SNMP MIB Search

   Sample: altiga stat   Advanced Search
Donate your MIB  
Search:   
   
 
Return to vendor list
View objects
Download mib file
Vendor: SynOptics
Mib: SYNOPTICS-COMMON-MIB
Version: 1


Mib source:
-- This file contains the concatenation of the following
-- SynOptics MIB modules/files:
--    com3.2-09.30.91
--    enet3.3-10.25.91
--    ieee802.3-1.0-09.30.91
--    tr3.1-10.25.91
--    traps1.0-09.30.91


-- file:  com3.2-09.30.91

SYNOPTICS-COMMON-MIB

-- Common MIB Release 3.2
-- DRAFT Revision 9/30/91
-- Printed 10/7/91

-- Copyright 1991 SynOptics Communications, Inc.  All Rights
-- Reserved.  Reproduction of this document is authorized on
-- condition that the foregoing copyright notice is included.
-- This SynOptics SNMP Management Information Base Specification
-- (Specification) embodies SynOptics' confidential and
-- proprietary intellectual property.  SynOptics retains all
-- title and ownership in the Specification, including any
-- revisions.  
--
-- It is SynOptics intent to encourage the widespread use of
-- this Specification in connection with the management of
-- SynOptics products. SynOptics grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of SynOptics products.
--
-- This Specification is supplied "AS IS," and SynOptics makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.


DEFINITIONS ::= BEGIN

-- SECTION 1: Top Level Definitions

-- Imports

IMPORTS
	enterprises, Gauge, 
	TimeTicks, IpAddress		FROM RFC1155-SMI
	DisplayString			FROM RFC1213-MIB
	OBJECT-TYPE			FROM RFC-1212;

-- Textual Conventions

S3BackplaneType ::=
	INTEGER {
		other(1),		  -- none of the following
		ethernet(2),		  -- ethernet
		ethernetTokenRing(3),	  -- ethernet and token ring
		ethernetFddi(4),	  -- ethernet and FDDI
		ethernetTokenRingFddi(5), -- ethernet, token ring, and FDDI
		ethernetTokenRingRedundant(6),	-- redundant backplane
		ethernetTokenRingFddiRedund(7)	-- redundant backplane
	}
-- This type is used to specify a concentrator backplane.


S3ChassisType ::=
	INTEGER {
		other(1),	-- none of the following
		m3000(2),	-- model 3000
		m3030(3),	-- model 3030
		m2310(4),	-- model 2310
		m2810(5)	-- model 2810
	}
-- This type is used to specify a concentrator chassis.


S3ModuleType ::=
	INTEGER {
		empty(1),	-- nothing installed
		other(2),	-- none of the following
		m3302(3),	-- STP ethernet Host Module
		m3304-ST(4),	-- FOIRL ethernet Host Module
		m3305(5),	-- UTP ethernet Host Module
		m3308(6),	-- 10 base-T ethernet Host Module
		m3313(7),	-- AUI ethernet NMM w/ RS232 port
		m3313M(8),	-- AUI ethernet NMM w/ RS232 + modem
		m3314-ST(9),	-- FOIRL ethernet NMM w/ RS232
		m3314M-ST(10),	-- FOIRL ethernet NMM w/ RS232 + modem
		m3323(11),	-- AUI Local Bridge
		m3324-ST(12),	-- FOIRL Local Bridge
		m3502(13),	-- STP Token Ring Host Module
		m3532(14),	-- STP Token Ring Repeater
		m3552(15),	-- STP Ring in/ Ring out Module
		m3301(16),	-- Thin Net ethernet Host Module
		m3307(17),	-- 10 base-T 50 pin Host Module
		m3356(18),	-- Ethernet Remote Bridge
		m3512(19),	-- T.R. NMM w/ STP ring in/ring out
		m3514(20),	-- T.R. NMM w/ FOIRL ring in/ring out
		m3505(21),	-- UTP Token Ring Host Module
		m3554(22),	-- FOIRL ring in/ring out Module
		m3534(23),	-- FOIRL Repeater
		m3383(24),	-- AUI ethernet Local Router
		m3384(25),	-- FOIRL ethernet Local Router
		m331x(26),	-- ethernet NMM module w/unknown MDA type
		m351x(27),	-- t.r. NMM module w/unknown MDA type
		m3502-A(28),	-- STP Token Ring Host Module
		m3902(29),	-- STP FDDI Host Module
		m3904(30),	-- Fiber FDDI Host Module
		m3910S(31),	-- FDDI Super NMM
		m3386(32),	-- Cisco Remote Router
		m3394(33),	-- Ethernet-localtalk router
		m3395(34),	-- XYPLEX terminal server
		m3323S(35),	-- High Speed Local Bridge with AUI
		m3324S-ST(36),	-- High Speed Local Bridge with FOIRL
		m3307A(37),	-- 10baseT with amp connector
		m3308A(38),	-- 10baseT (Ibid)
		m3505A(39),	-- UTP Token Ring Host Module
		m3513(40),	-- STP TR repeater NMM
		m3333(41),	-- ethernet retiming module AUI
		m3334-ST(42),	-- ethernet retiming module FOIRL
		m3040(43),	-- model 3040 NCE (SPARCStation on a card)
		m3100R(44),	-- 3100R Summing Module
		m2810-hm(47),	-- host part of 2810 non-modular Ethernet
		m2810-nmm(48)	-- nmm part of 2810 non-modular Ethernet
	}
-- This type is used to specify a module.


S3PsType ::=
	INTEGER {
		other(1),		-- none of the following
		low(2),			-- 200 watt supply (3000)
					-- 50 watt supply (2810)
		medium(3),		-- 360 watt supply (3000)
					-- 110 watt supply (3030)
		high(4),		-- 460 watt supply (3000)
					-- 150 watt supply (3030)
		redundantCapable(5) 	-- redundant backplane (3000)
	}
-- This type is used to specify the power supply type. Where used, the 
-- descriptions specify the valid values.


-- Categories

synoptics			OBJECT IDENTIFIER ::=	{ enterprises 45 }

products			OBJECT IDENTIFIER ::=	{ synoptics 1 }
temporary			OBJECT IDENTIFIER ::=	{ synoptics 2 }
registration			OBJECT IDENTIFIER ::=	{ synoptics 3 }

-- Groups

series1000			OBJECT IDENTIFIER ::=	{ products 1 }
s3SnmpAgent			OBJECT IDENTIFIER ::=	{ products 2 }
series3000			OBJECT IDENTIFIER ::=	{ products 3 }

ieee8023			OBJECT IDENTIFIER ::=	{ temporary 1 }

s3000Chassis			OBJECT IDENTIFIER ::=	{ series3000 1 }
s3000Ethernet			OBJECT IDENTIFIER ::=	{ series3000 2 }
s3000TokenRing			OBJECT IDENTIFIER ::=	{ series3000 3 }
s3000FDDI			OBJECT IDENTIFIER ::=	{ series3000 4 }

s3000Bridge			OBJECT IDENTIFIER ::=	{ series3000 5 }
s3000TerminalServer		OBJECT IDENTIFIER ::=	{ series3000 6 }

s3AgentSw			OBJECT IDENTIFIER ::=	{ s3SnmpAgent 1 }
s3AgentNetProtocol		OBJECT IDENTIFIER ::=	{ s3SnmpAgent 2 }
-- this one is defined in section 4.
-- s3AgentTrapReceiverTable	OBJECT IDENTIFIER ::=	{ s3SnmpAgent 3 }
s3AgentHw			OBJECT IDENTIFIER ::=	{ s3SnmpAgent 4 }
s3AgentSpecific			OBJECT IDENTIFIER ::=	{ s3SnmpAgent 5 }
s3AgentLocImage			OBJECT IDENTIFIER ::=	{ s3SnmpAgent 6 }

s3AgentIpProtocol	OBJECT IDENTIFIER ::=	{ s3AgentNetProtocol 1 }


-- Products
-- These object identifiers are for use as values for sysObjectId.


s3reg-other			OBJECT IDENTIFIER ::=	{ registration 1 }

s3reg-3000			OBJECT IDENTIFIER ::=	{ registration 2 }
s3reg-3000-enetNMM		OBJECT IDENTIFIER ::=	{ s3reg-3000 1 }
s3reg-3000-trNMM		OBJECT IDENTIFIER ::=	{ s3reg-3000 2 }
s3reg-3000-FDDI-NMM		OBJECT IDENTIFIER ::=	{ s3reg-3000 3 }

s3reg-3030			OBJECT IDENTIFIER ::=	{ registration 3 }
s3reg-3030-enetNMM		OBJECT IDENTIFIER ::=	{ s3reg-3030 1 }
s3reg-3030-trNMM		OBJECT IDENTIFIER ::=	{ s3reg-3030 2 }
s3reg-3030-FDDI-NMM		OBJECT IDENTIFIER ::=	{ s3reg-3030 3 }

s3reg-2310			OBJECT IDENTIFIER ::=	{ registration 4 }
s3reg-2310-enetNMM		OBJECT IDENTIFIER ::=	{ s3reg-2310 1 }

s3reg-332X			OBJECT IDENTIFIER ::=	{ registration 5 }
s3reg-332XS			OBJECT IDENTIFIER ::=	{ registration 6 }
s3reg-3356			OBJECT IDENTIFIER ::=	{ registration 7 }

s3reg-2810			OBJECT IDENTIFIER ::=	{ registration 8 }
s3reg-2810-enetNMM		OBJECT IDENTIFIER ::=	{ s3reg-2810 1 }


-- SECTION 2: Concentrator Chassis
-- Chassis Group

-- Implementation of this group is mandatory for all SynOptics Series 3000 
-- agents.

s3ChassisType OBJECT-TYPE
	SYNTAX	S3ChassisType
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis type."
	::= { s3000Chassis 1 }

s3ChassisBkplType OBJECT-TYPE
	SYNTAX	S3BackplaneType
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis backplane type."
	::= { s3000Chassis 2 }

s3ChassisBkplRev OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis backplane revision."
	::= { s3000Chassis 3 }

s3ChassisPsType OBJECT-TYPE
	SYNTAX	S3PsType
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis power supply type."
	::= { s3000Chassis 4 }

s3ChassisPsStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		ok(1),			-- supply ok
		primaryFail(2),		-- primary power supply failure
		secondaryFail(3),	-- secondary power supply failure
		bothFail(4)		-- both power supplies failed
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The chassis power supply status."
	::= { s3000Chassis 5 }

s3ChassisFanStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		ok(1),			-- fans are running
		fail(2),		-- fan(s) are broken
		other(3)		-- unknown fan status or no fan
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The status of the chassis cooling fan."
	::= { s3000Chassis 6 }



-- Chassis Slot Configuration Table


s3SlotConfigTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF S3SlotConfigEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"The chassis slot configuration table."
	::= { s3000Chassis 7 }

s3SlotConfigEntry OBJECT-TYPE
	SYNTAX	S3SlotConfigEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"What type of module is in each slot of the chassis."
	INDEX	{ s3SlotNumber }
	::= { s3SlotConfigTable 1 }


S3SlotConfigEntry ::= SEQUENCE {
	s3SlotNumber
		INTEGER,
	s3SlotModuleId
		INTEGER,
	s3SlotModuleType
		S3ModuleType,
	s3SlotModuleDescr
		DisplayString,
	s3SlotModuleLed
		OCTET STRING,
	s3SlotModuleMdaId
		INTEGER
}

s3SlotNumber OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The 3000 Chassis slot number. Valid entries are 1-12."
	::= { s3SlotConfigEntry 1 }

s3SlotModuleId OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"ID for the module."
	::= { s3SlotConfigEntry 2 }

s3SlotModuleType OBJECT-TYPE
	SYNTAX	S3ModuleType
	ACCESS	read-only
	STATUS	deprecated
	DESCRIPTION
		"The type of module this entry represents."
	::= { s3SlotConfigEntry 3 }

s3SlotModuleDescr OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..128))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Module description."
	::= { s3SlotConfigEntry 4 }

s3SlotModuleLed OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(8))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Status of the module LEDs."
	::= { s3SlotConfigEntry 5 }

s3SlotModuleMdaId OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"ID of the medium-dependent part of the board.  The value
		is board dependent."
	::= { s3SlotConfigEntry 6 }



-- Chassis Common Board Table


s3CommonBoardTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF S3CommonBoardEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A table containing information about the boards currently 
		plugged	into the 3000 Chassis.  This board table contains an 
		entry for each non-empty slot in the s3SlotConfigTable, EXCEPT
		for those slots containing Retiming Modules.
		All of the information in this board table is retrievable 
		using the NMI commands that are common to all boards integrated
 		into the SynOptics Series 3000 Concentrators."
	::= { s3000Chassis 8 }

s3CommonBoardEntry OBJECT-TYPE
	SYNTAX	S3CommonBoardEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A table entry containing information about a single Board 
		currently plugged into the 3000 Chassis. These values can be 
		retrieved using the common board NMI commands."
	INDEX	{ s3CommonBoardIndex }
	::= { s3CommonBoardTable 1 }

S3CommonBoardEntry ::= SEQUENCE {
	s3CommonBoardIndex
		INTEGER,
	s3CommonBoardId
		INTEGER,
	s3CommonBoardHwVer
		INTEGER,
	s3CommonBoardStatus
		INTEGER,
	s3CommonBoardReset
		INTEGER,
	s3CommonBoardPartStatus
		INTEGER,
	s3CommonBoardNmCntlStatus
		INTEGER,
	s3CommonBoardPsStatus
		INTEGER
}

s3CommonBoardIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"A unique value for each board. Its value ranges between 1 and
		12. The value for each board must remain constant at least from
		one re-initialization of the entity's network management system
		to the next re-initialization."
	::= { s3CommonBoardEntry 1 }

s3CommonBoardId OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"ID of the board."
	::= { s3CommonBoardEntry 2 }

s3CommonBoardHwVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The hardware revision of the board.  0=Rev. A, 1=Rev. B, etc."
	::= { s3CommonBoardEntry 3 }

s3CommonBoardStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		ok(1),		-- good status
		fail(2)		-- bad status
		}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates the operational status of the board."
	::= { s3CommonBoardEntry 4 }

s3CommonBoardReset OBJECT-TYPE
	SYNTAX	INTEGER {
		noReset(1),	-- not resetting
		reset(2)	-- resetting
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This indicates the reset state of the board.  Writing with 
		the value reset (2) will reset the board."
	::= { s3CommonBoardEntry 5 }

s3CommonBoardPartStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		enabled(1),	-- board enabled
		partition(2)	-- board partitioned indefinitely
		}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Tells whether the board is partitioned or enabled.  Writing 
		with the value partition(2) will partition the board 
		indefinitely and writing with the value enabled(1) will enable
		the board. Boards cannot be partitioned in the 2810 
		concentrator.  The 2810 agent will implement this object as 
		read-only."
	::= { s3CommonBoardEntry 6 }

s3CommonBoardNmCntlStatus OBJECT-TYPE
	SYNTAX	INTEGER {
			notNmControl(1),	-- board not under NM control
			nmControl(2)		-- board under NM control
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Tells whether the board is under network management control.
  		The value nmControl(2) indicates that the board or one or more
 		ports are being controlled by network management.  This means 
		that the board or one or more ports are partitioned via a 
		network manager."
	::= { s3CommonBoardEntry 7 }

s3CommonBoardPsStatus OBJECT-TYPE
	SYNTAX	INTEGER {
			ok(1),		-- good status
			fail(2)		-- bad status
			}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates the operational status of the board power 
		supply.  A fail(2) indicates that one of the power supplies 
		on the board has failed."
	::= { s3CommonBoardEntry 8 }


-- Packed Slot Configuration Table


s3SlotConfigOctetString OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(12..144))
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Packed octet string for the slot configuration table."
	::= { s3000Chassis 9 }



-- SECTION 3: Agent Configuration

-- Agent Software Group


-- Implementation of this group is mandatory for all SynOptics Series 3000 
-- agents


s3AgentType OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),	-- none of the following
		m3313(2),	-- AUI Ethernet NMM w/ RS232 port
		m3313M(3),	-- AUI Enet NMM w/ RS232 port + modem
		m3314-ST(4),	-- FOIRL Ethernet NMM w/ RS232
		m3314M-ST(5),	-- FOIRL Ethernet NMM w/ RS232 + modem
		m2310(6),	-- Model 2310
		m3512(7),	-- T.R. NMM w/ STP ring in/ring out
		m3514(8),	-- T.R. NMM w/ FOIRL ring in/ring out
		m332X(9),	-- Low Speed Local Bridge
		m3356(10),	-- Ethernet Remote Bridge
		m332XS(11)	-- High Speed Local Bridge
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The 3000 series agent's Module type."
	::= {s3AgentSw  1 }

s3AgentFwVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The agent's module firmware version 0=Rev A,1=Rev B,etc."
	::= { s3AgentSw 2 }

s3AgentSwMajorVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The network management module major software version number 
		(i.e. represents major.minor or 3.0).  Object is in decimal."
	::= { s3AgentSw 3 }

s3AgentSwMinorVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The network management module minor software version number 
		(i.e. represents major.minor or 3.0).  Object is in decimal."
	::= { s3AgentSw 4 }

s3AgentBootProtocol OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),	-- boot protocol not listed here
		bootp-tftp(2),
		tftp-only(3),
		ieee802-1e(4),
		proprietary(5),	-- supported proprietary boot protocol
		dll-download(6)	-- direct async binary download (Retix)
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Boot protocol used to load the module with its software."
	::= {s3AgentSw 5 }

s3AgentBootFile OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..64))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The name of the boot file that is sent to the file server 
		during boot time. The actual boot protocol used to retrieve the
		file is determined by s3AgentBootProtocol. This parameter will
 		not take effect until written into EEPROM (s3AgentWriteEeprom)
 		and a reset (s3AgentReset) is issued. This parameter is used 
		only if the s3AgentBootMode is set to use EEPROM."
	::= { s3AgentSw 6 }

s3AgentAuthTrap OBJECT-TYPE
	SYNTAX	INTEGER {
		disable(1),	-- disable authentication traps
		enable(2)	-- enable authentication traps
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Enable or disable the use of authentication error trap 
		generation. This parameter will take effect only after a 
		restart (s3AgentRestart) is issued.  This parameter will not 
		survive a reset (s3AgentReset) unless the specific NMM 
		configuration file is updated to reflect the change."
	::= { s3AgentSw 7 }

s3AgentLocation OBJECT-TYPE
	SYNTAX	DisplayString (SIZE(0..64))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This is a informational string that could be used to show the
		physical location (i.e. area) of the NMM or concentrator. This
 		parameter will take effect only after a restart 
		(s3AgentRestart) is issued.  This parameter will not survive a
 		reset (s3AgentReset) unless the specific NMM configuration file
 		is updated to reflect the change."
	::= { s3AgentSw 8 }

s3AgentMibLevel OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Used to determine current MIB release supported by agent.  The
		encoding of this object is of the following form: xyy, where x
		is the major version number and yy is the minor version number.
  	        Thus, version 3.0 would be represented as 300,  version 3.01 
		would be 301 and 3.1 would be 310.  Object is in decimal."
	::= { s3AgentSw 9 }

s3AgentFeatureLevel OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Used to determine feature level of the agent.  The encoding 
		of this object is of the following form: xyy, where x is the 
		major version number and yy is the minor version number.  Thus,
  	        feature level version 1.0 would be represented as 100, version
 		1.01 would be 101 and 1.1 would be 110. Object is in decimal."
	::= { s3AgentSw 10 }


s3AgentMySlotId OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Slot where this agent currently resides.  If hardware is 
		unable to determine then a 0 should be returned."
	::= { s3AgentSw 11 }


-- Agent Network Protocol Group


-- Implementation of this group is mandatory for all SynOptics Series 3000 
-- agents.


s3AgentIpAddr OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The network management module's administrative IP address.  
		The current operational IP address can be obtained by the 
		ipAdEntAddr entry in the ipAddrTable. This parameter will take
 		effect only after a restart (s3AgentRestart) is issued.  This 
		parameter will not survive a reset (s3AgentReset) unless it is
 		written into EEPROM (s3AgentWriteEeprom).  This parameter is 
		used only if the s3AgentBootMode is set to use EEPROM."
	::= { s3AgentIpProtocol 1 }

s3AgentNetMask OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The network management module's administrative subnet mask.  
		The current operational subnet mask can be obtained by the 
		ipAdEntNetMask entry in the ipAddrTable. This parameter will `
		take effect only after a restart (s3AgentRestart) is issued. 
		This parameter will not survive a reset (s3AgentReset) unless 
		it is written into EEPROM (s3AgentWriteEeprom).  This parameter
		is used only if the agentBootMode is set to use EEPROM.
		NOTE:  The Model 331x (3313, 3313M, 3314-ST, 3314M-ST)
		Ethernet NMM agents do not store this parameter in EEPROM, 
		so for these agents the subnet mask configuration must be
		downloaded in the configuration file."
	::= { s3AgentIpProtocol 2 }

s3AgentDefaultGateway OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The network management module's administrative default 
		gateway IP address.  The current operational default gateway's
 		IP address can be obtained from the ipRoutingTable. This 
		parameter will take effect only after a restart 
		(s3AgentRestart) is issued.  This parameter will not survive a
 		reset (s3AgentReset) unless it is written into EEPROM 
		(s3AgentWriteEeprom).  This parameter is used only if the 
		agentBootMode is set to use EEPROM."
	::= { s3AgentIpProtocol 3 }

s3AgentBootServerAddr OBJECT-TYPE
	SYNTAX	IpAddress
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The IP address to which the requests for boot files are sent.
 		The protocol used to retrieve the boot files is determined by 
		object s3AgentBootProtocol. This parameter will not take effect
 		until until written into EEPROM (s3AgentWriteEeprom) and a 
		reset (s3AgentReset) is issued. This parameter is used only if
 		the s3AgentBootMode is set to use EEPROM."
	::= { s3AgentIpProtocol 4 }



-- Agent Trap Receiver Table


-- Implementation of this group is mandatory for all SynOptics Series 3000 agents


s3AgentTrapReceiverTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF S3AgentTrapReceiverEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"Table containing list of NMS's that are to receive traps 
		generated by this NMM."
	::= { s3SnmpAgent 3 }

s3AgentTrapReceiverEntry OBJECT-TYPE
	SYNTAX	S3AgentTrapReceiverEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A destination address and community string to a particular 
		trap server, along with a trap filter and entry aging 
		capability."
	INDEX	{ s3AgentTrapRcvrNetAddress }
	::= { s3AgentTrapReceiverTable 1 }

S3AgentTrapReceiverEntry ::= SEQUENCE {
	s3AgentTrapRcvrStatus
		INTEGER,
	s3AgentTrapRcvrNetAddress
		OCTET STRING,
	s3AgentTrapRcvrComm
		OCTET STRING,
	s3AgentTrapRcvrAgeTime
		TimeTicks
}

s3AgentTrapRcvrStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		other (1),		-- none of the following
		valid (2),		-- a valid address
		invalid (3)		-- an invalid address
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Setting this object to the value invalid(3) has the effect 
		of invalidating the corresponding entry in the 
		s3AgentTrapReceiverTable. That is, it effectively disassociates
 		the address identified with the entry by removing the entry 
		from the table. On a read the value of valid(2) should be 
		returned if the entry contains a valid record, or invalid(3) 
		should be returned if the entry contains an invalid record."
	::= { s3AgentTrapReceiverEntry 1 }

s3AgentTrapRcvrNetAddress OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(4))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"IP address for trap server that is to receive the trap."
	::= { s3AgentTrapReceiverEntry  2 }

s3AgentTrapRcvrComm OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(0..20))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Community string used for traps sent to this trap receiver."
	::= { s3AgentTrapReceiverEntry  3 }

s3AgentTrapRcvrAgeTime OBJECT-TYPE
	SYNTAX	TimeTicks
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This is the time interval used to age entries out of the trap
 		receiver table.  The default value if not specified will be 0,
 		or infinite, never to be aged out."
	::= { s3AgentTrapReceiverEntry  4 }



-- Agent Hardware Group


-- Implementation of this group is mandatory for all SynOptics Series 3000 
-- agents.


				
s3AgentStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		offline(1),	-- the agent is offline
		online(2)	-- the agent is online
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the NMM is online(2) and operating, or 
		offline(1) (ie: not connected to the concentrator backplane)."
	::= { s3AgentHw 1 }

s3AgentMdaHwVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The network management module's MDA hardware version number 
		(0=Rev. A, 1=Rev. B, etc.)."
	::= { s3AgentHw 2 }

s3AgentMode OBJECT-TYPE
	SYNTAX	INTEGER {
		primary(1),	-- in primary mode
		secondary(2),	-- in secondary mode
		other(3)	-- the other values do not apply
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the NMM is operating in primary(1) or 
		secondary(2) mode."
	::= { s3AgentHw 3 }

s3AgentReset OBJECT-TYPE
	SYNTAX	INTEGER {
		noReset(1),	-- not resetting
		reset(2)	-- reset
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Network management module reset status.  Writing a reset(2) 
		to this object will reset the NMM (stop refreshing the watch 
		dog) and perform a download and restart.  This process takes 
		about 45 seconds."
	::= { s3AgentHw 4 }

s3AgentRestart OBJECT-TYPE
	SYNTAX	INTEGER {
		noRestart(1),	-- not restarting
		restart(2)	-- restart
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Network management module restart status.  Writing a 
		restart(2) to this object will restart the NMM.  This 
		initializes all the counters, re-reads the EEPROM data 
		structure and starts executing from the beginning of the code."
	::= { s3AgentHw 5 }

s3AgentBootMode OBJECT-TYPE
	SYNTAX	INTEGER {
		eeprom(1),	-- get boot info from eeprom
		other(2)	-- or from a boot protocol
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"The method for obtaining boot parameter information.
		This parameter will not take effect until written into EEPROM 
		(s3AgentWriteEeprom) and a reset (s3AgentReset) is issued."
	::= { s3AgentHw 6 }

s3AgentWriteEeprom OBJECT-TYPE
	SYNTAX	INTEGER {
		noWriteEeprom(1),	-- not writing EEPROM 
		writeEeprom(2)		-- write EEPROM
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Network management module EEPROM write status.  Writing a 
		(2) to this object will write the contents of current EEPROM 
		data structure in the EEPROM."
	::= { s3AgentHw 7 }

s3AgentBaudRate OBJECT-TYPE
	SYNTAX	Gauge
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Specifies the baud rate in bits per second of either the 
		internal modem or the RS-232 port. This parameter will take 
		effect only after a restart (s3AgentRestart) is issued.  This 
		parameter will not survive a reset (s3AgentReset) unless the 
		specific NMM configuration file is updated to reflect the 
		change."
	::= { s3AgentHw 8 }

s3AgentInitString OBJECT-TYPE
	SYNTAX	OCTET STRING (SIZE(0..64))
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This is the initialization string used to establish the 
		out-of-band connection. (i.e. could contain the string 
		ATDT,415-960-1100 for an internal or external modem). This 
		parameter will take effect only after a restart 
		(s3AgentRestart) is issued.  This parameter will not survive 
		a reset (s3AgentReset) unless the specific NMM configuration
 		file is updated to reflect the change."
	::= { s3AgentHw 9 }


-- Agent Local Image Group


-- This group is mandatory for agents with image code stored in local EPROM.
-- Other agents should return NoSuch if asked for any of the objects in this group.


s3LocImageValid OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),		-- unknown status
		localImageValid(2),	-- local image is valid
		localImageInvalid(3)	-- local image is invalid
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the agent has a valid local code 
		image on board. An EPROM checksum failure would cause the 
		agent to return localImageInvalid(3)."
	::= { s3AgentLocImage 1 }

s3LocImageMajorVersion OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The major software version number of the locally-stored image.
  		 This object applies only to agents with valid local image.  
		 Other agents should return zero."
	::= { s3AgentLocImage 2 }

s3LocImageMinorVersion OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"The minor software version number of the locally-stored image.
  		This object applies only to agents with valid local image.  
		Other agents should return zero."
	::= { s3AgentLocImage 3 }

s3LocImageLoadMode OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),		-- unknown status
		remoteBoot(2),		-- use net, not local image
		localBoot(3),		-- boot from local image, not net
		localAsBackup(4)	-- try net, if fails use local
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the agent should get code from the 
		network, use a local image, or try the network first and then 
		fall back to local image if the network boot fails.  The 
		localBoot and localAsBackup values apply only to agents with 
		local load option."
	::= { s3AgentLocImage 4 }

s3LocImageActualSource OBJECT-TYPE
	SYNTAX	INTEGER {
		other(1),		-- unknown status
		remoteImage(2),		-- downloaded code from network
		localImage(3)		-- loaded code from local EPROM
	}
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This indicates whether the agent loaded code from the network
 		or used a local image.  When the the ImageLoadMode is 
		localAsBackup, this variable indicates whether the network 
		load was successful."
	::= { s3AgentLocImage 5 }


END


-- file:  enet3.3-10.25.91

SYNOPTICS-ETHERNET-MIB

-- Ethernet MIB Release 3.3
-- DRAFT Revision 10/25/91
-- Printed 10/25/91

-- Copyright 1991 SynOptics Communications, Inc.  All Rights
-- Reserved.  Reproduction of this document is authorized on
-- condition that the foregoing copyright notice is included.
-- This SynOptics SNMP Management Information Base Specification
-- (Specification) embodies SynOptics' confidential and
-- proprietary intellectual property.  SynOptics retains all
-- title and ownership in the Specification, including any
-- revisions.  
--
-- It is SynOptics intent to encourage the widespread use of
-- this Specification in connection with the management of
-- SynOptics products. SynOptics grants vendors, end-users,
-- and other interested parties a non-exclusive license to
-- use this Specification in connection with the management
-- of SynOptics products.
--
-- This Specification is supplied "AS IS," and SynOptics makes
-- no warranty, either express or implied, as to the use,
-- operation, condition, or performance of the Specification.


DEFINITIONS ::= BEGIN

-- SECTION 1: Top Level Definitions

-- Imports

IMPORTS
	Counter, IpAddress, Gauge	FROM RFC1155-SMI
	DisplayString			FROM RFC1213-MIB
	OBJECT-TYPE			FROM RFC-1212
	s3000Ethernet			FROM SYNOPTICS-COMMON-MIB;


-- Groups

s3000EnetConcentrator	OBJECT IDENTIFIER ::= { s3000Ethernet 1 }
s3000EnetBoard		OBJECT IDENTIFIER ::= { s3000Ethernet 2 }
s3000EnetLocBridge	OBJECT IDENTIFIER ::= { s3000EnetBoard 2 }
s3000EnetRemBridge	OBJECT IDENTIFIER ::= { s3000EnetBoard 3 }
s3000EnetRouter		OBJECT IDENTIFIER ::= { s3000EnetBoard 4 }
s3000EnetPort 		OBJECT IDENTIFIER ::= { s3000Ethernet 3 }
s3000EnetNmm		OBJECT IDENTIFIER ::= { s3000Ethernet 4 }



-- SECTION 2: Ethernet Status and Statistics Group

-- The Ethernet Status and Statistics group consists of Concentrator Group,
-- Board Table, Local Bridge Board Table, Local Bridge Port Table,
-- Remote Bridge Board Table, Remote Bridge Port Table, Router Board
-- Table, and Port Table.


-- Concentrator Group

-- Implementation of this group is mandatory for all 
-- SynOptics Series 3000 Ethernet NMM agents

s3EnetConcRetimingStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		off(1),		-- retiming off
		on(2)		-- retiming on
	}
	ACCESS	read-write
	STATUS	mandatory
	DESCRIPTION
		"Does this concentrator have retiming turned on.  Writing a 1 
		will turn off retiming and writing a 2 will turn on retiming. 
 		This will change the active state of retiming but will change 
		the value in EEPROM only when agentWriteEeprom is set.The 
		factory default of this state is on. Retiming cannot be 
		disabled in the 2810 concentrator.  The 2810 agent will
		implement this object as read-only."
	::= { s3000EnetConcentrator 1 }

s3EnetConcFrmsRxOk OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of frames that are successfully 
		received by the concentrator. This does not include frames 
		received with a frame-too-long, runt, FCS, or alignment errors.
		This counter includes broadcast and multicast frames that are 
		received."
	::= { s3000EnetConcentrator 2 }

s3EnetConcOctetsRxOk OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"Contains a count of data and padding octets in frames that 
		are successfully received by the concentrator.  This does not 
		include frames received with a frame-too-long, runt, FCS, or 
		alignment errors. This counter includes octets in broadcast 
		and multicast frames that are received. This counter does not 
		include the octets in the address, length/type and CRC fields."
	::= { s3000EnetConcentrator 3 }

s3EnetConcMcastFrmsRxOk OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of frames that are successfully 
		received by the concentrator and are directed to an active 
		non-broadcast group address. This does not include frames 
		received with a frame-too-long, runt, FCS, or alignment errors.
		Only frames that are for a multicast address that this 
		interface is receiving are counted.  Broadcast packets are 
		not included."
	::= { s3000EnetConcentrator 4 }

s3EnetConcBcastFrmsRxOk OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of frames that are successfully received
		by the concentrator and are directed to the broadcast group 
		address. This does not include frames received with a 
		frame-too-long, runt, FCS, or alignment errors. Multicast 
		packets are not included."
	::= { s3000EnetConcentrator 5 }

s3EnetConcColls OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of the collision flags at the 
		concentrator level."
	::= { s3000EnetConcentrator 6 }


-- MAC Receive Error Statistics

-- A hierarchical order has been established for those objects listed below 
-- such that when multiple error conditions can be associated with one frame, 
-- only one condition is counted.  This hierarchy, in descending order is:
--	frame too long
--	runt frames
--	fragments
--	alignment error
--	frame check error


s3EnetConcTooLongErrors OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of frames that are received by the 
		concentrator and exceed the maximum permitted frame size.  
		This counter is incremented when the frameTooLong error is 
		detected."
	::= { s3000EnetConcentrator 7 }

s3EnetConcRuntErrors OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of frames received by the concentrator 
		that are less than the minimum permitted frame size and have a
 		good FCS."
	::= { s3000EnetConcentrator 8 }

s3EnetConcFragErrors OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of frames received by the concentrator 
		that are less than the minimum permitted frame size and have a
 		bad FCS or alignment error."
	::= { s3000EnetConcentrator 9 }

s3EnetConcAlignErrors OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of frames received by the concentrator 
		that are not an integral number of octets in length and do not
 		pass the FCS check.  This counter is incremented when the 
		alignment Error status is detected."
	::= { s3000EnetConcentrator 10 }

s3EnetConcFcsErrors OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a count of frames received by the concentrator 
		that are an integral number of octets in length that do not 
		pass the FCS check.  This counter is incremented when the 
		frame Check Error status is detected."
	::= { s3000EnetConcentrator 11 }

s3EnetConcLateCollErrors OBJECT-TYPE
	SYNTAX	Counter
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"This contains a total concentrator count of the late 
		collision flags."
	::= { s3000EnetConcentrator 12 }


-- Board Table


s3EnetBoardTable OBJECT-TYPE
	SYNTAX	SEQUENCE OF S3EnetBoardEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A table of board-related objects.  The number of entries is 
		given by the number of Ethernet host module and network 
		management module boards that are contained in the 
		Concentrator Slot Configuration Table."
	::= { s3000EnetBoard 1 }

s3EnetBoardEntry OBJECT-TYPE
	SYNTAX	S3EnetBoardEntry
	ACCESS	not-accessible
	STATUS	mandatory
	DESCRIPTION
		"A table containing objects about Ethernet boards which are 
		currently plugged into the 3000 chassis."
	INDEX	{ s3EnetBoardIndex }
	::= { s3EnetBoardTable 1 }

S3EnetBoardEntry ::= SEQUENCE {
	s3EnetBoardIndex
		INTEGER,
-- the bounded below objects are deprecated
	s3EnetBoardType
		INTEGER,
	s3EnetBoardHwVer
		INTEGER,
	s3EnetBoardStatus
		INTEGER,
	s3EnetBoardReset
		INTEGER,
	s3EnetBoardPartStatus
		INTEGER,
	s3EnetBoardNmCntlStatus
		INTEGER,
	s3EnetBoardPsStatus
		INTEGER,
-- the bounded above objects are deprecated
	s3EnetBoardFrmsRxOk
		Counter,
	s3EnetBoardOctetsRxOk
		Counter,
	s3EnetBoardMcastFrmsRxOk
		Counter,
	s3EnetBoardBcastFrmsRxOk
		Counter,
	s3EnetBoardColls
		Counter,
	s3EnetBoardTooLongErrors
		Counter,
	s3EnetBoardRuntErrors
		Counter,
	s3EnetBoardAlignErrors
		Counter,
	s3EnetBoardFcsErrors
		Counter,
	s3EnetBoardLateCollErrors
		Counter
}

s3EnetBoardIndex OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	mandatory
	DESCRIPTION
		"A unique value for each board.  Its value ranges between 1 
		and 12. The value for each board must remain constant at least
 		from one re-initialization of the entity's network management 
		system to the next re-initialization."
	::= { s3EnetBoardEntry 1 }

s3EnetBoardType OBJECT-TYPE
	SYNTAX	INTEGER {
		empty(1),		-- nothing installed
		other(2),		-- none of the following
		m3302(3),		-- Model 3302
		m3304-ST(4),		-- Model 3304-ST
		m3305(5),		-- Model 3305
		m3308(6),		-- Model 3308
		m3313(7),		-- Model 3313
		m3313M(8),		-- Model 3313M
		m3314-ST(9),		-- Model 3314
		m3314M-ST(10),		-- Model 3314M-ST
		m3323(11),		-- Model 3323
		m3324-ST(12),		-- Model 3324-ST
		m3301(16),		-- Model 3301
		m3307(17),		-- Model 3307
		m3356(18),		-- Model 3356
		m3383(24),		-- Model 3383
		m3384(25),		-- Model 3384
		m331x(26),		-- unknown 331x
		m3386(32),		-- Model 3386
		m3394(33),		-- Model 3394
		m3395(34),		-- Model 3395
		m3323S(35),		-- Model 3323S
		m3324S-ST(36),		-- Model 3324S-ST
		m3307A(37),		-- Model 3307A
		m3308A(38)		-- Model 3308A
	}
	ACCESS	read-only
	STATUS	deprecated
	DESCRIPTION
		"See s3SlotModuleType"
	::= { s3EnetBoardEntry 2 }

s3EnetBoardHwVer OBJECT-TYPE
	SYNTAX	INTEGER
	ACCESS	read-only
	STATUS	deprecated
	DESCRIPTION
		"See s3CommonBoardHwVer"
	::= { s3EnetBoardEntry 3 }

s3EnetBoardStatus OBJECT-TYPE
	SYNTAX	INTEGER {
		ok(1),		-- good status
		fail(2)		-- bad status
	}
	ACCESS	read-only
	STATUS	deprecated
	DESCRIPTION
		"See s3CommonBoardStatus"
	::= { s3EnetBoardEntry 4 }

s3EnetBoardReset OBJECT-TYPE
	SYNTAX	INTEGER {
		noReset(1),	-- not resetting
		reset(2)	-- resetting
	}
	ACCESS	read-write
	STATUS	deprecated
	DESCRIPTION
		"See s3CommonBoardReset"
	::= { s3EnetBoardEntry 5 }

s3EnetBoardPartStatus OBJECT-TYPE