Nortel-Magellan-Passport-VnetEuroIsdnMIB
DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
passportMIBs
FROM Nortel-Magellan-Passport-UsefulDefinitionsMIB
Counter32,
DisplayString,
StorageType,
RowStatus,
Gauge32,
Unsigned32
FROM Nortel-Magellan-Passport-StandardTextualConventionsMIB
NonReplicated,
Link
FROM Nortel-Magellan-Passport-TextualConventionsMIB
sigChanIndex,
sigChan
FROM Nortel-Magellan-Passport-VoiceNetworkingMIB;
vnetEuroIsdnMIB OBJECT IDENTIFIER ::= { passportMIBs 138 }
sigChanEIsdn OBJECT IDENTIFIER ::= { sigChan 14 }
sigChanEIsdnRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
sigChanEIsdn components."
::= { sigChanEIsdn 1 }
sigChanEIsdnRowStatusEntry OBJECT-TYPE
SYNTAX SigChanEIsdnRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
sigChanEIsdn component."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnRowStatusTable 1 }
SigChanEIsdnRowStatusEntry ::= SEQUENCE {
sigChanEIsdnRowStatus
RowStatus,
sigChanEIsdnComponentName
DisplayString,
sigChanEIsdnStorageType
StorageType,
sigChanEIsdnIndex
NonReplicated }
sigChanEIsdnRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
sigChanEIsdn components.
These components can be added and deleted."
::= { sigChanEIsdnRowStatusEntry 1 }
sigChanEIsdnComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { sigChanEIsdnRowStatusEntry 2 }
sigChanEIsdnStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
sigChanEIsdn tables."
::= { sigChanEIsdnRowStatusEntry 4 }
sigChanEIsdnIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the sigChanEIsdn tables."
::= { sigChanEIsdnRowStatusEntry 10 }
sigChanEIsdnL2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnL2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group specifies the provisionable layer 2 attributes of the Euro
ISDN (ETSI-T) protocol."
::= { sigChanEIsdn 11 }
sigChanEIsdnL2Entry OBJECT-TYPE
SYNTAX SigChanEIsdnL2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnL2Table."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnL2Table 1 }
SigChanEIsdnL2Entry ::= SEQUENCE {
sigChanEIsdnT23
Unsigned32,
sigChanEIsdnT200
Unsigned32,
sigChanEIsdnN200
Unsigned32,
sigChanEIsdnT203
Unsigned32,
sigChanEIsdnCircuitSwitchedK
Unsigned32 }
sigChanEIsdnT23 OBJECT-TYPE
SYNTAX Unsigned32 (1..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies duration of the layer 2 enable request timer."
DEFVAL { 10 }
::= { sigChanEIsdnL2Entry 1 }
sigChanEIsdnT200 OBJECT-TYPE
SYNTAX Unsigned32 (1..20)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum elapsed time between a layer
2 frame and its acknowledgment."
DEFVAL { 1 }
::= { sigChanEIsdnL2Entry 2 }
sigChanEIsdnN200 OBJECT-TYPE
SYNTAX Unsigned32 (1..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum number of re-transmissions of
a layer 2 frame."
DEFVAL { 3 }
::= { sigChanEIsdnL2Entry 3 }
sigChanEIsdnT203 OBJECT-TYPE
SYNTAX Unsigned32 (2..40)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum time during which layer 2
frames may be absent. Expiry triggers a check on whether the far
end is alive."
DEFVAL { 10 }
::= { sigChanEIsdnL2Entry 4 }
sigChanEIsdnCircuitSwitchedK OBJECT-TYPE
SYNTAX Unsigned32 (1..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum number of sequentially
numbered I frames (that is, window size (k)) that may be
unacknowledged at any given time for a SAP supporting primary
rate (64kbit/sec) signalling."
DEFVAL { 7 }
::= { sigChanEIsdnL2Entry 6 }
sigChanEIsdnL3Table OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnL3Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group represents the provisionable Layer 3 timer attributes of a
the Euro ISDN (ETSI-T) protocol."
::= { sigChanEIsdn 12 }
sigChanEIsdnL3Entry OBJECT-TYPE
SYNTAX SigChanEIsdnL3Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnL3Table."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnL3Table 1 }
SigChanEIsdnL3Entry ::= SEQUENCE {
sigChanEIsdnT310
Unsigned32 }
sigChanEIsdnT310 OBJECT-TYPE
SYNTAX Unsigned32 (10..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies duration of the call proceeding state timer."
DEFVAL { 30 }
::= { sigChanEIsdnL3Entry 4 }
sigChanEIsdnProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group defines the general options of the D-channel signalling
link."
::= { sigChanEIsdn 13 }
sigChanEIsdnProvEntry OBJECT-TYPE
SYNTAX SigChanEIsdnProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnProvTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnProvTable 1 }
SigChanEIsdnProvEntry ::= SEQUENCE {
sigChanEIsdnSide
INTEGER,
sigChanEIsdnMaxNonCallConcurrent
Unsigned32,
sigChanEIsdnOverlapSending
INTEGER,
sigChanEIsdnOverlapReceiving
INTEGER }
sigChanEIsdnSide OBJECT-TYPE
SYNTAX INTEGER {
network(1),
user(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether the interface is the network or user
side of the connection. The parameter applies to both the layer 2
and layer 3 of the interface. In addition, if this attribute is set to
network, then the interface is master during channel negotiation. If
this attribute is set to user, then the interface is slave during channel
negotiation."
DEFVAL { network }
::= { sigChanEIsdnProvEntry 1 }
sigChanEIsdnMaxNonCallConcurrent OBJECT-TYPE
SYNTAX Unsigned32 (0..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum number of simultaneous active
non call-associated sessions that are allowed. Reduction of the value
does not impact NCAS sessions already in progress."
DEFVAL { 30 }
::= { sigChanEIsdnProvEntry 2 }
sigChanEIsdnOverlapSending OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
disabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether overlap sending to the PBX is
enabled."
DEFVAL { enabled }
::= { sigChanEIsdnProvEntry 3 }
sigChanEIsdnOverlapReceiving OBJECT-TYPE
SYNTAX INTEGER {
enabled(0),
disabled(1) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether overlap receiving from the PBX is
enabled."
DEFVAL { enabled }
::= { sigChanEIsdnProvEntry 4 }
sigChanEIsdnStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the three OSI State attributes. The descriptions
generically indicate what each state attribute implies about the
component. Note that not all the values and state combinations
described here are supported by every component which uses this
group. For component-specific information and the valid state
combinations, refer to NTP 241-7001-150, Passport Operations and
Maintenance Guide."
::= { sigChanEIsdn 14 }
sigChanEIsdnStateEntry OBJECT-TYPE
SYNTAX SigChanEIsdnStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnStateTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnStateTable 1 }
SigChanEIsdnStateEntry ::= SEQUENCE {
sigChanEIsdnAdminState
INTEGER,
sigChanEIsdnOperationalState
INTEGER,
sigChanEIsdnUsageState
INTEGER }
sigChanEIsdnAdminState OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
unlocked(1),
shuttingDown(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component."
DEFVAL { unlocked }
::= { sigChanEIsdnStateEntry 1 }
sigChanEIsdnOperationalState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle."
DEFVAL { disabled }
::= { sigChanEIsdnStateEntry 2 }
sigChanEIsdnUsageState OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
active(1),
busy(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time."
DEFVAL { idle }
::= { sigChanEIsdnStateEntry 3 }
sigChanEIsdnStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group provides the statistical attributes for the SigChan/x
EuroIsdn component."
::= { sigChanEIsdn 15 }
sigChanEIsdnStatsEntry OBJECT-TYPE
SYNTAX SigChanEIsdnStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnStatsTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnStatsTable 1 }
SigChanEIsdnStatsEntry ::= SEQUENCE {
sigChanEIsdnTotalCallsToIf
Counter32,
sigChanEIsdnTotalCallsFromIf
Counter32,
sigChanEIsdnNonCallAssocSessionsToIf
Counter32,
sigChanEIsdnNonCallAssocSessionsFromIf
Counter32 }
sigChanEIsdnTotalCallsToIf OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of calls that have been made
to the interface. The value wraps to zero when it exceeds its
maximum."
::= { sigChanEIsdnStatsEntry 2 }
sigChanEIsdnTotalCallsFromIf OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of calls that have been made
from the interface. The value wraps to zero when it exceeds its
maximum."
::= { sigChanEIsdnStatsEntry 3 }
sigChanEIsdnNonCallAssocSessionsToIf OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of non call-associated
sessions that have been made to the interface. The value wraps to
zero when it exceeds its maximum."
::= { sigChanEIsdnStatsEntry 4 }
sigChanEIsdnNonCallAssocSessionsFromIf OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of non call-associated
sessions that have been made from the interface. The value wraps to
zero when it exceeds its maximum."
::= { sigChanEIsdnStatsEntry 5 }
sigChanEIsdnOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group provides the operational attributes for the SigChan/x
EuroIsdn component."
::= { sigChanEIsdn 16 }
sigChanEIsdnOperEntry OBJECT-TYPE
SYNTAX SigChanEIsdnOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnOperTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnOperTable 1 }
SigChanEIsdnOperEntry ::= SEQUENCE {
sigChanEIsdnActiveChannels
Gauge32,
sigChanEIsdnActiveVoiceChannels
Gauge32,
sigChanEIsdnActiveDataChannels
Gauge32,
sigChanEIsdnPeakActiveChannels
Gauge32,
sigChanEIsdnPeakActiveVoiceChannels
Gauge32,
sigChanEIsdnPeakActiveDataChannels
Gauge32,
sigChanEIsdnDChanStatus
INTEGER }
sigChanEIsdnActiveChannels OBJECT-TYPE
SYNTAX Gauge32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the number of currently active channels.
This includes channels used by both, data and voice calls."
DEFVAL { 0 }
::= { sigChanEIsdnOperEntry 1 }
sigChanEIsdnActiveVoiceChannels OBJECT-TYPE
SYNTAX Gauge32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the number of channels that are currently
used by voice calls. This includes modem calls."
DEFVAL { 0 }
::= { sigChanEIsdnOperEntry 2 }
sigChanEIsdnActiveDataChannels OBJECT-TYPE
SYNTAX Gauge32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the number of channels that are currently
used by data calls. This does not include modem data."
DEFVAL { 0 }
::= { sigChanEIsdnOperEntry 3 }
sigChanEIsdnPeakActiveChannels OBJECT-TYPE
SYNTAX Gauge32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the maximum value of the activeChannels
attribute during the last polling period."
DEFVAL { 0 }
::= { sigChanEIsdnOperEntry 4 }
sigChanEIsdnPeakActiveVoiceChannels OBJECT-TYPE
SYNTAX Gauge32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the maximum value of the
activeVoiceChannels attribute during the last polling period."
DEFVAL { 0 }
::= { sigChanEIsdnOperEntry 5 }
sigChanEIsdnPeakActiveDataChannels OBJECT-TYPE
SYNTAX Gauge32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the maximum value of the
activeDataChannels attribute during the last polling period."
DEFVAL { 0 }
::= { sigChanEIsdnOperEntry 6 }
sigChanEIsdnDChanStatus OBJECT-TYPE
SYNTAX INTEGER {
outOfService(0),
establishing(1),
established(2),
enabling(3),
inService(4),
restarting(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the state of the D-channel.
outOfService means that there is no layer 2 or layer 3 connectivity
to the PBX.
establishing means that the signalling channel is attempting to stage
the layer 2.
established means that the layer 2 is enabled. If the signalling
channel stays in the established state, then it is waiting for a restart
from the PBX.
enabling means that the resources for processing calls are being
initialized. If the signalling channel stays in the enabling state then
it is waiting for a restart acknowledgment from the PBX.
inService means that the resources for processing calls are
available.
restarting means that the resources for call processing are being
initialized."
::= { sigChanEIsdnOperEntry 7 }
sigChanEIsdnToolsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnToolsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This contains a series of operational attributes which turn on and off
several kinds of tracing."
::= { sigChanEIsdn 17 }
sigChanEIsdnToolsEntry OBJECT-TYPE
SYNTAX SigChanEIsdnToolsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnToolsTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnToolsTable 1 }
SigChanEIsdnToolsEntry ::= SEQUENCE {
sigChanEIsdnTracing
OCTET STRING }
sigChanEIsdnTracing OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute defines which types of tracing are active on the
signalling channel. The tracing messages are sent to the debug
stream. To see the messages the agentQueueSize attribute of the
Lp/x Eng Ds/debug component must be greater than 0 and the
operator's NMIS session must have the debug stream included in its
data stream list (for example: set Nmis Telnet Session/1
dataStreams deb). Several types of tracing can be enabled
simultaneously.
Note that tracing consumes additional CPU resources and slows
down call processing on a heavily loaded card. If there is message
block exhaustion tracing is suspended for a period of time and then
automatically re-enabled. An alarm is generated on tracing
suspension and resumption. This mechanism protects the function
processor against excessive numbers of tracing messages.
Types of tracing include:
protocolErrors - get details of any protocol errors which are
occurring. Protocol errors are also reported in summary form as
alarms.
q931Summary - summary of the Q.931 messages on the signalling
link.
q931Hex - Q.931 messages displayed in hex format. Useful to
determine protocol compliance in case of errors reported on local or
remote ends.
q931Symbolic - Q.931 messages parsed to give maximum detail.
Useful for understanding content of messages flowing on the link.
portHex - Q.921 messages in hex format being sent and received on
the link.
Description of bits:
protocolErrors(0)
q931Summary(1)
q931Hex(2)
q931Symbolic(3)
portHex(4)"
::= { sigChanEIsdnToolsEntry 1 }
sigChanEIsdnOptTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnOptEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group specifies the provisionable attributes specific to the Euro
ISDN (ETSI-T) protocol."
::= { sigChanEIsdn 18 }
sigChanEIsdnOptEntry OBJECT-TYPE
SYNTAX SigChanEIsdnOptEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnOptTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex }
::= { sigChanEIsdnOptTable 1 }
SigChanEIsdnOptEntry ::= SEQUENCE {
sigChanEIsdnVariant
INTEGER,
sigChanEIsdnConnectServiceTimer
Unsigned32,
sigChanEIsdnResponseServiceTimer
Unsigned32,
sigChanEIsdnLifetimeServiceTimer
Unsigned32 }
sigChanEIsdnVariant OBJECT-TYPE
SYNTAX INTEGER {
etsiGeneric(0),
austria(1),
germany(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the specific variant of the Euro ISDN (ETSI-
T) protocol. Supported variants are:
etsiGeneric - provides generic ETSI-T protocol. Only proxy of the
NETWORK side of the protocol is implemented,
austria - provides ETSI-T protocol variant as per the Austrian
national specification. Only the USER side of the protocol is
implemented,
germany - provides ETSI-T protocol variant as per the German
national specification. Only the USER side of the protocol is
implemented."
DEFVAL { etsiGeneric }
::= { sigChanEIsdnOptEntry 1 }
sigChanEIsdnConnectServiceTimer OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies duration of the 'await connection'
supervisory timer which applies to non call-associated sessions
providing bearer-independent connection-oriented transport for
supplementary services. The timer is started at the ingress Passport
when a REGISTER message is received from the source PBX and
stopped when a virtual circuit with the egress Passport is
established. If the timer expires, the non call-associated session is
cleared.
The 'await connection' timer (attribute connectServiceTimer)
together with 'await response' timer (attribute
responseServiceTimer) provide equivalent of the T-ACTIVATE
timer described in the relevant supplementary service specifications.
A change of the timer value does not apply to timers already
running."
DEFVAL { 8 }
::= { sigChanEIsdnOptEntry 2 }
sigChanEIsdnResponseServiceTimer OBJECT-TYPE
SYNTAX Unsigned32 (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies duration of the 'await response' supervisory
timer which applies to non call-associated sessions providing
bearer-independent connection-oriented transport for supplementary
services. The timer is started at the ingress Passport when creation
of a virtual circuit with the egress Passport is confirmed and stopped
when the first message from the destination PBX is received. If the
timer expires, the non call-associated session is cleared.
The 'await connection' timer (attribute connectServiceTimer)
together with 'await response' timer (attribute
responseServiceTimer) provide equivalent of the T-ACTIVATE
timer described in the relevant supplementary service specifications.
A change of the timer value does not apply to timers already
running."
DEFVAL { 8 }
::= { sigChanEIsdnOptEntry 3 }
sigChanEIsdnLifetimeServiceTimer OBJECT-TYPE
SYNTAX Unsigned32 (1..200)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies duration of the service lifetime supervisory
timer which applies to non call-associated sessions providing
bearer-independent connection-oriented transport for supplementary
services. The timer limits the duration of a virtual call. It is started
at the ingress Passport at the moment the first response message
from the destination PBX has been received and stopped when the
non call-associated session is released. If the timer expires, the non
call-associated session is cleared.
This timer is equivalent to the T-CCBS6 timer described in the
relevant supplementary service specifications.
A change of the timer value does not apply to timers already
running."
DEFVAL { 60 }
::= { sigChanEIsdnOptEntry 4 }
sigChanEIsdnFramer OBJECT IDENTIFIER ::= { sigChanEIsdn 2 }
sigChanEIsdnFramerRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnFramerRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
sigChanEIsdnFramer components."
::= { sigChanEIsdnFramer 1 }
sigChanEIsdnFramerRowStatusEntry OBJECT-TYPE
SYNTAX SigChanEIsdnFramerRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
sigChanEIsdnFramer component."
INDEX {
sigChanIndex,
sigChanEIsdnIndex,
sigChanEIsdnFramerIndex }
::= { sigChanEIsdnFramerRowStatusTable 1 }
SigChanEIsdnFramerRowStatusEntry ::= SEQUENCE {
sigChanEIsdnFramerRowStatus
RowStatus,
sigChanEIsdnFramerComponentName
DisplayString,
sigChanEIsdnFramerStorageType
StorageType,
sigChanEIsdnFramerIndex
NonReplicated }
sigChanEIsdnFramerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
sigChanEIsdnFramer components.
These components cannot be added nor deleted."
::= { sigChanEIsdnFramerRowStatusEntry 1 }
sigChanEIsdnFramerComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { sigChanEIsdnFramerRowStatusEntry 2 }
sigChanEIsdnFramerStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
sigChanEIsdnFramer tables."
::= { sigChanEIsdnFramerRowStatusEntry 4 }
sigChanEIsdnFramerIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the sigChanEIsdnFramer tables."
::= { sigChanEIsdnFramerRowStatusEntry 10 }
sigChanEIsdnFramerProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnFramerProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the base provisioning data for the Framer
component. Application or hardware interface specific provisioning
data is contained in other provisionable Framer groups."
::= { sigChanEIsdnFramer 10 }
sigChanEIsdnFramerProvEntry OBJECT-TYPE
SYNTAX SigChanEIsdnFramerProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnFramerProvTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex,
sigChanEIsdnFramerIndex }
::= { sigChanEIsdnFramerProvTable 1 }
SigChanEIsdnFramerProvEntry ::= SEQUENCE {
sigChanEIsdnFramerInterfaceName
Link }
sigChanEIsdnFramerInterfaceName OBJECT-TYPE
SYNTAX Link
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute contains a hardware component name.
The attribute associates the application with a specific link. This
defines the module processor on which Framer's parent component
(as well as Framer itself) will run."
::= { sigChanEIsdnFramerProvEntry 1 }
sigChanEIsdnFramerStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnFramerStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the three OSI State attributes. The descriptions
generically indicate what each state attribute implies about the
component. Note that not all the values and state combinations
described here are supported by every component which uses this
group. For component-specific information and the valid state
combinations, refer to NTP 241-7001-150, Passport Operations and
Maintenance Guide."
::= { sigChanEIsdnFramer 12 }
sigChanEIsdnFramerStateEntry OBJECT-TYPE
SYNTAX SigChanEIsdnFramerStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnFramerStateTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex,
sigChanEIsdnFramerIndex }
::= { sigChanEIsdnFramerStateTable 1 }
SigChanEIsdnFramerStateEntry ::= SEQUENCE {
sigChanEIsdnFramerAdminState
INTEGER,
sigChanEIsdnFramerOperationalState
INTEGER,
sigChanEIsdnFramerUsageState
INTEGER }
sigChanEIsdnFramerAdminState OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
unlocked(1),
shuttingDown(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component."
DEFVAL { unlocked }
::= { sigChanEIsdnFramerStateEntry 1 }
sigChanEIsdnFramerOperationalState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle."
DEFVAL { disabled }
::= { sigChanEIsdnFramerStateEntry 2 }
sigChanEIsdnFramerUsageState OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
active(1),
busy(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time."
DEFVAL { idle }
::= { sigChanEIsdnFramerStateEntry 3 }
sigChanEIsdnFramerStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanEIsdnFramerStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the operational statistics data for a Framer
component."
::= { sigChanEIsdnFramer 13 }
sigChanEIsdnFramerStatsEntry OBJECT-TYPE
SYNTAX SigChanEIsdnFramerStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanEIsdnFramerStatsTable."
INDEX {
sigChanIndex,
sigChanEIsdnIndex,
sigChanEIsdnFramerIndex }
::= { sigChanEIsdnFramerStatsTable 1 }
SigChanEIsdnFramerStatsEntry ::= SEQUENCE {
sigChanEIsdnFramerFrmToIf
Counter32,
sigChanEIsdnFramerFrmFromIf
Counter32,
sigChanEIsdnFramerOctetFromIf
Counter32,
sigChanEIsdnFramerAborts
Counter32,
sigChanEIsdnFramerCrcErrors
Counter32,
sigChanEIsdnFramerLrcErrors
Counter32,
sigChanEIsdnFramerNonOctetErrors
Counter32,
sigChanEIsdnFramerOverruns
Counter32,
sigChanEIsdnFramerUnderruns
Counter32,
sigChanEIsdnFramerLargeFrmErrors
Counter32 }
sigChanEIsdnFramerFrmToIf OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of frames transmitted to the link
interface by the Framer.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 1 }
sigChanEIsdnFramerFrmFromIf OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of frames received from the link
interface by the Framer.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 2 }
sigChanEIsdnFramerOctetFromIf OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of bytes received from the link
interface by the Framer.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 3 }
sigChanEIsdnFramerAborts OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of aborts received.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 4 }
sigChanEIsdnFramerCrcErrors OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames with CRC errors.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 5 }
sigChanEIsdnFramerLrcErrors OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames with LRC errors.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 6 }
sigChanEIsdnFramerNonOctetErrors OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames that were non octet
aligned.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 7 }
sigChanEIsdnFramerOverruns OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames received from the
link for which overruns occurred.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 8 }
sigChanEIsdnFramerUnderruns OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames transmitted to the
link for which underruns occurred.
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 9 }
sigChanEIsdnFramerLargeFrmErrors OBJECT-TYPE
SYNTAX Counter32
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames received which
were too large (longer than 500 bytes).
This count wraps to zero after exceeding its maximum value."
::= { sigChanEIsdnFramerStatsEntry 10 }
vnetEuroIsdnGroup OBJECT IDENTIFIER ::= { vnetEuroIsdnMIB 1 }
vnetEuroIsdnGroupBE OBJECT IDENTIFIER ::= { vnetEuroIsdnGroup 5 }
vnetEuroIsdnGroupBE01 OBJECT IDENTIFIER ::= { vnetEuroIsdnGroupBE 2 }
vnetEuroIsdnGroupBE01A OBJECT IDENTIFIER ::= { vnetEuroIsdnGroupBE01 2 }
vnetEuroIsdnCapabilities OBJECT IDENTIFIER ::= { vnetEuroIsdnMIB 3 }
vnetEuroIsdnCapabilitiesBE OBJECT IDENTIFIER ::= { vnetEuroIsdnCapabilities 5 }
vnetEuroIsdnCapabilitiesBE01 OBJECT IDENTIFIER ::= { vnetEuroIsdnCapabilitiesBE 2 }
vnetEuroIsdnCapabilitiesBE01A OBJECT IDENTIFIER ::= { vnetEuroIsdnCapabilitiesBE01 2 }
END