HDSL2-SHDSL-LINE-MIB DEFINITIONS ::= BEGIN
IMPORTS
MODULE-IDENTITY,
OBJECT-TYPE,
Counter32,
Unsigned32,
Gauge32,
NOTIFICATION-TYPE,
Integer32,
transmission FROM SNMPv2-SMI
RowStatus,
TEXTUAL-CONVENTION FROM SNMPv2-TC
ifIndex FROM IF-MIB
PerfCurrentCount,
PerfIntervalCount FROM PerfHist-TC-MIB
SnmpAdminString FROM SNMP-FRAMEWORK-MIB
MODULE-COMPLIANCE,
OBJECT-GROUP,
NOTIFICATION-GROUP FROM SNMPv2-CONF;
hdsl2ShdslMIB MODULE-IDENTITY
LAST-UPDATED "200205090000Z" ORGANIZATION "ADSLMIB Working Group"
CONTACT-INFO "WG-email: adslmib@ietf.org
Info: https://www1.ietf.org/mailman/listinfo/adslmib
Chair: Mike Sneed
Postal: P.O. Box 37324
Raleigh NC 27627-7324
Email: sneedmike@hotmail.com
Co-editor: Bob Ray
PESA Switching Systems, Inc.
Postal: 330-A Wynn Drive
Huntsville, AL 35805 USA
Email: rray@pesa.com
Phone: +1 256 726 9200 ext. 142
Co-editor: Rajesh Abbi
Alcatel USA
Postal: 2912 Wake Forest Road
Raleigh, NC 27609-7860 USA
Email: Rajesh.Abbi@alcatel.com
Phone: +1 919 850 6194
"
DESCRIPTION
"This MIB module defines a collection of objects for managing
HDSL2/SHDSL lines. An agent may reside at either end of the
line, however the MIB is designed to require no management
communication between the modems beyond that inherent in the
low-level EOC line protocol as defined in ANSI T1E1.4/2000-006
(for HDSL2 lines), or in ITU G.991.2 (for SHDSL lines)."
REVISION "200205090000Z" DESCRIPTION "Initial version, published as RFC 3276."
::= { transmission 48 }
hdsl2ShdslMibObjects OBJECT IDENTIFIER ::= { hdsl2ShdslMIB 1 }
Hdsl2ShdslPerfCurrDayCount ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A gauge associated with interface performance measurements in
a current 1-day (24 hour) measurement interval.
The value of this gauge starts at zero at the beginning of an
interval and is increased when associated events occur, until
the end of the 1-day interval. At that time the value of the
gauge is stored in the previous 1-day history interval, as
defined in a companion object of type
Hdsl2Shdsl1DayIntevalCount, and the current interval gauge
is restarted at zero.
In the case where the agent has no valid data available for
this interval the corresponding object instance is not
available and upon a retrieval request a corresponding error
message shall be returned to indicate that this instance does
not exist. Please note that zero is a valid value."
SYNTAX Gauge32
Hdsl2Shdsl1DayIntervalCount ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"A counter associated with interface performance measurements
during the most previous 1-day (24 hour) measurement interval.
The value of this gauge is equal to the value of the current
day gauge, as defined in a companion object of type
Hdsl2ShdslPerfCurrDayCount, at the end of its most recent
interval.
In the case where the agent has no valid data available for
this interval the corresponding object instance is not
available and upon a retrieval request a corresponding error
message shall be returned to indicate that this instance does
not exist."
SYNTAX Gauge32
Hdsl2ShdslPerfTimeElapsed ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The number of seconds that have elapsed since the beginning of
the current measurement period. If, for some reason, such as
an adjustment in the system's time-of-day clock or the addition
of a leap second, the current interval exceeds the maximum
value, the agent will return the maximum value.
For 15 minute intervals, the range is limited to (0..899).
For 24 hour intervals, the range is limited to (0..86399)."
SYNTAX Unsigned32(0..86399)
Hdsl2ShdslPerfIntervalThreshold ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This convention defines a range of values that may be set in
a fault threshold alarm control. As the number of seconds in
a 15-minute interval numbers at most 900, objects of this type
may have a range of 0...900, where the value of 0 disables the
alarm."
SYNTAX Unsigned32(0..900)
Hdsl2ShdslUnitId ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This is the unique identification for all units in a
HDSL2/SHDSL Span. It is based on the EOC unit addressing
scheme with reference to the xtuC."
SYNTAX INTEGER
{
xtuC(1),
xtuR(2),
xru1(3),
xru2(4),
xru3(5),
xru4(6),
xru5(7),
xru6(8),
xru7(9),
xru8(10)
}
Hdsl2ShdslUnitSide ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This is the referenced side of a HDSL2/SHDSL unit - Network
or Customer side. The side facing the Network is the Network
side, while the side facing the Customer is the Customer side."
SYNTAX INTEGER
{
networkSide(1),
customerSide(2)
}
Hdsl2ShdslWirePair ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"This is the referenced pair of wires in a HDSL2/SHDSL Segment.
HDSL2 only supports a single pair (wirePair1), while SHDSL
supports an optional second pair (wirePair2)."
SYNTAX INTEGER
{
wirePair1(1),
wirePair2(2)
}
Hdsl2ShdslTransmissionModeType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"Contains the regional setting of the HDSL2/SHDSL span,
represented as a bit-map of possible settings. The various
bit positions are:
Bit Meaning Description
1 region 1 Indicates ITU-T G.991.2 Annex A.
2 region 2 Indicates ITU-T G.991.2 Annex B."
SYNTAX BITS
{
region1(0),
region2(1)
}
Hdsl2ShdslClockReferenceType ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The various STU-C symbol clock references for the
HDSL2/SHDSL span, represented as an enumeration."
SYNTAX INTEGER
{
localClk(1), networkClk(2), dataOrNetworkClk(3), dataClk(4) }
hdsl2ShdslSpanConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslSpanConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports overall configuration of HDSL2/SHDSL
Spans. Entries in this table MUST be maintained in a
persistent manner."
::= { hdsl2ShdslMibObjects 1 }
hdsl2ShdslSpanConfEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslSpanConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslSpanConfTable. Each entry
represents the complete Span in a single HDSL2/SHDSL line.
It is indexed by the ifIndex of the associated HDSL2/SHDSL
line."
INDEX { ifIndex }
::= { hdsl2ShdslSpanConfTable 1 }
Hdsl2ShdslSpanConfEntry ::=
SEQUENCE
{
hdsl2ShdslSpanConfNumRepeaters Unsigned32,
hdsl2ShdslSpanConfProfile SnmpAdminString,
hdsl2ShdslSpanConfAlarmProfile SnmpAdminString
}
hdsl2ShdslSpanConfNumRepeaters OBJECT-TYPE
SYNTAX Unsigned32(0..8)
UNITS "repeaters"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object provisions the number of repeaters/regenerators
in this HDSL2/SHDSL Span."
::= { hdsl2ShdslSpanConfEntry 1 }
hdsl2ShdslSpanConfProfile OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a pointer to a span configuration profile in
the hdsl2ShdslSpanConfProfileTable, which applies to this span.
The value of this object is the index of the referenced profile
in the hdsl2ShdslSpanConfProfileTable. Note that span
configuration profiles are only applicable to SHDSL lines.
HDSL2 lines MUST reference the default profile, 'DEFVAL'.
By default, this object will have the value 'DEFVAL' (the index
of the default profile).
Any attempt to set this object to a value that is not the value
of the index for an active entry in the profile table,
hdsl2ShdslSpanConfProfileTable, MUST be rejected."
::= { hdsl2ShdslSpanConfEntry 2 }
hdsl2ShdslSpanConfAlarmProfile OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object is a pointer to an Alarm configuration profile in
the hdsl2ShdslEndpointAlarmConfProfileTable. The value of this
object is the index of the referenced profile in the
hdsl2ShdslEndpointAlarmConfProfileTable. The alarm threshold
configuration in the referenced profile will be used by default
for all segment endpoints in this span. Individual endpoints
may override this profile by explicitly specifying some other
profile in the hdsl2ShdslEndpointConfTable. By default, this
object will have the value 'DEFVAL' (the index of the default
profile).
Any attempt to set this object to a value that is not the value
of the index for an active entry in the profile table,
hdsl2ShdslEndpointAlarmConfProfileTable, MUST be rejected."
::= { hdsl2ShdslSpanConfEntry 3 }
hdsl2ShdslSpanStatusTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslSpanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides overall status information of
HDSL2/SHDSL spans. This table contains live data from
equipment. As such, it is NOT persistent."
::= { hdsl2ShdslMibObjects 2 }
hdsl2ShdslSpanStatusEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslSpanStatusEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslSpanStatusTable. Each entry
represents the complete span in a single HDSL2/SHDSL line.
It is indexed by the ifIndex of the associated HDSL2/SHDSL
line."
INDEX { ifIndex }
::= { hdsl2ShdslSpanStatusTable 1 }
Hdsl2ShdslSpanStatusEntry ::=
SEQUENCE
{
hdsl2ShdslStatusNumAvailRepeaters Unsigned32,
hdsl2ShdslStatusMaxAttainableLineRate Unsigned32,
hdsl2ShdslStatusActualLineRate Unsigned32,
hdsl2ShdslStatusTransmissionModeCurrent
Hdsl2ShdslTransmissionModeType
}
hdsl2ShdslStatusNumAvailRepeaters OBJECT-TYPE
SYNTAX Unsigned32(0..8)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the actual number of repeaters/regenerators
discovered in this HDSL2/SHDSL span."
::= { hdsl2ShdslSpanStatusEntry 1 }
hdsl2ShdslStatusMaxAttainableLineRate OBJECT-TYPE
SYNTAX Unsigned32(0..4112000)
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the maximum attainable line rate in this HDSL2/SHDSL
span. This object provides the maximum rate the line is
capable of achieving. This is based upon measurements made
during line probing."
::= { hdsl2ShdslSpanStatusEntry 2 }
hdsl2ShdslStatusActualLineRate OBJECT-TYPE
SYNTAX Unsigned32(0..4112000)
UNITS "bps"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the actual line rate in this HDSL2/SHDSL span. This
should equal ifSpeed."
::= { hdsl2ShdslSpanStatusEntry 3 }
hdsl2ShdslStatusTransmissionModeCurrent OBJECT-TYPE
SYNTAX Hdsl2ShdslTransmissionModeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the current Power Spectral Density (PSD) regional
setting of the HDSL2/SHDSL span."
::= { hdsl2ShdslSpanStatusEntry 4 }
hdsl2ShdslInventoryTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslInventoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports retrieval of unit inventory information
available via the EOC from units in a HDSL2/SHDSL line.
Entries in this table are dynamically created during the
line discovery process. The life cycle for these entries
is as follows:
- xtu discovers a device, either a far-end xtu or an xru
- an inventory table entry is created for the device
- the line goes down for whatever reason
- inventory table entries for unreachable devices are
destroyed.
As these entries are created/destroyed dynamically, they
are NOT persistent."
::= { hdsl2ShdslMibObjects 3 }
hdsl2ShdslInventoryEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslInventoryEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslInventoryTable. Each entry
represents inventory information for a single unit in a
HDSL2/SHDSL line. It is indexed by the ifIndex of the
HDSL2/SHDSL line and the Hdsl2ShdslUnitId of the
associated unit."
INDEX { ifIndex, hdsl2ShdslInvIndex }
::= { hdsl2ShdslInventoryTable 1 }
Hdsl2ShdslInventoryEntry ::=
SEQUENCE
{
hdsl2ShdslInvIndex Hdsl2ShdslUnitId,
hdsl2ShdslInvVendorID OCTET STRING,
hdsl2ShdslInvVendorModelNumber OCTET STRING,
hdsl2ShdslInvVendorSerialNumber OCTET STRING,
hdsl2ShdslInvVendorEOCSoftwareVersion Integer32,
hdsl2ShdslInvStandardVersion Integer32,
hdsl2ShdslInvVendorListNumber OCTET STRING,
hdsl2ShdslInvVendorIssueNumber OCTET STRING,
hdsl2ShdslInvVendorSoftwareVersion OCTET STRING,
hdsl2ShdslInvEquipmentCode OCTET STRING,
hdsl2ShdslInvVendorOther OCTET STRING,
hdsl2ShdslInvTransmissionModeCapability
Hdsl2ShdslTransmissionModeType
}
hdsl2ShdslInvIndex OBJECT-TYPE
SYNTAX Hdsl2ShdslUnitId
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry in this table corresponds to a physical element
in a HDSL2/SHDSL Span. It is based on the EOC unit addressing
scheme with reference to the xtuC."
::= { hdsl2ShdslInventoryEntry 1 }
hdsl2ShdslInvVendorID OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(8))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor ID as reported in an Inventory Response message."
::= { hdsl2ShdslInventoryEntry 2 }
hdsl2ShdslInvVendorModelNumber OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor model number as reported in an Inventory Response
message."
::= { hdsl2ShdslInventoryEntry 3 }
hdsl2ShdslInvVendorSerialNumber OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor serial number as reported in an Inventory Response
message."
::= { hdsl2ShdslInventoryEntry 4 }
hdsl2ShdslInvVendorEOCSoftwareVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor EOC version as reported in a Discovery Response
message."
::= { hdsl2ShdslInventoryEntry 5 }
hdsl2ShdslInvStandardVersion OBJECT-TYPE
SYNTAX Integer32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Version of the HDSL2/SHDSL standard implemented, as reported
in an Inventory Response message."
::= { hdsl2ShdslInventoryEntry 6 }
hdsl2ShdslInvVendorListNumber OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(3))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor list number as reported in an Inventory Response
message."
::= { hdsl2ShdslInventoryEntry 7 }
hdsl2ShdslInvVendorIssueNumber OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(2))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor issue number as reported in an Inventory Response
message."
::= { hdsl2ShdslInventoryEntry 8 }
hdsl2ShdslInvVendorSoftwareVersion OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(6))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Vendor software version as reported in an Inventory Response
message."
::= { hdsl2ShdslInventoryEntry 9 }
hdsl2ShdslInvEquipmentCode OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(10))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Equipment code conforming to ANSI T1.213, Coded Identification
of Equipment Entities."
::= { hdsl2ShdslInventoryEntry 10 }
hdsl2ShdslInvVendorOther OBJECT-TYPE
SYNTAX OCTET STRING(SIZE(12))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Other vendor information as reported in an Inventory Response
message."
::= { hdsl2ShdslInventoryEntry 11 }
hdsl2ShdslInvTransmissionModeCapability OBJECT-TYPE
SYNTAX Hdsl2ShdslTransmissionModeType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the transmission mode capability of the SHDSL unit."
::= { hdsl2ShdslInventoryEntry 12 }
hdsl2ShdslEndpointConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslEndpointConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports configuration parameters for segment
endpoints in a HDSL2/SHDSL line. As this table is indexed
by ifIndex, it MUST be maintained in a persistent manner."
::= { hdsl2ShdslMibObjects 4 }
hdsl2ShdslEndpointConfEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslEndpointConfEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslEndpointConfTable. Each entry
represents a single segment endpoint in a HDSL2/SHDSL line.
It is indexed by the ifIndex of the HDSL2/SHDSL line, the
UnitId of the associated unit, the side of the unit, and the
wire-pair of the associated modem."
INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide,
hdsl2ShdslEndpointWirePair}
::= { hdsl2ShdslEndpointConfTable 1 }
Hdsl2ShdslEndpointConfEntry ::=
SEQUENCE
{
hdsl2ShdslEndpointSide Hdsl2ShdslUnitSide,
hdsl2ShdslEndpointWirePair Hdsl2ShdslWirePair,
hdsl2ShdslEndpointAlarmConfProfile SnmpAdminString
}
hdsl2ShdslEndpointSide OBJECT-TYPE
SYNTAX Hdsl2ShdslUnitSide
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The side of the unit associated with this segment endpoint -
Network/Customer side - as per the Hdsl2ShdslUnitSide textual
convention."
::= { hdsl2ShdslEndpointConfEntry 1 }
hdsl2ShdslEndpointWirePair OBJECT-TYPE
SYNTAX Hdsl2ShdslWirePair
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The wire-pair of the modem associated with this segment
endpoint as per the Hdsl2ShdslWirePair textual convention."
::= { hdsl2ShdslEndpointConfEntry 2 }
hdsl2ShdslEndpointAlarmConfProfile OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(0..32))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the alarm threshold values to be used
for this segment endpoint. The values are obtained from the
alarm configuration profile referenced by this object. The
value of this object is the index of the referenced profile in
the hdsl2ShdslEndpointAlarmConfProfileTable, or NULL (a zero-
length SnmpAdminString). If the value is a zero-length
SnmpAdminString, the endpoint uses the default Alarm
Configuration Profile for the associated span as per the
hdsl2ShdslSpanConfAlarmProfile object in the
hdsl2ShdslSpanConfTable. The default value of this object is
a zero-length SnmpAdminString.
Any attempt to set this object to a value that is not the value
of the index for an active entry in the profile table,
hdsl2ShdslEndpointAlarmConfProfileTable, MUST be rejected."
::= { hdsl2ShdslEndpointConfEntry 3 }
hdsl2ShdslEndpointCurrTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslEndpointCurrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table contains current status and performance information
for segment endpoints in HDSL2/SHDSL Lines. As with other
tables in this MIB indexed by ifIndex, entries in this table
MUST be maintained in a persistent manner."
::= { hdsl2ShdslMibObjects 5 }
hdsl2ShdslEndpointCurrEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslEndpointCurrEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslEndpointCurrTable. Each entry
contains status and performance information relating to a
single segment endpoint. It is indexed by the ifIndex of the
HDSL2/SHDSL line, the UnitId of the associated unit, the side
of the unit, and the wire-pair of the associated modem."
INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide,
hdsl2ShdslEndpointWirePair }
::= { hdsl2ShdslEndpointCurrTable 1 }
Hdsl2ShdslEndpointCurrEntry ::=
SEQUENCE
{
hdsl2ShdslEndpointCurrAtn Integer32,
hdsl2ShdslEndpointCurrSnrMgn Integer32,
hdsl2ShdslEndpointCurrStatus BITS,
hdsl2ShdslEndpointES Counter32,
hdsl2ShdslEndpointSES Counter32,
hdsl2ShdslEndpointCRCanomalies Counter32,
hdsl2ShdslEndpointLOSWS Counter32,
hdsl2ShdslEndpointUAS Counter32,
hdsl2ShdslEndpointCurr15MinTimeElapsed
Hdsl2ShdslPerfTimeElapsed,
hdsl2ShdslEndpointCurr15MinES PerfCurrentCount,
hdsl2ShdslEndpointCurr15MinSES PerfCurrentCount,
hdsl2ShdslEndpointCurr15MinCRCanomalies PerfCurrentCount,
hdsl2ShdslEndpointCurr15MinLOSWS PerfCurrentCount,
hdsl2ShdslEndpointCurr15MinUAS PerfCurrentCount,
hdsl2ShdslEndpointCurr1DayTimeElapsed
Hdsl2ShdslPerfTimeElapsed,
hdsl2ShdslEndpointCurr1DayES
Hdsl2ShdslPerfCurrDayCount,
hdsl2ShdslEndpointCurr1DaySES
Hdsl2ShdslPerfCurrDayCount,
hdsl2ShdslEndpointCurr1DayCRCanomalies
Hdsl2ShdslPerfCurrDayCount,
hdsl2ShdslEndpointCurr1DayLOSWS
Hdsl2ShdslPerfCurrDayCount,
hdsl2ShdslEndpointCurr1DayUAS
Hdsl2ShdslPerfCurrDayCount
}
hdsl2ShdslEndpointCurrAtn OBJECT-TYPE
SYNTAX Integer32(-127..128)
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current loop attenuation for this endpoint as reported in
a Network or Customer Side Performance Status message."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 1 }
hdsl2ShdslEndpointCurrSnrMgn OBJECT-TYPE
SYNTAX Integer32(-127..128)
UNITS "dB"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The current SNR margin for this endpoint as reported in a
Status Response/SNR message."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 2 }
hdsl2ShdslEndpointCurrStatus OBJECT-TYPE
SYNTAX BITS
{
noDefect(0),
powerBackoff(1),
deviceFault(2),
dcContinuityFault(3),
snrMarginAlarm(4),
loopAttenuationAlarm(5),
loswFailureAlarm(6),
configInitFailure(7),
protocolInitFailure(8),
noNeighborPresent(9),
loopbackActive(10)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Contains the current state of the endpoint. This is a
bitmap of possible conditions. The various bit positions
are:
noDefect There no defects on the line.
powerBackoff Indicates enhanced Power Backoff.
deviceFault Indicates a vendor-dependent
diagnostic or self-test fault
has been detected.
dcContinuityFault Indicates vendor-dependent
conditions that interfere with
span powering such as short and
open circuits.
snrMarginAlarm Indicates that the SNR margin
has dropped below the alarm threshold.
loopAttenuationAlarm Indicates that the loop attenuation
exceeds the alarm threshold.
loswFailureAlarm Indicates a forward LOSW alarm.
configInitFailure Endpoint failure during initialization
due to paired endpoint not able to
support requested configuration.
protocolInitFailure Endpoint failure during initialization
due to incompatible protocol used by
the paired endpoint.
noNeighborPresent Endpoint failure during initialization
due to no activation sequence detected
from paired endpoint.
loopbackActive A loopback is currently active at this
Segment Endpoint.
This is intended to supplement ifOperStatus. Note that there
is a 1-1 relationship between the status bits defined in this
object and the notification thresholds defined elsewhere in
this MIB."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 3 }
hdsl2ShdslEndpointES OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Errored Seconds (ES) on this endpoint since the xU
was last restarted."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 4 }
hdsl2ShdslEndpointSES OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Severely Errored Seconds (SES) on this endpoint
since the xU was last restarted."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 5 }
hdsl2ShdslEndpointCRCanomalies OBJECT-TYPE
SYNTAX Counter32
UNITS "detected CRC Anomalies"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of CRC anomalies on this endpoint since the xU was
last restarted."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 6 }
hdsl2ShdslEndpointLOSWS OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Loss of Sync Word (LOSW) Seconds on this endpoint
since the xU was last restarted."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 7 }
hdsl2ShdslEndpointUAS OBJECT-TYPE
SYNTAX Counter32
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Unavailable Seconds (UAS) on this endpoint since
the xU was last restarted."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 8 }
hdsl2ShdslEndpointCurr15MinTimeElapsed OBJECT-TYPE
SYNTAX Hdsl2ShdslPerfTimeElapsed
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Total elapsed seconds in the current 15-minute interval."
::= { hdsl2ShdslEndpointCurrEntry 9 }
hdsl2ShdslEndpointCurr15MinES OBJECT-TYPE
SYNTAX PerfCurrentCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Errored Seconds (ES) in the current 15-minute
interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 10 }
hdsl2ShdslEndpointCurr15MinSES OBJECT-TYPE
SYNTAX PerfCurrentCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Severely Errored Seconds (SES) in the current
15-minute interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 11 }
hdsl2ShdslEndpointCurr15MinCRCanomalies OBJECT-TYPE
SYNTAX PerfCurrentCount
UNITS "detected CRC Anomalies"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of CRC anomalies in the current 15-minute interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 12 }
hdsl2ShdslEndpointCurr15MinLOSWS OBJECT-TYPE
SYNTAX PerfCurrentCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Loss of Sync Word (LOSW) Seconds in the current
15-minute interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 13 }
hdsl2ShdslEndpointCurr15MinUAS OBJECT-TYPE
SYNTAX PerfCurrentCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Unavailable Seconds (UAS) in the current 15-minute
interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 14 }
hdsl2ShdslEndpointCurr1DayTimeElapsed OBJECT-TYPE
SYNTAX Hdsl2ShdslPerfTimeElapsed
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Number of seconds that have elapsed since the beginning of
the current 1-day interval."
::= { hdsl2ShdslEndpointCurrEntry 15 }
hdsl2ShdslEndpointCurr1DayES OBJECT-TYPE
SYNTAX Hdsl2ShdslPerfCurrDayCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Errored Seconds (ES) during the current day as
measured by hdsl2ShdslEndpointCurr1DayTimeElapsed."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 16 }
hdsl2ShdslEndpointCurr1DaySES OBJECT-TYPE
SYNTAX Hdsl2ShdslPerfCurrDayCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Severely Errored Seconds (SES) during the current
day as measured by hdsl2ShdslEndpointCurr1DayTimeElapsed."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 17 }
hdsl2ShdslEndpointCurr1DayCRCanomalies OBJECT-TYPE
SYNTAX Hdsl2ShdslPerfCurrDayCount
UNITS "detected CRC Anomalies"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of CRC anomalies during the current day as measured
by hdsl2ShdslEndpointCurr1DayTimeElapsed."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 18 }
hdsl2ShdslEndpointCurr1DayLOSWS OBJECT-TYPE
SYNTAX Hdsl2ShdslPerfCurrDayCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Loss of Sync Word (LOSW) Seconds during the current
day as measured by hdsl2ShdslEndpointCurr1DayTimeElapsed."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 19 }
hdsl2ShdslEndpointCurr1DayUAS OBJECT-TYPE
SYNTAX Hdsl2ShdslPerfCurrDayCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Unavailable Seconds (UAS) during the current day as
measured by hdsl2ShdslEndpointCurr1DayTimeElapsed."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2ShdslEndpointCurrEntry 20 }
hdsl2Shdsl15MinIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2Shdsl15MinIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for each HDSL2/SHDSL endpoint
performance data collection interval. This table contains
live data from equipment. As such, it is NOT persistent."
::= { hdsl2ShdslMibObjects 6 }
hdsl2Shdsl15MinIntervalEntry OBJECT-TYPE
SYNTAX Hdsl2Shdsl15MinIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2Shdsl15MinIntervalTable."
INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide,
hdsl2ShdslEndpointWirePair, hdsl2Shdsl15MinIntervalNumber}
::= { hdsl2Shdsl15MinIntervalTable 1 }
Hdsl2Shdsl15MinIntervalEntry ::=
SEQUENCE
{
hdsl2Shdsl15MinIntervalNumber Unsigned32,
hdsl2Shdsl15MinIntervalES PerfIntervalCount,
hdsl2Shdsl15MinIntervalSES PerfIntervalCount,
hdsl2Shdsl15MinIntervalCRCanomalies PerfIntervalCount,
hdsl2Shdsl15MinIntervalLOSWS PerfIntervalCount,
hdsl2Shdsl15MinIntervalUAS PerfIntervalCount
}
hdsl2Shdsl15MinIntervalNumber OBJECT-TYPE
SYNTAX Unsigned32(1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Performance Data Interval number. 1 is the the most recent
previous interval; interval 96 is 24 hours ago. Intervals
2..96 are optional."
::= { hdsl2Shdsl15MinIntervalEntry 1 }
hdsl2Shdsl15MinIntervalES OBJECT-TYPE
SYNTAX PerfIntervalCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Errored Seconds (ES) during the interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl15MinIntervalEntry 2 }
hdsl2Shdsl15MinIntervalSES OBJECT-TYPE
SYNTAX PerfIntervalCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Severely Errored Seconds (SES) during the interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl15MinIntervalEntry 3 }
hdsl2Shdsl15MinIntervalCRCanomalies OBJECT-TYPE
SYNTAX PerfIntervalCount
UNITS "detected CRC Anomalies"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of CRC anomalies during the interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl15MinIntervalEntry 4 }
hdsl2Shdsl15MinIntervalLOSWS OBJECT-TYPE
SYNTAX PerfIntervalCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Loss of Sync Word (LOSW) Seconds during the
interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl15MinIntervalEntry 5 }
hdsl2Shdsl15MinIntervalUAS OBJECT-TYPE
SYNTAX PerfIntervalCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Unavailable Seconds (UAS) during the interval."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl15MinIntervalEntry 6 }
hdsl2Shdsl1DayIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2Shdsl1DayIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table provides one row for each HDSL2/SHDSL endpoint
performance data collection interval. This table contains
live data from equipment. As such, it is NOT persistent."
::= { hdsl2ShdslMibObjects 7 }
hdsl2Shdsl1DayIntervalEntry OBJECT-TYPE
SYNTAX Hdsl2Shdsl1DayIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2Shdsl1DayIntervalTable."
INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide,
hdsl2ShdslEndpointWirePair, hdsl2Shdsl1DayIntervalNumber }
::= { hdsl2Shdsl1DayIntervalTable 1 }
Hdsl2Shdsl1DayIntervalEntry ::=
SEQUENCE
{
hdsl2Shdsl1DayIntervalNumber Unsigned32,
hdsl2Shdsl1DayIntervalMoniSecs Hdsl2ShdslPerfTimeElapsed,
hdsl2Shdsl1DayIntervalES Hdsl2Shdsl1DayIntervalCount,
hdsl2Shdsl1DayIntervalSES Hdsl2Shdsl1DayIntervalCount,
hdsl2Shdsl1DayIntervalCRCanomalies Hdsl2Shdsl1DayIntervalCount,
hdsl2Shdsl1DayIntervalLOSWS Hdsl2Shdsl1DayIntervalCount,
hdsl2Shdsl1DayIntervalUAS Hdsl2Shdsl1DayIntervalCount
}
hdsl2Shdsl1DayIntervalNumber OBJECT-TYPE
SYNTAX Unsigned32(1..30)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"History Data Interval number. Interval 1 is the the most
recent previous day; interval 30 is 30 days ago. Intervals
2..30 are optional."
::= { hdsl2Shdsl1DayIntervalEntry 1 }
hdsl2Shdsl1DayIntervalMoniSecs OBJECT-TYPE
SYNTAX Hdsl2ShdslPerfTimeElapsed
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The amount of time in the 1-day interval over which the
performance monitoring information is actually counted.
This value will be the same as the interval duration except
in a situation where performance monitoring data could not
be collected for any reason."
::= { hdsl2Shdsl1DayIntervalEntry 2 }
hdsl2Shdsl1DayIntervalES OBJECT-TYPE
SYNTAX Hdsl2Shdsl1DayIntervalCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Errored Seconds (ES) during the 1-day interval as
measured by hdsl2Shdsl1DayIntervalMoniSecs."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl1DayIntervalEntry 3 }
hdsl2Shdsl1DayIntervalSES OBJECT-TYPE
SYNTAX Hdsl2Shdsl1DayIntervalCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Severely Errored Seconds (SES) during the 1-day
interval as measured by hdsl2Shdsl1DayIntervalMoniSecs."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl1DayIntervalEntry 4 }
hdsl2Shdsl1DayIntervalCRCanomalies OBJECT-TYPE
SYNTAX Hdsl2Shdsl1DayIntervalCount
UNITS "detected CRC Anomalies"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of CRC anomalies during the 1-day interval as
measured by hdsl2Shdsl1DayIntervalMoniSecs."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl1DayIntervalEntry 5 }
hdsl2Shdsl1DayIntervalLOSWS OBJECT-TYPE
SYNTAX Hdsl2Shdsl1DayIntervalCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Loss of Sync Word (LOSW) Seconds during the 1-day
interval as measured by hdsl2Shdsl1DayIntervalMoniSecs."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl1DayIntervalEntry 6 }
hdsl2Shdsl1DayIntervalUAS OBJECT-TYPE
SYNTAX Hdsl2Shdsl1DayIntervalCount
UNITS "seconds"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Count of Unavailable Seconds (UAS) during the 1-day interval
as measured by hdsl2Shdsl1DayIntervalMoniSecs."
REFERENCE "HDSL2 Section 7.5.3.7; SHDSL Section 9.5.5.7"
::= { hdsl2Shdsl1DayIntervalEntry 7 }
hdsl2ShdslEndpointMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslEndpointMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports maintenance operations (eg. loopbacks)
to be performed on HDSL2/SHDSL segment endpoints. This table
contains live data from equipment. As such, it is NOT
persistent."
::= { hdsl2ShdslMibObjects 8 }
hdsl2ShdslEndpointMaintEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslEndpointMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslEndpointMaintTable. Each entry
corresponds to a single segment endpoint, and is indexed by the
ifIndex of the HDSL2/SHDSL line, the UnitId of the associated
unit and the side of the unit."
INDEX { ifIndex, hdsl2ShdslInvIndex, hdsl2ShdslEndpointSide }
::= { hdsl2ShdslEndpointMaintTable 1 }
Hdsl2ShdslEndpointMaintEntry ::=
SEQUENCE
{
hdsl2ShdslMaintLoopbackConfig INTEGER,
hdsl2ShdslMaintTipRingReversal INTEGER,
hdsl2ShdslMaintPowerBackOff INTEGER,
hdsl2ShdslMaintSoftRestart INTEGER
}
hdsl2ShdslMaintLoopbackConfig OBJECT-TYPE
SYNTAX INTEGER
{
noLoopback(1),
normalLoopback(2),
specialLoopback(3)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object controls configuration of loopbacks for the
associated segment endpoint. The status of the loopback
is obtained via the hdsl2ShdslEndpointCurrStatus object."
::= { hdsl2ShdslEndpointMaintEntry 1 }
hdsl2ShdslMaintTipRingReversal OBJECT-TYPE
SYNTAX INTEGER
{
normal(1),
reversed(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the state of the tip/ring pair at the
associated segment endpoint."
::= { hdsl2ShdslEndpointMaintEntry 2 }
hdsl2ShdslMaintPowerBackOff OBJECT-TYPE
SYNTAX INTEGER
{
default(1),
enhanced(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the receiver at the associated
segment endpoint to operate in default or enhanced power
backoff mode."
::= { hdsl2ShdslEndpointMaintEntry 3 }
hdsl2ShdslMaintSoftRestart OBJECT-TYPE
SYNTAX INTEGER
{
ready(1),
restart(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object enables the manager to trigger a soft restart
of the modem at the associated segment endpoint. The manager
may only set this object to the 'restart(2)' value, which
initiates a restart. The agent will perform a restart after
approximately 5 seconds. Following the 5 second period, the
agent will restore the object to the 'ready(1)' state."
::= { hdsl2ShdslEndpointMaintEntry 4 }
hdsl2ShdslUnitMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslUnitMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports maintenance operations for units in a
HDSL2/SHDSL line. Entries in this table MUST be maintained
in a persistent manner."
::= { hdsl2ShdslMibObjects 9 }
hdsl2ShdslUnitMaintEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslUnitMaintEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the hdsl2ShdslUnitMaintTable. Each entry
corresponds to a single unit, and is indexed by the ifIndex
of the HDSL2/SHDSL line and the UnitId of the associated
unit."
INDEX { ifIndex, hdsl2ShdslInvIndex }
::= { hdsl2ShdslUnitMaintTable 1 }
Hdsl2ShdslUnitMaintEntry ::=
SEQUENCE
{
hdsl2ShdslMaintLoopbackTimeout Integer32,
hdsl2ShdslMaintUnitPowerSource INTEGER
}
hdsl2ShdslMaintLoopbackTimeout OBJECT-TYPE
SYNTAX Integer32(0..4095)
UNITS "minutes"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This object configures the timeout value for loopbacks
initiated at segments endpoints contained in the associated
unit. A value of 0 disables the timeout."
::= { hdsl2ShdslUnitMaintEntry 1 }
hdsl2ShdslMaintUnitPowerSource OBJECT-TYPE
SYNTAX INTEGER
{
local(1),
span(2)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This object indicates the DC power source being used by the
associated unit."
::= { hdsl2ShdslUnitMaintEntry 2 }
hdsl2ShdslSpanConfProfileTable OBJECT-TYPE
SYNTAX SEQUENCE OF Hdsl2ShdslSpanConfProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This table supports definitions of span configuration
profiles for SHDSL lines. HDSL2 does not support these
configuration options. This table MUST be maintained
in a persistent manner."
::= { hdsl2ShdslMibObjects 10 }
hdsl2ShdslSpanConfProfileEntry OBJECT-TYPE
SYNTAX Hdsl2ShdslSpanConfProfileEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Each entry corresponds to a single span configuration
profile. Each profile contains a set of span configuration
parameters. The configuration parameters in a profile are
applied to those lines referencing that profile (see the
hdsl2ShdslSpanConfProfile object). Profiles may be
created/deleted using the row creation/deletion mechanism
via hdsl2ShdslSpanConfProfileRowStatus. If an active
entry is referenced in hdsl2ShdslSpanConfProfile, the
entry MUST remain active until all references are removed."
INDEX { IMPLIED hdsl2ShdslSpanConfProfileName }
::= { hdsl2ShdslSpanConfProfileTable 1 }
Hdsl2ShdslSpanConfProfileEntry ::=
SEQUENCE
{
hdsl2ShdslSpanConfProfileName SnmpAdminString,
hdsl2ShdslSpanConfWireInterface INTEGER,
hdsl2ShdslSpanConfMinLineRate Unsigned32,
hdsl2ShdslSpanConfMaxLineRate Unsigned32,
hdsl2ShdslSpanConfPSD INTEGER,
hdsl2ShdslSpanConfTransmissionMode
Hdsl2ShdslTransmissionModeType,
hdsl2ShdslSpanConfRemoteEnabled INTEGER,
hdsl2ShdslSpanConfPowerFeeding INTEGER,
hdsl2ShdslSpanConfCurrCondTargetMarginDown Integer32,
hdsl2ShdslSpanConfWorstCaseTargetMarginDown Integer32,
hdsl2ShdslSpanConfCurrCondTargetMarginUp Integer32,
hdsl2ShdslSpanConfWorstCaseTargetMarginUp Integer32,
hdsl2ShdslSpanConfUsedTargetMargins BITS,
hdsl2ShdslSpanConfReferenceClock
Hdsl2ShdslClockReferenceType,
hdsl2ShdslSpanConfLineProbeEnable INTEGER,
hdsl2ShdslSpanConfProfileRowStatus RowStatus
}
hdsl2ShdslSpanConfProfileName OBJECT-TYPE
SYNTAX SnmpAdminString (SIZE(1..32))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"This object is the unique index associated with this profile.
Entries in this table are referenced via the object
hdsl2ShdslSpanConfProfile in Hdsl2ShdslSpanConfEntry."
::= { hdsl2ShdslSpanConfProfileEntry 1 }
hdsl2ShdslSpanConfWireInterface OBJECT-TYPE
SYNTAX INTEGER
{
twoWire(1),
fourWire(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object configures the two-wire or optional four-wire
operation for SHDSL Lines."
DEFVAL { twoWire }
::= { hdsl2ShdslSpanConfProfileEntry 2 }
hdsl2ShdslSpanConfMinLineRate OBJECT-TYPE
SYNTAX Unsigned32(0..4112000)
UNITS "bps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object configures the minimum transmission rate for
the associated SHDSL Line in bits-per-second (bps). If
the minimum line rate equals the maximum line rate
(hdsl2ShdslSpanMaxLineRate), the line rate is considered
'fixed'. If the minimum line rate is less than the maximum
line rate, the line rate is considered 'rate-adaptive'."
DEFVAL { 1552000 }
::= { hdsl2ShdslSpanConfProfileEntry 3 }
hdsl2ShdslSpanConfMaxLineRate OBJECT-TYPE
SYNTAX Unsigned32(0..4112000)
UNITS "bps"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object configures the maximum transmission rate for
the associated SHDSL Line in bits-per-second (bps). If
the minimum line rate equals the maximum line rate
(hdsl2ShdslSpanMaxLineRate), the line rate is considered
'fixed'. If the minimum line rate is less than the maximum
line rate, the line rate is considered 'rate-adaptive'."
DEFVAL { 1552000 }
::= { hdsl2ShdslSpanConfProfileEntry 4 }
hdsl2ShdslSpanConfPSD OBJECT-TYPE
SYNTAX INTEGER
{
symmetric(1),
asymmetric(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object configures use of symmetric/asymmetric PSD (Power
Spectral Density) Mask for the associated SHDSL Line. Support
for symmetric PSD is mandatory for all supported data rates.
Support for asymmetric PSD is optional."
DEFVAL { symmetric }
::= { hdsl2ShdslSpanConfProfileEntry 5 }
hdsl2ShdslSpanConfTransmissionMode OBJECT-TYPE
SYNTAX Hdsl2ShdslTransmissionModeType
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object specifies the regional setting for the SHDSL
line."
DEFVAL { { region1 } }
::= { hdsl2ShdslSpanConfProfileEntry 6 }
hdsl2ShdslSpanConfRemoteEnabled OBJECT-TYPE
SYNTAX INTEGER
{
enabled(1),
disabled(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"This object enables/disables support for remote management
of the units in a SHDSL line from the STU-R via the EOC."