Nortel-Magellan-Passport-VnetNisSigMIB
DEFINITIONS ::= BEGIN
IMPORTS
OBJECT-TYPE
FROM RFC-1212
passportMIBs
FROM Nortel-Magellan-Passport-UsefulDefinitionsMIB
DisplayString,
StorageType,
RowStatus,
Unsigned32
FROM Nortel-Magellan-Passport-StandardTextualConventionsMIB
NonReplicated,
Link
FROM Nortel-Magellan-Passport-TextualConventionsMIB
sigChanIndex,
sigChan
FROM Nortel-Magellan-Passport-VoiceNetworkingMIB;
vnetNisSigMIB OBJECT IDENTIFIER ::= { passportMIBs 112 }
sigChanNis OBJECT IDENTIFIER ::= { sigChan 8 }
sigChanNisRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
sigChanNis components."
::= { sigChanNis 1 }
sigChanNisRowStatusEntry OBJECT-TYPE
SYNTAX SigChanNisRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
sigChanNis component."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisRowStatusTable 1 }
SigChanNisRowStatusEntry ::= SEQUENCE {
sigChanNisRowStatus
RowStatus,
sigChanNisComponentName
DisplayString,
sigChanNisStorageType
StorageType,
sigChanNisIndex
NonReplicated }
sigChanNisRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
sigChanNis components.
These components can be added and deleted."
::= { sigChanNisRowStatusEntry 1 }
sigChanNisComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { sigChanNisRowStatusEntry 2 }
sigChanNisStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
sigChanNis tables."
::= { sigChanNisRowStatusEntry 4 }
sigChanNisIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the sigChanNis tables."
::= { sigChanNisRowStatusEntry 10 }
sigChanNisL2Table OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisL2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group specifies the provisionable layer 2 attributes of the
Q.931 ITU-T protocol."
::= { sigChanNis 11 }
sigChanNisL2Entry OBJECT-TYPE
SYNTAX SigChanNisL2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisL2Table."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisL2Table 1 }
SigChanNisL2Entry ::= SEQUENCE {
sigChanNisT23
Unsigned32,
sigChanNisT200
Unsigned32,
sigChanNisN200
Unsigned32,
sigChanNisT203
Unsigned32,
sigChanNisCircuitSwitchedK
Unsigned32 }
sigChanNisT23 OBJECT-TYPE
SYNTAX Unsigned32 (1..15)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the layer 2 enable request timer."
DEFVAL { 10 }
::= { sigChanNisL2Entry 1 }
sigChanNisT200 OBJECT-TYPE
SYNTAX Unsigned32 (1..20)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum time between a layer 2 frame
and its acknowledgment."
DEFVAL { 1 }
::= { sigChanNisL2Entry 2 }
sigChanNisN200 OBJECT-TYPE
SYNTAX Unsigned32 (1..8)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum number of re-transmissions of
a layer 2 frame."
DEFVAL { 3 }
::= { sigChanNisL2Entry 3 }
sigChanNisT203 OBJECT-TYPE
SYNTAX Unsigned32 (2..40)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum time for which layer 2 frames
may be absent. Expiry triggers a check on whether the far end is
alive."
DEFVAL { 10 }
::= { sigChanNisL2Entry 4 }
sigChanNisCircuitSwitchedK OBJECT-TYPE
SYNTAX Unsigned32 (1..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum number of sequentially
numbered I frames (that is, window size (k)) that may be
unacknowledged at any given time for a SAP supporting primary
rate (64kbit/sec) signalling."
DEFVAL { 7 }
::= { sigChanNisL2Entry 6 }
sigChanNisL3Table OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisL3Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group represents the provisionable Layer 3 timer attributes of a
the Nis signalling protocol."
::= { sigChanNis 12 }
sigChanNisL3Entry OBJECT-TYPE
SYNTAX SigChanNisL3Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisL3Table."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisL3Table 1 }
SigChanNisL3Entry ::= SEQUENCE {
sigChanNisT309
Unsigned32,
sigChanNisT310
Unsigned32 }
sigChanNisT309 OBJECT-TYPE
SYNTAX Unsigned32 (15..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the data link failure timer; used to ride out
temporary failures."
DEFVAL { 90 }
::= { sigChanNisL3Entry 3 }
sigChanNisT310 OBJECT-TYPE
SYNTAX Unsigned32 (10..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the call proceeding state timer."
DEFVAL { 10 }
::= { sigChanNisL3Entry 4 }
sigChanNisProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group defines the general options of the D-channel signalling
link."
::= { sigChanNis 13 }
sigChanNisProvEntry OBJECT-TYPE
SYNTAX SigChanNisProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisProvTable."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisProvTable 1 }
SigChanNisProvEntry ::= SEQUENCE {
sigChanNisSide
INTEGER,
sigChanNisMaxNonCallConcurrent
Unsigned32 }
sigChanNisSide OBJECT-TYPE
SYNTAX INTEGER {
network(1),
user(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies whether the interface is the network or user
side of the connection. The parameter applies to both the layer 2
and layer 3 of the interface. If this attribute is set to network, then
the interface is master during channel negotiation. If this attribute is
set to user, then the interface is slave during channel negotiation."
DEFVAL { network }
::= { sigChanNisProvEntry 1 }
sigChanNisMaxNonCallConcurrent OBJECT-TYPE
SYNTAX Unsigned32 (1..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies the maximum number of simultaneous active
non-call messages that are allowed."
DEFVAL { 30 }
::= { sigChanNisProvEntry 2 }
sigChanNisStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the three OSI State attributes. The descriptions
generically indicate what each state attribute implies about the
component. Note that not all the values and state combinations
described here are supported by every component which uses this
group. For component-specific information and the valid state
combinations, refer to NTP 241-7001-150, Passport Operations and
Maintenance Guide."
::= { sigChanNis 14 }
sigChanNisStateEntry OBJECT-TYPE
SYNTAX SigChanNisStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisStateTable."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisStateTable 1 }
SigChanNisStateEntry ::= SEQUENCE {
sigChanNisAdminState
INTEGER,
sigChanNisOperationalState
INTEGER,
sigChanNisUsageState
INTEGER }
sigChanNisAdminState OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
unlocked(1),
shuttingDown(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component."
DEFVAL { unlocked }
::= { sigChanNisStateEntry 1 }
sigChanNisOperationalState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle."
DEFVAL { disabled }
::= { sigChanNisStateEntry 2 }
sigChanNisUsageState OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
active(1),
busy(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time."
DEFVAL { idle }
::= { sigChanNisStateEntry 3 }
sigChanNisStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group provides the operational components for the NisSig
component."
::= { sigChanNis 15 }
sigChanNisStatsEntry OBJECT-TYPE
SYNTAX SigChanNisStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisStatsTable."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisStatsTable 1 }
SigChanNisStatsEntry ::= SEQUENCE {
sigChanNisTotalCallsToIf
Unsigned32,
sigChanNisTotalCallsFromIf
Unsigned32,
sigChanNisNonCallAssocSessionsToIf
Unsigned32,
sigChanNisNonCallAssocSessionsFromIf
Unsigned32 }
sigChanNisTotalCallsToIf OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of calls that have been made
to the interface. The value wraps when it reaches its maximum."
DEFVAL { 0 }
::= { sigChanNisStatsEntry 2 }
sigChanNisTotalCallsFromIf OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of calls from the interface.
The value wraps when it reaches its maximum."
DEFVAL { 0 }
::= { sigChanNisStatsEntry 3 }
sigChanNisNonCallAssocSessionsToIf OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of non-call associated
sessions to the interface. The value wraps when it reaches its
maximum."
DEFVAL { 0 }
::= { sigChanNisStatsEntry 4 }
sigChanNisNonCallAssocSessionsFromIf OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of non-call associated
sessions from the interface. The value wraps when it reaches its
maximum."
DEFVAL { 0 }
::= { sigChanNisStatsEntry 5 }
sigChanNisOperTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group provides the operational attributes for the NisSig
protocol."
::= { sigChanNis 16 }
sigChanNisOperEntry OBJECT-TYPE
SYNTAX SigChanNisOperEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisOperTable."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisOperTable 1 }
SigChanNisOperEntry ::= SEQUENCE {
sigChanNisActiveChannels
Unsigned32,
sigChanNisActiveVoiceChannels
Unsigned32,
sigChanNisActiveDataChannels
Unsigned32,
sigChanNisPeakActiveChannels
Unsigned32,
sigChanNisPeakActiveVoiceChannels
Unsigned32,
sigChanNisPeakActiveDataChannels
Unsigned32,
sigChanNisDChanStatus
INTEGER }
sigChanNisActiveChannels OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the number of currently active channels.
This includes data and voice channels."
DEFVAL { 0 }
::= { sigChanNisOperEntry 1 }
sigChanNisActiveVoiceChannels OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the number of channels that are currently
carrying voice."
DEFVAL { 0 }
::= { sigChanNisOperEntry 2 }
sigChanNisActiveDataChannels OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the number of channels that are currently
carrying data. This does not include modem data."
DEFVAL { 0 }
::= { sigChanNisOperEntry 3 }
sigChanNisPeakActiveChannels OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the maximum number of channels that have
been active on this signalling channel during the last polling period."
DEFVAL { 0 }
::= { sigChanNisOperEntry 4 }
sigChanNisPeakActiveVoiceChannels OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the maximum number of voice channels that
have been active on this signalling channel during the last polling
period."
DEFVAL { 0 }
::= { sigChanNisOperEntry 5 }
sigChanNisPeakActiveDataChannels OBJECT-TYPE
SYNTAX Unsigned32 (0..128)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the maximum number of data channels that
have been active on this signalling channel during the last polling
period."
DEFVAL { 0 }
::= { sigChanNisOperEntry 6 }
sigChanNisDChanStatus OBJECT-TYPE
SYNTAX INTEGER {
outOfService(0),
establishing(1),
established(2),
enabling(3),
inService(4),
restarting(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the state of the D-channel.
outOfService means that there is no layer 2 or layer 3 connectivity
to the PBX.
establishing means that the signalling channel is attempting to stage
the layer 2.
established means that the layer 2 is enabled. If the signalling
channel stays in the established state, then it is waiting for a restart
from the PBX.
enabling means that the resources for processing calls are being
initialized. If the signalling channel stays in the enabling state then
it is waiting for a restart acknowledgement from the PBX.
inService means that the resources for processing calls are
available.
restarting means that the resources for call processing are being
rei-initialized."
::= { sigChanNisOperEntry 7 }
sigChanNisToolsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisToolsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This contains a series of operational attributes which turn on and off
several kinds of tracing."
::= { sigChanNis 17 }
sigChanNisToolsEntry OBJECT-TYPE
SYNTAX SigChanNisToolsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisToolsTable."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisToolsTable 1 }
SigChanNisToolsEntry ::= SEQUENCE {
sigChanNisTracing
OCTET STRING }
sigChanNisTracing OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (1))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute defines which types of tracing are active for this
signalling channel. The tracing messages are sent to the debug
stream. To see the messages the agentQueue attribute in Col/debug
must be greater than 0 and a Telnet NMIS session must list the
debug stream in in its data streams (ex. set nmis telnet session/1
dataStreams debug). Different types of tracing can be enabled
simultaneously.
Note that tracing consumes additional CPU resources and will slow
down call processing on a heavily loaded card. If there is message
block exhaustion tracing will be suspended for a period and then
automatically reenabled. An alarm is generated on tracing
suspension and resumption. This mechanism protects the function
processor against excessive numbers of tracing messages.
Types of tracing include:
protocolErrors - get details of any protocol errors which are
occuring. Protocol errors are also reported in summary form as
alarms.
q931Summary - Summary of the Q.931 messages on the signalling
link, including certain call details (calling number, called number,
release codes).
q931Hex - Q.931 messages displayed in hex format. Useful to
determine protocol compliance in case of errors reported on local or
remote ends.
q931Symbolic - Q.931 messages parsed to give maximum detail.
Useful for understanding content of messages flowing on the link.
portHex - Messages in hex format being sent and received on the
link.
Description of bits:
protocolErrors(0)
q931Summary(1)
q931Hex(2)
q931Symbolic(3)
portHex(4)"
::= { sigChanNisToolsEntry 1 }
sigChanNisNisSpecificProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisNisSpecificProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group provides NIS protocol specific provisioning."
::= { sigChanNis 18 }
sigChanNisNisSpecificProvEntry OBJECT-TYPE
SYNTAX SigChanNisNisSpecificProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisNisSpecificProvTable."
INDEX {
sigChanIndex,
sigChanNisIndex }
::= { sigChanNisNisSpecificProvTable 1 }
SigChanNisNisSpecificProvEntry ::= SEQUENCE {
sigChanNisChanMaintenanceHandling
INTEGER }
sigChanNisChanMaintenanceHandling OBJECT-TYPE
SYNTAX INTEGER {
globalOnStartup(0),
serviceMessage(1),
restartMessage(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute specifies how channel maintenance events should be
handled upon startup. Channel maintenance events include locking
and unlocking a channel or channel registration. The decision is
either to send individual channel RESTART messages, SERVICE
messages, or nothing. Note that channel registration only occurs
after the global interface restart at startup.
Setting this attribute to enable SERVICE messages ensures that
SERVICE messages occur at startup and whenever a channel goes
into or out of service. If this attribute is not set to enable SERVICE
messaging, a RESTART is always sent on unlocking a channel.
globalOnStartup provides the minimum required functionality at
startup, without any individual channel confirmation. Note that
when this is set, channel RESTART is still used for channel unlock.
globalOnStartup applies to SigChan startup only.
serviceMessage enables sending and receiving SERVICE messages.
If this attribute is set to serviceMessage, SERVICE messages are
used for channel maintenance on channel lock, channel unlock, and
startup.
restartMessage specifies that individual channel RESTARTs when
the SigChan starts up. If this attribute is set to restartMessage, a
RESTART message is used to send at startup and channel unlock."
DEFVAL { restartMessage }
::= { sigChanNisNisSpecificProvEntry 1 }
sigChanNisFramer OBJECT IDENTIFIER ::= { sigChanNis 2 }
sigChanNisFramerRowStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisFramerRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This entry controls the addition and deletion of
sigChanNisFramer components."
::= { sigChanNisFramer 1 }
sigChanNisFramerRowStatusEntry OBJECT-TYPE
SYNTAX SigChanNisFramerRowStatusEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A single entry in the table represents a single
sigChanNisFramer component."
INDEX {
sigChanIndex,
sigChanNisIndex,
sigChanNisFramerIndex }
::= { sigChanNisFramerRowStatusTable 1 }
SigChanNisFramerRowStatusEntry ::= SEQUENCE {
sigChanNisFramerRowStatus
RowStatus,
sigChanNisFramerComponentName
DisplayString,
sigChanNisFramerStorageType
StorageType,
sigChanNisFramerIndex
NonReplicated }
sigChanNisFramerRowStatus OBJECT-TYPE
SYNTAX RowStatus
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable is used as the basis for SNMP naming of
sigChanNisFramer components.
These components cannot be added nor deleted."
::= { sigChanNisFramerRowStatusEntry 1 }
sigChanNisFramerComponentName OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable provides the component's string name for
use with the ASCII Console Interface"
::= { sigChanNisFramerRowStatusEntry 2 }
sigChanNisFramerStorageType OBJECT-TYPE
SYNTAX StorageType
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This variable represents the storage type value for the
sigChanNisFramer tables."
::= { sigChanNisFramerRowStatusEntry 4 }
sigChanNisFramerIndex OBJECT-TYPE
SYNTAX NonReplicated
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This variable represents the index for the sigChanNisFramer tables."
::= { sigChanNisFramerRowStatusEntry 10 }
sigChanNisFramerProvTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisFramerProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the base provisioning data for the Framer
component. Application or hardware interface specific provisioning
data is contained in other provisionable Framer groups."
::= { sigChanNisFramer 10 }
sigChanNisFramerProvEntry OBJECT-TYPE
SYNTAX SigChanNisFramerProvEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisFramerProvTable."
INDEX {
sigChanIndex,
sigChanNisIndex,
sigChanNisFramerIndex }
::= { sigChanNisFramerProvTable 1 }
SigChanNisFramerProvEntry ::= SEQUENCE {
sigChanNisFramerInterfaceName
Link }
sigChanNisFramerInterfaceName OBJECT-TYPE
SYNTAX Link
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute contains a hardware component name.
The attribute associates the application with a specific link. This
defines the module processor on which Framer's parent component
(as well as Framer itself) will run."
::= { sigChanNisFramerProvEntry 1 }
sigChanNisFramerStateTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisFramerStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the three OSI State attributes. The descriptions
generically indicate what each state attribute implies about the
component. Note that not all the values and state combinations
described here are supported by every component which uses this
group. For component-specific information and the valid state
combinations, refer to NTP 241-7001-150, Passport Operations and
Maintenance Guide."
::= { sigChanNisFramer 12 }
sigChanNisFramerStateEntry OBJECT-TYPE
SYNTAX SigChanNisFramerStateEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisFramerStateTable."
INDEX {
sigChanIndex,
sigChanNisIndex,
sigChanNisFramerIndex }
::= { sigChanNisFramerStateTable 1 }
SigChanNisFramerStateEntry ::= SEQUENCE {
sigChanNisFramerAdminState
INTEGER,
sigChanNisFramerOperationalState
INTEGER,
sigChanNisFramerUsageState
INTEGER }
sigChanNisFramerAdminState OBJECT-TYPE
SYNTAX INTEGER {
locked(0),
unlocked(1),
shuttingDown(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Administrative State of the
component.
The value locked indicates that the component is administratively
prohibited from providing services for its users. A Lock or Lock -
force command has been previously issued for this component.
When the value is locked, the value of usageState must be idle.
The value shuttingDown indicates that the component is
administratively permitted to provide service to its existing users
only. A Lock command was issued against the component and it is
in the process of shutting down.
The value unlocked indicates that the component is administratively
permitted to provide services for its users. To enter this state, issue
an Unlock command to this component."
DEFVAL { unlocked }
::= { sigChanNisFramerStateEntry 1 }
sigChanNisFramerOperationalState OBJECT-TYPE
SYNTAX INTEGER {
disabled(0),
enabled(1) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Operational State of the component.
The value enabled indicates that the component is available for
operation. Note that if adminState is locked, it would still not be
providing service.
The value disabled indicates that the component is not available for
operation. For example, something is wrong with the component
itself, or with another component on which this one depends. If the
value is disabled, the usageState must be idle."
DEFVAL { disabled }
::= { sigChanNisFramerStateEntry 2 }
sigChanNisFramerUsageState OBJECT-TYPE
SYNTAX INTEGER {
idle(0),
active(1),
busy(2) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute indicates the OSI Usage State of the component.
The value idle indicates that the component is not currently in use.
The value active indicates that the component is in use and has
spare capacity to provide for additional users.
The value busy indicates that the component is in use and has no
spare operating capacity for additional users at this time."
DEFVAL { idle }
::= { sigChanNisFramerStateEntry 3 }
sigChanNisFramerStatsTable OBJECT-TYPE
SYNTAX SEQUENCE OF SigChanNisFramerStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This group contains the operational statistics data for a Framer
component."
::= { sigChanNisFramer 13 }
sigChanNisFramerStatsEntry OBJECT-TYPE
SYNTAX SigChanNisFramerStatsEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the sigChanNisFramerStatsTable."
INDEX {
sigChanIndex,
sigChanNisIndex,
sigChanNisFramerIndex }
::= { sigChanNisFramerStatsTable 1 }
SigChanNisFramerStatsEntry ::= SEQUENCE {
sigChanNisFramerFrmToIf
Unsigned32,
sigChanNisFramerFrmFromIf
Unsigned32,
sigChanNisFramerOctetFromIf
Unsigned32,
sigChanNisFramerAborts
Unsigned32,
sigChanNisFramerCrcErrors
Unsigned32,
sigChanNisFramerLrcErrors
Unsigned32,
sigChanNisFramerNonOctetErrors
Unsigned32,
sigChanNisFramerOverruns
Unsigned32,
sigChanNisFramerUnderruns
Unsigned32,
sigChanNisFramerLargeFrmErrors
Unsigned32 }
sigChanNisFramerFrmToIf OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of frames transmitted to the link
interface by Framer.
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 1 }
sigChanNisFramerFrmFromIf OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the number of frames received from the link
interface by Framer.
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 2 }
sigChanNisFramerOctetFromIf OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of bytes received from the link interface by Framer."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 3 }
sigChanNisFramerAborts OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of aborts received.
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 4 }
sigChanNisFramerCrcErrors OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames with CRC errors.
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 5 }
sigChanNisFramerLrcErrors OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames with LRC errors.
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 6 }
sigChanNisFramerNonOctetErrors OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames that were non octet
aligned.
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 7 }
sigChanNisFramerOverruns OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames received from the
link for which overruns occurred.
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 8 }
sigChanNisFramerUnderruns OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames transmitted to the
link for which underruns occurred.
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 9 }
sigChanNisFramerLargeFrmErrors OBJECT-TYPE
SYNTAX Unsigned32 (0..4294967295)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This attribute counts the total number of frames received which
were too large (longer than 500 bytes).
This count wraps to zero after reaching its maximum value."
DEFVAL { 0 }
::= { sigChanNisFramerStatsEntry 10 }
vnetNisSigGroup OBJECT IDENTIFIER ::= { vnetNisSigMIB 1 }
vnetNisSigGroupBE OBJECT IDENTIFIER ::= { vnetNisSigGroup 5 }
vnetNisSigGroupBE01 OBJECT IDENTIFIER ::= { vnetNisSigGroupBE 2 }
vnetNisSigGroupBE01A OBJECT IDENTIFIER ::= { vnetNisSigGroupBE01 2 }
vnetNisSigCapabilities OBJECT IDENTIFIER ::= { vnetNisSigMIB 3 }
vnetNisSigCapabilitiesBE OBJECT IDENTIFIER ::= { vnetNisSigCapabilities 5 }
vnetNisSigCapabilitiesBE01 OBJECT IDENTIFIER ::= { vnetNisSigCapabilitiesBE 2 }
vnetNisSigCapabilitiesBE01A OBJECT IDENTIFIER ::= { vnetNisSigCapabilitiesBE01 2 }
END