating system enumeration."
::= { cpqHoInfo 4 }
cpqHoTelnet OBJECT-TYPE
SYNTAX INTEGER {
other(1),
available(2),
notavailable(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Telnet on socket 23 is available."
::= { cpqHoInfo 5 }
cpqHoCpuUtilTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoCpuUtilEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of CPU utilization entries."
::= { cpqHoUtil 1 }
cpqHoCpuUtilEntry OBJECT-TYPE
SYNTAX CpqHoCpuUtilEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a CPU's utilization."
INDEX { cpqHoCpuUtilUnitIndex }
::= { cpqHoCpuUtilTable 1 }
CpqHoCpuUtilEntry ::= SEQUENCE {
cpqHoCpuUtilUnitIndex INTEGER,
cpqHoCpuUtilMin INTEGER,
cpqHoCpuUtilFiveMin INTEGER,
cpqHoCpuUtilThirtyMin INTEGER,
cpqHoCpuUtilHour INTEGER
}
cpqHoCpuUtilUnitIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This number uniquely specifies a processor unit.
A processing unit may be a set of processing chips that are
on the same board or for other reasons work together as a unit.
The main processor unit (if such a concept is valid for this
machine) will always have the lowest (first) index."
::= { cpqHoCpuUtilEntry 1 }
cpqHoCpuUtilMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPU utilization as a percentage of the theoretical
maximum during the last minute. A value of -1 indicates
that no CPU utilization information is available for this
processor."
::= { cpqHoCpuUtilEntry 2 }
cpqHoCpuUtilFiveMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPU utilization as a percentage of the theoretical
maximum during the last five minutes. A value of -1 indicates
that no CPU utilization information is available for this
processor."
::= { cpqHoCpuUtilEntry 3 }
cpqHoCpuUtilThirtyMin OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPU utilization as a percentage of the theoretical
maximum during the last thirty minutes. A value of -1 indicates
that no CPU utilization information is available for this
processor."
::= { cpqHoCpuUtilEntry 4 }
cpqHoCpuUtilHour OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The CPU utilization as a percentage of the theoretical
maximum during the last hour. A value of -1 indicates
that no CPU utilization information is available for this
processor."
::= { cpqHoCpuUtilEntry 5 }
cpqHoFileSysTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoFileSysEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of file system descriptions."
::= { cpqHoFileSys 1 }
cpqHoFileSysEntry OBJECT-TYPE
SYNTAX CpqHoFileSysEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A file system description."
INDEX { cpqHoFileSysIndex }
::= { cpqHoFileSysTable 1 }
CpqHoFileSysEntry ::= SEQUENCE {
cpqHoFileSysIndex INTEGER,
cpqHoFileSysDesc DisplayString,
cpqHoFileSysSpaceTotal INTEGER,
cpqHoFileSysSpaceUsed INTEGER,
cpqHoFileSysPercentSpaceUsed INTEGER,
cpqHoFileSysAllocUnitsTotal INTEGER,
cpqHoFileSysAllocUnitsUsed INTEGER
}
cpqHoFileSysIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry."
::= { cpqHoFileSysEntry 1 }
cpqHoFileSysDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the file system."
::= { cpqHoFileSysEntry 2 }
cpqHoFileSysSpaceTotal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The file system size in megabytes.
This item will be set to -1 if the agent is unable to determine
this information."
::= { cpqHoFileSysEntry 3 }
cpqHoFileSysSpaceUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The megabytes of file system space currently in use.
This item will be set to -1 if the agent is unable to determine
this information."
::= { cpqHoFileSysEntry 4 }
cpqHoFileSysPercentSpaceUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The percent of file system space currently in use.
This item will be set to -1 if this information is not
available."
::= { cpqHoFileSysEntry 5 }
cpqHoFileSysAllocUnitsTotal OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of files (directory entries) that can be
stored on the file system if a limit exists other than
total space used. This item will be set to -1 if no such
limit exists."
::= { cpqHoFileSysEntry 6 }
cpqHoFileSysAllocUnitsUsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of files (directory entries) on this file system.
This item will be set to -1 if the agent does not determine this
information."
::= { cpqHoFileSysEntry 7 }
cpqHoIfPhysMapTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoIfPhysMapEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A table of interface to physical hardware mappings."
::= { cpqHoIfPhysMap 1 }
cpqHoIfPhysMapEntry OBJECT-TYPE
SYNTAX CpqHoIfPhysMapEntry
ACCESS not-accessible
STATUS deprecated
DESCRIPTION
"A mapping of an interface table entry to physical hardware."
INDEX { cpqHoIfPhysMapIndex }
::= { cpqHoIfPhysMapTable 1 }
CpqHoIfPhysMapEntry ::= SEQUENCE {
cpqHoIfPhysMapIndex INTEGER,
cpqHoIfPhysMapSlot INTEGER,
cpqHoIfPhysMapIoBaseAddr INTEGER,
cpqHoIfPhysMapIrq INTEGER,
cpqHoIfPhysMapDma INTEGER,
cpqHoIfPhysMapMemBaseAddr INTEGER,
cpqHoIfPhysMapPort INTEGER,
cpqHoIfPhysMapDuplexState INTEGER,
cpqHoIfPhysMapCondition INTEGER
}
cpqHoIfPhysMapIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"An index that uniquely specifies this entry. This value is
equal to the index of the entry in the MIB-II interface table
to which this entry corresponds."
::= { cpqHoIfPhysMapEntry 1 }
cpqHoIfPhysMapSlot OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of the slot containing the physical hardware that
implements this interface. The number zero (0) indicates an
embedded interface (on the system board) or an interface whose
slot is unknown. Values may be unknown if the physical
hardware has not been configured using the EISA Configuration
Utility."
::= { cpqHoIfPhysMapEntry 2 }
cpqHoIfPhysMapIoBaseAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The base I/O address of the physical hardware that implements
this interface."
::= { cpqHoIfPhysMapEntry 3 }
cpqHoIfPhysMapIrq OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of the IRQ (interrupt) used for this physical
hardware interface. The number zero (0) indicates that this
device does not use an IRQ or this information is unavailable."
::= { cpqHoIfPhysMapEntry 4 }
cpqHoIfPhysMapDma OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The number of the DMA channel used for this physical hardware
interface. The number -1 indicates that this device does not
use a DMA channel or this information is unavailable."
::= { cpqHoIfPhysMapEntry 5 }
cpqHoIfPhysMapMemBaseAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The base memory address used by this physical hardware
interface. The number zero (0) indicates that this device does
not use system memory or this information is unavailable."
::= { cpqHoIfPhysMapEntry 6 }
cpqHoIfPhysMapPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The port number of the interface for multi-port NICs.
A port number of -1 indicates that the port could not
be determined."
::= { cpqHoIfPhysMapEntry 7 }
cpqHoIfPhysMapDuplexState OBJECT-TYPE
SYNTAX INTEGER {
other(1), half(2),
full(3)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"This variable describes the configured duplex state of the NIC."
::= { cpqHoIfPhysMapEntry 8 }
cpqHoIfPhysMapCondition OBJECT-TYPE
SYNTAX INTEGER
{
other(1), ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The condition of this interface."
::= { cpqHoIfPhysMapEntry 9 }
cpqHoIfPhysMapOverallCondition OBJECT-TYPE
SYNTAX INTEGER
{
other(1), ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS deprecated
DESCRIPTION
"The overall condition of all interfaces."
::= { cpqHoIfPhysMap 2 }
cpqHoSWRunningTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoSWRunningEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of descriptions of software running on the system."
::= { cpqHoSWRunning 1 }
cpqHoSWRunningEntry OBJECT-TYPE
SYNTAX CpqHoSWRunningEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a software program running on the system."
INDEX { cpqHoSWRunningIndex }
::= { cpqHoSWRunningTable 1 }
CpqHoSWRunningEntry ::= SEQUENCE {
cpqHoSWRunningIndex INTEGER,
cpqHoSWRunningName DisplayString,
cpqHoSWRunningDesc DisplayString,
cpqHoSWRunningVersion DisplayString,
cpqHoSWRunningDate OCTET STRING,
cpqHoSWRunningMonitor INTEGER,
cpqHoSWRunningState INTEGER
}
cpqHoSWRunningIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry."
::= { cpqHoSWRunningEntry 1 }
cpqHoSWRunningName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the software."
::= { cpqHoSWRunningEntry 2 }
cpqHoSWRunningDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the software."
::= { cpqHoSWRunningEntry 3 }
cpqHoSWRunningVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The version of the software.
This field will be a null (size 0) string if the agent cannot
provide the software version."
::= { cpqHoSWRunningEntry 4 }
cpqHoSWRunningDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The software date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the software date. The hour, minute, and second field will be
set to zero (0) if they are not relevant."
::= { cpqHoSWRunningEntry 5 }
cpqHoSWRunningMonitor OBJECT-TYPE
SYNTAX INTEGER
{
other(1), start(2),
stop(3),
startAndStop(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The user specified monitor option for a process."
::= { cpqHoSWRunningEntry 6 }
cpqHoSWRunningState OBJECT-TYPE
SYNTAX INTEGER
{
other(1), started(2),
stopped(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of monitored process."
::= { cpqHoSWRunningEntry 7 }
cpqHoSwRunningTrapDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The error message for a process monitor event."
::= { cpqHoSWRunning 2 }
cpqHoSwVerNextIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index of the next available entry in the cpqHoSwVer
table. If the maximum number of entries to the cpqHoSwVer
table has been reached, this index will contain -1."
::= { cpqHoSwVer 1 }
cpqHoSwVerTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoSwVerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of software item entries."
::= { cpqHoSwVer 2 }
cpqHoSwVerEntry OBJECT-TYPE
SYNTAX CpqHoSwVerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of software items that are on the machine."
INDEX { cpqHoSwVerIndex }
::= { cpqHoSwVerTable 1 }
CpqHoSwVerEntry ::= SEQUENCE {
cpqHoSwVerIndex INTEGER,
cpqHoSwVerStatus INTEGER,
cpqHoSwVerType INTEGER,
cpqHoSwVerName DisplayString,
cpqHoSwVerDescription DisplayString,
cpqHoSwVerDate OCTET STRING,
cpqHoSwVerLocation DisplayString,
cpqHoSwVerVersion DisplayString
}
cpqHoSwVerIndex OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely identifies an entry in the
cpqHoSwVer table."
::= { cpqHoSwVerEntry 1 }
cpqHoSwVerStatus OBJECT-TYPE
SYNTAX INTEGER {
other(1), loaded(2), notloaded(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status for the software item."
::= { cpqHoSwVerEntry 2 }
cpqHoSwVerType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
driver(2), agent(3),
sysutil(4),
application(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of software item."
::= { cpqHoSwVerEntry 3 }
cpqHoSwVerName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of this software item."
::= { cpqHoSwVerEntry 4 }
cpqHoSwVerDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..127))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The description of this software item."
::= { cpqHoSwVerEntry 5 }
cpqHoSwVerDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date of the software item, if any.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65535
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
The year field is set with the most significant octect first.
An entry of zero (0) means that there is no date associated with
this software item. Zero is the default."
::= { cpqHoSwVerEntry 6 }
cpqHoSwVerLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The location of this software item on the server."
::= { cpqHoSwVerEntry 7 }
cpqHoSwVerVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..50))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An string that specifies the version of this item."
::= { cpqHoSwVerEntry 8 }
cpqHoGenericData OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..254))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Data for the generic trap."
::= { cpqHoGeneric 1 }
cpqHoSwPerfAppErrorDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..254))
ACCESS read-only
STATUS mandatory
DESCRIPTION
" This string holds error information about the last application
error that occurred in the system. "
::= { cpqHoSwPerf 1 }
cpqHoMibStatusArray OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (4..256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The MIB Status Array is an array of MIB status structures. Each
structure is made up of 4 octets. The first octet is the MIB
presence. The second octet is MIB condition. The third octet is
MIB major revision. The fourth octet is MIB minor revision.
Status This is a collection of flags. Each bit has the
following meaning when it is on (1):
Bit 2-7: RESERVED: Always 0
Bit 1: MIB is from offline data (only applies
to global system status)
Bit 0: MIB is available
NOTE: bit 7 is the most significant bit, bit 0
is the least significant.
Condition 0 - Not available
1 - Other
2 - OK
3 - Degraded
4 - Failed
Major Revison 0..255, where 0 is not available
Minor Revision 0..255, where 0 is not available
Array element 0 is the status for all MIBs in the Compaq
Enterprise. Array element n, where n > 0, is the status for the
nth MIB in the Compaq Enterprise (.1.3.6.1.4.1.232.n).
Octet Element Field
======== ======= =========
0 0 Status of any Compaq MIBs
1 Condition of all Compaq MIBs
2 System Flags (see below)
3 Reserved - always 0
4 1 Status of Compaq MIB 1
5 Condition of Compaq MIB 1
6 Major Revision of Compaq MIB 1
7 Minor Revision of Compaq MIB 1
8 2 Status of Compaq MIB 2
9 Condition of Compaq MIB 2
10 Major Revision of Compaq MIB 2
11 Minor Revision of Compaq MIB 2
. .
.
.
n*4 n Status of Compaq MIB n
(n*4)+1 Condition of Compaq MIB n
(n*4)+2 Major Revision of Compaq MIB n
(n*4)+3 Minor Revision of Compaq MIB n
System Flags (octet 2)
Bit Meaning
===== =========
0 This system should not appear in the Responsible
Server List if discovered in the NetWare Bindery
1 This system contains enabled remote console
functionality.
2 This system is configured to be a codeserver.
3 Web Management is enabled.
4-7 Reserved"
::= { cpqHoSystemStatus 1 }
cpqHoConfigChangedDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date/time when the agents were last loaded.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the date/time. The year field is set with the most significant
octect first."
::= { cpqHoSystemStatus 2 }
cpqHoGUID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The globally unique identifier of this server.
If the OS cannot determine a unique ID, it will default the
variable to contain all 0's. The management station can then
perform a SET to this variable to provide the unique ID."
::= { cpqHoSystemStatus 3 }
cpqHoCodeServer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This item indicates how many code server shares are currently
configured on the system. If the value of this attribute is
0, this server has not been configured with code server shares."
::= { cpqHoSystemStatus 4 }
cpqHoWebMgmtPort OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This item indicates the port used by the Insight Web Agent.
If the port cannot be determined or the Web Management agent
is not enabled, this value will be -1."
::= { cpqHoSystemStatus 5 }
cpqHoTrapFlags OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Trap Flags.
This is a collection of flags used during trap delivery.
Each bit has the following meaning:
Bit 2-31: RESERVED: Always 0.
Bit 1: Client IP address type
0 = static entry
1 = DHCP entry
Bit 0: Agent Type
0 = Server
1 = Client
NOTE: bit 31 is the most significant bit, bit 0 is the least
significant."
::= { cpqHoTrapInfo 1 }
cpqHoClientLastModified OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The date/time of the last modification to the client table.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to all 0's if there are no entries to the
client table.
The year field will be set to 0xFFFF if the agent does not support
the client table.
The year field is set with the most significant octect first."
::= { cpqHoClients 1 }
cpqHoClientDelete OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this variable to the name of a client in the client table
will cause that row in the table to be deleted. Any other set
will fail.
Note that the indices of the table will (most likely) be renumbered
following a deletion."
::= { cpqHoClients 2 }
cpqHoClientTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqHoClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of client descriptions."
::= { cpqHoClients 3 }
cpqHoClientEntry OBJECT-TYPE
SYNTAX CpqHoClientEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A client description."
INDEX { cpqHoClientIndex }
::= { cpqHoClientTable 1 }
CpqHoClientEntry ::= SEQUENCE {
cpqHoClientIndex INTEGER,
cpqHoClientName DisplayString,
cpqHoClientIpxAddress OCTET STRING,
cpqHoClientIpAddress IpAddress,
cpqHoClientCommunity DisplayString,
cpqHoClientID OCTET STRING
}
cpqHoClientIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry."
::= { cpqHoClientEntry 1 }
cpqHoClientName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Win95 machine name of this client."
::= { cpqHoClientEntry 2 }
cpqHoClientIpxAddress OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (20))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IPX address for this client, all octets should be set to
0xff if this machine does not support IPX.
The format is NetAddr:NodeNumber and sent in MSB order:
1111111111
01234567:890123456789"
::= { cpqHoClientEntry 3 }
cpqHoClientIpAddress OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The IP address for this client, all octets should be set to
0xff if this machine does not support IP. The order will be
in network byte order (ie MSB first.)"
::= { cpqHoClientEntry 4 }
cpqHoClientCommunity OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..48))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A community name that can be used to query the client with SNMP.
This community name should have, but is not required to have,
the greatest possible access to client information."
::= { cpqHoClientEntry 5 }
cpqHoClientID OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (16))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique identifier of this client."
::= { cpqHoClientEntry 6 }
cpqHoGenericTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { cpqHoGenericData }
DESCRIPTION
"Generic trap."
::= 11001
cpqHoAppErrorTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { cpqHoSwPerfAppErrorDesc }
DESCRIPTION
"An application has generated an exception. Specific
error information is contained in the variable
cpqHoSwPerfAppErrorDesc."
::= 11002
cpqHo2GenericTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoGenericData }
DESCRIPTION
"Generic trap."
::= 11003
cpqHo2AppErrorTrap TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoSwPerfAppErrorDesc }
DESCRIPTION
"An application has generated an exception. Specific
error information is contained in the variable
cpqHoSwPerfAppErrorDesc."
::= 11004
cpqHo2NicStatusOk TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot }
DESCRIPTION
"This trap will be sent any time the status of a NIC changes to
the OK condition."
::= 11005
cpqHo2NicStatusFailed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot }
DESCRIPTION
"This trap will be sent any time the status of a NIC changes to
the Failed condition."
::= 11006
cpqHo2NicSwitchoverOccurred TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot, cpqHoIfPhysMapSlot }
DESCRIPTION
"This trap will be sent any time the configured redundant NIC
becomes the active NIC."
::= 11007
cpqHo2NicStatusOk2 TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot,
cpqHoIfPhysMapPort }
DESCRIPTION
"This trap will be sent any time the status of a NIC changes to
the OK condition."
::= 11008
cpqHo2NicStatusFailed2 TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqHoIfPhysMapSlot,
cpqHoIfPhysMapPort }