ECX25EXT-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, enterprises, Gauge, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
eicon OBJECT IDENTIFIER ::= { enterprises 434 }
management OBJECT IDENTIFIER ::= { eicon 2 }
mibv2 OBJECT IDENTIFIER ::= { management 2 }
module OBJECT IDENTIFIER ::= { mibv2 4 }
x25ext OBJECT IDENTIFIER ::= { module 5 }
EntryStatus ::= INTEGER
{ valid(1),
createRequest(2),
underCreation(3),
invalid(4)
}
PositiveInteger ::= INTEGER (0..2147483647)
DisplayString ::= OCTET STRING
IfIndexType ::= INTEGER (1..2147483647)
X121Address ::= OCTET STRING (SIZE(0..17))
x25CountersTable OBJECT-TYPE
SYNTAX SEQUENCE OF X25CountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Runtime counters table, one row per port"
::= { x25ext 1 }
x25CountEntry OBJECT-TYPE
SYNTAX X25CountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The set of counters for one port."
INDEX { x25CountPortRef }
::= { x25CountersTable 1 }
X25CountEntry ::= SEQUENCE {
x25CountPortRef
INTEGER,
x25RestartReqTxs
Counter,
x25RestartReqRxs
Counter,
x25ClearReqTxs
Counter,
x25ClearReqRxs
Counter,
x25ResetReqTxs
Counter,
x25ResetReqRxs
Counter,
x25InterrReqTxs
Counter,
x25InterrReqRxs
Counter,
x25RNRsTxs
Counter,
x25RNRsRxs
Counter,
x25REJsTxs
Counter,
x25REJsRxs
Counter,
x25CallConfirmTxs
Counter,
x25CallConfirmRxs
Counter,
x25RRTxs
Counter,
x25RRRxs
Counter,
x25IntConfirmTxs
Counter,
x25IntConfirmRxs
Counter,
x25ClrConfirmTxs
Counter,
x25ClrConfirmRxs
Counter,
x25ResetConfirmTxs
Counter,
x25ResetConfirmRxs
Counter,
x25RestartConfirmTxs
Counter,
x25RestartConfirmRxs
Counter,
x25CallReqTxs
Counter,
x25CallReqRxs
Counter,
x25RegisterReqTxs
Counter,
x25RegisterReqRxs
Counter,
x25RegisterConfirmTxs
Counter,
x25RegisterConfirmRxs
Counter,
x25DataSegmentsTxs
Counter,
x25DataSegmentsRxs
Counter,
x25CaractersTxs
Counter,
x25CaractersRxs
Counter,
x25DiagnosticPktsTxs
Counter,
x25DiagnosticPktsRxs
Counter,
x25UnknownPktsTxs
Counter,
x25UnknownPktsRxs
Counter
}
x25CountPortRef OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Port reference on which the X25 is running."
::= { x25CountEntry 1 }
x25RestartReqTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Restart request frames transmitted"
::= { x25CountEntry 2 }
x25RestartReqRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Restart request frames received"
::= { x25CountEntry 3 }
x25ClearReqTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clear request frames transmitted "
::= { x25CountEntry 4 }
x25ClearReqRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clear request frames received"
::= { x25CountEntry 5 }
x25ResetReqTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reset request frames transmitted"
::= { x25CountEntry 6 }
x25ResetReqRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reset request frames received "
::= { x25CountEntry 7 }
x25InterrReqTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interrupt request frames transmitted "
::= { x25CountEntry 8 }
x25InterrReqRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interrupt request frames received "
::= { x25CountEntry 9 }
x25RNRsTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receiver not ready frames transmitted"
::= { x25CountEntry 10 }
x25RNRsRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receiver not ready frames received"
::= { x25CountEntry 11 }
x25REJsTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reject frames transmitted "
::= { x25CountEntry 12 }
x25REJsRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reject frames received "
::= { x25CountEntry 13 }
x25CallConfirmTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Call confirm transmitted. "
::= { x25CountEntry 14 }
x25CallConfirmRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Call confirm received. "
::= { x25CountEntry 15 }
x25RRTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receiver ready transmitted "
::= { x25CountEntry 16 }
x25RRRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Receiver ready received "
::= { x25CountEntry 17 }
x25IntConfirmTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interrupt confirm transmitted"
::= { x25CountEntry 18 }
x25IntConfirmRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interrupt confirm received"
::= { x25CountEntry 19 }
x25ClrConfirmTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clear confirmation transmitted."
::= { x25CountEntry 20 }
x25ClrConfirmRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Clear confirmation received."
::= { x25CountEntry 21 }
x25ResetConfirmTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reset confirm transmitted."
::= { x25CountEntry 22 }
x25ResetConfirmRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Reset confirm received."
::= { x25CountEntry 23 }
x25RestartConfirmTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Restart confirm transmitted. "
::= { x25CountEntry 24 }
x25RestartConfirmRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Restart confirm received. "
::= { x25CountEntry 25 }
x25CallReqTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of requests transmitted for a connection."
::= { x25CountEntry 26 }
x25CallReqRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of requests received for a connection."
::= { x25CountEntry 27 }
x25RegisterReqTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of register packets sent. Register packets
are used to exchange registration information."
::= { x25CountEntry 28 }
x25RegisterReqRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of register packets received. "
::= { x25CountEntry 29 }
x25RegisterConfirmTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Register confirm transmitted. "
::= { x25CountEntry 30 }
x25RegisterConfirmRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Register confirm received. "
::= { x25CountEntry 31 }
x25DataSegmentsTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of 64 bytes data blocks sent. "
::= { x25CountEntry 32 }
x25DataSegmentsRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of 64 bytes data blocks received. "
::= { x25CountEntry 33 }
x25CaractersTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of characters sent. "
::= { x25CountEntry 34 }
x25CaractersRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of characters received. "
::= { x25CountEntry 35 }
x25DiagnosticPktsTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of error information packets sent."
::= { x25CountEntry 36 }
x25DiagnosticPktsRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of error information packets received."
::= { x25CountEntry 37 }
x25UnknownPktsTxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that could not be recognized as
following the X.25 structure sent."
::= { x25CountEntry 38 }
x25UnknownPktsRxs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets that could not be recognized as
following the X.25 structure received."
::= { x25CountEntry 39 }
x25VCCallParmTable OBJECT-TYPE
SYNTAX SEQUENCE OF X25VCCallParmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains only the objects of the Internet
x25CallParmTable which are available from the EiconCard.
For the complete description of x25CallParmTable,
please refer to RFC1382."
::= { x25ext 2 }
x25VCCallParmEntry OBJECT-TYPE
SYNTAX X25VCCallParmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries of x25VCCallParmTable."
INDEX { x25VCCallParmPortIndex,
x25VCCallParmVCIndex }
::= { x25VCCallParmTable 1 }
X25VCCallParmEntry ::= SEQUENCE {
x25VCCallParmPortIndex
INTEGER,
x25VCCallParmVCIndex
INTEGER,
x25VCCallParmInPacketSize
INTEGER,
x25VCCallParmOutPacketSize
INTEGER,
x25VCCallParmInWindowSize
INTEGER,
x25VCCallParmOutWindowSize
INTEGER,
x25VCCallParmUserData
OCTET STRING,
x25VCCallParmCallingNetworkFacilities
OCTET STRING,
x25VCCallParmCalledNetworkFacilities
OCTET STRING
}
x25VCCallParmPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Port reference on which the X25 is running."
::= { x25VCCallParmEntry 1 }
x25VCCallParmVCIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Virtual Circuits."
::= { x25VCCallParmEntry 2 }
x25VCCallParmInPacketSize OBJECT-TYPE
SYNTAX INTEGER (0..4096)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum receive packet size in octets
for a circuit. A size of zero for a circuit
means use the PLE default size. A size of
zero for the PLE means use a default size of
128."
REFERENCE "10733 proposedPacketSize;
See ISO 8208 Section 15.2.2.1.1"
DEFVAL { 128 }
::= { x25VCCallParmEntry 3 }
x25VCCallParmOutPacketSize OBJECT-TYPE
SYNTAX INTEGER (0..4096)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum transmit packet size in octets
for a circuit. A size of zero for a circuit
means use the PLE default size. A size of
zero for the PLE default means use a default
size of 128."
REFERENCE "10733 proposedPacketSize;
See ISO 8208 Section 15.2.2.1.1"
DEFVAL { 128 }
::= { x25VCCallParmEntry 4 }
x25VCCallParmInWindowSize OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The receive window size for a circuit. A
size of zero for a circuit means use the PLE
default size. A size of zero for the PLE
default means use 2."
REFERENCE "10733 proposedWindowSize;
See ISO 8208 Section 15.2.2.1.2"
DEFVAL { 2 }
::= { x25VCCallParmEntry 5 }
x25VCCallParmOutWindowSize OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The transmit window size for a circuit. A
size of zero for a circuit means use the PLE
default size. A size of zero for the PLE
default means use 2."
REFERENCE "10733 proposedWindowSize;
See ISO 8208 Section 15.2.2.1.2"
DEFVAL { 2 }
::= { x25VCCallParmEntry 6 }
x25VCCallParmUserData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The call user data as placed in the packet.
A zero length string indicates no call user
data. If both the circuit call parameters
and the PLE default have call user data
defined, the data from the circuit call
parameters will be used. If only the PLE
has data defined, the PLE entry will be
used. If neither the circuit call
parameters or the PLE default entry has a
value, no call user data will be sent."
REFERENCE "See ISO 8208 Section 12.2.1.1.6, 12.2.1.2"
DEFVAL { ''h }
::= { x25VCCallParmEntry 7 }
x25VCCallParmCallingNetworkFacilities OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..108))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The calling network facilities. The
facilities are encoded here exactly as
encoded in the call packet. These
facilities do not include the marker
facility code.
A zero length string in the entry for the
parameter to use when establishing a circuit
means use the PLE default. A zero length
string in the entry for PLE default
parameters indicates no default facilities."
REFERENCE "See ISO 8206 Section 15.1, category b"
DEFVAL { ''h }
::= { x25VCCallParmEntry 8 }
x25VCCallParmCalledNetworkFacilities OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..108))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The called network facilities. The
facilities are encoded here exactly as
encoded in the call packet. These
facilities do not include the marker
facility code.
A zero length string in the entry for the
parameter to use when establishing a circuit
means use the PLE default. A zero length
string in the entry for PLE default
parameters indicates no default facilities."
REFERENCE "See ISO 8206 Section 15.1, category c"
DEFVAL { ''h }
::= { x25VCCallParmEntry 9 }
x25OperTable OBJECT-TYPE
SYNTAX SEQUENCE OF X25OperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The operation parameters in use by the X.25
PLE."
::= { x25ext 3 }
x25OperEntry OBJECT-TYPE
SYNTAX X25OperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries of x25OperTable."
INDEX { x25OperIndex }
::= { x25OperTable 1 }
X25OperEntry ::= SEQUENCE {
x25OperIndex
INTEGER,
x25OperInterfaceMode
INTEGER,
x25OperMaxActiveCircuits
INTEGER,
x25OperPacketSequencing
INTEGER,
x25OperRestartTimer
PositiveInteger,
x25OperCallTimer
PositiveInteger,
x25OperResetTimer
PositiveInteger,
x25OperClearTimer
PositiveInteger,
x25OperWindowTimer
PositiveInteger,
x25OperDataRxmtTimer
PositiveInteger,
x25OperInterruptTimer
PositiveInteger,
x25OperRejectTimer
PositiveInteger,
x25OperRegistrationRequestTimer
PositiveInteger,
x25OperMinimumRecallTimer
PositiveInteger,
x25OperRestartCount
INTEGER,
x25OperResetCount
INTEGER,
x25OperClearCount
INTEGER,
x25OperDataRxmtCount
INTEGER,
x25OperRejectCount
INTEGER,
x25OperRegistrationRequestCount
INTEGER,
x25OperNumberPVCs
INTEGER,
x25OperDefCallParamId
OBJECT IDENTIFIER,
x25OperLocalAddress
X121Address,
x25OperDataLinkId
OBJECT IDENTIFIER,
x25OperProtocolVersionSupported
OBJECT IDENTIFIER
}
x25OperIndex OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex value for the X.25 interface."
::= { x25OperEntry 1 }
x25OperInterfaceMode OBJECT-TYPE
SYNTAX INTEGER {
dte (1),
dce (2),
dxe (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies DCE/DTE mode in which the
interface operates. A value of dxe
indicates the role will be determined by XID
negotiation at the Link Layer and that
negotiation has not yet taken place."
REFERENCE "10733 5.9 interfaceMode"
::= { x25OperEntry 2 }
x25OperMaxActiveCircuits OBJECT-TYPE
SYNTAX INTEGER (0..4096)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum number of circuits this PLE can
support."
REFERENCE "10733 5.9 maxActiveCircuits
See ISO 8208, Section 3.7"
::= { x25OperEntry 3 }
x25OperPacketSequencing OBJECT-TYPE
SYNTAX INTEGER {
modulo8 (1),
modulo128 (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The modulus of the packet sequence number
space."
REFERENCE "10733 extendedPacketSequencing;
See ISO 8208 Section 7.1.1"
::= { x25OperEntry 4 }
x25OperRestartTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T20 restart timer in milliseconds."
REFERENCE "10733 5.9 restartTime;
See ISO 8208 Section 4.1, table 26"
::= { x25OperEntry 5 }
x25OperCallTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T21 Call timer in milliseconds."
REFERENCE "10733 callTime;
See ISO 8208 Section 5.2.1, table 26"
::= { x25OperEntry 6 }
x25OperResetTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T22 Reset timer in milliseconds."
REFERENCE "10733 resetTime;
See ISO 8208 Section 8.1, table 26"
::= { x25OperEntry 7 }
x25OperClearTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T23 Clear timer in milliseconds."
REFERENCE "10733 clearTime;
See ISO 8208 Section 5.5.1, table 26"
::= { x25OperEntry 8 }
x25OperWindowTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T24 window status transmission timer
milliseconds. A value of 2147483647
indicates no window timer in use."
REFERENCE "10733 5.10.1 windowTime (opt);
See ISO 8208 Section 11.2.2, table 26"
::= { x25OperEntry 9 }
x25OperDataRxmtTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T25 Data Retransmission timer in
milliseconds. A value of 2147483647
indicates no data retransmission timer in
use."
REFERENCE "10733 5.10.1 dataRetransmissionTime (opt);
See ISO 8208 Section 11.2.1, table 26"
::= { x25OperEntry 10 }
x25OperInterruptTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T26 Interrupt timer in milliseconds. A
value of 2147483647 indicates interrupts are
not being used."
REFERENCE "10733 interruptTime;
See ISO 8208 Section 6.8.1, table 26"
::= { x25OperEntry 11 }
x25OperRejectTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T27 Reject retransmission timer in
milliseconds. A value of 2147483647
indicates no reject timer in use."
REFERENCE "10733 5.10.1 dataRejectTime (opt);
See ISO 8208 Section 13.4.1, table 26"
::= { x25OperEntry 12 }
x25OperRegistrationRequestTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The T28 registration timer in milliseconds.
A value of 2147483647 indicates no
registration timer in use."
REFERENCE "10733 5.8.1 registrationRequestTime (opt);
See ISO 8208 Section 13.1.1.1, table 26"
::= { x25OperEntry 13 }
x25OperMinimumRecallTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Minimum time interval between unsuccessful
call attempts in milliseconds."
REFERENCE "10733 5.9 minimum RecallTimer"
::= { x25OperEntry 14 }
x25OperRestartCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The R20 restart retransmission count."
REFERENCE "10733 5.9 restartCount
See ISO 8208 Section 4.1, table 27"
::= { x25OperEntry 15 }
x25OperResetCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The r22 Reset retransmission count."
REFERENCE "10733 resetCount;
See section ISO 8208 8.1, table 27"
::= { x25OperEntry 16 }
x25OperClearCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The r23 Clear retransmission count."
REFERENCE "10733 clearCount;
See ISO 8208 Section 5.5.1, table 27"
::= { x25OperEntry 17 }
x25OperDataRxmtCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The R25 Data retransmission count. This
value is undefined if the
x25OperDataRxmtTimer indicates no timer in
use."
REFERENCE "10733 5.10.1 dataRetransmissionCount (opt);
See ISO 8208 Section 11.2.1, table 27"
::= { x25OperEntry 18 }
x25OperRejectCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The R27 reject retransmission count. This
value is undefined if the x25OperRejectTimer
indicates no timer in use."
REFERENCE "10733 5.10.1 dataRejectCount (opt)"
::= { x25OperEntry 19 }
x25OperRegistrationRequestCount OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The R28 Registration retransmission Count.
This value is undefined if the
x25OperREgistrationRequestTimer indicates no
timer in use."
REFERENCE "10733 5.8.1 registrationRequestCount (opt);
See ISO 8208 Section 13.1.1.1, table 27"
::= { x25OperEntry 20 }
x25OperNumberPVCs OBJECT-TYPE
SYNTAX INTEGER (0..4096)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PVC configured for this PLE.
The PVCs use channel numbers from 1 to this
number."
::= { x25OperEntry 21 }
x25OperDefCallParamId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies the instance of the
x25CallParmIndex for the entry in the
x25CallParmTable that contains the default
call parameters for this PLE."
::= { x25OperEntry 22 }
x25OperLocalAddress OBJECT-TYPE
SYNTAX X121Address
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The local address for this PLE subnetwork.
A zero length address maybe returned by PLEs
that only support PVCs."
REFERENCE "10733 5.9 localDTEAddress"
::= { x25OperEntry 23 }
x25OperDataLinkId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This identifies the instance of the index
object in the first table of the most device
specific MIB for the interface used by this
PLE."
::= { x25OperEntry 24 }
x25OperProtocolVersionSupported OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identifies the version of the X.25 protocol
this interface supports. Object identifiers
for common versions are defined below in the
x25ProtocolVersion subtree."
REFERENCE "10733 5.9 protocolVersionSupported"
::= { x25OperEntry 25 }
x25StatTable OBJECT-TYPE
SYNTAX SEQUENCE OF X25StatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Statistics information about this X.25
PLE."
::= { x25ext 4 }
x25StatEntry OBJECT-TYPE
SYNTAX X25StatEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries of the x25StatTable."
INDEX { x25StatIndex }
::= { x25StatTable 1 }
X25StatEntry ::= SEQUENCE {
x25StatIndex
IfIndexType,
x25StatInCalls
Counter,
x25StatInCallRefusals
Counter,
x25StatInProviderInitiatedClears
Counter,
x25StatInRemotelyInitiatedResets
Counter,
x25StatInProviderInitiatedResets
Counter,
x25StatInRestarts
Counter,
x25StatInDataPackets
Counter,
x25StatInAccusedOfProtocolErrors
Counter,
x25StatInInterrupts
Counter,
x25StatOutCallAttempts
Counter,
x25StatOutCallFailures
Counter,
x25StatOutInterrupts
Counter,
x25StatOutDataPackets
Counter,
x25StatOutgoingCircuits
Gauge,
x25StatIncomingCircuits
Gauge,
x25StatTwowayCircuits
Gauge,
x25StatRestartTimeouts
Counter,
x25StatCallTimeouts
Counter,
x25StatResetTimeouts
Counter,
x25StatClearTimeouts
Counter,
x25StatDataRxmtTimeouts
Counter,
x25StatInterruptTimeouts
Counter,
x25StatRetryCountExceededs
Counter,
x25StatClearCountExceededs
Counter
}
x25StatIndex OBJECT-TYPE
SYNTAX IfIndexType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex value for the X.25 interface."
::= { x25StatEntry 1 }
x25StatInCalls OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of incoming calls received."
::= { x25StatEntry 2 }
x25StatInCallRefusals OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of incoming calls refused. This
includes calls refused by the PLE and by
higher layers. This also includes calls
cleared because of restricted fast select."
::= { x25StatEntry 3 }
x25StatInProviderInitiatedClears OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of clear requests with a cause
code other than DTE initiated."
REFERENCE "10733 providerInitiatedDisconnect"
::= { x25StatEntry 4 }
x25StatInRemotelyInitiatedResets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of reset requests received with
cause code DTE initiated."
REFERENCE "10733 remotelyInitiatedResets"
::= { x25StatEntry 5 }
x25StatInProviderInitiatedResets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of reset requests received with
cause code other than DTE initiated."
REFERENCE "10733 ProviderInitiatedResets"
::= { x25StatEntry 6 }
x25StatInRestarts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of remotely initiated (including
provider initiated) restarts experienced by
the PLE excluding the restart associated
with bringing up the PLE interface. This
only counts restarts received when the PLE
already has an established connection with
the remove PLE."
REFERENCE "10733 5.9 remotelyInitiatedRestarts"
::= { x25StatEntry 7 }
x25StatInDataPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets received."
REFERENCE "10733 5.9 dataPacketsReceived."
::= { x25StatEntry 8 }
x25StatInAccusedOfProtocolErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of packets received containing a
procedure error cause code. These include
clear, reset, restart, or diagnostic
packets."
REFERENCE "CD 10733 5.9 accusedOfProtocolError"
::= { x25StatEntry 9 }
x25StatInInterrupts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of interrupt packets received by
the PLE or over the PVC/VC."
REFERENCE "10733 interruptPacketsReceived"
::= { x25StatEntry 10 }
x25StatOutCallAttempts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of calls attempted."
REFERENCE "10733 5.9 callAttempts"
::= { x25StatEntry 11 }
x25StatOutCallFailures OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of call attempts which failed.
This includes calls that were cleared
because of restrictive fast select."
::= { x25StatEntry 12 }
x25StatOutInterrupts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of interrupt packets send by the
PLE or over the PVC/VC."
REFERENCE "10733 InterruptPacketsSent"
::= { x25StatEntry 13 }
x25StatOutDataPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of data packets sent by this
PLE."
REFERENCE "10733 dataPacketSent"
::= { x25StatEntry 14 }
x25StatOutgoingCircuits OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active outgoing circuits.
This includes call requests sent but not yet
confirmed. This does not count PVCs."
::= { x25StatEntry 15 }
x25StatIncomingCircuits OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active Incoming Circuits.
This includes call indications received but
not yet acknowledged. This does not count
PVCs."
::= { x25StatEntry 16 }
x25StatTwowayCircuits OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of active two-way Circuits.
This includes call requests sent but not yet
confirmed. This does not count PVCs."
::= { x25StatEntry 17 }
x25StatRestartTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T20 restart timer
expired."
REFERENCE "10733 5.9 restartTimeouts"
::= { x25StatEntry 18 }
x25StatCallTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T21 call timer
expired."
REFERENCE "10733 5.9 callTimeouts"
::= { x25StatEntry 19 }
x25StatResetTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T22 reset timer
expired."
REFERENCE "10733 5.9 resetTimeouts"
::= { x25StatEntry 20 }
x25StatClearTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T23 clear timer
expired."
REFERENCE "10733 5.9 clearTimeouts"
::= { x25StatEntry 21 }
x25StatDataRxmtTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T25 data timer
expired."
REFERENCE "10733 5.9 dataRetransmissionsTimerExpiries"
::= { x25StatEntry 22 }
x25StatInterruptTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T26 interrupt timer
expired."
REFERENCE "10733 5.9 interruptTimerExpires"
::= { x25StatEntry 23 }
x25StatRetryCountExceededs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times a retry counter was
exhausted."
REFERENCE "10733 5.9 retryCountsExceeded"
::= { x25StatEntry 24 }
x25StatClearCountExceededs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the R23 clear count was
exceeded."
REFERENCE "10733 5.9 clearCountsExceeded"
::= { x25StatEntry 25 }
x25ChannelTable OBJECT-TYPE
SYNTAX SEQUENCE OF X25ChannelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"These objects contain information about the
channel number configuration in an X.25 PLE.
These values are the configured values.
changes in these values after the interfaces
has started may not be reflected in the
operating PLE."
REFERENCE "See ISO 8208, Section 3.7"
::= { x25ext 5 }
x25ChannelEntry OBJECT-TYPE
SYNTAX X25ChannelEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries of x25ChannelTable."
REFERENCE "This provides the information available
in 10733 logicalChannelAssignments."
INDEX { x25ChannelIndex }
::= { x25ChannelTable 1 }
X25ChannelEntry ::= SEQUENCE {
x25ChannelIndex
IfIndexType,
x25ChannelLIC
INTEGER,
x25ChannelHIC
INTEGER,
x25ChannelLTC
INTEGER,
x25ChannelHTC
INTEGER,
x25ChannelLOC
INTEGER,
x25ChannelHOC
INTEGER
}
x25ChannelIndex OBJECT-TYPE
SYNTAX IfIndexType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex value for the X.25 Interface."
::= { x25ChannelEntry 1 }
x25ChannelLIC OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lowest Incoming channel."
::= { x25ChannelEntry 2 }
x25ChannelHIC OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Highest Incoming channel. A value of zero
indicates no channels in this range."
::= { x25ChannelEntry 3 }
x25ChannelLTC OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lowest Two-way channel."
::= { x25ChannelEntry 4 }
x25ChannelHTC OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Highest Two-way channel. A value of zero
indicates no channels in this range."
::= { x25ChannelEntry 5 }
x25ChannelLOC OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lowest outgoing channel."
::= { x25ChannelEntry 6 }
x25ChannelHOC OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Highest outgoing channel. A value of zero
indicates no channels in this range."
::= { x25ChannelEntry 7 }
x25CircuitTable OBJECT-TYPE
SYNTAX SEQUENCE OF X25CircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"These objects contain general information
about a specific circuit of an X.25 PLE."
::= { x25ext 6 }
x25CircuitEntry OBJECT-TYPE
SYNTAX X25CircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries of x25CircuitTable."
INDEX { x25CircuitIndex,
x25CircuitChannel }
::= { x25CircuitTable 1 }
X25CircuitEntry ::= SEQUENCE {
x25CircuitIndex
IfIndexType,
x25CircuitChannel
INTEGER,
x25CircuitStatus
INTEGER,
x25CircuitEstablishTime
TimeTicks,
x25CircuitDirection
INTEGER,
x25CircuitInOctets
Counter,
x25CircuitInPdus
Counter,
x25CircuitInRemotelyInitiatedResets
Counter,
x25CircuitInProviderInitiatedResets
Counter,
x25CircuitInInterrupts
Counter,
x25CircuitOutOctets
Counter,
x25CircuitOutPdus
Counter,
x25CircuitOutInterrupts
Counter,
x25CircuitDataRetransmissionTimeouts
Counter,
x25CircuitResetTimeouts
Counter,
x25CircuitInterruptTimeouts
Counter,
x25CircuitCallParamId
OBJECT IDENTIFIER,
x25CircuitCalledDteAddress
X121Address,
x25CircuitCallingDteAddress
X121Address,
x25CircuitOriginallyCalledAddress
X121Address,
x25CircuitDescr
DisplayString
}
x25CircuitIndex OBJECT-TYPE
SYNTAX IfIndexType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The ifIndex value for the X.25 Interface."
::= { x25CircuitEntry 1 }
x25CircuitChannel OBJECT-TYPE
SYNTAX INTEGER (0..4095)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The channel number for this circuit."
::= { x25CircuitEntry 2 }
x25CircuitStatus OBJECT-TYPE
SYNTAX INTEGER { invalid (1),
closed (2), calling (3), open (4), clearing (5), pvc (6),
pvcResetting (7),
startClear (8), startPvcResetting (9), other (10)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This object reports the current status of
the circuit.
An existing instance of this object can only
be set to startClear, startPvcResetting, or
invalid. An instance with the value calling
or open can only be set to startClear and
that action will start clearing the circuit.
An instance with the value PVC can only be
set to startPvcResetting or invalid and that
action resets the PVC or deletes the circuit
respectively. The values startClear or
startPvcResetting will never be returned by
an agent. An attempt to set the status of
an existing instance to a value other than
one of these values will result in an error.
A non-existing instance can be set to PVC to
create a PVC if the implementation supports
dynamic creation of PVCs. Some
implementations may only allow creation and
deletion of PVCs if the interface is down.
Since the instance identifier will supply
the PLE index and the channel number,
setting this object alone supplies
sufficient information to create the
instance. All the DEFVAL clauses for the
other objects of this table are appropriate
for creating a PVC; PLEs creating entries
for placed or accepted calls will use values
appropriate for the call rather than the
value of the DEFVAL clause. Two managers
trying to create the same PVC can determine
from the return code which manager succeeded
and which failed (the failing manager fails
because it can not set a value of PVC for an
existing object).
An entry in the closed or invalid state may
be deleted or reused at the agent's
convence. If the entry is kept in the
closed state, the values of the parameters
associated with the entry must be correct.
Closed implies the values in the circuit
table are correct.
The value of invalid indicates the other
values in the table are invalid. Many
agents may never return a value of invalid
because they dynamically allocate and free
unused table entries. An agent for a
statically configured systems can return
invalid to indicate the entry has not yet
been used so the counters contain no
information."
REFERENCE "See ISO 8208,
table 33 for (p<n>) state table"
::= { x25CircuitEntry 3 }
x25CircuitEstablishTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when the channel was
associated with this circuit. For outgoing
SVCs, this is the time the first call packet
was sent. For incoming SVCs, this is the
time the call indication was received. For
PVCs this is the time the PVC was able to
pass data to a higher layer entity without
loss of data."
::= { x25CircuitEntry 4 }
x25CircuitDirection OBJECT-TYPE
SYNTAX INTEGER {
incoming (1),
outgoing (2),
pvc (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The direction of the call that established
this circuit."
REFERENCE "10733 direction"
DEFVAL { pvc }
::= { x25CircuitEntry 5 }
x25CircuitInOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets of user data delivered
to upper layer."
REFERENCE "5.11 octetsReceivedCounter"
::= { x25CircuitEntry 6 }
x25CircuitInPdus OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PDUs received for this
circuit."
REFERENCE "10733 5.11 dataPacketsReceived"
::= { x25CircuitEntry 7 }
x25CircuitInRemotelyInitiatedResets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Resets received for this
circuit with cause code of DTE initiated."
REFERENCE "10733 remotelyInitiatedResets"
::= { x25CircuitEntry 8 }
x25CircuitInProviderInitiatedResets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Resets received for this
circuit with cause code other than DTE
initiated."
REFERENCE "10733 ProviderInitiatedResets"
::= { x25CircuitEntry 9 }
x25CircuitInInterrupts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of interrupt packets received
for this circuit."
REFERENCE "10733 interruptPacketsReceived"
::= { x25CircuitEntry 10 }
x25CircuitOutOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets of user data sent for
this circuit."
REFERENCE "10733 5.11 octetsSentCounter"
::= { x25CircuitEntry 11 }
x25CircuitOutPdus OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of PDUs sent for this circuit."
REFERENCE "10733 5.11 dataPacketsSent"
::= { x25CircuitEntry 12 }
x25CircuitOutInterrupts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of interrupt packets sent on
this circuit."
REFERENCE "10733 interruptPacketsSent"
::= { x25CircuitEntry 13 }
x25CircuitDataRetransmissionTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T25 data
retransmission timer expired for this
circuit."
REFERENCE "10733 5.11 dataRetransmissionTimerExpiries"
::= { x25CircuitEntry 14 }
x25CircuitResetTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T22 reset timer
expired for this circuit."
REFERENCE "10733 5.11 resetTimeouts"
::= { x25CircuitEntry 15 }
x25CircuitInterruptTimeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the T26 Interrupt timer
expired for this circuit."
REFERENCE "10733 interruptTimerExpiries"
::= { x25CircuitEntry 16 }
x25CircuitCallParamId OBJECT-TYPE
SYNTAX OBJECT IDENTIFIER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This identifies the instance of the
x25CallParmIndex for the entry in the
x25CallParmTable which contains the call
parameters in use with this circuit. The
entry referenced must contain the values
that are currently in use by the circuit
rather than proposed values. A value of
NULL indicates the circuit is a PVC or is
using all the default parameters."
::= { x25CircuitEntry 17 }
x25CircuitCalledDteAddress OBJECT-TYPE
SYNTAX X121Address
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For incoming calls, this is the called
address from the call indication packet.
For outgoing calls, this is the called
address from the call confirmation packet.
This will be zero length for PVCs."
REFERENCE "10733 calledDTEAddress"
DEFVAL { ''h }
::= { x25CircuitEntry 18 }
x25CircuitCallingDteAddress OBJECT-TYPE
SYNTAX X121Address
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For incoming calls, this is the calling
address from the call indication packet.
For outgoing calls, this is the calling
address from the call confirmation packet.
This will be zero length for PVCs."
REFERENCE "10733 callingDTEAddress"
DEFVAL { ''h }
::= { x25CircuitEntry 19 }
x25CircuitOriginallyCalledAddress OBJECT-TYPE
SYNTAX X121Address
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For incoming calls, this is the address in
the call Redirection or Call Deflection
Notification facility if the call was
deflected or redirected, otherwise it will
be called address from the call indication
packet. For outgoing calls, this is the
address from the call request packet. This
will be zero length for PVCs."
REFERENCE "10733 originallyCalledAddress"
DEFVAL { ''h }
::= { x25CircuitEntry 20 }
x25CircuitDescr OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A descriptive string associated with this
circuit. This provides a place for the
agent to supply any descriptive information
it knows about the use or owner of the
circuit. The agent may return the process
identifier and user name for the process
using the circuit. Alternative the agent
may return the name of the configuration
entry that caused a bridge to establish the
circuit. A zero length value indicates the
agent doesn't have any additional
information."
DEFVAL { ''h }
::= { x25CircuitEntry 21 }
x25CallParmTable OBJECT-TYPE
SYNTAX SEQUENCE OF X25CallParmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"These objects contain the parameters that
can be varied between X.25 calls. The
entries in this table are independent of the
PLE. There exists only one of these tables
for the entire system. The indexes for the
entries are independent of any PLE or any
circuit. Other tables reference entries in
this table. Entries in this table can be
used for default PLE parameters, for
parameters to use to place/answer a call,
for the parameters currently in use for a
circuit, or parameters that were used by a
circuit.
The number of references to a given set of
parameters can be found in the
x25CallParmRefCount object sharing the same
instance identifier with the parameters.
The value of this reference count also
affects the access of the objects in this
table. An object in this table with the
same instance identifier as the instance
identifier of an x25CallParmRefCount must be
consider associated with that reference
count. An object with an associated
reference count of zero can be written (if
its ACCESS clause allows it). An object
with an associated reference count greater
than zero can not be written (regardless of
the ACCESS clause). This ensures that a set
of call parameters being referenced from
another table can not be modified or changed
in a ways inappropriate for continued use by
that table."
::= { x25ext 7 }
x25CallParmEntry OBJECT-TYPE
SYNTAX X25CallParmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entries of x25CallParmTable."
INDEX { x25CallParmIndex }
::= { x25CallParmTable 1 }
X25CallParmEntry ::= SEQUENCE {
x25CallParmIndex
PositiveInteger,
x25CallParmStatus
EntryStatus,
x25CallParmRefCount
PositiveInteger,
x25CallParmInPacketSize
INTEGER,
x25CallParmOutPacketSize
INTEGER,
x25CallParmInWindowSize
INTEGER,
x25CallParmOutWindowSize
INTEGER,
x25CallParmAcceptReverseCharging
INTEGER,
x25CallParmProposeReverseCharging
INTEGER,
x25CallParmFastSelect
INTEGER,
x25CallParmInThruPutClasSize
INTEGER,
x25CallParmOutThruPutClasSize
INTEGER,
x25CallParmCug
DisplayString,
x25CallParmCugoa
DisplayString,
x25CallParmBcug
DisplayString,
x25CallParmNui
OCTET STRING,
x25CallParmChargingInfo
INTEGER,
x25CallParmRpoa
DisplayString,
x25CallParmTrnstDly
INTEGER,
x25CallParmCallingExt
DisplayString,
x25CallParmCalledExt
DisplayString,
x25CallParmInMinThuPutCls
INTEGER,
x25CallParmOutMinThuPutCls
INTEGER,
x25CallParmEndTrnsDly
OCTET STRING,
x25CallParmPriority
OCTET STRING,
x25CallParmProtection
DisplayString,
x25CallParmExptData
INTEGER,
x25CallParmUserData
OCTET STRING,
x25CallParmCallingNetworkFacilities
OCTET STRING,
x25CallParmCalledNetworkFacilities
OCTET STRING
}
x25CallParmIndex OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A value that distinguishes this entry from
another entry. Entries in this table are
referenced from other objects which identify
call parameters.
It is impossible to know which other objects
in the MIB reference entries in the table by
looking at this table. Because of this,
changes to parameters must be accomplished
by creating a new entry in this table and
then changing the referencing table to
identify the new entry.
Note that an agent will only use the values
in this table when another table is changed
to reference those values. The number of
other tables that reference an index object
in this table can be found in
x25CallParmRefCount. The value of the
reference count will affect the writability
of the objects as explained above.
Entries in this table which have a reference
count of zero maybe deleted at the convence
of the agent. Care should be taken by the
agent to give the NMS sufficient time to
create a reference to newly created entries.
Should a Management Station not find a free
index with which to create a new entry, it
may feel free to delete entries with a
reference count of zero. However in doing
so the Management Station much realize it
may impact other Management Stations."
::= { x25CallParmEntry 1 }
x25CallParmStatus OBJECT-TYPE
SYNTAX EntryStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The status of this call parameter entry.
See RFC 1271 for details of usage."
::= { x25CallParmEntry 2 }
x25CallParmRefCount OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of references know by a
management station to exist to this set of
call parameters. This is the number of
other objects that have returned a value of,
and will return a value of, the index for
this set of call parameters. Examples of
such objects are the x25AdmnDefCallParamId,
x25OperDataLinkId, or x25AdmnDefCallParamId
objects defined above."
::= { x25CallParmEntry 3 }
x25CallParmInPacketSize OBJECT-TYPE
SYNTAX INTEGER (0..4096)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum receive packet size in octets
for a circuit. A size of zero for a circuit
means use the PLE default size. A size of
zero for the PLE means use a default size of
128."
REFERENCE "10733 proposedPacketSize;
See ISO 8208 Section 15.2.2.1.1"
DEFVAL { 128 }
::= { x25CallParmEntry 4 }
x25CallParmOutPacketSize OBJECT-TYPE
SYNTAX INTEGER (0..4096)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum transmit packet size in octets
for a circuit. A size of zero for a circuit
means use the PLE default size. A size of
zero for the PLE default means use a default
size of 128."
REFERENCE "10733 proposedPacketSize;
See ISO 8208 Section 15.2.2.1.1"
DEFVAL { 128 }
::= { x25CallParmEntry 5 }
x25CallParmInWindowSize OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The receive window size for a circuit. A
size of zero for a circuit means use the PLE
default size. A size of zero for the PLE
default means use 2."
REFERENCE "10733 proposedWindowSize;
See ISO 8208 Section 15.2.2.1.2"
DEFVAL { 2 }
::= { x25CallParmEntry 6 }
x25CallParmOutWindowSize OBJECT-TYPE
SYNTAX INTEGER (0..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The transmit window size for a circuit. A
size of zero for a circuit means use the PLE
default size. A size of zero for the PLE
default means use 2."
REFERENCE "10733 proposedWindowSize;
See ISO 8208 Section 15.2.2.1.2"
DEFVAL { 2 }
::= { x25CallParmEntry 7 }
x25CallParmAcceptReverseCharging OBJECT-TYPE
SYNTAX INTEGER {
default (1),
accept (2),
refuse (3),
neverAccept (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An enumeration defining if the PLE will
accept or refuse charges. A value of
default for a circuit means use the PLE
default value. A value of neverAccept is
only used for the PLE default and indicates
the PLE will never accept reverse charging.
A value of default for a PLE default means
refuse."
REFERENCE "10733 acceptReverseCharging"
DEFVAL { refuse }
::= { x25CallParmEntry 8 }
x25CallParmProposeReverseCharging OBJECT-TYPE
SYNTAX INTEGER {
default (1),
reverse (2),
local (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"An enumeration defining if the PLE should
propose reverse or local charging. The
value of default for a circuit means use the
PLE default. The value of default for the
PLE default means use local."
REFERENCE "10733 proposedPacketSize;
See ISO 8208 Section 15.2.2.6"
DEFVAL { local }
::= { x25CallParmEntry 9 }
x25CallParmFastSelect OBJECT-TYPE
SYNTAX INTEGER {
default (1),
notSpecified (2),
fastSelect (3),
restrictedFastResponse (4),
noFastSelect (5),
noRestrictedFastResponse (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Expresses preference for use of fast select
facility. The value of default for a
circuit is the PLE default. A value of
default for the PLE means noFastSelect. A
value of noFastSelect or
noRestrictedFastResponse indicates a circuit
may not use fast select or restricted fast
response."
REFERENCE "10733 fastSelect;
Sec ISO 8208 Section 15.2.2.6"
DEFVAL { noFastSelect }
::= { x25CallParmEntry 10 }
x25CallParmInThruPutClasSize OBJECT-TYPE
SYNTAX INTEGER {
tcReserved1 (1),
tcReserved2 (2),
tc75 (3),
tc150 (4),
tc300 (5),
tc600 (6),
tc1200 (7),
tc2400 (8),
tc4800 (9),
tc9600 (10),
tc19200 (11),
tc48000 (12),
tc64000 (13),
tcReserved14 (14),
tcReserved15 (15),
tcReserved0 (16),
tcNone (17),
tcDefault (18)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The incoming throughput class to negotiate.
A value of tcDefault for a circuit means use
the PLE default. A value of tcDefault for
the PLE default means tcNone. A value of
tcNone means do not negotiate throughtput
class."
REFERENCE "See ISO 8208 Section 15.2.2.2, table 18"
DEFVAL { tcNone }
::= { x25CallParmEntry 11 }
x25CallParmOutThruPutClasSize OBJECT-TYPE
SYNTAX INTEGER {
tcReserved1 (1),
tcReserved2 (2),
tc75 (3),
tc150 (4),
tc300 (5),
tc600 (6),
tc1200 (7),
tc2400 (8),
tc4800 (9),
tc9600 (10),
tc19200 (11),
tc48000 (12),
tc64000 (13),
tcReserved14 (14),
tcReserved15 (15),
tcReserved0 (16),
tcNone (17),
tcDefault (18)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The outgoing throughput class to negotiate.
A value of tcDefault for a circuit means use
the PLE default. A value of tcDefault for
the PLE default means use tcNone. A value
of tcNone means do not negotiate throughtput
class."
REFERENCE "See ISO 8208 Section 15.2.2.2, table 18"
DEFVAL { tcNone }
::= { x25CallParmEntry 12 }
x25CallParmCug OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Closed User Group to specify. This
consists of two or four octets containing
the characters 0 through 9. A zero length
string indicates no facility requested. A
string length of three containing the
characters DEF for a circuit means use the
PLE default, (the PLE default parameter may
not reference an entry of DEF.)"
REFERENCE "See ISO 8208 Section 15.2.2.3"
DEFVAL { ''h }
::= { x25CallParmEntry 13 }
x25CallParmCugoa OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..4))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Closed User Group with Outgoing Access
to specify. This consists of two or four
octets containing the characters 0 through
9. A string length of three containing the
characters DEF for a circuit means use the
PLE default (the PLE default parameters may
not reference an entry of DEF). A zero
length string indicates no facility
requested."
REFERENCE "See ISO 8208 Section 15.2.2.4"
DEFVAL { ''h }
::= { x25CallParmEntry 14 }
x25CallParmBcug OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..3))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Bilateral Closed User Group to specify.
This consists of two octets containing the
characters 0 through 9. A string length of
three containing the characters DEF for a
circuit means use the PLE default (the PLE
default parameter may not reference an entry
of DEF). A zero length string indicates no
facility requested."
REFERENCE "See ISO 8208 Section 15.2.2.5"
DEFVAL { ''h }
::= { x25CallParmEntry 15 }
x25CallParmNui OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..108))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Network User Identifier facility. This
is binary value to be included immediately
after the length field. The PLE will supply
the length octet. A zero length string
indicates no facility requested. This value
is ignored for the PLE default parameters
entry."
REFERENCE "See ISO 8208 Section 15.2.2.7"
DEFVAL { ''h }
::= { x25CallParmEntry 16 }
x25CallParmChargingInfo OBJECT-TYPE
SYNTAX INTEGER {
default (1),
noFacility (2),
noChargingInfo (3),
chargingInfo (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The charging Information facility. A value
of default for a circuit means use the PLE
default. The value of default for the
default PLE parameters means use noFacility.
The value of noFacility means do not include
a facility."
REFERENCE "See ISO 8208 Section 15.2.2.8"
DEFVAL { noFacility }
::= { x25CallParmEntry 17 }
x25CallParmRpoa OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..108))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The RPOA facility. The octet string
contains n * 4 sequences of the characters
0-9 to specify a facility with n entries.
The octet string containing the 3 characters
DEF for a circuit specifies use of the PLE
default (the entry for the PLE default may
not contain DEF). A zero length string
indicates no facility requested."
REFERENCE "See ISO 8208, section 15.2.2.9"
DEFVAL { ''h }
::= { x25CallParmEntry 18 }
x25CallParmTrnstDly OBJECT-TYPE
SYNTAX INTEGER (0..65537)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Transit Delay Selection and Indication
value. A value of 65536 indicates no
facility requested. A value of 65537 for a
circuit means use the PLE default (the PLE
default parameters entry may not use the
value 65537). The value 65535 may only be
used to indicate the value in use by a
circuit."
REFERENCE "See ISO 8208, Section 15.2.2.13"
DEFVAL { 65536 }
::= { x25CallParmEntry 19 }
x25CallParmCallingExt OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Calling Extension facility. This
contains one of the following:
A sequence of hex digits with the value to
be put in the facility. These digits will be
converted to binary by the agent and put in
the facility. These octets do not include
the length octet.
A value containing the three character DEF
for a circuit means use the PLE default,
(the entry for the PLE default parameters
may not use the value DEF).
A zero length string indicates no facility
requested."
REFERENCE "See ISO 8208 Section 15.3.2.1"
DEFVAL { ''h }
::= { x25CallParmEntry 20 }
x25CallParmCalledExt OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..40))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Called Extension facility. This
contains one of the following:
A sequence of hex digits with the value to
be put in the facility. These digits will be
converted to binary by the agent and put in
the facility. These octets do not include
the length octet.
A value containing the three character DEF
for a circuit means use the PLE default,
(the entry for the PLE default parameters
may not use the value DEF).
A zero length string indicates no facility
requested."
REFERENCE "See ISO 8208 Section 15.3.2.2"
DEFVAL { ''h }
::= { x25CallParmEntry 21 }
x25CallParmInMinThuPutCls OBJECT-TYPE
SYNTAX INTEGER (0..17)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The minimum input throughput Class. A
value of 16 for a circuit means use the PLE
default (the PLE parameters entry may not
use this value). A value of 17 indicates no
facility requested."
REFERENCE "See ISO 8208 Section 15.3.2.3"
DEFVAL { 17 }
::= { x25CallParmEntry 22 }
x25CallParmOutMinThuPutCls OBJECT-TYPE
SYNTAX INTEGER (0..17)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The minimum output throughput Class. A
value of 16 for a circuit means use the PLE
default (the PLE parameters entry may not
use this value). A value of 17 indicates no
facility requested."
REFERENCE "See ISO 8208 Section 15.3.2.3"
DEFVAL { 17 }
::= { x25CallParmEntry 23 }
x25CallParmEndTrnsDly OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..6))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The End-to-End Transit Delay to negotiate.
An octet string of length 2, 4, or 6
contains the facility encoded as specified
in ISO/IEC 8208 section 15.3.2.4. An octet
string of length 3 containing the three
character DEF for a circuit means use the
PLE default (the entry for the PLE default
can not contain the characters DEF). A zero
length string indicates no facility
requested."
REFERENCE "See ISO 8208 Section 15.3.2.4"
DEFVAL { ''h }
::= { x25CallParmEntry 24 }
x25CallParmPriority OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(0..6))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The priority facility to negotiate. The
octet string encoded as specified in ISO/IEC
8208 section 15.3.2.5. A zero length string
indicates no facility requested. The entry
for the PLE default parameters must be zero
length."
REFERENCE "See ISO 8208 Section 15.3.2.5"
DEFVAL { ''h }
::= { x25CallParmEntry 25 }
x25CallParmProtection OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..108))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string contains the following:
A hex string containing the value for the
protection facility. This will be converted
from hex to the octets actually in the
packet by the agent. The agent will supply
the length field and the length octet is not
contained in this string.
An string containing the 3 characters DEF
for a circuit means use the PLE default (the
entry for the PLE default parameters may not
use the value DEF).
A zero length string mean no facility
requested."
REFERENCE "See ISO 8208 Section 15.3.2.5"
DEFVAL { ''h }
::= { x25CallParmEntry 26 }
x25CallParmExptData OBJECT-TYPE
SYNTAX INTEGER {
default (1),
noExpeditedData (2),
expeditedData (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Expedited Data facility to negotiate.
A value of default for a circuit means use
the PLE default value. The entry for the
PLE default parameters may not have the
value default."
REFERENCE "See ISO 8208 Section 15.3.2.7"
DEFVAL { noExpeditedData }
::= { x25CallParmEntry 27 }
x25CallParmUserData OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..128))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The call user data as placed in the packet.
A zero length string indicates no call user
data. If both the circuit call parameters
and the PLE default have call user data
defined, the data from the circuit call
parameters will be used. If only the PLE
has data defined, the PLE entry will be
used. If neither the circuit call
parameters or the PLE default entry has a
value, no call user data will be sent."
REFERENCE "See ISO 8208 Section 12.2.1.1.6, 12.2.1.2"
DEFVAL { ''h }
::= { x25CallParmEntry 28 }
x25CallParmCallingNetworkFacilities OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..108))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The calling network facilities. The
facilities are encoded here exactly as
encoded in the call packet. These
facilities do not include the marker
facility code.
A zero length string in the entry for the
parameter to use when establishing a circuit
means use the PLE default. A zero length
string in the entry for PLE default
parameters indicates no default facilities."
REFERENCE "See ISO 8206 Section 15.1, category b"
DEFVAL { ''h }
::= { x25CallParmEntry 29 }
x25CallParmCalledNetworkFacilities OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0..108))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The called network facilities. The
facilities are encoded here exactly as
encoded in the call packet. These
facilities do not include the marker
facility code.
A zero length string in the entry for the
parameter to use when establishing a circuit
means use the PLE default. A zero length
string in the entry for PLE default
parameters indicates no default facilities."
REFERENCE "See ISO 8206 Section 15.1, category c"
DEFVAL { ''h }
::= { x25CallParmEntry 30 }
x25Restart TRAP-TYPE
ENTERPRISE eicon
VARIABLES { x25OperIndex }
DESCRIPTION
"This trap means the X.25 PLE sent or
received a restart packet. The restart that
brings up the link should not send a
x25Restart trap so the interface should send
a linkUp trap. Sending this trap means the
agent does not send a linkDown and linkUp
trap."
::= 451
x25Reset TRAP-TYPE
ENTERPRISE eicon
VARIABLES { x25CircuitIndex,
x25CircuitChannel }
DESCRIPTION
"If the PLE sends or receives a reset, the
agent should send an x25Reset trap."
::= 2
END