CPQSTDEQ-MIB DEFINITIONS ::= BEGIN
IMPORTS
compaq FROM CPQHOST-MIB
enterprises FROM RFC1155-SMI
Counter FROM RFC1155-SMI
Gauge FROM RFC1155-SMI
DisplayString FROM RFC1213-MIB
OBJECT-TYPE FROM RFC-1212
TRAP-TYPE FROM RFC-1215
sysName FROM RFC1213-MIB
cpqHoTrapFlags FROM CPQHOST-MIB;
cpqStdEquipment OBJECT IDENTIFIER ::= { compaq 1 }
cpqSeMibRev OBJECT IDENTIFIER ::= { cpqStdEquipment 1 }
cpqSeComponent OBJECT IDENTIFIER ::= { cpqStdEquipment 2 }
cpqSeInterface OBJECT IDENTIFIER ::= { cpqSeComponent 1 }
cpqSeProcessor OBJECT IDENTIFIER ::= { cpqSeComponent 2 }
cpqSeMemory OBJECT IDENTIFIER ::= { cpqSeComponent 3 }
cpqSeIsaCmos OBJECT IDENTIFIER ::= { cpqSeComponent 4 }
cpqSeEisaNvram OBJECT IDENTIFIER ::= { cpqSeComponent 5 }
cpqSeRom OBJECT IDENTIFIER ::= { cpqSeComponent 6 }
cpqSeKeyboard OBJECT IDENTIFIER ::= { cpqSeComponent 7 }
cpqSeVideo OBJECT IDENTIFIER ::= { cpqSeComponent 8 }
cpqSeSerialPort OBJECT IDENTIFIER ::= { cpqSeComponent 9 }
cpqSeParallelPort OBJECT IDENTIFIER ::= { cpqSeComponent 10 }
cpqSeFloppyDisk OBJECT IDENTIFIER ::= { cpqSeComponent 11 }
cpqSeFixedDisk OBJECT IDENTIFIER ::= { cpqSeComponent 12 }
cpqSePci OBJECT IDENTIFIER ::= { cpqSeComponent 13 }
cpqSePCCard OBJECT IDENTIFIER ::= { cpqSeComponent 14 }
cpqSeOsCommon OBJECT IDENTIFIER ::= { cpqSeInterface 4 }
cpqSeMibRevMajor OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Major Revision level of the MIB.
A change in the major revision level represents a major change
in the architecture of the MIB. A change in the major revision
level may indicate a significant change in the information
supported and/or the meaning of the supported information,
correct interpretation of data may require a MIB document with
the same major revision level."
::= { cpqSeMibRev 1 }
cpqSeMibRevMinor OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Minor Revision level of the MIB.
A change in the minor revision level may represent some minor
additional support, no changes to any pre-existing information
has occurred."
::= { cpqSeMibRev 2 }
cpqSeMibCondition OBJECT-TYPE
SYNTAX INTEGER {
other(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The overall condition.
This object represents the overall status of the server
represented by this MIB."
::= { cpqSeMibRev 3 }
cpqSeOsCommonPollFreq OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Insight Agent's polling frequency.
The frequency, in seconds, at which the Insight Agent requests
information from the device driver. A frequency of zero (0)
indicates that the Insight Agent retrieves the information upon
request of a management station, it does not poll the device
driver at a specific interval.
If the poll frequency is zero (0) all attempts to write to this
object will fail. If the poll frequency is non-zero,
setting this value will change the polling frequency of the
Insight Agent. Setting the poll frequency to zero (0) will
always fail, an agent may also choose to fail any request to
change the poll frequency to a value that would severely impact
system performance."
::= { cpqSeOsCommon 1 }
cpqSeOsCommonModuleTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeOsCommonModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of software modules that provide an interface to the
device this MIB describes."
::= { cpqSeOsCommon 2 }
cpqSeOsCommonModuleEntry OBJECT-TYPE
SYNTAX CpqSeOsCommonModuleEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a software module that provides an interface
to the device this MIB describes."
INDEX { cpqSeOsCommonModuleIndex }
::= { cpqSeOsCommonModuleTable 1 }
CpqSeOsCommonModuleEntry ::= SEQUENCE {
cpqSeOsCommonModuleIndex INTEGER,
cpqSeOsCommonModuleName DisplayString,
cpqSeOsCommonModuleVersion DisplayString,
cpqSeOsCommonModuleDate OCTET STRING,
cpqSeOsCommonModulePurpose DisplayString
}
cpqSeOsCommonModuleIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index for this module description."
::= { cpqSeOsCommonModuleEntry 1 }
cpqSeOsCommonModuleName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module name."
::= { cpqSeOsCommonModuleEntry 2 }
cpqSeOsCommonModuleVersion OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module version in XX.YY format.
Where XX is the major version number and YY is the minor version
number. This field will be a null (size 0) string if the agent
cannot provide the module version."
::= { cpqSeOsCommonModuleEntry 3 }
cpqSeOsCommonModuleDate OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The module date.
field octets contents range
===== ====== ======= =====
1 1-2 year 0..65536
2 3 month 1..12
3 4 day 1..31
4 5 hour 0..23
5 6 minute 0..59
6 7 second 0..60
(use 60 for leap-second)
This field will be set to year = 0 if the agent cannot provide
the module date. The hour, minute, and second field will be set
to zero (0) if they are not relevant. The year field is set
with the most significant octect first."
::= { cpqSeOsCommonModuleEntry 4 }
cpqSeOsCommonModulePurpose OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The purpose of the module described in this entry."
::= { cpqSeOsCommonModuleEntry 5 }
cpqSeCpuTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeCpuEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of the CPUs (processors) in the system.
The main processor (if such a concept is valid for this machine)
should be the first entry in the table."
::= { cpqSeProcessor 1 }
cpqSeCpuEntry OBJECT-TYPE
SYNTAX CpqSeCpuEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a CPU (processor) in the system."
INDEX { cpqSeCpuUnitIndex }
::= { cpqSeCpuTable 1 }
CpqSeCpuEntry ::= SEQUENCE {
cpqSeCpuUnitIndex INTEGER,
cpqSeCpuSlot INTEGER,
cpqSeCpuName DisplayString,
cpqSeCpuSpeed INTEGER,
cpqSeCpuStep INTEGER,
cpqSeCpuStatus INTEGER,
cpqSeCpuExtSpeed INTEGER,
cpqSeCpuDesigner INTEGER,
cpqSeCpuSocketNumber INTEGER,
cpqSeCpuThreshPassed INTEGER
}
cpqSeCpuUnitIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a number that uniquely specifies a processor unit.
A processing unit may be a set of processing chips that are
on the same board or for other reasons work together as a unit.
The main processor unit (if such a concept is valid for this
machine) will always have the lowest (first) index."
::= { cpqSeCpuEntry 1 }
cpqSeCpuSlot OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value represents this processor's slot.
If the slot cannot be determined the value of zero (0) will be
returned."
::= { cpqSeCpuEntry 2 }
cpqSeCpuName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of this processor.
For example:
80386"
::= { cpqSeCpuEntry 3 }
cpqSeCpuSpeed OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the internal speed in megahertz of this processor.
Zero will be returned if this value is not available."
::= { cpqSeCpuEntry 4 }
cpqSeCpuStep OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This step of the processor.
This will be zero (0) if the step cannot be determined."
::= { cpqSeCpuEntry 5 }
cpqSeCpuStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the processor."
::= { cpqSeCpuEntry 6 }
cpqSeCpuExtSpeed OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the external frequency in megahertz of the processor bus.
Zero will be returned if this value is not available."
::= { cpqSeCpuEntry 7 }
cpqSeCpuDesigner OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
intel(2),
amd(3),
cyrix(4),
ti(5),
nexgen(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute specifies the manafacturer which designs
this CPU."
::= { cpqSeCpuEntry 8 }
cpqSeCpuSocketNumber OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The physical socket number of the CPU chip. This number
helps to identify CPUs on processor boards that contain
multiple CPU chips. In most cases the CPU Socket number
should be specified on the boards silk screen or in product
documentation. A 0 socket number means undetermined."
::= { cpqSeCpuEntry 9 }
cpqSeCpuThreshPassed OBJECT-TYPE
SYNTAX INTEGER
{
unsupported(1),
false(2),
true(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"CPU threshold passed (Exceeded). When this attribute is set
to true, it identifies a pre-failure error condition. Processors
like the Intel Pentium Pro have the capability built into them
to correct internal error conditions. Excessive corrected internal
errors can predict future hard processor failures. Agent
instrumentation will set this attribute to true if an internal
processor error threshold is passed. It is recommended that the
user replace the CPU in this case. If the processor does not
support monitoring internal corrected errors, this value will
be set to unsupported. "
::= { cpqSeCpuEntry 10 }
cpqSeFpuTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeFpuEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of the FPUs (floating point coprocessors) in the system."
::= { cpqSeProcessor 2 }
cpqSeFpuEntry OBJECT-TYPE
SYNTAX CpqSeFpuEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a FPU in the system.
The fpuUnitIndex of any entry in this table will equal the
cpuUnitIndex of the corresponding CPU in the cpqSeCpu table."
INDEX { cpqSeFpuUnitIndex , cpqSeFpuChipIndex }
::= { cpqSeFpuTable 1 }
CpqSeFpuEntry ::= SEQUENCE {
cpqSeFpuUnitIndex INTEGER,
cpqSeFpuChipIndex INTEGER,
cpqSeFpuSlot INTEGER,
cpqSeFpuName DisplayString,
cpqSeFpuSpeed INTEGER,
cpqSeFpuType INTEGER
}
cpqSeFpuUnitIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a number that uniquely specifies a processor unit.
A processing unit may be a set of processing chips that are
on the same board or for other reasons work together as a unit.
The main processor unit (if there is one) will always have the
lowest (first) index. This field can be used to associate
CPUs with their corresponding FPUs."
::= { cpqSeFpuEntry 1 }
cpqSeFpuChipIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a number that uniquely specifies the FPU chip.
This field is used to distinguish between multiple FPUs that are
part of the same processor unit. For example, If a processor
board contained a Intel 80386 processor with both a Intel 80387
and a Weitek 3167, both the 80387 and the 3167 would have the
same fpuUnitIndex (which would match the 80386's cpuUnitIndex)
but the 80387 and the 3167 would have different fpuChipIndex
field values."
::= { cpqSeFpuEntry 2 }
cpqSeFpuSlot OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the FPU's slot.
If the slot cannot be determined the value of zero (0) will
be returned."
::= { cpqSeFpuEntry 3 }
cpqSeFpuName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the name of the FPU.
For example:
80387
Weitek 3167"
::= { cpqSeFpuEntry 4 }
cpqSeFpuSpeed OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is speed in megahertz of the FPU.
Zero will be returned if this value is not available."
::= { cpqSeFpuEntry 5 }
cpqSeFpuType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
embedded(2),
external(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the FPU this entry is describing
is embedded in the CPU or external to the CPU chip."
::= { cpqSeFpuEntry 6 }
cpqSeCpuCacheTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeCpuCacheEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of the CPU caches in the system."
::= { cpqSeProcessor 3 }
cpqSeCpuCacheEntry OBJECT-TYPE
SYNTAX CpqSeCpuCacheEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a CPU Caches in the system."
INDEX { cpqSeCpuCacheUnitIndex, cpqSeCpuCacheLevelIndex }
::= { cpqSeCpuCacheTable 1 }
CpqSeCpuCacheEntry ::= SEQUENCE {
cpqSeCpuCacheUnitIndex INTEGER,
cpqSeCpuCacheLevelIndex INTEGER,
cpqSeCpuCacheSize INTEGER,
cpqSeCpuCacheSpeed INTEGER,
cpqSeCpuCacheStatus INTEGER,
cpqSeCpuCacheWritePolicy INTEGER
}
cpqSeCpuCacheUnitIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a number that uniquely specifies a processor unit.
A processing unit may be a set of processing chips that are
on the same board or for other reasons work together as a unit.
The main processor unit (if such a concept is valid for this
machine) will always have the lowest (first) index."
::= { cpqSeCpuCacheEntry 1 }
cpqSeCpuCacheLevelIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the processor cache level.
The lower the processor cache level, the closer the cache is to
the processor."
::= { cpqSeCpuCacheEntry 2 }
cpqSeCpuCacheSize OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size of the cache in kilobytes."
::= { cpqSeCpuCacheEntry 3 }
cpqSeCpuCacheSpeed OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is speed in cache memory in nanoseconds (ns). A value of
zero (0) means that the cache speed is unknown or unobtainable."
::= { cpqSeCpuCacheEntry 4 }
cpqSeCpuCacheStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the cache unit. If the cache is optional and not
installed, unknown(1) will be returned."
::= { cpqSeCpuCacheEntry 5 }
cpqSeCpuCacheWritePolicy OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
write-through(2),
write-back(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Specifies write policy of this cache entry."
::= { cpqSeCpuCacheEntry 6 }
cpqSeBaseMem OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of base memory in kilobytes.
A kilobyte is 1024 bytes."
::= { cpqSeMemory 1 }
cpqSeTotalMem OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total amount of memory in kilobytes.
A kilobyte is 1024 bytes."
::= { cpqSeMemory 2 }
cpqSeIsaCmosRaw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The contents of the ISA CMOS."
::= { cpqSeIsaCmos 1 }
cpqSeEisaSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeEisaSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of EISA slot information entries."
::= { cpqSeEisaNvram 1 }
cpqSeEisaSlotEntry OBJECT-TYPE
SYNTAX CpqSeEisaSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of an EISA slot."
INDEX { cpqSeEisaSlotIndex }
::= { cpqSeEisaSlotTable 1 }
CpqSeEisaSlotEntry ::= SEQUENCE {
cpqSeEisaSlotIndex INTEGER,
cpqSeEisaSlotRaw OCTET STRING,
cpqSeEisaSlotBoardId DisplayString,
cpqSeEisaSlotBoardName DisplayString,
cpqSeEisaSlotCfRev DisplayString,
cpqSeEisaSlotType INTEGER
}
cpqSeEisaSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot number for this entry describes."
::= { cpqSeEisaSlotEntry 1 }
cpqSeEisaSlotRaw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (12))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot data for the board in this slot.
This octet string contains the following EISA slot information:
The first octet will be zero (0) if this slot contains a
properly configured board. Any other value indicates that the
EISA configuration information for this board is invalid or an
error occurred when trying to retrieve the information.
The second octet contains several bit flags about the product ID
and slot type.
Bit 7: 0 = No duplicate ID
1 = Duplicate IDs
Bit 6: 0 = Product ID readable
1 = Product ID not readable
Bit 5,4: 00 = Expansion slot
01 = Embedded device
10 = Virtual device
11 = Reserved
Bit 3..0: This nibble indicates which CFG file is loaded
when duplicate file names are present.
0000 = No duplicate ID
0001 = First duplicate ID
0010 = Second duplicate ID
0011 = Third duplicate ID
.
.
.
1111 = Fifteenth duplicate ID
NOTE: Bit 7 is the most significant bit, bit 0 is the least
significant.
The third octet contains the major revision level of the
configuration utility.
The fourth octet contains the minor revision level of the
configuration utility.
The fifth octet contains the most significant byte of the
configuration file checksum.
The sixth octet contains the least significant byte of the
configuration file checksum.
The seventh octet contains the number of device functions defined
for the board in this slot.
The eighth octet contains the combined function information.
This is a set of flags. Each bit has the following meaning when
set (1):
Bit 7: reserved (0)
Bit 6: slot has one or more free form data entries
Bit 5: slot has one or more port initialization entries.
Bit 4: slot has one or more port range entries.
Bit 3: slot has one or more DMA entries.
Bit 2: slot has one or more interrupt (IRQ) entries.
Bit 1: slot has one or more memory entries.
Bit 0: slot has one or more function type definitions.
NOTE: bit 7 is the most significant bit, bit 0 is the least
significant.
The ninth, tenth, eleventh, and twelfth octets contain the four
byte compressed EISA ID.
For more information about the meaning of this information
consult the EISA Technical Reference Guide."
::= { cpqSeEisaSlotEntry 2 }
cpqSeEisaSlotBoardId OBJECT-TYPE
SYNTAX DisplayString (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A seven character board ID.
The first three characters are the manufacturers ID followed by
three character product ID followed by a one character revision
level."
::= { cpqSeEisaSlotEntry 3 }
cpqSeEisaSlotBoardName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The product name (or other suitable description) of this board.
This field may be empty if no descriptive information is known
about the board."
::= { cpqSeEisaSlotEntry 4 }
cpqSeEisaSlotCfRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The revision level of the EISA configuration utility that was
used to configure the system.
This should be the same version information displayed by the EISA
configuration utility."
::= { cpqSeEisaSlotEntry 5 }
cpqSeEisaSlotType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
isa8Bit(2),
isa16Bit(3),
eisa32Bit(4),
eisaBusMaster32Bit(5),
other(6),
reserved(7),
reserved2(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of slot described by this entry."
::= { cpqSeEisaSlotEntry 6 }
cpqSeEisaFunctTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeEisaFunctEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list EISA function information entries."
::= { cpqSeEisaNvram 2 }
cpqSeEisaFunctEntry OBJECT-TYPE
SYNTAX CpqSeEisaFunctEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of an EISA function."
INDEX { cpqSeEisaFunctSlotIndex , cpqSeEisaFunctIndex }
::= { cpqSeEisaFunctTable 1 }
CpqSeEisaFunctEntry ::= SEQUENCE {
cpqSeEisaFunctSlotIndex INTEGER,
cpqSeEisaFunctIndex INTEGER,
cpqSeEisaFunctStatus INTEGER,
cpqSeEisaFunctType DisplayString,
cpqSeEisaFunctCfgRev DisplayString,
cpqSeEisaFunctSels OCTET STRING,
cpqSeEisaFunctInfo INTEGER
}
cpqSeEisaFunctSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot of the board that registered this function"
::= { cpqSeEisaFunctEntry 1 }
cpqSeEisaFunctIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of the function this entry describes."
::= { cpqSeEisaFunctEntry 2 }
cpqSeEisaFunctStatus OBJECT-TYPE
SYNTAX INTEGER {
disabled(2),
enabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the function described by this entry."
::= { cpqSeEisaFunctEntry 3 }
cpqSeEisaFunctType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of the function.
The type may be followed by one or more subtype description
fields. Some currently defined types are:
Type Meaning
============== ==================================================
COM Communication device
COM,ASY ISA compatible 8250 based serial port
COM,ASY,FIFO ISA compatible 16550 based serial port (with fifo)
COM,SYN ISA compatible SDLC port
CPU Microprocessor
CPU,8086 8086 compatible microprocessor
CPU,80286 80286 compatible microprocessor
CPU,80386SX 80386SX compatible microprocessor
CPU,80386 80386 compatible microprocessor
CPU,80486 80486 compatible microprocessor
JOY ISA compatible joystick adapter
KEY Keyboard
KEY,nnn,KBD=xx Standard keyboard with nnn keys for country xx
MEM Memory board
MFC Multifunction board
MSD Mass storage device
MSD,DSKCTL ISA compatible fixed disk controller
MSD,FPYCTL ISA compatible floppy disk controller
MSD,TAPCTL Primary tape controller
NET Network board
NPX Numeric coprocessor
NPX,287 Intel 287 numeric coprocessor
NPX,387 Intel 387 numeric coprocessor
NPX,387SX Intel 387SX numeric coprocessor
NPX,W1167 Weitek 1167 numeric coprocessor
NPX,W3167 Weitek 3167 numeric coprocessor
OSE Operating system/environment
OTH Other
PAR ISA compatible parallel port
PAR,BID Bidirectional parallel port
PTR Pointing device
PTR,8042 8042 pointing device (mouse) interface
SYS System board
VID Video board
VID,MDA ISA compatible monochrome adapter
VID,MDA,MGA Hercules monochrome adapter
VID,CGA CGA, no write sync during retrace required
VID,CGA,RTR CGA, write sync during retrace required
VID,EGA ISA compatible EGA adapter
VID,VGA ISA compatible VGA adapter
This list is not intended to be complete. Other types may be
found in this field. This list describes some of the more
common types found, other types should be similarly recognizable
to someone sufficiently knowledgeable about computer hardware."
::= { cpqSeEisaFunctEntry 4 }
cpqSeEisaFunctCfgRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..5))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The revision of the EISA configuration .OVL file used to
configure this board."
::= { cpqSeEisaFunctEntry 5 }
cpqSeEisaFunctSels OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..26))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The selections that were chosen with the EISA CONFIGURATION
UTILITY to create this function."
::= { cpqSeEisaFunctEntry 6 }
cpqSeEisaFunctInfo OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA function information block.
This is a set of flags indicating the resources that are
configured in this EISA function. Each bit has the following
meaning when it is set (1):
Bit 7: Function is disabled
Bit 6: This function contains free-form information.
Bit 5: This function contains port initialization entries.
Bit 4: This function contains port range entries.
Bit 3: This function contains DMA entries.
Bit 2: This function contains interrupt (IRQ) entries.
Bit 1: This function contains memory entries.
Bit 0: This function contains function type definitions.
NOTE: bit 7 is the most significant bit, bit 0 is the least
significant."
::= { cpqSeEisaFunctEntry 7 }
cpqSeEisaMemTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeEisaMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of EISA function memory configuration entries."
::= { cpqSeEisaNvram 3 }
cpqSeEisaMemEntry OBJECT-TYPE
SYNTAX CpqSeEisaMemEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of an EISA function memory configuration."
INDEX { cpqSeEisaMemSlotIndex , cpqSeEisaMemFunctIndex ,
cpqSeEisaMemAllocIndex }
::= { cpqSeEisaMemTable 1 }
CpqSeEisaMemEntry ::= SEQUENCE {
cpqSeEisaMemSlotIndex INTEGER,
cpqSeEisaMemFunctIndex INTEGER,
cpqSeEisaMemAllocIndex INTEGER,
cpqSeEisaMemStartAddr INTEGER,
cpqSeEisaMemSize INTEGER,
cpqSeEisaMemShare INTEGER,
cpqSeEisaMemType INTEGER,
cpqSeEisaMemCache INTEGER,
cpqSeEisaMemAccess INTEGER,
cpqSeEisaMemDecode INTEGER,
cpqSeEisaMemDataSize INTEGER
}
cpqSeEisaMemSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot number of the board that registered the memory
configuration this entry describes."
::= { cpqSeEisaMemEntry 1 }
cpqSeEisaMemFunctIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The function in which this memory configuration was registered."
::= { cpqSeEisaMemEntry 2 }
cpqSeEisaMemAllocIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index for this memory allocation entry in the EISA function
block."
::= { cpqSeEisaMemEntry 3 }
cpqSeEisaMemStartAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The starting address of the memory configuration."
::= { cpqSeEisaMemEntry 4 }
cpqSeEisaMemSize OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size in bytes of the memory configuration."
::= { cpqSeEisaMemEntry 5 }
cpqSeEisaMemShare OBJECT-TYPE
SYNTAX INTEGER {
nonshareable(1),
shareable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the memory is shareable."
::= { cpqSeEisaMemEntry 6 }
cpqSeEisaMemType OBJECT-TYPE
SYNTAX INTEGER {
systemBaseOrExtended(1),
expanded(2),
virtual(3),
other(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of memory."
::= { cpqSeEisaMemEntry 7 }
cpqSeEisaMemCache OBJECT-TYPE
SYNTAX INTEGER {
notCached(1),
writeThroughCached(2),
writeBackCached(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the memory is cached."
::= { cpqSeEisaMemEntry 8 }
cpqSeEisaMemAccess OBJECT-TYPE
SYNTAX INTEGER {
readOnly(1),
readWrite(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of access permitted for this memory."
::= { cpqSeEisaMemEntry 9 }
cpqSeEisaMemDecode OBJECT-TYPE
SYNTAX INTEGER (0..65536)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The memory decode size (the number of address lines supported)."
::= { cpqSeEisaMemEntry 10 }
cpqSeEisaMemDataSize OBJECT-TYPE
SYNTAX INTEGER (0..65536)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The data access size for the memory in bits."
::= { cpqSeEisaMemEntry 11 }
cpqSeEisaIntTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeEisaIntEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of EISA function interrupt configuration entries."
::= { cpqSeEisaNvram 4 }
cpqSeEisaIntEntry OBJECT-TYPE
SYNTAX CpqSeEisaIntEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of an EISA function interrupt configuration."
INDEX { cpqSeEisaIntSlotIndex , cpqSeEisaIntFunctIndex ,
cpqSeEisaIntAllocIndex }
::= { cpqSeEisaIntTable 1 }
CpqSeEisaIntEntry ::= SEQUENCE {
cpqSeEisaIntSlotIndex INTEGER,
cpqSeEisaIntFunctIndex INTEGER,
cpqSeEisaIntAllocIndex INTEGER,
cpqSeEisaIntNum INTEGER,
cpqSeEisaIntShare INTEGER,
cpqSeEisaIntTrigger INTEGER
}
cpqSeEisaIntSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot number of the board that registered the interrupt
configuration this entry describes."
::= { cpqSeEisaIntEntry 1 }
cpqSeEisaIntFunctIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The function in which this interrupt configuration was
registered."
::= { cpqSeEisaIntEntry 2 }
cpqSeEisaIntAllocIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index for this interrupt allocation entry in the EISA
function block."
::= { cpqSeEisaIntEntry 3 }
cpqSeEisaIntNum OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The interrupt described in this entry."
::= { cpqSeEisaIntEntry 4 }
cpqSeEisaIntShare OBJECT-TYPE
SYNTAX INTEGER {
nonshareable(1),
shareable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the interrupt is shareable."
::= { cpqSeEisaIntEntry 5 }
cpqSeEisaIntTrigger OBJECT-TYPE
SYNTAX INTEGER {
edge(1),
level(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the interrupt is edge or level
triggered."
::= { cpqSeEisaIntEntry 6 }
cpqSeEisaDmaTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeEisaDmaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of EISA function DMA configuration entries."
::= { cpqSeEisaNvram 5 }
cpqSeEisaDmaEntry OBJECT-TYPE
SYNTAX CpqSeEisaDmaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of an EISA function DMA configuration."
INDEX { cpqSeEisaDmaSlotIndex , cpqSeEisaDmaFunctIndex ,
cpqSeEisaDmaAllocIndex }
::= { cpqSeEisaDmaTable 1 }
CpqSeEisaDmaEntry ::= SEQUENCE {
cpqSeEisaDmaSlotIndex INTEGER,
cpqSeEisaDmaFunctIndex INTEGER,
cpqSeEisaDmaAllocIndex INTEGER,
cpqSeEisaDmaChannel INTEGER,
cpqSeEisaDmaShare INTEGER,
cpqSeEisaDmaTiming INTEGER,
cpqSeEisaDmaXfer INTEGER,
cpqSeEisaDmaXferCount INTEGER
}
cpqSeEisaDmaSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot number of the board that registered the DMA
configuration this entry describes."
::= { cpqSeEisaDmaEntry 1 }
cpqSeEisaDmaFunctIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The function in which this DMA configuration was registered."
::= { cpqSeEisaDmaEntry 2 }
cpqSeEisaDmaAllocIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index for this DMA channel allocation entry in the EISA
function block."
::= { cpqSeEisaDmaEntry 3 }
cpqSeEisaDmaChannel OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The DMA channel described in this entry."
::= { cpqSeEisaDmaEntry 4 }
cpqSeEisaDmaShare OBJECT-TYPE
SYNTAX INTEGER {
nonshareable(1),
shareable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the DMA channel is shareable."
::= { cpqSeEisaDmaEntry 5 }
cpqSeEisaDmaTiming OBJECT-TYPE
SYNTAX INTEGER {
isaTiming(1),
typeA(2),
typeB(3),
burstTypeC(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the timing (transfer rate) associated with
this configuration of the DMA channel."
::= { cpqSeEisaDmaEntry 6 }
cpqSeEisaDmaXfer OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the transfer size in bits used over this
DMA channel."
::= { cpqSeEisaDmaEntry 7 }
cpqSeEisaDmaXferCount OBJECT-TYPE
SYNTAX INTEGER {
byte(1),
word(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the addessing scheme for the DMA channel."
::= { cpqSeEisaDmaEntry 8 }
cpqSeEisaPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeEisaPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of EISA function port I/O configuration entries."
::= { cpqSeEisaNvram 6 }
cpqSeEisaPortEntry OBJECT-TYPE
SYNTAX CpqSeEisaPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of an EISA function port I/O configuration."
INDEX { cpqSeEisaPortSlotIndex , cpqSeEisaPortFunctIndex ,
cpqSeEisaPortAllocIndex }
::= { cpqSeEisaPortTable 1 }
CpqSeEisaPortEntry ::= SEQUENCE {
cpqSeEisaPortSlotIndex INTEGER,
cpqSeEisaPortFunctIndex INTEGER,
cpqSeEisaPortAllocIndex INTEGER,
cpqSeEisaPortAddr INTEGER,
cpqSeEisaPortShare INTEGER,
cpqSeEisaPortSize INTEGER
}
cpqSeEisaPortSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot number of the board that registered the I/O port
configuration this entry describes."
::= { cpqSeEisaPortEntry 1 }
cpqSeEisaPortFunctIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The function in which this port I/O configuration was
registered."
::= { cpqSeEisaPortEntry 2 }
cpqSeEisaPortAllocIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index for this I/O port range allocation entry in the EISA
function block."
::= { cpqSeEisaPortEntry 3 }
cpqSeEisaPortAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The I/O port address being described in this entry."
::= { cpqSeEisaPortEntry 4 }
cpqSeEisaPortShare OBJECT-TYPE
SYNTAX INTEGER {
nonshareable(1),
shareable(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates if the port is shareable."
::= { cpqSeEisaPortEntry 5 }
cpqSeEisaPortSize OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of sequential ports starting at the
eisaPortAddrIndex that are be configured."
::= { cpqSeEisaPortEntry 6 }
cpqSeEisaFreeFormTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeEisaFreeFormEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of EISA function free form entries."
::= { cpqSeEisaNvram 7 }
cpqSeEisaFreeFormEntry OBJECT-TYPE
SYNTAX CpqSeEisaFreeFormEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of an EISA function free form."
INDEX { cpqSeEisaFreeFormSlotIndex ,
cpqSeEisaFreeFormFunctIndex }
::= { cpqSeEisaFreeFormTable 1 }
CpqSeEisaFreeFormEntry ::= SEQUENCE {
cpqSeEisaFreeFormSlotIndex INTEGER,
cpqSeEisaFreeFormFunctIndex INTEGER,
cpqSeEisaFreeFormValue OCTET STRING
}
cpqSeEisaFreeFormSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot number of the board that registered the free form
information this entry describes."
::= { cpqSeEisaFreeFormEntry 1 }
cpqSeEisaFreeFormFunctIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The function in which this free form was registered."
::= { cpqSeEisaFreeFormEntry 2 }
cpqSeEisaFreeFormValue OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..205))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The free form value."
::= { cpqSeEisaFreeFormEntry 3 }
cpqSeEisaInitTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeEisaInitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of EISA function port initialization entries."
::= { cpqSeEisaNvram 8 }
cpqSeEisaInitEntry OBJECT-TYPE
SYNTAX CpqSeEisaInitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of an EISA function port initialization."
INDEX { cpqSeEisaInitSlotIndex , cpqSeEisaInitFunctIndex ,
cpqSeEisaInitAllocIndex }
::= { cpqSeEisaInitTable 1 }
CpqSeEisaInitEntry ::= SEQUENCE {
cpqSeEisaInitSlotIndex INTEGER,
cpqSeEisaInitFunctIndex INTEGER,
cpqSeEisaInitAllocIndex INTEGER,
cpqSeEisaInitUseMask INTEGER,
cpqSeEisaInitAccess INTEGER,
cpqSeEisaInitAddr INTEGER,
cpqSeEisaInitValue INTEGER,
cpqSeEisaInitMask INTEGER
}
cpqSeEisaInitSlotIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The EISA slot number of the board that registered the port
initialization this entry describes."
::= { cpqSeEisaInitEntry 1 }
cpqSeEisaInitFunctIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The function in which this port initialization was registered."
::= { cpqSeEisaInitEntry 2 }
cpqSeEisaInitAllocIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The index for this port initialization entry in the EISA
function block."
::= { cpqSeEisaInitEntry 3 }
cpqSeEisaInitUseMask OBJECT-TYPE
SYNTAX INTEGER {
useValueOnly(1),
useValueAndMask(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This indicates if a mask will be used when performing
initialization."
::= { cpqSeEisaInitEntry 4 }
cpqSeEisaInitAccess OBJECT-TYPE
SYNTAX INTEGER {
other(1),
eightBitAddress(2),
sixteenBitAddress(3),
thirtyTwoBitAddress(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the number of bits this entry initializes."
::= { cpqSeEisaInitEntry 5 }
cpqSeEisaInitAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the port address this entry initializes."
::= { cpqSeEisaInitEntry 6 }
cpqSeEisaInitValue OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This indicates the value to which this port is initialized."
::= { cpqSeEisaInitEntry 7 }
cpqSeEisaInitMask OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value indicates the mask to use when performing
initialization."
::= { cpqSeEisaInitEntry 8 }
cpqSeSysRomVer OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"System ROM version information."
::= { cpqSeRom 1 }
cpqSeOptRomTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeOptRomEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of option ROM descriptions."
::= { cpqSeRom 2 }
cpqSeOptRomEntry OBJECT-TYPE
SYNTAX CpqSeOptRomEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An option ROM description."
INDEX { cpqSeOptRomAddrIndex }
::= { cpqSeOptRomTable 1 }
CpqSeOptRomEntry ::= SEQUENCE {
cpqSeOptRomAddrIndex INTEGER,
cpqSeOptRomSize INTEGER
}
cpqSeOptRomAddrIndex OBJECT-TYPE
SYNTAX INTEGER (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The starting address of the option ROM.
This value indicates the number of bytes from the start of
physical memory to the beginning of this option ROM."
::= { cpqSeOptRomEntry 1 }
cpqSeOptRomSize OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The size in bytes of the option ROM."
::= { cpqSeOptRomEntry 2 }
cpqSeBiosRomDataRaw OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (256))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The BIOS ROM data area. This may be the current contents or
a copy of the BIOS ROM data area from when the Insight Agent was
initialized."
::= { cpqSeRom 3 }
cpqSeKeyboardDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the keyboard."
::= { cpqSeKeyboard 1 }
cpqSeVideoDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A description of the video system in the computer. This may
include the manufacturer, board name, modes supported, etc.."
::= { cpqSeVideo 1 }
cpqSeSerialPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeSerialPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of serial port descriptions."
::= { cpqSeSerialPort 1 }
cpqSeSerialPortEntry OBJECT-TYPE
SYNTAX CpqSeSerialPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a serial port."
INDEX { cpqSeSerialPortIndex }
::= { cpqSeSerialPortTable 1 }
CpqSeSerialPortEntry ::= SEQUENCE {
cpqSeSerialPortIndex INTEGER,
cpqSeSerialPortAddr INTEGER,
cpqSeSerialPortDesc DisplayString
}
cpqSeSerialPortIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry."
::= { cpqSeSerialPortEntry 1 }
cpqSeSerialPortAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The I/O port address used by this serial port."
::= { cpqSeSerialPortEntry 2 }
cpqSeSerialPortDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A text description of further information known about the serial
port. This may be an empty string if no further information is
known."
::= { cpqSeSerialPortEntry 3 }
cpqSeParallelPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeParallelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of parallel port descriptions."
::= { cpqSeParallelPort 1 }
cpqSeParallelPortEntry OBJECT-TYPE
SYNTAX CpqSeParallelPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a parallel port."
INDEX { cpqSeParallelPortIndex }
::= { cpqSeParallelPortTable 1 }
CpqSeParallelPortEntry ::= SEQUENCE {
cpqSeParallelPortIndex INTEGER,
cpqSeParallelPortAddr INTEGER,
cpqSeParallelPortDesc DisplayString
}
cpqSeParallelPortIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry."
::= { cpqSeParallelPortEntry 1 }
cpqSeParallelPortAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The I/O port address used by this parallel port."
::= { cpqSeParallelPortEntry 2 }
cpqSeParallelPortDesc OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A text description of further information known about the
parallel port. This may be an empty string if no further
information is known."
::= { cpqSeParallelPortEntry 3 }
cpqSeFloppyDiskTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeFloppyDiskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of floppy drive descriptions."
::= { cpqSeFloppyDisk 1 }
cpqSeFloppyDiskEntry OBJECT-TYPE
SYNTAX CpqSeFloppyDiskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A floppy drive description."
INDEX { cpqSeFloppyDiskIndex }
::= { cpqSeFloppyDiskTable 1 }
CpqSeFloppyDiskEntry ::= SEQUENCE {
cpqSeFloppyDiskIndex INTEGER,
cpqSeFloppyDiskType INTEGER
}
cpqSeFloppyDiskIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry. If possible, this
field will map directly to the drive letter (0 for A:, 1 for B:)."
::= { cpqSeFloppyDiskEntry 1 }
cpqSeFloppyDiskType OBJECT-TYPE
SYNTAX INTEGER {
other(1),
drive360k(2),
drive1200k(3),
drive720k(4),
drive1440k(5),
drive120mb(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type (capacity) of the floppy drive. The following values
are valid:
other (1) This floppy drive could not be identified.
drive360k (2) This is a 360 kilobyte, 5.25 inch floppy drive.
drive1200k (3) This is a 1.2 megabyte, 5.25 inch floppy drive.
drive720k (4) This is a 720 kilobyte, 3.5 inch floppy drive.
drive1440k (5) This is a 1.44 megabyte, 3.5 inch floppy drive.
drive120mb(6) This is a 120 megabyte, 3.5 inch floptical
drive."
::= { cpqSeFloppyDiskEntry 2 }
cpqSeFixedDiskTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSeFixedDiskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A table of ST-506 interface accessible fixed disk descriptions."
::= { cpqSeFixedDisk 1 }
cpqSeFixedDiskEntry OBJECT-TYPE
SYNTAX CpqSeFixedDiskEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A fixed disk description."
INDEX { cpqSeFixedDiskIndex }
::= { cpqSeFixedDiskTable 1 }
CpqSeFixedDiskEntry ::= SEQUENCE {
cpqSeFixedDiskIndex INTEGER,
cpqSeFixedDiskType INTEGER,
cpqSeFixedDiskCyls INTEGER,
cpqSeFixedDiskHeads INTEGER,
cpqSeFixedDiskSectors INTEGER,
cpqSeFixedDiskCapacity INTEGER
}
cpqSeFixedDiskIndex OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An index that uniquely specifies this entry. Each possible
index value indicates a specific drive as shown in the table
below:
fixedDiskIndex IDE/ESDI Controller Drive Unit
============= =================== ==========
0 Primary 1
1 Primary 2
2 Secondary 1
3 Secondary 2
Any other index value would be implementation specific."
::= { cpqSeFixedDiskEntry 1 }
cpqSeFixedDiskType OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The drive type."
::= { cpqSeFixedDiskEntry 2 }
cpqSeFixedDiskCyls OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of cylinders on the drive."
::= { cpqSeFixedDiskEntry 3 }
cpqSeFixedDiskHeads OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of heads on the drive."
::= { cpqSeFixedDiskEntry 4 }
cpqSeFixedDiskSectors OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of sectors per track on the drive."
::= { cpqSeFixedDiskEntry 5 }
cpqSeFixedDiskCapacity OBJECT-TYPE
SYNTAX INTEGER (0..2147483647)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The capacity of the drive in megabytes."
::= { cpqSeFixedDiskEntry 6 }
cpqSePciSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSePciSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PCI slot information entries."
::= { cpqSePci 1}
cpqSePciSlotEntry OBJECT-TYPE
SYNTAX CpqSePciSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of a PCI slot."
INDEX { cpqSePciSlotBusNumberIndex , cpqSePciSlotDeviceNumberIndex}
::= { cpqSePciSlotTable 1 }
CpqSePciSlotEntry ::= SEQUENCE {
cpqSePciSlotBusNumberIndex INTEGER,
cpqSePciSlotDeviceNumberIndex INTEGER,
cpqSePciPhysSlot INTEGER,
cpqSePciSlotSubSystemID DisplayString,
cpqSePciSlotBoardName DisplayString
}
cpqSePciSlotBusNumberIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PCI bus number for this device."
::= { cpqSePciSlotEntry 1 }
cpqSePciSlotDeviceNumberIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A number that uniquely identifies this device on its PCI bus."
::= { cpqSePciSlotEntry 2 }
cpqSePciPhysSlot OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The physical PCI slot number of this device. Embedded devices
will return 0 for this variable."
::= { cpqSePciSlotEntry 3 }
cpqSePciSlotSubSystemID OBJECT-TYPE
SYNTAX DisplayString (SIZE (7))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Uniquely identifies the board configured in this slot. A zero
length ID indicates the Subsystem ID is not supported and the
(Device ID/Vendor ID) should be used for identification purposes
. An ID of all 0xFFh indicates an empty slot."
::= { cpqSePciSlotEntry 4 }
cpqSePciSlotBoardName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The product name (or other suitable description) of this PCI
board. This field may be empty if no descriptive information
is known about the board."
::= { cpqSePciSlotEntry 5 }
cpqSePciFunctTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSePciFunctEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PCI function information entries."
::= { cpqSePci 2}
cpqSePciFunctEntry OBJECT-TYPE
SYNTAX CpqSePciFunctEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of the functions in each PCI slot."
INDEX { cpqSePciFunctBusNumberIndex, cpqSePciFunctDeviceNumberIndex,
cpqSePciFunctIndex }
::= { cpqSePciFunctTable 1 }
CpqSePciFunctEntry ::= SEQUENCE {
cpqSePciFunctBusNumberIndex INTEGER,
cpqSePciFunctDeviceNumberIndex INTEGER,
cpqSePciFunctIndex INTEGER,
cpqSePciFunctClassCode OCTET STRING,
cpqSePciFunctClassDescription DisplayString,
cpqSePciFunctDeviceID INTEGER,
cpqSePciFunctVendorID INTEGER,
cpqSePciFunctRevID INTEGER,
cpqSePciFunctIntLine INTEGER,
cpqSePciFunctDevStatus INTEGER
}
cpqSePciFunctBusNumberIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PCI bus number for this device function."
::= { cpqSePciFunctEntry 1 }
cpqSePciFunctDeviceNumberIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device index for this function."
::= { cpqSePciFunctEntry 2 }
cpqSePciFunctIndex OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The unique index that specifies this function."
::= { cpqSePciFunctEntry 3 }
cpqSePciFunctClassCode OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..3))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The class code register as defined in the PCI Local
Bus Specification in the following format:
Octet Register
----- --------
1 Programming Interface
2 Sub-class code
3 Base class code"
::= { cpqSePciFunctEntry 4 }
cpqSePciFunctClassDescription OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A text string which describes the PCI Base Class and
Sub Class to which this device belongs. This field
may empty if no descriptive information is known about
this function's class."
::= { cpqSePciFunctEntry 5 }
cpqSePciFunctDeviceID OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable identifies this particular device. This
identifier is allocated by the component manufacturer."
::= { cpqSePciFunctEntry 6 }
cpqSePciFunctVendorID OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable identifies the component manufacturer. Valid
identifiers are assigned by the PCI SIG."
::= { cpqSePciFunctEntry 7 }
cpqSePciFunctRevID OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is a vendor defined extension to the device ID and
specifies a device specific revision identifier."
::= { cpqSePciFunctEntry 8}
cpqSePciFunctIntLine OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable specifies which input of the system interrupt
controller(s) the device's interrupt pin is connected to.
A value of 0ffh means unknown or no connection."
::= { cpqSePciFunctEntry 9}
cpqSePciFunctDevStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
enabled(2),
disabled(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The status of the device described by this function.
Some PCI devices, such as embedded devices, have the
potential of being present but disabled. "
::= { cpqSePciFunctEntry 10 }
cpqSePciMemoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSePciMemoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PCI base memory entries"
::= { cpqSePci 3}
cpqSePciMemoryEntry OBJECT-TYPE
SYNTAX CpqSePciMemoryEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A description of the base memory usage in each function"
INDEX { cpqSePciMemoryBusNumberIndex, cpqSePciMemoryDeviceNumberIndex,
cpqSePciMemoryFunctionIndex, cpqSePciMemoryIndex }
::= { cpqSePciMemoryTable 1 }
CpqSePciMemoryEntry ::= SEQUENCE {
cpqSePciMemoryBusNumberIndex INTEGER,
cpqSePciMemoryDeviceNumberIndex INTEGER,
cpqSePciMemoryFunctionIndex INTEGER,
cpqSePciMemoryIndex INTEGER,
cpqSePciMemoryBaseAddr INTEGER,
cpqSePciMemoryType INTEGER,
cpqSePciMemorySize INTEGER
}
cpqSePciMemoryBusNumberIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PCI bus number for this memory entry."
::= { cpqSePciMemoryEntry 1 }
cpqSePciMemoryDeviceNumberIndex OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The device index for this memory entry"
::= { cpqSePciMemoryEntry 2 }
cpqSePciMemoryFunctionIndex OBJECT-TYPE
SYNTAX INTEGER (0..7)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The unique index that specifies the function associated
with this memory entry."
::= { cpqSePciMemoryEntry 3 }
cpqSePciMemoryIndex OBJECT-TYPE
SYNTAX INTEGER (0..6)
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The unique index that specifies this memory entry. "
::= { cpqSePciMemoryEntry 4 }
cpqSePciMemoryBaseAddr OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Base address of this memory usage entry."
::= { cpqSePciMemoryEntry 5 }
cpqSePciMemoryType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
io(2),
memory-mapped(3),
exp-rom(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of memory this entry describes. This variable
is used to determine if this memory entry maps into
memory, expansion rom or I/O space."
::= { cpqSePciMemoryEntry 6 }
cpqSePciMemorySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable specifies how much address space this function
requires. A value of 0 will be returned if the agent cannot
obtain this information."
::= { cpqSePciMemoryEntry 7 }
cpqSePCCardSlotTable OBJECT-TYPE
SYNTAX SEQUENCE OF CpqSePCCardSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of PC Card slot information entries."
::= { cpqSePCCard 1}
cpqSePCCardSlotEntry OBJECT-TYPE
SYNTAX CpqSePCCardSlotEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A PC Card slot description table entry.
A table entry is defined for each PC Card Slot in the
current system configuration."
INDEX { cpqSePCCardSlotIndex}
::= { cpqSePCCardSlotTable 1 }
CpqSePCCardSlotEntry ::= SEQUENCE {
cpqSePCCardSlotIndex INTEGER,
cpqSePCCardCondition INTEGER,
cpqSePCCardPhysLocation DisplayString,
cpqSePCCardSlotType INTEGER,
cpqSePCCardSlotWidth INTEGER,
cpqSePCCardSlotThermalCapacity INTEGER,
cpqSePCCardSlotThermalSensor INTEGER,
cpqSePCCardSlotPowerState INTEGER,
cpqSePCCardStatus INTEGER,
cpqSePCCardDeviceInfo DisplayString,
cpqSePCCardProductInfo DisplayString,
cpqSePCCardSerialNumber DisplayString,
cpqSePCCardAssetTag DisplayString
}
cpqSePCCardSlotIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the logical PC Card slot number for this PC Card Slot.
In addition, the slot number serves as the index into the
PC Card data table. Typical index ranges will be either 1 to
4 (for 4 slots) or 1 to 2 (for 2 slots). (Un)Docking may
cause the supported index range to change dynamically."
::= { cpqSePCCardSlotEntry 1 }
cpqSePCCardCondition OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
degraded(3),
failed(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the overall condition of the PC Card.
The supported values are defined as follows:
unknown(1)
The current condition is unknown for the PC Card or PC Card Slot.
ok(2)
PC Card operations are normal.
No user action required.
degraded (3)
PC Card operations have degraded.
Consult the cpqSePCCardStatus field for recommended actions.
failed (4)
PC Card operations have failed.
Consult the cpqSePCCardStatus field for recommended actions."
::= { cpqSePCCardSlotEntry 2 }
cpqSePCCardPhysLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the user level PC Card Slot location description.
Text strings supported are:
- System Unit Top Slot,
- System Unit Bottom Slot,
- Docking Station Top Slot,
- Docking Station Bottom Slot."
::= { cpqSePCCardSlotEntry 3 }
cpqSePCCardSlotType OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the PC Card Slot capabilities.
This is a bit mapped value defined by DMI Mobile Supplement for the System Slots Group,
Slot Type. Bits of interest for PC Card support are:
Bit 6 - PCMCIA slot (if set),
Bit 13 - 16 bit PC Card capable (if set),
Bit 14 - CardBus PC Card capable (if set),
Bit 15 - ZV Port capable (if set),
Bit 16 - Modem Ring Resume capable (if set),
All other bits should be zero (reset) for PC Card slots."
::= { cpqSePCCardSlotEntry 4 }
cpqSePCCardSlotWidth OBJECT-TYPE
SYNTAX INTEGER {
other(1),
unknown(2),
width8bit(3),
width16bit(4),
width32bit(5),
width64bit(6),
width128bit(7)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the maximum bus width for this PC Card Slot.
The supported values are defined as follows:
Other (1)
Value is not in defined list.
Unknown (2)
Actual value is not known.
width 8 bit (3)
Bus is 8 bits wide.
width 16 bit (4)
Bus is 16 bits wide.
width 32 bit (5)
Bus is 32 bits wide.
width 64 bit (6)
Bus is 64 bits wide.
width 128 bit (7)
Bus is 128 bits wide."
::= { cpqSePCCardSlotEntry 5 }
cpqSePCCardSlotThermalCapacity OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the maximum thermal dissipation capacity (milliwatts)
for this PC Card Slot. A value of zero indicates the thermal
capacity is unknown. A non-zero value indicates the thermal
capacity in milliwatts."
::= { cpqSePCCardSlotEntry 6 }
cpqSePCCardSlotThermalSensor OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the Thermal Sensor ID that monitors this PC Card Slot.
A value of zero indicates that a sensor is not present or
unknown for this slot. A non-zero value indicates the sensor
ID as defined by the platform firmware."
::= { cpqSePCCardSlotEntry 7 }
cpqSePCCardSlotPowerState OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
on(2),
off(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the current power state (On/Off) for this PC Card Slot.
The supported values are defined as follows:
unknown (1)
Current power state is unknown.
on (2)
Power is currently on.
off (3)
Power is currently off."
::= { cpqSePCCardSlotEntry 8 }
cpqSePCCardStatus OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
ok(2),
thermalDegraded(3),
thermalFailure(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the operating status for the card in this PC Card Slot.
The supported values are defined as follows:
unknown (1)
The current status is not known for the PC Card or
PC Card Slot.
ok (2)
PC Card operations are normal.
No user action required.
thermalDegraded (3)
PC Card operations have degraded due to unsafe thermal
conditions.
Recommended Actions include:
Discontinue the use of the PC Card as soon as
possible. If a Modem or LAN card then close
all communication applications/links. If a
Memory, ATA, or SCSI device then close all
open/related files. Remove PC Card from slot
after use is discontinued, if possible.
thermalFailure (4)
PC Card operations have failed due to unsafe thermal
conditions. The PC Card will automatically be powered
off to protect itself and the system.
Recommended Actions include:
Discontinue the use of the PC Card immediately.
If a Modem or LAN card then close all communication applications/links.
If a Memory, ATA, or SCSI device then close all open/related files.
Remove PC Card from slot after use is discontinued, if possible."
::= { cpqSePCCardSlotEntry 9 }
cpqSePCCardDeviceInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the PC Card Manufacturer / Device information for
the card in this PC Card Slot. The returned string data is
read from the PC Card's onboard Card Information Structure
(CIS)."
::= { cpqSePCCardSlotEntry 10 }
cpqSePCCardProductInfo OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the PC Card Model / Part Number information for
the card in this PC Card Slot. The returned string data
is read from the PC Card's onboard Card Information
Structure (CIS)."
::= { cpqSePCCardSlotEntry 11 }
cpqSePCCardSerialNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the PC Card Serial Number information for the
card in this PC Card Slot. The returned string data is
read from the PC Card's onboard Card Information Structure
(CIS)."
::= { cpqSePCCardSlotEntry 12 }
cpqSePCCardAssetTag OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..80))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the PC Card Asset Tag information for the card in
this PC Card Slot. The returned string data is read from
the PC Card's onboard Card Information Structure (CIS)."
::= { cpqSePCCardSlotEntry 13 }
cpqSeCpuThresholdPassed TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSeCpuSlot, cpqSeCpuSocketNumber}
DESCRIPTION
"This trap is sent when an internal CPU error threshold has been
passed on a particular CPU causing it to go degraded. This trap
will be sent when cpqSeCpuThreshPassed transitions from false to
true."
::= 1001
cpqSePCCardThermalDegraded TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
DESCRIPTION
"This trap is sent when the PC Card Slot Thermal Sensor threshold has been
exceeded for safe operations thereby causing degraded operations. This trap
will be sent when cpqSePCCardStatus transitions from Normal (1) to Thermal
Degraded (2).
The manufacturer and product information strings as well as the slot number
for the degraded PC Card is provided as parameters for this trap."
::= 1002
cpqSePCCardThermalFailure TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSePCCardDeviceInfo,
cpqSePCCardProductInfo, cpqSePCCardSlotIndex }
DESCRIPTION
"This trap is sent when the PC Card Slot Thermal Sensor threshold has been
exceeded for degraded operations thereby causing failed operations.
This trap will be sent when cpqSePCCardStatus transitions from Thermal Degraded
(2) to Thermal Failure (3).
The manufacturer and product information strings as well as the slot number
for the failed PC Card is provided as parameters for this trap."
::= 1003
cpqSePCCardThermalSafe TRAP-TYPE
ENTERPRISE compaq
VARIABLES { sysName, cpqHoTrapFlags, cpqSePCCardSlotIndex }
DESCRIPTION
"This trap is sent when the PC Card Slot Thermal Sensor threshold has been
crossed which restored the thermal status to normal operations. This trap will be sent
when cpqSePCCardStatus transitions from Thermal Degraded (2) or Thermal Failure
(3) to Normal (1).
The number of the recovered PC Card slot is provided as a parameter for this trap."
::= 1004
END