Nortel-Magellan-Passport-AtmIispMIB
DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
passportMIBs
FROM Nortel-Magellan-Passport-UsefulDefinitionsMIB
Counter32,
DisplayString,
StorageType,
RowStatus,
Gauge32,
Integer32,
Unsigned32
FROM Nortel-Magellan-Passport-StandardTextualConventionsMIB
Hex,
NonReplicated,
AsciiStringIndex
FROM Nortel-Magellan-Passport-TextualConventionsMIB
atmIfVptIndex,
atmIfVpt,
atmIfIndex,
atmIf
FROM Nortel-Magellan-Passport-AtmCoreMIB;
atmIispMIB OBJECT IDENTIFIER ::= { passportMIBs 70 }
atmIfIisp OBJECT IDENTIFIER ::= { atmIf 7 }
atmIfIispRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfIisp components."
::= { atmIfIisp 1 }
atmIfIispRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfIispRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfIisp component."
INDEX {
atmIfIndex,
atmIfIispIndex }
::= { atmIfIispRowStatusTable 1 }
AtmIfIispRowStatusEntry ::= SEQUENCE {
atmIfIispRowStatus
RowStatus,
atmIfIispComponentName
DisplayString,
atmIfIispStorageType
StorageType,
atmIfIispIndex
NonReplicated }
atmIfIispRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfIisp components.
These components can be added and deleted."
::= { atmIfIispRowStatusEntry 1 }
atmIfIispComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfIispRowStatusEntry 2 }
atmIfIispStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfIisp tables."
::= { atmIfIispRowStatusEntry 4 }
atmIfIispIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfIisp tables."
::= { atmIfIispRowStatusEntry 10 }
atmIfIispProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the provisionable attributes for the Iisp
component."
::= { atmIfIisp 10 }
atmIfIispProvEntry OBJECT-TYPE
SYNTAX AtmIfIispProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispProvTable."
INDEX {
atmIfIndex,
atmIfIispIndex }
::= { atmIfIispProvTable 1 }
AtmIfIispProvEntry ::= SEQUENCE {
atmIfIispVersion
INTEGER,
atmIfIispSide
INTEGER,
atmIfIispSoftPvcRetryPeriod
Unsigned32,
atmIfIispSoftPvpAndPvcRetryPeriod
Unsigned32,
atmIfIispSoftPvpAndPvcHoldOffTime
Unsigned32 }
atmIfIispVersion OBJECT-TYPE
SYNTAX INTEGER {
iisp10Sig30(2),
iisp10Sig31(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute indicates which specification the IISP interface
complies with. The options are iisp10Sig30 which refers to IISP
version 1.0 with 3.0 signalling and iisp10Sig31 which refers to IISP
version 1.0 with 3.1 signalling. If this attribute is changed, all
switched Vcc components in this interface are cleared due to the
fact that the two versions are incompatible."
DEFVAL { iisp10Sig31 }
::= { atmIfIispProvEntry 1 }
atmIfIispSide OBJECT-TYPE
SYNTAX INTEGER {
networkSide(0),
userSide(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute indicates which side the interface is, user or network."
DEFVAL { networkSide }
::= { atmIfIispProvEntry 2 }
atmIfIispSoftPvcRetryPeriod OBJECT-TYPE
SYNTAX Unsigned32 (20..999999)
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This attribute specifies the time to wait between call set up retries.
The resolution is to the nearest 10 seconds.
This attribute has been obsoleted and is replaced by the
softPvpAndPvcRetryPeriod attribute."
DEFVAL { 60 }
::= { atmIfIispProvEntry 3 }
atmIfIispSoftPvpAndPvcRetryPeriod OBJECT-TYPE
SYNTAX Unsigned32 (20..999999)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the time to wait between soft PVP or soft
PVC call setup retries. The resolution is to the nearest 10 seconds."
DEFVAL { 60 }
::= { atmIfIispProvEntry 4 }
atmIfIispSoftPvpAndPvcHoldOffTime OBJECT-TYPE
SYNTAX Unsigned32 (0 | 50..20000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies how long to hold off retries following a
release or the connection. The resolution is to the nearest 50 ms."
DEFVAL { 0 }
::= { atmIfIispProvEntry 5 }
atmIfIispAcctOptTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispAcctOptEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the provisionable attributes for accounting."
::= { atmIfIisp 11 }
atmIfIispAcctOptEntry OBJECT-TYPE
SYNTAX AtmIfIispAcctOptEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispAcctOptTable."
INDEX {
atmIfIndex,
atmIfIispIndex }
::= { atmIfIispAcctOptTable 1 }
AtmIfIispAcctOptEntry ::= SEQUENCE {
atmIfIispAccountCollection
OCTET STRING,
atmIfIispAccountConnectionType
INTEGER,
atmIfIispAccountClass
Unsigned32,
atmIfIispServiceExchange
Unsigned32 }
atmIfIispAccountCollection OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute is used to turn accounting on or off for SVC and
SPVC connections. It also specifies the reason(s) for which
accounting data is collected: billing, test, study, audit, or force.
If the set of reasons is not empty then accounting records will be
generated by this interface in the following situations:
- on a TODA changeover if TODA is enabled;
- every 12 hours (per connection) if TODA is disabled;
- on every call clear (a call record with final cell counts).
If none of the reasons is present, then accounting will be
suppressed.
The reason for collection is recorded in the accounting record, in
the attribute callingCollectReason or calledCollectReason as
appropriate.
Description of bits:
bill(0)
test(1)
study(2)
audit(3)
force(4)"
::= { atmIfIispAcctOptEntry 1 }
atmIfIispAccountConnectionType OBJECT-TYPE
SYNTAX INTEGER {
origTerm(0),
intermediate(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether accounting records generated by
this interface should be marked as originating, terminating or
intermediate. This attribute, in combination with the direction of the
call, determines the value of attribute connPointType of the
accounting record and may be used by downstream accounting
processes to correlate the records.
If the value is origTerm then records generated for incoming calls
will be marked as originating and records generated for outgoing
calls will be marked as terminating.
If the value is intermediate then records generated for all calls will
be marked as intermediate."
DEFVAL { intermediate }
::= { atmIfIispAcctOptEntry 2 }
atmIfIispAccountClass OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the accounting class associated with the
interface. Its meaning is determined by the network operator.
Its value is simply recorded in the accounting records generated by
this interface, in the attribute callingServiceType or
calledServiceType as appropriate."
DEFVAL { 0 }
::= { atmIfIispAcctOptEntry 3 }
atmIfIispServiceExchange OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the data service exchange associated with
this interface. Its meaning is determined by the network operator.
Its value is simply recorded in the accounting records generated by
this interface, in the attribute callingDse or calledDse as
appropriate."
DEFVAL { 0 }
::= { atmIfIispAcctOptEntry 4 }
atmIfIispSig OBJECT IDENTIFIER ::= { atmIfIisp 3 }
atmIfIispSigRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispSigRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfIispSig components."
::= { atmIfIispSig 1 }
atmIfIispSigRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfIispSigRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfIispSig component."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispSigIndex }
::= { atmIfIispSigRowStatusTable 1 }
AtmIfIispSigRowStatusEntry ::= SEQUENCE {
atmIfIispSigRowStatus
RowStatus,
atmIfIispSigComponentName
DisplayString,
atmIfIispSigStorageType
StorageType,
atmIfIispSigIndex
NonReplicated }
atmIfIispSigRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfIispSig components.
These components cannot be added nor deleted."
::= { atmIfIispSigRowStatusEntry 1 }
atmIfIispSigComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfIispSigRowStatusEntry 2 }
atmIfIispSigStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfIispSig tables."
::= { atmIfIispSigRowStatusEntry 4 }
atmIfIispSigIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfIispSig tables."
::= { atmIfIispSigRowStatusEntry 10 }
atmIfIispSigProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispSigProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute group contains the provisionable attributes for the
Signalling component."
::= { atmIfIispSig 10 }
atmIfIispSigProvEntry OBJECT-TYPE
SYNTAX AtmIfIispSigProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispSigProvTable."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispSigIndex }
::= { atmIfIispSigProvTable 1 }
AtmIfIispSigProvEntry ::= SEQUENCE {
atmIfIispSigVci
Unsigned32,
atmIfIispSigAddressConversion
INTEGER }
atmIfIispSigVci OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the signalling channel number."
DEFVAL { 5 }
::= { atmIfIispSigProvEntry 1 }
atmIfIispSigAddressConversion OBJECT-TYPE
SYNTAX INTEGER {
none(0),
nativeE164(1),
nsap(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the address conversion on the outgoing
signalling PDUs. The options are none, nativeE164, or nsap. The
none option is the default and if this option is chosen then nothing
is done to the address information element (IE) in the outgoing
signalling message. If nativeE164 option is chosen, then only
NSAP encapsulated E.164 addresses with zeros in the ESI are
converted to native E.164 format in the outgoing signalling
message. If the NSAP address is not encapsulated E.164 or the ESI
field is not zeros and the nativeE164 option is chosen, then the call
is cleared. If the nsap option is chosen, then native E.164 addresses
are converted to NSAP E.164 with zeros in the ESI field; otherwise
the address is in NSAP format and is not changed."
DEFVAL { none }
::= { atmIfIispSigProvEntry 2 }
atmIfIispSigStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispSigStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the three OSI State attributes. The descriptions
generically indicate what each state attribute implies about the
component. Note that not all the values and state combinations
described here are supported by every component which uses this
group. For component-specific information and the valid state
combinations, refer to NTP 241-7001-150, Passport Operations and
Maintenance Guide."
::= { atmIfIispSig 11 }
atmIfIispSigStateEntry OBJECT-TYPE
SYNTAX AtmIfIispSigStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispSigStateTable."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispSigIndex }
::= { atmIfIispSigStateTable 1 }
AtmIfIispSigStateEntry ::= SEQUENCE {
atmIfIispSigAdminState
INTEGER,
atmIfIispSigOperationalState
INTEGER,
atmIfIispSigUsageState
INTEGER }
atmIfIispSigAdminState OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
unlocked(1),
shuttingDown(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component."
DEFVAL { unlocked }
::= { atmIfIispSigStateEntry 1 }
atmIfIispSigOperationalState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle."
DEFVAL { disabled }
::= { atmIfIispSigStateEntry 2 }
atmIfIispSigUsageState OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
active(1),
busy(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time."
DEFVAL { idle }
::= { atmIfIispSigStateEntry 3 }
atmIfIispSigOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispSigOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute contains the operational attributes for the
AtmSignalling component."
::= { atmIfIispSig 12 }
atmIfIispSigOperEntry OBJECT-TYPE
SYNTAX AtmIfIispSigOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispSigOperTable."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispSigIndex }
::= { atmIfIispSigOperTable 1 }
AtmIfIispSigOperEntry ::= SEQUENCE {
atmIfIispSigLastTxCauseCode
Unsigned32,
atmIfIispSigLastTxDiagCode
Hex,
atmIfIispSigLastRxCauseCode
Unsigned32,
atmIfIispSigLastRxDiagCode
Hex }
atmIfIispSigLastTxCauseCode OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the cause code in the last transmitted
signalling message that contains the CAUSE information element.
The cause code is used to describe the reason for generating certain
signalling messages."
::= { atmIfIispSigOperEntry 1 }
atmIfIispSigLastTxDiagCode OBJECT-TYPE
SYNTAX Hex (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute contains the diagnostic code in the last transmitted
signalling message. The diagnostic code is contained in the CAUSE
information element and identifies an information element type or
timer type. The diagnostic code is present only if a procedural error
is detected by the signalling protocol. A diagnostic code is always
accompanied by the cause code. If there is no failure, this attribute
is set to 0."
::= { atmIfIispSigOperEntry 2 }
atmIfIispSigLastRxCauseCode OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute contains the cause code in the last received signalling
message that contains the CAUSE information element. The cause
code is used to describe the reason for generating certain signalling
messages."
::= { atmIfIispSigOperEntry 3 }
atmIfIispSigLastRxDiagCode OBJECT-TYPE
SYNTAX Hex (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute contains the diagnostic code in the last received
signalling message. The diagnostic code is contained in the CAUSE
information element and identifies an information element type or
timer type. The diagnostic code is present only if a procedural error
is detected by the signalling protocol. A diagnostic code is always
accompanied by the cause code. If there is no failure, this attribute
is set to 0."
::= { atmIfIispSigOperEntry 4 }
atmIfIispSigStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispSigStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute group contains the statistics associated with the
AtmSignalling component."
::= { atmIfIispSig 13 }
atmIfIispSigStatsEntry OBJECT-TYPE
SYNTAX AtmIfIispSigStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispSigStatsTable."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispSigIndex }
::= { atmIfIispSigStatsTable 1 }
AtmIfIispSigStatsEntry ::= SEQUENCE {
atmIfIispSigCurrentConnections
Counter32,
atmIfIispSigPeakConnections
Gauge32,
atmIfIispSigSuccessfulConnections
Counter32,
atmIfIispSigFailedConnections
Counter32,
atmIfIispSigTxPdus
Counter32,
atmIfIispSigRxPdus
Counter32,
atmIfIispSigCurrentPmpConnections
Gauge32,
atmIfIispSigPeakPmpConnections
Gauge32,
atmIfIispSigSuccessfulPmpConnections
Counter32,
atmIfIispSigFailedPmpConnections
Counter32,
atmIfIispSigNewCurrentConnections
Gauge32 }
atmIfIispSigCurrentConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This attribute indicates the total number of currently active
connections."
::= { atmIfIispSigStatsEntry 1 }
atmIfIispSigPeakConnections OBJECT-TYPE
SYNTAX Gauge32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the high water mark of active point-to-
point and point-to-multipoint connections."
::= { atmIfIispSigStatsEntry 2 }
atmIfIispSigSuccessfulConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of switched point-to-
point and point-to-multipoint connections that were successfully
established. The counter wraps to 0 when the maximum value is
exceeded."
::= { atmIfIispSigStatsEntry 3 }
atmIfIispSigFailedConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of switched connections that
were not successfully established.The counter wraps to 0 when the
maximum value is exceeded."
::= { atmIfIispSigStatsEntry 4 }
atmIfIispSigTxPdus OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of transmitted signalling
PDUs.The counter wraps to 0 when the maximum value is
exceeded."
::= { atmIfIispSigStatsEntry 5 }
atmIfIispSigRxPdus OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of received signalling PDUs.The
counter wraps to 0 when the maximum value is exceeded."
::= { atmIfIispSigStatsEntry 6 }
atmIfIispSigCurrentPmpConnections OBJECT-TYPE
SYNTAX Gauge32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the number of currently active point-to-
multipoint connections."
::= { atmIfIispSigStatsEntry 7 }
atmIfIispSigPeakPmpConnections OBJECT-TYPE
SYNTAX Gauge32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the high water mark of active point-to-
multipoint connections."
::= { atmIfIispSigStatsEntry 8 }
atmIfIispSigSuccessfulPmpConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of switched point-to-
multipoint connections that were successfully established.
The counter wraps to 0 when the maximum value is
exceeded."
::= { atmIfIispSigStatsEntry 9 }
atmIfIispSigFailedPmpConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of switched point-to-
multipoint connections that were not successfully
established.The counter wraps to 0 when the maximum value
is exceeded."
::= { atmIfIispSigStatsEntry 10 }
atmIfIispSigNewCurrentConnections OBJECT-TYPE
SYNTAX Gauge32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the total number of currently active point-to-
point and point-to-multipoint connections."
::= { atmIfIispSigStatsEntry 11 }
atmIfIispSigVcd OBJECT IDENTIFIER ::= { atmIfIispSig 2 }
atmIfIispSigVcdRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispSigVcdRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfIispSigVcd components."
::= { atmIfIispSigVcd 1 }
atmIfIispSigVcdRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfIispSigVcdRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfIispSigVcd component."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispSigIndex,
atmIfIispSigVcdIndex }
::= { atmIfIispSigVcdRowStatusTable 1 }
AtmIfIispSigVcdRowStatusEntry ::= SEQUENCE {
atmIfIispSigVcdRowStatus
RowStatus,
atmIfIispSigVcdComponentName
DisplayString,
atmIfIispSigVcdStorageType
StorageType,
atmIfIispSigVcdIndex
NonReplicated }
atmIfIispSigVcdRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfIispSigVcd components.
These components can be added and deleted."
::= { atmIfIispSigVcdRowStatusEntry 1 }
atmIfIispSigVcdComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfIispSigVcdRowStatusEntry 2 }
atmIfIispSigVcdStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfIispSigVcd tables."
::= { atmIfIispSigVcdRowStatusEntry 4 }
atmIfIispSigVcdIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfIispSigVcd tables."
::= { atmIfIispSigVcdRowStatusEntry 10 }
atmIfIispSigVcdProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispSigVcdProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the provisionable traffic attributes for a control
channel."
::= { atmIfIispSigVcd 10 }
atmIfIispSigVcdProvEntry OBJECT-TYPE
SYNTAX AtmIfIispSigVcdProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispSigVcdProvTable."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispSigIndex,
atmIfIispSigVcdIndex }
::= { atmIfIispSigVcdProvTable 1 }
AtmIfIispSigVcdProvEntry ::= SEQUENCE {
atmIfIispSigVcdTrafficDescType
INTEGER,
atmIfIispSigVcdAtmServiceCategory
INTEGER,
atmIfIispSigVcdQosClass
INTEGER,
atmIfIispSigVcdTrafficShaping
INTEGER,
atmIfIispSigVcdUnshapedTransmitQueueing
INTEGER,
atmIfIispSigVcdUsageParameterControl
INTEGER }
atmIfIispSigVcdTrafficDescType OBJECT-TYPE
SYNTAX INTEGER {
n3(3),
n6(6),
n7(7),
n8(8) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the type of traffic management which is
applied to both the transmit and receive direction of this connection
as defined in the ATM Forum. The trafficDescType determines the
number and meaning of the parameters in the trafficDescParm
attribute."
DEFVAL { n6 }
::= { atmIfIispSigVcdProvEntry 1 }
atmIfIispSigVcdAtmServiceCategory OBJECT-TYPE
SYNTAX INTEGER {
unspecifiedBitRate(0),
constantBitRate(1),
rtVariableBitRate(2),
nrtVariableBitRate(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the ATM service category for both directions
of the connection.
The constantBitRate service category is intended for real time
applications, that is those requiring tightly constrained delay and
delay variation, as would be appropriate for voice and video
applications. The consistent availability of a fixed quantity of
bandwidth is considered appropriate for CBR service. Cells which
are delayed beyond the value specified by CellTransfer Delay are
assumed to be of significantly reduce value to the application.
The rtVariableBitRate service category is intended for real time
applications, that is those requiring tightly constrained delay and
delay variation, as would be appropriate for voice and video
applications. Sources are expected to transmit at a rate which varies
with time. Equivalently, the source can be described as 'bursty'.
Cells which are delayed beyond the value specified by CTD are
assumed to be of significantly reduced value to the application. Real
time VBR service may support statistical multiplexing of real time
sources.
The nrtVariableBitRate service category is intended for non-real
time applications which have bursty traffic characteristics and which
can be characterized in terms of a PCR, SCR, and MBS. For those
cells which are transferred within the traffic contract, the application
expects a low cell loss ratio. For all connections, it expects a bound
on the mean cell transfer delay. Non-real time VBR service may
support statistical multiplexing of connections.
The unspecifiedBitRate service is intended for non-real time
applications; that is, those not requiring tightly constrained delay
and delay variation. UBR sources are expected to be bursty. UBR
service supports a high degree of statistical multiplexing among
sources. UBR service does not specify traffic related service
guarantees. No numerical commitments are made with respect to
the cell loss ratio experienced by a UBR connection, or as to the
cell transfer delay experienced by cells on the connection."
DEFVAL { rtVariableBitRate }
::= { atmIfIispSigVcdProvEntry 3 }
atmIfIispSigVcdQosClass OBJECT-TYPE
SYNTAX INTEGER {
n0(0),
n1(1),
n2(2),
n3(3),
n4(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the quality of service for both the forward
and backward direction for this connection.
Class 1 supports a QOS that meets Service Class A performance
requirements (Circuit emulation, constant bit rate video).
Class 2 supports a QOS that meets Service Class B performance
requirements (Variable bit rate audio and video).
Class 3 supports a QOS that meets Service Class C performance
requirements (Connection-Oriented Data Transfer).
Class 4 supports a QOS that meets Service Class D performance
requirements (Connectionless Data Transfer).
Class 0 is the unspecified bit rate QOS class; no objective is
specified for the performance parameters."
DEFVAL { n2 }
::= { atmIfIispSigVcdProvEntry 21 }
atmIfIispSigVcdTrafficShaping OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
sameAsCa(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether this connection uses traffic shaping
when transmitting traffic to the ATM interface.
When sameAsCa is selected, traffic shaping for this connection is
based on the trafficShaping attribute of the connection's service
category component under the AtmIf CA. If the service category has
traffic shaping enabled, then traffic shaping is enabled for the
connection. Note that enabling traffic shaping may have no effect
under certain cases. These cases are listed in the description of the
trafficShaping operational attribute, which is under the Vcc Tm and
Vpc Tm components.
When disabled is selected, traffic shaping for this connection is
disabled."
DEFVAL { disabled }
::= { atmIfIispSigVcdProvEntry 50 }
atmIfIispSigVcdUnshapedTransmitQueueing OBJECT-TYPE
SYNTAX INTEGER {
common(1),
sameAsCa(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute only applies when this connection is unshaped. This
attribute specifies the transmit queueing method for this connection
if it is unshaped. Refer to the unshapedTransmitQueueing attribute
under the AtmIf CA service category subcomponent for more details
on the meaning of this attribute.
When this attribute is set to sameAsCa, the transmit queueing
method for the connection is based on the
unshapedTransmitQueueing attribute of the connection's service
category component under the ConnectionAdministrator.
When this attribute is set to common, transmit traffic on this
unshaped connection is destined for the common queue.
The value sameAsInterface is for migration from previous software
releases, but should no longer be used"
DEFVAL { sameAsCa }
::= { atmIfIispSigVcdProvEntry 60 }
atmIfIispSigVcdUsageParameterControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
sameAsCa(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether this connection enforces usage
parameter control when receiving traffic from the ATM interface.
When sameAsCa is selected, UPC for the connection is based on
the usageParameterControl attribute of the connection's service
category component under the ConnectionAdministrator. If the
service category has UPC enabled, then UPC is enabled for the
connection. Note that enabling UPC may have no effect under
certain cases. These cases are listed in the description of the
usageParameterControl operational attribute, which is under the
Vcc Tm or Vpc Tm component.
When disabled is selected, UPC for this connection is disabled.
The value sameAsInterface is for migration from previous software
releases, but should no longer be used"
DEFVAL { disabled }
::= { atmIfIispSigVcdProvEntry 70 }
atmIfIispSigVcdTdpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispSigVcdTdpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute is a vector of five traffic parameters whose meanings
are defined by the trafficDescType attribute. The values of peak cell
rate (PCR), sustained cell rate (SCR) and requested shaping rate are
expressed in cell/s. Maximum burst size (MBS) is expressed in
cells. CDVT is expressed in microseconds. The values of PCR,
SCR, MBS and CDVT are used for connection admission control
(CAC). The value of CDVT is only used for connections where the
atmServiceCategory is constantBitRate. For all other values of
atmServiceCategory, CDVT is ignored. The values of PCR, SCR
and requested shaping rate are used to determine the actual shaping
rate where traffic shaping is enabled.
When trafficDescType is 3, parameter 1 represents the PCR for CLP
equal to 0 and 1 traffic; parameter 4 represents the CDVT; and
parameter 5 represents the requested shaping rate. A non-zero value
in parameter 5 overrides any value in parameter 1. This result is
used as the PCR. Parameter 1 must be non-zero. Parameters 2 and 3
must be zero.
When trafficDescType is 6, parameter 1 represents the PCR for CLP
equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP
equal to 0 and 1 traffic; parameter 3 represents the MBS for CLP
equal to 0 and 1 traffic; parameter 4 represents the CDVT; and
parameter 5 represents the requested shaping rate. A non-zero value
in parameter 5 overrides any value in parameter 1. This result is
used as the PCR. Parameters 1, 2, and 3 must be non-zero.
Parameter 1 must be greater than or equal to parameter 2. Parameter
5 must either be zero (unused) or greater than or equal to parameter
2.
When trafficDescType is 7, parameter 1 represents the PCR for CLP
equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP
equal to 0 with cell discard; parameter 3 represents the MBS for
CLP equal to 0 traffic; parameter 4 represents the CDVT; and
parameter 5 represents the requested shaping rate. A non-zero value
in parameter 5 overrides any value in parameter 1. This result is
used as the PCR. Parameters 1, 2, and 3 must be non-zero.
Parameter 1 must be greater than or equal to parameter 2. Parameter
5 must either be zero (unused) or greater than or equal to parameter
2.
When trafficDescType is 8, parameter 1 represents the PCR for CLP
equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP
equal to 0 traffic with cell tagging; parameter 3 represents the MBS
for CLP equal to 0 traffic; parameter 4 represents the CDVT; and
parameter 5 represents the requested shaping rate. A non-zero value
in parameter 5 overrides any value in parameter 1. This result is
used as the PCR. Parameters 1, 2, and 3 must be non-zero.
Parameter 1 must be greater than or equal to parameter 2. Parameter
5 must either be zero (unused) or greater than or equal to parameter
2.
Whenever it is valid for PCR to be specified, parameter 5 may also
be used to specify a requested shaping rate. A non-zero value in
parameter 5 overrides the value in parameter 1 and is used as the
peak cell rate in calculations of CAC and shaping rate.
For trafficDescType 3 the traffic is shaped at the next rate less than
the PCR.
For trafficDescType 6, 7, and 8, the traffic is shaped at the highest
available rate which is between PCR and SCR. However, if there is
no available shaping rate between PCR and SCR, traffic is shaped at
the next rate above the PCR."
::= { atmIfIispSigVcd 387 }
atmIfIispSigVcdTdpEntry OBJECT-TYPE
SYNTAX AtmIfIispSigVcdTdpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispSigVcdTdpTable."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispSigIndex,
atmIfIispSigVcdIndex,
atmIfIispSigVcdTdpIndex }
::= { atmIfIispSigVcdTdpTable 1 }
AtmIfIispSigVcdTdpEntry ::= SEQUENCE {
atmIfIispSigVcdTdpIndex
Integer32,
atmIfIispSigVcdTdpValue
Unsigned32 }
atmIfIispSigVcdTdpIndex OBJECT-TYPE
SYNTAX Integer32 (1..5)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the atmIfIispSigVcdTdpTable
specific index for the atmIfIispSigVcdTdpTable."
::= { atmIfIispSigVcdTdpEntry 1 }
atmIfIispSigVcdTdpValue OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable represents an individual value for the
atmIfIispSigVcdTdpTable."
::= { atmIfIispSigVcdTdpEntry 2 }
atmIfIispAddr OBJECT IDENTIFIER ::= { atmIfIisp 4 }
atmIfIispAddrRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispAddrRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfIispAddr components."
::= { atmIfIispAddr 1 }
atmIfIispAddrRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfIispAddrRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfIispAddr component."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispAddrAddressIndex,
atmIfIispAddrAddressTypeIndex }
::= { atmIfIispAddrRowStatusTable 1 }
AtmIfIispAddrRowStatusEntry ::= SEQUENCE {
atmIfIispAddrRowStatus
RowStatus,
atmIfIispAddrComponentName
DisplayString,
atmIfIispAddrStorageType
StorageType,
atmIfIispAddrAddressIndex
AsciiStringIndex,
atmIfIispAddrAddressTypeIndex
INTEGER }
atmIfIispAddrRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfIispAddr components.
These components can be added and deleted."
::= { atmIfIispAddrRowStatusEntry 1 }
atmIfIispAddrComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfIispAddrRowStatusEntry 2 }
atmIfIispAddrStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfIispAddr tables."
::= { atmIfIispAddrRowStatusEntry 4 }
atmIfIispAddrAddressIndex OBJECT-TYPE
SYNTAX AsciiStringIndex (SIZE (1..40))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents an index for the atmIfIispAddr tables."
::= { atmIfIispAddrRowStatusEntry 10 }
atmIfIispAddrAddressTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
primary(0),
alternate(1),
default(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents an index for the atmIfIispAddr tables."
::= { atmIfIispAddrRowStatusEntry 11 }
atmIfIispAddrOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispAddrOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute group contains the operational attributes for the
Address component."
::= { atmIfIispAddr 10 }
atmIfIispAddrOperEntry OBJECT-TYPE
SYNTAX AtmIfIispAddrOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispAddrOperTable."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispAddrAddressIndex,
atmIfIispAddrAddressTypeIndex }
::= { atmIfIispAddrOperTable 1 }
AtmIfIispAddrOperEntry ::= SEQUENCE {
atmIfIispAddrScope
INTEGER,
atmIfIispAddrReachability
INTEGER }
atmIfIispAddrScope OBJECT-TYPE
SYNTAX INTEGER (-1..104)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the scope of the ATM address, which is the
highest level to which this address will be advertised in the PNNI
hierarchy. If no PnniInfo subcomponent has been provisioned, then
the scope will default to the level of this node in the PNNI
hierarchy. If this node does not participate in a PNNI hierarchy, then
this attribute will have the value of -1."
::= { atmIfIispAddrOperEntry 1 }
atmIfIispAddrReachability OBJECT-TYPE
SYNTAX INTEGER {
internal(0),
exterior(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates whether the address is internal or exterior.
An internal reachable address is an address of a destination that is
directly attached to the logical node advertising the address. An
exterior reachable address is an address that can be reached
through a PNNI routing domain, but which is not located in that
PNNI routing domain."
::= { atmIfIispAddrOperEntry 2 }
atmIfIispAddrTermSP OBJECT IDENTIFIER ::= { atmIfIispAddr 2 }
atmIfIispAddrTermSPRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispAddrTermSPRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfIispAddrTermSP components."
::= { atmIfIispAddrTermSP 1 }
atmIfIispAddrTermSPRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfIispAddrTermSPRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfIispAddrTermSP component."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispAddrAddressIndex,
atmIfIispAddrAddressTypeIndex,
atmIfIispAddrTermSPIndex }
::= { atmIfIispAddrTermSPRowStatusTable 1 }
AtmIfIispAddrTermSPRowStatusEntry ::= SEQUENCE {
atmIfIispAddrTermSPRowStatus
RowStatus,
atmIfIispAddrTermSPComponentName
DisplayString,
atmIfIispAddrTermSPStorageType
StorageType,
atmIfIispAddrTermSPIndex
NonReplicated }
atmIfIispAddrTermSPRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfIispAddrTermSP components.
These components can be added and deleted."
::= { atmIfIispAddrTermSPRowStatusEntry 1 }
atmIfIispAddrTermSPComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfIispAddrTermSPRowStatusEntry 2 }
atmIfIispAddrTermSPStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfIispAddrTermSP tables."
::= { atmIfIispAddrTermSPRowStatusEntry 4 }
atmIfIispAddrTermSPIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfIispAddrTermSP tables."
::= { atmIfIispAddrTermSPRowStatusEntry 10 }
atmIfIispAddrPnniInfo OBJECT IDENTIFIER ::= { atmIfIispAddr 3 }
atmIfIispAddrPnniInfoRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispAddrPnniInfoRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfIispAddrPnniInfo components."
::= { atmIfIispAddrPnniInfo 1 }
atmIfIispAddrPnniInfoRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfIispAddrPnniInfoRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfIispAddrPnniInfo component."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispAddrAddressIndex,
atmIfIispAddrAddressTypeIndex,
atmIfIispAddrPnniInfoIndex }
::= { atmIfIispAddrPnniInfoRowStatusTable 1 }
AtmIfIispAddrPnniInfoRowStatusEntry ::= SEQUENCE {
atmIfIispAddrPnniInfoRowStatus
RowStatus,
atmIfIispAddrPnniInfoComponentName
DisplayString,
atmIfIispAddrPnniInfoStorageType
StorageType,
atmIfIispAddrPnniInfoIndex
NonReplicated }
atmIfIispAddrPnniInfoRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfIispAddrPnniInfo components.
These components can be added and deleted."
::= { atmIfIispAddrPnniInfoRowStatusEntry 1 }
atmIfIispAddrPnniInfoComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfIispAddrPnniInfoRowStatusEntry 2 }
atmIfIispAddrPnniInfoStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfIispAddrPnniInfo tables."
::= { atmIfIispAddrPnniInfoRowStatusEntry 4 }
atmIfIispAddrPnniInfoIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfIispAddrPnniInfo tables."
::= { atmIfIispAddrPnniInfoRowStatusEntry 10 }
atmIfIispAddrPnniInfoProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfIispAddrPnniInfoProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute group contains the provisioned attributes relating to
PNNI for a PnniInfo component."
::= { atmIfIispAddrPnniInfo 10 }
atmIfIispAddrPnniInfoProvEntry OBJECT-TYPE
SYNTAX AtmIfIispAddrPnniInfoProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfIispAddrPnniInfoProvTable."
INDEX {
atmIfIndex,
atmIfIispIndex,
atmIfIispAddrAddressIndex,
atmIfIispAddrAddressTypeIndex,
atmIfIispAddrPnniInfoIndex }
::= { atmIfIispAddrPnniInfoProvTable 1 }
AtmIfIispAddrPnniInfoProvEntry ::= SEQUENCE {
atmIfIispAddrPnniInfoScope
INTEGER,
atmIfIispAddrPnniInfoReachability
INTEGER }
atmIfIispAddrPnniInfoScope OBJECT-TYPE
SYNTAX INTEGER (-1..104)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the scope of the ATM address, which is the
highest level up to which this address will be advertised in the
PNNI hierarchy. The scope must be set to a value numerically less
than or equal to the level of the lowest level peer group containing
this node. Setting the scope to 0 will cause the address to be
advertised globally within this PNNI routing domain."
DEFVAL { -1 }
::= { atmIfIispAddrPnniInfoProvEntry 1 }
atmIfIispAddrPnniInfoReachability OBJECT-TYPE
SYNTAX INTEGER {
internal(0),
exterior(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute indicates whether the address is internal or exterior.
An internal reachable address is an address of a destination that is
directly attached to the logical node advertising the address. An
exterior reachable address is an address that can be reached
through a PNNI routing domain, but which is not located in that
PNNI routing domain."
DEFVAL { internal }
::= { atmIfIispAddrPnniInfoProvEntry 2 }
atmIfVptIisp OBJECT IDENTIFIER ::= { atmIfVpt 6 }
atmIfVptIispRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfVptIisp components."
::= { atmIfVptIisp 1 }
atmIfVptIispRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfVptIispRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfVptIisp component."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex }
::= { atmIfVptIispRowStatusTable 1 }
AtmIfVptIispRowStatusEntry ::= SEQUENCE {
atmIfVptIispRowStatus
RowStatus,
atmIfVptIispComponentName
DisplayString,
atmIfVptIispStorageType
StorageType,
atmIfVptIispIndex
NonReplicated }
atmIfVptIispRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfVptIisp components.
These components can be added and deleted."
::= { atmIfVptIispRowStatusEntry 1 }
atmIfVptIispComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfVptIispRowStatusEntry 2 }
atmIfVptIispStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfVptIisp tables."
::= { atmIfVptIispRowStatusEntry 4 }
atmIfVptIispIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfVptIisp tables."
::= { atmIfVptIispRowStatusEntry 10 }
atmIfVptIispProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the provisionable attributes for the Iisp
component."
::= { atmIfVptIisp 10 }
atmIfVptIispProvEntry OBJECT-TYPE
SYNTAX AtmIfVptIispProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispProvTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex }
::= { atmIfVptIispProvTable 1 }
AtmIfVptIispProvEntry ::= SEQUENCE {
atmIfVptIispVersion
INTEGER,
atmIfVptIispSide
INTEGER,
atmIfVptIispSoftPvcRetryPeriod
Unsigned32,
atmIfVptIispSoftPvpAndPvcRetryPeriod
Unsigned32,
atmIfVptIispSoftPvpAndPvcHoldOffTime
Unsigned32 }
atmIfVptIispVersion OBJECT-TYPE
SYNTAX INTEGER {
iisp10Sig30(2),
iisp10Sig31(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute indicates which specification the IISP interface
complies with. The options are iisp10Sig30 which refers to IISP
version 1.0 with 3.0 signalling and iisp10Sig31 which refers to IISP
version 1.0 with 3.1 signalling. If this attribute is changed, all
switched Vcc components in this interface are cleared due to the
fact that the two versions are incompatible."
DEFVAL { iisp10Sig31 }
::= { atmIfVptIispProvEntry 1 }
atmIfVptIispSide OBJECT-TYPE
SYNTAX INTEGER {
networkSide(0),
userSide(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute indicates which side the interface is, user or network."
DEFVAL { networkSide }
::= { atmIfVptIispProvEntry 2 }
atmIfVptIispSoftPvcRetryPeriod OBJECT-TYPE
SYNTAX Unsigned32 (20..999999)
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This attribute specifies the time to wait between call set up retries.
The resolution is to the nearest 10 seconds.
This attribute has been obsoleted and is replaced by the
softPvpAndPvcRetryPeriod attribute."
DEFVAL { 60 }
::= { atmIfVptIispProvEntry 3 }
atmIfVptIispSoftPvpAndPvcRetryPeriod OBJECT-TYPE
SYNTAX Unsigned32 (20..999999)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the time to wait between soft PVP or soft
PVC call setup retries. The resolution is to the nearest 10 seconds."
DEFVAL { 60 }
::= { atmIfVptIispProvEntry 4 }
atmIfVptIispSoftPvpAndPvcHoldOffTime OBJECT-TYPE
SYNTAX Unsigned32 (0 | 50..20000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies how long to hold off retries following a
release or the connection. The resolution is to the nearest 50 ms."
DEFVAL { 0 }
::= { atmIfVptIispProvEntry 5 }
atmIfVptIispAcctOptTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispAcctOptEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the provisionable attributes for accounting."
::= { atmIfVptIisp 11 }
atmIfVptIispAcctOptEntry OBJECT-TYPE
SYNTAX AtmIfVptIispAcctOptEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispAcctOptTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex }
::= { atmIfVptIispAcctOptTable 1 }
AtmIfVptIispAcctOptEntry ::= SEQUENCE {
atmIfVptIispAccountCollection
OCTET STRING,
atmIfVptIispAccountConnectionType
INTEGER,
atmIfVptIispAccountClass
Unsigned32,
atmIfVptIispServiceExchange
Unsigned32 }
atmIfVptIispAccountCollection OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute is used to turn accounting on or off for SVC and
SPVC connections. It also specifies the reason(s) for which
accounting data is collected: billing, test, study, audit, or force.
If the set of reasons is not empty then accounting records will be
generated by this interface in the following situations:
- on a TODA changeover if TODA is enabled;
- every 12 hours (per connection) if TODA is disabled;
- on every call clear (a call record with final cell counts).
If none of the reasons is present, then accounting will be
suppressed.
The reason for collection is recorded in the accounting record, in
the attribute callingCollectReason or calledCollectReason as
appropriate.
Description of bits:
bill(0)
test(1)
study(2)
audit(3)
force(4)"
::= { atmIfVptIispAcctOptEntry 1 }
atmIfVptIispAccountConnectionType OBJECT-TYPE
SYNTAX INTEGER {
origTerm(0),
intermediate(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether accounting records generated by
this interface should be marked as originating, terminating or
intermediate. This attribute, in combination with the direction of the
call, determines the value of attribute connPointType of the
accounting record and may be used by downstream accounting
processes to correlate the records.
If the value is origTerm then records generated for incoming calls
will be marked as originating and records generated for outgoing
calls will be marked as terminating.
If the value is intermediate then records generated for all calls will
be marked as intermediate."
DEFVAL { intermediate }
::= { atmIfVptIispAcctOptEntry 2 }
atmIfVptIispAccountClass OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the accounting class associated with the
interface. Its meaning is determined by the network operator.
Its value is simply recorded in the accounting records generated by
this interface, in the attribute callingServiceType or
calledServiceType as appropriate."
DEFVAL { 0 }
::= { atmIfVptIispAcctOptEntry 3 }
atmIfVptIispServiceExchange OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the data service exchange associated with
this interface. Its meaning is determined by the network operator.
Its value is simply recorded in the accounting records generated by
this interface, in the attribute callingDse or calledDse as
appropriate."
DEFVAL { 0 }
::= { atmIfVptIispAcctOptEntry 4 }
atmIfVptIispVProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispVProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the provisionable attributes for the Iisp
component which are specific to virtual IISP interfaces."
::= { atmIfVptIisp 12 }
atmIfVptIispVProvEntry OBJECT-TYPE
SYNTAX AtmIfVptIispVProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispVProvTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex }
::= { atmIfVptIispVProvTable 1 }
AtmIfVptIispVProvEntry ::= SEQUENCE {
atmIfVptIispVpci
Unsigned32 }
atmIfVptIispVpci OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the Virtual Path Connection Identifier
(VPCI) to be used between this signalling entity and its peer. The
VPCI of the peer virtual IISP must have the same value for
switched connections to be set up across the interface."
DEFVAL { 0 }
::= { atmIfVptIispVProvEntry 1 }
atmIfVptIispSig OBJECT IDENTIFIER ::= { atmIfVptIisp 3 }
atmIfVptIispSigRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispSigRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfVptIispSig components."
::= { atmIfVptIispSig 1 }
atmIfVptIispSigRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfVptIispSigRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfVptIispSig component."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispSigIndex }
::= { atmIfVptIispSigRowStatusTable 1 }
AtmIfVptIispSigRowStatusEntry ::= SEQUENCE {
atmIfVptIispSigRowStatus
RowStatus,
atmIfVptIispSigComponentName
DisplayString,
atmIfVptIispSigStorageType
StorageType,
atmIfVptIispSigIndex
NonReplicated }
atmIfVptIispSigRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfVptIispSig components.
These components cannot be added nor deleted."
::= { atmIfVptIispSigRowStatusEntry 1 }
atmIfVptIispSigComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfVptIispSigRowStatusEntry 2 }
atmIfVptIispSigStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfVptIispSig tables."
::= { atmIfVptIispSigRowStatusEntry 4 }
atmIfVptIispSigIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfVptIispSig tables."
::= { atmIfVptIispSigRowStatusEntry 10 }
atmIfVptIispSigProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispSigProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute group contains the provisionable attributes for the
Signalling component."
::= { atmIfVptIispSig 10 }
atmIfVptIispSigProvEntry OBJECT-TYPE
SYNTAX AtmIfVptIispSigProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispSigProvTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispSigIndex }
::= { atmIfVptIispSigProvTable 1 }
AtmIfVptIispSigProvEntry ::= SEQUENCE {
atmIfVptIispSigVci
Unsigned32,
atmIfVptIispSigAddressConversion
INTEGER }
atmIfVptIispSigVci OBJECT-TYPE
SYNTAX Unsigned32 (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the signalling channel number."
DEFVAL { 5 }
::= { atmIfVptIispSigProvEntry 1 }
atmIfVptIispSigAddressConversion OBJECT-TYPE
SYNTAX INTEGER {
none(0),
nativeE164(1),
nsap(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the address conversion on the outgoing
signalling PDUs. The options are none, nativeE164, or nsap. The
none option is the default and if this option is chosen then nothing
is done to the address information element (IE) in the outgoing
signalling message. If nativeE164 option is chosen, then only
NSAP encapsulated E.164 addresses with zeros in the ESI are
converted to native E.164 format in the outgoing signalling
message. If the NSAP address is not encapsulated E.164 or the ESI
field is not zeros and the nativeE164 option is chosen, then the call
is cleared. If the nsap option is chosen, then native E.164 addresses
are converted to NSAP E.164 with zeros in the ESI field; otherwise
the address is in NSAP format and is not changed."
DEFVAL { none }
::= { atmIfVptIispSigProvEntry 2 }
atmIfVptIispSigStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispSigStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the three OSI State attributes. The descriptions
generically indicate what each state attribute implies about the
component. Note that not all the values and state combinations
described here are supported by every component which uses this
group. For component-specific information and the valid state
combinations, refer to NTP 241-7001-150, Passport Operations and
Maintenance Guide."
::= { atmIfVptIispSig 11 }
atmIfVptIispSigStateEntry OBJECT-TYPE
SYNTAX AtmIfVptIispSigStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispSigStateTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispSigIndex }
::= { atmIfVptIispSigStateTable 1 }
AtmIfVptIispSigStateEntry ::= SEQUENCE {
atmIfVptIispSigAdminState
INTEGER,
atmIfVptIispSigOperationalState
INTEGER,
atmIfVptIispSigUsageState
INTEGER }
atmIfVptIispSigAdminState OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
unlocked(1),
shuttingDown(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component."
DEFVAL { unlocked }
::= { atmIfVptIispSigStateEntry 1 }
atmIfVptIispSigOperationalState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle."
DEFVAL { disabled }
::= { atmIfVptIispSigStateEntry 2 }
atmIfVptIispSigUsageState OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
active(1),
busy(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time."
DEFVAL { idle }
::= { atmIfVptIispSigStateEntry 3 }
atmIfVptIispSigOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispSigOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute contains the operational attributes for the
AtmSignalling component."
::= { atmIfVptIispSig 12 }
atmIfVptIispSigOperEntry OBJECT-TYPE
SYNTAX AtmIfVptIispSigOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispSigOperTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispSigIndex }
::= { atmIfVptIispSigOperTable 1 }
AtmIfVptIispSigOperEntry ::= SEQUENCE {
atmIfVptIispSigLastTxCauseCode
Unsigned32,
atmIfVptIispSigLastTxDiagCode
Hex,
atmIfVptIispSigLastRxCauseCode
Unsigned32,
atmIfVptIispSigLastRxDiagCode
Hex }
atmIfVptIispSigLastTxCauseCode OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the cause code in the last transmitted
signalling message that contains the CAUSE information element.
The cause code is used to describe the reason for generating certain
signalling messages."
::= { atmIfVptIispSigOperEntry 1 }
atmIfVptIispSigLastTxDiagCode OBJECT-TYPE
SYNTAX Hex (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute contains the diagnostic code in the last transmitted
signalling message. The diagnostic code is contained in the CAUSE
information element and identifies an information element type or
timer type. The diagnostic code is present only if a procedural error
is detected by the signalling protocol. A diagnostic code is always
accompanied by the cause code. If there is no failure, this attribute
is set to 0."
::= { atmIfVptIispSigOperEntry 2 }
atmIfVptIispSigLastRxCauseCode OBJECT-TYPE
SYNTAX Unsigned32 (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute contains the cause code in the last received signalling
message that contains the CAUSE information element. The cause
code is used to describe the reason for generating certain signalling
messages."
::= { atmIfVptIispSigOperEntry 3 }
atmIfVptIispSigLastRxDiagCode OBJECT-TYPE
SYNTAX Hex (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute contains the diagnostic code in the last received
signalling message. The diagnostic code is contained in the CAUSE
information element and identifies an information element type or
timer type. The diagnostic code is present only if a procedural error
is detected by the signalling protocol. A diagnostic code is always
accompanied by the cause code. If there is no failure, this attribute
is set to 0."
::= { atmIfVptIispSigOperEntry 4 }
atmIfVptIispSigStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispSigStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute group contains the statistics associated with the
AtmSignalling component."
::= { atmIfVptIispSig 13 }
atmIfVptIispSigStatsEntry OBJECT-TYPE
SYNTAX AtmIfVptIispSigStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispSigStatsTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispSigIndex }
::= { atmIfVptIispSigStatsTable 1 }
AtmIfVptIispSigStatsEntry ::= SEQUENCE {
atmIfVptIispSigCurrentConnections
Counter32,
atmIfVptIispSigPeakConnections
Gauge32,
atmIfVptIispSigSuccessfulConnections
Counter32,
atmIfVptIispSigFailedConnections
Counter32,
atmIfVptIispSigTxPdus
Counter32,
atmIfVptIispSigRxPdus
Counter32,
atmIfVptIispSigCurrentPmpConnections
Gauge32,
atmIfVptIispSigPeakPmpConnections
Gauge32,
atmIfVptIispSigSuccessfulPmpConnections
Counter32,
atmIfVptIispSigFailedPmpConnections
Counter32,
atmIfVptIispSigNewCurrentConnections
Gauge32 }
atmIfVptIispSigCurrentConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS obsolete
DESCRIPTION
"This attribute indicates the total number of currently active
connections."
::= { atmIfVptIispSigStatsEntry 1 }
atmIfVptIispSigPeakConnections OBJECT-TYPE
SYNTAX Gauge32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the high water mark of active point-to-
point and point-to-multipoint connections."
::= { atmIfVptIispSigStatsEntry 2 }
atmIfVptIispSigSuccessfulConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of switched point-to-
point and point-to-multipoint connections that were successfully
established. The counter wraps to 0 when the maximum value is
exceeded."
::= { atmIfVptIispSigStatsEntry 3 }
atmIfVptIispSigFailedConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of switched connections that
were not successfully established.The counter wraps to 0 when the
maximum value is exceeded."
::= { atmIfVptIispSigStatsEntry 4 }
atmIfVptIispSigTxPdus OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of transmitted signalling
PDUs.The counter wraps to 0 when the maximum value is
exceeded."
::= { atmIfVptIispSigStatsEntry 5 }
atmIfVptIispSigRxPdus OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of received signalling PDUs.The
counter wraps to 0 when the maximum value is exceeded."
::= { atmIfVptIispSigStatsEntry 6 }
atmIfVptIispSigCurrentPmpConnections OBJECT-TYPE
SYNTAX Gauge32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the number of currently active point-to-
multipoint connections."
::= { atmIfVptIispSigStatsEntry 7 }
atmIfVptIispSigPeakPmpConnections OBJECT-TYPE
SYNTAX Gauge32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the high water mark of active point-to-
multipoint connections."
::= { atmIfVptIispSigStatsEntry 8 }
atmIfVptIispSigSuccessfulPmpConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of switched point-to-
multipoint connections that were successfully established.
The counter wraps to 0 when the maximum value is
exceeded."
::= { atmIfVptIispSigStatsEntry 9 }
atmIfVptIispSigFailedPmpConnections OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of switched point-to-
multipoint connections that were not successfully
established.The counter wraps to 0 when the maximum value
is exceeded."
::= { atmIfVptIispSigStatsEntry 10 }
atmIfVptIispSigNewCurrentConnections OBJECT-TYPE
SYNTAX Gauge32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the total number of currently active point-to-
point and point-to-multipoint connections."
::= { atmIfVptIispSigStatsEntry 11 }
atmIfVptIispSigVcd OBJECT IDENTIFIER ::= { atmIfVptIispSig 2 }
atmIfVptIispSigVcdRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispSigVcdRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfVptIispSigVcd components."
::= { atmIfVptIispSigVcd 1 }
atmIfVptIispSigVcdRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfVptIispSigVcdRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfVptIispSigVcd component."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispSigIndex,
atmIfVptIispSigVcdIndex }
::= { atmIfVptIispSigVcdRowStatusTable 1 }
AtmIfVptIispSigVcdRowStatusEntry ::= SEQUENCE {
atmIfVptIispSigVcdRowStatus
RowStatus,
atmIfVptIispSigVcdComponentName
DisplayString,
atmIfVptIispSigVcdStorageType
StorageType,
atmIfVptIispSigVcdIndex
NonReplicated }
atmIfVptIispSigVcdRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfVptIispSigVcd components.
These components can be added and deleted."
::= { atmIfVptIispSigVcdRowStatusEntry 1 }
atmIfVptIispSigVcdComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfVptIispSigVcdRowStatusEntry 2 }
atmIfVptIispSigVcdStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfVptIispSigVcd tables."
::= { atmIfVptIispSigVcdRowStatusEntry 4 }
atmIfVptIispSigVcdIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfVptIispSigVcd tables."
::= { atmIfVptIispSigVcdRowStatusEntry 10 }
atmIfVptIispSigVcdProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispSigVcdProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the provisionable traffic attributes for a control
channel."
::= { atmIfVptIispSigVcd 10 }
atmIfVptIispSigVcdProvEntry OBJECT-TYPE
SYNTAX AtmIfVptIispSigVcdProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispSigVcdProvTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispSigIndex,
atmIfVptIispSigVcdIndex }
::= { atmIfVptIispSigVcdProvTable 1 }
AtmIfVptIispSigVcdProvEntry ::= SEQUENCE {
atmIfVptIispSigVcdTrafficDescType
INTEGER,
atmIfVptIispSigVcdAtmServiceCategory
INTEGER,
atmIfVptIispSigVcdQosClass
INTEGER,
atmIfVptIispSigVcdTrafficShaping
INTEGER,
atmIfVptIispSigVcdUnshapedTransmitQueueing
INTEGER,
atmIfVptIispSigVcdUsageParameterControl
INTEGER }
atmIfVptIispSigVcdTrafficDescType OBJECT-TYPE
SYNTAX INTEGER {
n3(3),
n6(6),
n7(7),
n8(8) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the type of traffic management which is
applied to both the transmit and receive direction of this connection
as defined in the ATM Forum. The trafficDescType determines the
number and meaning of the parameters in the trafficDescParm
attribute."
DEFVAL { n6 }
::= { atmIfVptIispSigVcdProvEntry 1 }
atmIfVptIispSigVcdAtmServiceCategory OBJECT-TYPE
SYNTAX INTEGER {
unspecifiedBitRate(0),
constantBitRate(1),
rtVariableBitRate(2),
nrtVariableBitRate(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the ATM service category for both directions
of the connection.
The constantBitRate service category is intended for real time
applications, that is those requiring tightly constrained delay and
delay variation, as would be appropriate for voice and video
applications. The consistent availability of a fixed quantity of
bandwidth is considered appropriate for CBR service. Cells which
are delayed beyond the value specified by CellTransfer Delay are
assumed to be of significantly reduce value to the application.
The rtVariableBitRate service category is intended for real time
applications, that is those requiring tightly constrained delay and
delay variation, as would be appropriate for voice and video
applications. Sources are expected to transmit at a rate which varies
with time. Equivalently, the source can be described as 'bursty'.
Cells which are delayed beyond the value specified by CTD are
assumed to be of significantly reduced value to the application. Real
time VBR service may support statistical multiplexing of real time
sources.
The nrtVariableBitRate service category is intended for non-real
time applications which have bursty traffic characteristics and which
can be characterized in terms of a PCR, SCR, and MBS. For those
cells which are transferred within the traffic contract, the application
expects a low cell loss ratio. For all connections, it expects a bound
on the mean cell transfer delay. Non-real time VBR service may
support statistical multiplexing of connections.
The unspecifiedBitRate service is intended for non-real time
applications; that is, those not requiring tightly constrained delay
and delay variation. UBR sources are expected to be bursty. UBR
service supports a high degree of statistical multiplexing among
sources. UBR service does not specify traffic related service
guarantees. No numerical commitments are made with respect to
the cell loss ratio experienced by a UBR connection, or as to the
cell transfer delay experienced by cells on the connection."
DEFVAL { rtVariableBitRate }
::= { atmIfVptIispSigVcdProvEntry 3 }
atmIfVptIispSigVcdQosClass OBJECT-TYPE
SYNTAX INTEGER {
n0(0),
n1(1),
n2(2),
n3(3),
n4(4) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the quality of service for both the forward
and backward direction for this connection.
Class 1 supports a QOS that meets Service Class A performance
requirements (Circuit emulation, constant bit rate video).
Class 2 supports a QOS that meets Service Class B performance
requirements (Variable bit rate audio and video).
Class 3 supports a QOS that meets Service Class C performance
requirements (Connection-Oriented Data Transfer).
Class 4 supports a QOS that meets Service Class D performance
requirements (Connectionless Data Transfer).
Class 0 is the unspecified bit rate QOS class; no objective is
specified for the performance parameters."
DEFVAL { n2 }
::= { atmIfVptIispSigVcdProvEntry 21 }
atmIfVptIispSigVcdTrafficShaping OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
sameAsCa(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether this connection uses traffic shaping
when transmitting traffic to the ATM interface.
When sameAsCa is selected, traffic shaping for this connection is
based on the trafficShaping attribute of the connection's service
category component under the AtmIf CA. If the service category has
traffic shaping enabled, then traffic shaping is enabled for the
connection. Note that enabling traffic shaping may have no effect
under certain cases. These cases are listed in the description of the
trafficShaping operational attribute, which is under the Vcc Tm and
Vpc Tm components.
When disabled is selected, traffic shaping for this connection is
disabled."
DEFVAL { disabled }
::= { atmIfVptIispSigVcdProvEntry 50 }
atmIfVptIispSigVcdUnshapedTransmitQueueing OBJECT-TYPE
SYNTAX INTEGER {
common(1),
sameAsCa(3) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute only applies when this connection is unshaped. This
attribute specifies the transmit queueing method for this connection
if it is unshaped. Refer to the unshapedTransmitQueueing attribute
under the AtmIf CA service category subcomponent for more details
on the meaning of this attribute.
When this attribute is set to sameAsCa, the transmit queueing
method for the connection is based on the
unshapedTransmitQueueing attribute of the connection's service
category component under the ConnectionAdministrator.
When this attribute is set to common, transmit traffic on this
unshaped connection is destined for the common queue.
The value sameAsInterface is for migration from previous software
releases, but should no longer be used"
DEFVAL { sameAsCa }
::= { atmIfVptIispSigVcdProvEntry 60 }
atmIfVptIispSigVcdUsageParameterControl OBJECT-TYPE
SYNTAX INTEGER {
disabled(1),
sameAsCa(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether this connection enforces usage
parameter control when receiving traffic from the ATM interface.
When sameAsCa is selected, UPC for the connection is based on
the usageParameterControl attribute of the connection's service
category component under the ConnectionAdministrator. If the
service category has UPC enabled, then UPC is enabled for the
connection. Note that enabling UPC may have no effect under
certain cases. These cases are listed in the description of the
usageParameterControl operational attribute, which is under the
Vcc Tm or Vpc Tm component.
When disabled is selected, UPC for this connection is disabled.
The value sameAsInterface is for migration from previous software
releases, but should no longer be used"
DEFVAL { disabled }
::= { atmIfVptIispSigVcdProvEntry 70 }
atmIfVptIispSigVcdTdpTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispSigVcdTdpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute is a vector of five traffic parameters whose meanings
are defined by the trafficDescType attribute. The values of peak cell
rate (PCR), sustained cell rate (SCR) and requested shaping rate are
expressed in cell/s. Maximum burst size (MBS) is expressed in
cells. CDVT is expressed in microseconds. The values of PCR,
SCR, MBS and CDVT are used for connection admission control
(CAC). The value of CDVT is only used for connections where the
atmServiceCategory is constantBitRate. For all other values of
atmServiceCategory, CDVT is ignored. The values of PCR, SCR
and requested shaping rate are used to determine the actual shaping
rate where traffic shaping is enabled.
When trafficDescType is 3, parameter 1 represents the PCR for CLP
equal to 0 and 1 traffic; parameter 4 represents the CDVT; and
parameter 5 represents the requested shaping rate. A non-zero value
in parameter 5 overrides any value in parameter 1. This result is
used as the PCR. Parameter 1 must be non-zero. Parameters 2 and 3
must be zero.
When trafficDescType is 6, parameter 1 represents the PCR for CLP
equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP
equal to 0 and 1 traffic; parameter 3 represents the MBS for CLP
equal to 0 and 1 traffic; parameter 4 represents the CDVT; and
parameter 5 represents the requested shaping rate. A non-zero value
in parameter 5 overrides any value in parameter 1. This result is
used as the PCR. Parameters 1, 2, and 3 must be non-zero.
Parameter 1 must be greater than or equal to parameter 2. Parameter
5 must either be zero (unused) or greater than or equal to parameter
2.
When trafficDescType is 7, parameter 1 represents the PCR for CLP
equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP
equal to 0 with cell discard; parameter 3 represents the MBS for
CLP equal to 0 traffic; parameter 4 represents the CDVT; and
parameter 5 represents the requested shaping rate. A non-zero value
in parameter 5 overrides any value in parameter 1. This result is
used as the PCR. Parameters 1, 2, and 3 must be non-zero.
Parameter 1 must be greater than or equal to parameter 2. Parameter
5 must either be zero (unused) or greater than or equal to parameter
2.
When trafficDescType is 8, parameter 1 represents the PCR for CLP
equal to 0 and 1 traffic; parameter 2 represents the SCR for CLP
equal to 0 traffic with cell tagging; parameter 3 represents the MBS
for CLP equal to 0 traffic; parameter 4 represents the CDVT; and
parameter 5 represents the requested shaping rate. A non-zero value
in parameter 5 overrides any value in parameter 1. This result is
used as the PCR. Parameters 1, 2, and 3 must be non-zero.
Parameter 1 must be greater than or equal to parameter 2. Parameter
5 must either be zero (unused) or greater than or equal to parameter
2.
Whenever it is valid for PCR to be specified, parameter 5 may also
be used to specify a requested shaping rate. A non-zero value in
parameter 5 overrides the value in parameter 1 and is used as the
peak cell rate in calculations of CAC and shaping rate.
For trafficDescType 3 the traffic is shaped at the next rate less than
the PCR.
For trafficDescType 6, 7, and 8, the traffic is shaped at the highest
available rate which is between PCR and SCR. However, if there is
no available shaping rate between PCR and SCR, traffic is shaped at
the next rate above the PCR."
::= { atmIfVptIispSigVcd 387 }
atmIfVptIispSigVcdTdpEntry OBJECT-TYPE
SYNTAX AtmIfVptIispSigVcdTdpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispSigVcdTdpTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispSigIndex,
atmIfVptIispSigVcdIndex,
atmIfVptIispSigVcdTdpIndex }
::= { atmIfVptIispSigVcdTdpTable 1 }
AtmIfVptIispSigVcdTdpEntry ::= SEQUENCE {
atmIfVptIispSigVcdTdpIndex
Integer32,
atmIfVptIispSigVcdTdpValue
Unsigned32 }
atmIfVptIispSigVcdTdpIndex OBJECT-TYPE
SYNTAX Integer32 (1..5)
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the atmIfVptIispSigVcdTdpTable
specific index for the atmIfVptIispSigVcdTdpTable."
::= { atmIfVptIispSigVcdTdpEntry 1 }
atmIfVptIispSigVcdTdpValue OBJECT-TYPE
SYNTAX Unsigned32 (0..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable represents an individual value for the
atmIfVptIispSigVcdTdpTable."
::= { atmIfVptIispSigVcdTdpEntry 2 }
atmIfVptIispAddr OBJECT IDENTIFIER ::= { atmIfVptIisp 4 }
atmIfVptIispAddrRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispAddrRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfVptIispAddr components."
::= { atmIfVptIispAddr 1 }
atmIfVptIispAddrRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfVptIispAddrRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfVptIispAddr component."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispAddrAddressIndex,
atmIfVptIispAddrAddressTypeIndex }
::= { atmIfVptIispAddrRowStatusTable 1 }
AtmIfVptIispAddrRowStatusEntry ::= SEQUENCE {
atmIfVptIispAddrRowStatus
RowStatus,
atmIfVptIispAddrComponentName
DisplayString,
atmIfVptIispAddrStorageType
StorageType,
atmIfVptIispAddrAddressIndex
AsciiStringIndex,
atmIfVptIispAddrAddressTypeIndex
INTEGER }
atmIfVptIispAddrRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfVptIispAddr components.
These components can be added and deleted."
::= { atmIfVptIispAddrRowStatusEntry 1 }
atmIfVptIispAddrComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfVptIispAddrRowStatusEntry 2 }
atmIfVptIispAddrStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfVptIispAddr tables."
::= { atmIfVptIispAddrRowStatusEntry 4 }
atmIfVptIispAddrAddressIndex OBJECT-TYPE
SYNTAX AsciiStringIndex (SIZE (1..40))
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents an index for the atmIfVptIispAddr tables."
::= { atmIfVptIispAddrRowStatusEntry 10 }
atmIfVptIispAddrAddressTypeIndex OBJECT-TYPE
SYNTAX INTEGER {
primary(0),
alternate(1),
default(3) }
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents an index for the atmIfVptIispAddr tables."
::= { atmIfVptIispAddrRowStatusEntry 11 }
atmIfVptIispAddrOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispAddrOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute group contains the operational attributes for the
Address component."
::= { atmIfVptIispAddr 10 }
atmIfVptIispAddrOperEntry OBJECT-TYPE
SYNTAX AtmIfVptIispAddrOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispAddrOperTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispAddrAddressIndex,
atmIfVptIispAddrAddressTypeIndex }
::= { atmIfVptIispAddrOperTable 1 }
AtmIfVptIispAddrOperEntry ::= SEQUENCE {
atmIfVptIispAddrScope
INTEGER,
atmIfVptIispAddrReachability
INTEGER }
atmIfVptIispAddrScope OBJECT-TYPE
SYNTAX INTEGER (-1..104)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the scope of the ATM address, which is the
highest level to which this address will be advertised in the PNNI
hierarchy. If no PnniInfo subcomponent has been provisioned, then
the scope will default to the level of this node in the PNNI
hierarchy. If this node does not participate in a PNNI hierarchy, then
this attribute will have the value of -1."
::= { atmIfVptIispAddrOperEntry 1 }
atmIfVptIispAddrReachability OBJECT-TYPE
SYNTAX INTEGER {
internal(0),
exterior(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates whether the address is internal or exterior.
An internal reachable address is an address of a destination that is
directly attached to the logical node advertising the address. An
exterior reachable address is an address that can be reached
through a PNNI routing domain, but which is not located in that
PNNI routing domain."
::= { atmIfVptIispAddrOperEntry 2 }
atmIfVptIispAddrTermSP OBJECT IDENTIFIER ::= { atmIfVptIispAddr 2 }
atmIfVptIispAddrTermSPRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispAddrTermSPRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfVptIispAddrTermSP components."
::= { atmIfVptIispAddrTermSP 1 }
atmIfVptIispAddrTermSPRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfVptIispAddrTermSPRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfVptIispAddrTermSP component."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispAddrAddressIndex,
atmIfVptIispAddrAddressTypeIndex,
atmIfVptIispAddrTermSPIndex }
::= { atmIfVptIispAddrTermSPRowStatusTable 1 }
AtmIfVptIispAddrTermSPRowStatusEntry ::= SEQUENCE {
atmIfVptIispAddrTermSPRowStatus
RowStatus,
atmIfVptIispAddrTermSPComponentName
DisplayString,
atmIfVptIispAddrTermSPStorageType
StorageType,
atmIfVptIispAddrTermSPIndex
NonReplicated }
atmIfVptIispAddrTermSPRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfVptIispAddrTermSP components.
These components can be added and deleted."
::= { atmIfVptIispAddrTermSPRowStatusEntry 1 }
atmIfVptIispAddrTermSPComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfVptIispAddrTermSPRowStatusEntry 2 }
atmIfVptIispAddrTermSPStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfVptIispAddrTermSP tables."
::= { atmIfVptIispAddrTermSPRowStatusEntry 4 }
atmIfVptIispAddrTermSPIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfVptIispAddrTermSP tables."
::= { atmIfVptIispAddrTermSPRowStatusEntry 10 }
atmIfVptIispAddrPnniInfo OBJECT IDENTIFIER ::= { atmIfVptIispAddr 3 }
atmIfVptIispAddrPnniInfoRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispAddrPnniInfoRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
atmIfVptIispAddrPnniInfo components."
::= { atmIfVptIispAddrPnniInfo 1 }
atmIfVptIispAddrPnniInfoRowStatusEntry OBJECT-TYPE
SYNTAX AtmIfVptIispAddrPnniInfoRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
atmIfVptIispAddrPnniInfo component."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispAddrAddressIndex,
atmIfVptIispAddrAddressTypeIndex,
atmIfVptIispAddrPnniInfoIndex }
::= { atmIfVptIispAddrPnniInfoRowStatusTable 1 }
AtmIfVptIispAddrPnniInfoRowStatusEntry ::= SEQUENCE {
atmIfVptIispAddrPnniInfoRowStatus
RowStatus,
atmIfVptIispAddrPnniInfoComponentName
DisplayString,
atmIfVptIispAddrPnniInfoStorageType
StorageType,
atmIfVptIispAddrPnniInfoIndex
NonReplicated }
atmIfVptIispAddrPnniInfoRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
atmIfVptIispAddrPnniInfo components.
These components can be added and deleted."
::= { atmIfVptIispAddrPnniInfoRowStatusEntry 1 }
atmIfVptIispAddrPnniInfoComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { atmIfVptIispAddrPnniInfoRowStatusEntry 2 }
atmIfVptIispAddrPnniInfoStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
atmIfVptIispAddrPnniInfo tables."
::= { atmIfVptIispAddrPnniInfoRowStatusEntry 4 }
atmIfVptIispAddrPnniInfoIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the atmIfVptIispAddrPnniInfo tables."
::= { atmIfVptIispAddrPnniInfoRowStatusEntry 10 }
atmIfVptIispAddrPnniInfoProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF AtmIfVptIispAddrPnniInfoProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This attribute group contains the provisioned attributes relating to
PNNI for a PnniInfo component."
::= { atmIfVptIispAddrPnniInfo 10 }
atmIfVptIispAddrPnniInfoProvEntry OBJECT-TYPE
SYNTAX AtmIfVptIispAddrPnniInfoProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the atmIfVptIispAddrPnniInfoProvTable."
INDEX {
atmIfIndex,
atmIfVptIndex,
atmIfVptIispIndex,
atmIfVptIispAddrAddressIndex,
atmIfVptIispAddrAddressTypeIndex,
atmIfVptIispAddrPnniInfoIndex }
::= { atmIfVptIispAddrPnniInfoProvTable 1 }
AtmIfVptIispAddrPnniInfoProvEntry ::= SEQUENCE {
atmIfVptIispAddrPnniInfoScope
INTEGER,
atmIfVptIispAddrPnniInfoReachability
INTEGER }
atmIfVptIispAddrPnniInfoScope OBJECT-TYPE
SYNTAX INTEGER (-1..104)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the scope of the ATM address, which is the
highest level up to which this address will be advertised in the
PNNI hierarchy. The scope must be set to a value numerically less
than or equal to the level of the lowest level peer group containing
this node. Setting the scope to 0 will cause the address to be
advertised globally within this PNNI routing domain."
DEFVAL { -1 }
::= { atmIfVptIispAddrPnniInfoProvEntry 1 }
atmIfVptIispAddrPnniInfoReachability OBJECT-TYPE
SYNTAX INTEGER {
internal(0),
exterior(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute indicates whether the address is internal or exterior.
An internal reachable address is an address of a destination that is
directly attached to the logical node advertising the address. An
exterior reachable address is an address that can be reached
through a PNNI routing domain, but which is not located in that
PNNI routing domain."
DEFVAL { internal }
::= { atmIfVptIispAddrPnniInfoProvEntry 2 }
atmIispGroup OBJECT IDENTIFIER ::= { atmIispMIB 1 }
atmIispGroupBE OBJECT IDENTIFIER ::= { atmIispGroup 5 }
atmIispGroupBE00 OBJECT IDENTIFIER ::= { atmIispGroupBE 1 }
atmIispGroupBE00A OBJECT IDENTIFIER ::= { atmIispGroupBE00 2 }
atmIispCapabilities OBJECT IDENTIFIER ::= { atmIispMIB 3 }
atmIispCapabilitiesBE OBJECT IDENTIFIER ::= { atmIispCapabilities 5 }
atmIispCapabilitiesBE00 OBJECT IDENTIFIER ::= { atmIispCapabilitiesBE 1 }
atmIispCapabilitiesBE00A OBJECT IDENTIFIER ::= { atmIispCapabilitiesBE00 2 }
END