NETEXEC-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString
FROM RFC1213-MIB
Counter, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215;
internet OBJECT IDENTIFIER ::= { iso(1) org(3) dod(6) 1 }
private OBJECT IDENTIFIER ::= { internet 4 }
enterprises OBJECT IDENTIFIER ::= { private 1 }
tylink OBJECT IDENTIFIER ::= { enterprises 466 }
netexec OBJECT IDENTIFIER ::= { tylink 6 }
dsucsu OBJECT IDENTIFIER ::= { netexec 1 }
tyview OBJECT IDENTIFIER ::= { netexec 2 }
dsucsuSysTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuSysEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of system level attributes describing the
addressed node."
::= { dsucsu 1 }
dsucsuSysEntry OBJECT-TYPE
SYNTAX DsucsuSysEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System Object for a DSU/CSU"
INDEX { dsucsuSysSlot, dsucsuSysNode }
::= { dsucsuSysTable 1 }
DsucsuSysEntry ::=
SEQUENCE
{
dsucsuSysSlot
INTEGER (1..16),
dsucsuSysNode
INTEGER (1..255),
dsucsuSysName
DisplayString (SIZE (0..8)),
dsucsuSysType
INTEGER,
dsucsuSysSoftRev
DisplayString (SIZE (0..10)),
dsucsuSysHardRev
DisplayString (SIZE (0..1)),
dsucsuSysNumChan
INTEGER (0..4)
}
dsucsuSysSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuSysEntry 1 }
dsucsuSysNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuSysEntry 2 }
dsucsuSysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique name of the node accessed"
::= { dsucsuSysEntry 3 }
dsucsuSysType OBJECT-TYPE
SYNTAX INTEGER
{
unknown (1),
ons400 (2),
fns400 (3),
ons400e (4),
sns400 (5),
ons1000 (6),
ons232sp (7),
ons271sp (8),
ons200 (9),
ons400n (10),
sns256 (11),
sns4000 (12),
sns1000 (13),
ty3410 (14),
ty3210 (15),
ons1010n (16),
ty3250 (17),
ty3000n (18),
ty3450n (19)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A desciption of the system model: ie.
ONS400, FNS400, ONS1000X, BLACK BOX FT1-4"
::= { dsucsuSysEntry 4 }
dsucsuSysSoftRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the Software Revision of the accessed
node."
::= { dsucsuSysEntry 5 }
dsucsuSysHardRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..1))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the Hardware Revision of the accessed
node."
::= { dsucsuSysEntry 6 }
dsucsuSysNumChan OBJECT-TYPE
SYNTAX INTEGER (0..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of channels that are installed on the
node."
::= { dsucsuSysEntry 7 }
dsucsuCfgNetTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgNetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Network Line Configuration"
::= { dsucsu 2 }
dsucsuCfgNetEntry OBJECT-TYPE
SYNTAX DsucsuCfgNetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Configuration Object for a DSU/CSU"
INDEX { dsucsuCfgNetSlot, dsucsuCfgNetNode, dsucsuCfgNetIndex }
::= { dsucsuCfgNetTable 1 }
DsucsuCfgNetEntry ::=
SEQUENCE
{
dsucsuCfgNetSlot
INTEGER (1..16),
dsucsuCfgNetNode
INTEGER (1..255),
dsucsuCfgNetIndex
INTEGER (1..2),
dsucsuCfgNetInterface
INTEGER,
dsucsuCfgNetType
INTEGER,
dsucsuCfgNetCoding
INTEGER,
dsucsuCfgNetClockSource
INTEGER,
dsucsuCfgNetCsuEnable
INTEGER,
dsucsuCfgNetCsuLBO
INTEGER,
dsucsuCfgNetCsuDensity
INTEGER,
dsucsuCfgNetRateMultiples
INTEGER,
dsucsuCfgNetOutputPulse
INTEGER,
dsucsuCfgNetTs0
INTEGER,
dsucsuCfgNetTs16
INTEGER
}
dsucsuCfgNetSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The NEST slot to which the TyLink card is attached."
::= { dsucsuCfgNetEntry 1 }
dsucsuCfgNetNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgNetEntry 2 }
dsucsuCfgNetIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network index."
::= { dsucsuCfgNetEntry 3 }
dsucsuCfgNetInterface OBJECT-TYPE
SYNTAX INTEGER
{
network (1),
dsx-1 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The interface type for 3000N. For a T1 line,
NETWORK or DSX-1 is valid."
::= { dsucsuCfgNetEntry 4 }
dsucsuCfgNetType OBJECT-TYPE
SYNTAX INTEGER
{
d4 (1),
esf-54016 (2),
esf-ansi (3),
nsms (4),
cept-2048 (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The aggregate line type."
::= { dsucsuCfgNetEntry 5 }
dsucsuCfgNetCoding OBJECT-TYPE
SYNTAX INTEGER
{
ami (1),
b8zs (2),
hdb3 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The encoding scheme for the line. For a T1 line,
AMI and B8ZS are valid. For an E1 line, AMI and
HDB3 are valid."
::= { dsucsuCfgNetEntry 6 }
dsucsuCfgNetClockSource OBJECT-TYPE
SYNTAX INTEGER
{
internal (1),
loop (2),
external-ch1 (3),
external-ch3 (4),
station-clock (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The aggregate timing for the addressed node."
::= { dsucsuCfgNetEntry 7 }
dsucsuCfgNetCsuEnable OBJECT-TYPE
SYNTAX INTEGER
{
dsx1 (1),
csu (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable Internal CSU."
::= { dsucsuCfgNetEntry 8 }
dsucsuCfgNetCsuLBO OBJECT-TYPE
SYNTAX INTEGER
{
db-0 (1),
db-7-5 (2),
db-15 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The setting of the Line Buildout switch. Setting
must be db_0 if network interface is DSX-1."
::= { dsucsuCfgNetEntry 9 }
dsucsuCfgNetCsuDensity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
d-1-in-8 (2),
d-1-in-16 (3),
d-1-in-64 (4),
d-12pt5-percent (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The setting of the one stuffing option. Inserts
a 1 into the 8th, 16th, or 64th bit position
(depending on the selection) if the previous 7
bits were 0's."
::= { dsucsuCfgNetEntry 10 }
dsucsuCfgNetRateMultiples OBJECT-TYPE
SYNTAX INTEGER
{
nx56 (1),
nx64 (2),
extended-mixed (3),
all-rates (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The channel rate multiples for each of the ports."
::= { dsucsuCfgNetEntry 11 }
dsucsuCfgNetOutputPulse OBJECT-TYPE
SYNTAX INTEGER
{
pulse-0-133-ft (1),
pulse-133-266-ft (2),
pulse-266-399-ft (3),
pulse-399-533-ft (4),
pulse-533-655-ft (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The distance to the CSU in feet."
::= { dsucsuCfgNetEntry 12 }
dsucsuCfgNetTs0 OBJECT-TYPE
SYNTAX INTEGER
{
crc4-enable (1),
crc4-disable (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The E1 Timeslot 0 value."
::= { dsucsuCfgNetEntry 13 }
dsucsuCfgNetTs16 OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
multifr-align (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The E1 Timeslot 16 value. Valid values are
data and multiframe alignment."
::= { dsucsuCfgNetEntry 14 }
dsucsuCfgDteChanTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgDteChanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Channel Configuration"
::= { dsucsu 4 }
dsucsuCfgDteChanEntry OBJECT-TYPE
SYNTAX DsucsuCfgDteChanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DTE Channel Configuration Object for a DSU/CSU"
INDEX { dsucsuCfgDteChanSlot, dsucsuCfgDteChanNode, dsucsuCfgDteChanIndex }
::= { dsucsuCfgDteChanTable 1 }
DsucsuCfgDteChanEntry ::=
SEQUENCE
{
dsucsuCfgDteChanSlot
INTEGER (1..16),
dsucsuCfgDteChanNode
INTEGER (1..255),
dsucsuCfgDteChanIndex
INTEGER (1..4),
dsucsuCfgDteChanType
INTEGER,
dsucsuCfgDteChanRate
INTEGER,
dsucsuCfgDteChanEncoding
INTEGER,
dsucsuCfgDteChanStartDs0
INTEGER,
dsucsuCfgDteChanCtrlSignal
INTEGER,
dsucsuCfgDteChanTiming
INTEGER,
dsucsuCfgDteChanClockInvert
INTEGER,
dsucsuCfgDteChanDataInvert
INTEGER
}
dsucsuCfgDteChanSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgDteChanEntry 1 }
dsucsuCfgDteChanNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgDteChanEntry 2 }
dsucsuCfgDteChanIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The channel index."
::= { dsucsuCfgDteChanEntry 3 }
dsucsuCfgDteChanType OBJECT-TYPE
SYNTAX INTEGER
{
rs232 (1),
v35 (2),
rs449 (3),
none (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Dte channel type."
::= { dsucsuCfgDteChanEntry 4 }
dsucsuCfgDteChanRate OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Data rate in kilobits per second. The rate is
dependent on the setting of the Aggregate DTE
channel multiples."
::= { dsucsuCfgDteChanEntry 5 }
dsucsuCfgDteChanEncoding OBJECT-TYPE
SYNTAX INTEGER
{
b7s (1),
alt (2),
clr (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Channel encoding."
::= { dsucsuCfgDteChanEntry 6 }
dsucsuCfgDteChanStartDs0 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The starting DS0 for the addressed channel's data."
::= { dsucsuCfgDteChanEntry 7 }
dsucsuCfgDteChanCtrlSignal OBJECT-TYPE
SYNTAX INTEGER
{
rts-on (1),
rts-switch (2),
cts-on (3),
cts-auto (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control signal state."
::= { dsucsuCfgDteChanEntry 8 }
dsucsuCfgDteChanTiming OBJECT-TYPE
SYNTAX INTEGER
{
loop1 (1),
loop2 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DTE channel Timing."
::= { dsucsuCfgDteChanEntry 9 }
dsucsuCfgDteChanClockInvert OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DTE channel Clock Invert setting."
::= { dsucsuCfgDteChanEntry 10 }
dsucsuCfgDteChanDataInvert OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DTE channel Data Invert setting."
::= { dsucsuCfgDteChanEntry 11 }
dsucsuCfgFrmChanTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgFrmChanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Framed Channel Configuration"
::= { dsucsu 5 }
dsucsuCfgFrmChanEntry OBJECT-TYPE
SYNTAX DsucsuCfgFrmChanEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Framed Channel Configuration Object for a DSU/CSU"
INDEX { dsucsuCfgFrmChanSlot, dsucsuCfgFrmChanNode, dsucsuCfgFrmChanIndex }
::= { dsucsuCfgFrmChanTable 1 }
DsucsuCfgFrmChanEntry ::=
SEQUENCE
{
dsucsuCfgFrmChanSlot
INTEGER (1..16),
dsucsuCfgFrmChanNode
INTEGER (1..255),
dsucsuCfgFrmChanIndex
INTEGER (1..4),
dsucsuCfgFrmChanType
INTEGER,
dsucsuCfgFrmChanNumDs0
INTEGER,
dsucsuCfgFrmChanEncoding
INTEGER,
dsucsuCfgFrmChanStartDs0
INTEGER,
dsucsuCfgFrmChanDteStartDs0
INTEGER,
dsucsuCfgFrmChanMapping
INTEGER,
dsucsuCfgFrmChanDs0Type
INTEGER,
dsucsuCfgFrmChanFrameType
INTEGER,
dsucsuCfgFrmChanOutputPulse
INTEGER,
dsucsuCfgFrmChanNetMapping
INTEGER
}
dsucsuCfgFrmChanSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgFrmChanEntry 1 }
dsucsuCfgFrmChanNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgFrmChanEntry 2 }
dsucsuCfgFrmChanIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The channel index."
::= { dsucsuCfgFrmChanEntry 3 }
dsucsuCfgFrmChanType OBJECT-TYPE
SYNTAX INTEGER
{
pbx (1),
none (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The framed channel type."
::= { dsucsuCfgFrmChanEntry 4 }
dsucsuCfgFrmChanNumDs0 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of DS0's on the network side."
::= { dsucsuCfgFrmChanEntry 5 }
dsucsuCfgFrmChanEncoding OBJECT-TYPE
SYNTAX INTEGER
{
ami (1),
b8zs (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The channel line code."
::= { dsucsuCfgFrmChanEntry 6 }
dsucsuCfgFrmChanStartDs0 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The starting DS0 on the network side."
::= { dsucsuCfgFrmChanEntry 7 }
dsucsuCfgFrmChanDteStartDs0 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The starting DS0 on the framed channel."
::= { dsucsuCfgFrmChanEntry 8 }
dsucsuCfgFrmChanMapping OBJECT-TYPE
SYNTAX INTEGER
{
ctg-ds0 (1),
alt-ds0 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Framed channel Mapping."
::= { dsucsuCfgFrmChanEntry 9 }
dsucsuCfgFrmChanDs0Type OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
voice (2),
mixed (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Framed channel DS0 Type."
::= { dsucsuCfgFrmChanEntry 10 }
dsucsuCfgFrmChanFrameType OBJECT-TYPE
SYNTAX INTEGER
{
d4 (1),
esf (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Framed channel Frame Type."
::= { dsucsuCfgFrmChanEntry 11 }
dsucsuCfgFrmChanOutputPulse OBJECT-TYPE
SYNTAX INTEGER
{
pulse-0-133-ft (1),
pulse-133-266-ft (2),
pulse-266-399-ft (3),
pulse-399-533-ft (4),
pulse-533-655-ft (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The cabling distance from the PBX to the PBX
channel port in feet."
::= { dsucsuCfgFrmChanEntry 12 }
dsucsuCfgFrmChanNetMapping OBJECT-TYPE
SYNTAX INTEGER
{
ctg-ds0 (1),
alt-ds0 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Network Ds0 Mapping."
::= { dsucsuCfgFrmChanEntry 13 }
dsucsuConfigSupTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuConfigSupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Inband Supervisory Channel Configuration"
::= { dsucsu 7 }
dsucsuConfigSupEntry OBJECT-TYPE
SYNTAX DsucsuConfigSupEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Inband Supervisory Configuration Object for a DSU/CSU"
INDEX { dsucsuConfigSupSlot, dsucsuConfigSupNode, dsucsuConfigSupIndex }
::= { dsucsuConfigSupTable 1 }
DsucsuConfigSupEntry ::=
SEQUENCE
{
dsucsuConfigSupSlot
INTEGER (1..16),
dsucsuConfigSupNode
INTEGER (1..255),
dsucsuConfigSupIndex
INTEGER (1..2),
dsucsuConfigSupDs0
INTEGER
}
dsucsuConfigSupSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuConfigSupEntry 1 }
dsucsuConfigSupNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuConfigSupEntry 2 }
dsucsuConfigSupIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Supervisory channel index.
Index 1 refers to supervisory channel A.
Index 2 refers to supervisory channel B."
::= { dsucsuConfigSupEntry 3 }
dsucsuConfigSupDs0 OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DS0 to place the Supervisory channel in."
::= { dsucsuConfigSupEntry 4 }
dsucsuCfgSupAuxTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgSupAuxEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Auxillary Supervisory Channel Configuration"
::= { dsucsu 8 }
dsucsuCfgSupAuxEntry OBJECT-TYPE
SYNTAX DsucsuCfgSupAuxEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Auxilary Supervisory Configuration Object for a DSU/CSU"
INDEX { dsucsuCfgSupAuxSlot, dsucsuCfgSupAuxNode, dsucsuCfgSupAuxIndex }
::= { dsucsuCfgSupAuxTable 1 }
DsucsuCfgSupAuxEntry ::=
SEQUENCE
{
dsucsuCfgSupAuxSlot
INTEGER (1..16),
dsucsuCfgSupAuxNode
INTEGER (1..255),
dsucsuCfgSupAuxIndex
INTEGER (1..2),
dsucsuCfgSupAuxFdl
INTEGER
}
dsucsuCfgSupAuxSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgSupAuxEntry 1 }
dsucsuCfgSupAuxNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgSupAuxEntry 2 }
dsucsuCfgSupAuxIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Auxillary Supervisory Channel Configuration Index
Index 1 refers to FDL supervisory on PORT 1.
Index 2 refers to FDL supervisory on PORT 2."
::= { dsucsuCfgSupAuxEntry 3 }
dsucsuCfgSupAuxFdl OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Places the supervisory link bits within the
Facility Data Link bits of the Extended Superframe."
::= { dsucsuCfgSupAuxEntry 4 }
dsucsuActvConfTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuActvConfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Activate a stored configuration on the selected
node."
::= { dsucsu 9 }
dsucsuActvConfEntry OBJECT-TYPE
SYNTAX DsucsuActvConfEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An activate configuration entry."
INDEX { dsucsuActvConfSlot, dsucsuActvConfNode }
::= { dsucsuActvConfTable 1 }
DsucsuActvConfEntry ::=
SEQUENCE
{
dsucsuActvConfSlot
INTEGER (1..16),
dsucsuActvConfNode
INTEGER (1..255),
dsucsuActvConfIndex
INTEGER (1..4)
}
dsucsuActvConfSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuActvConfEntry 1 }
dsucsuActvConfNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuActvConfEntry 2 }
dsucsuActvConfIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Activate one of the four stored configurations."
::= { dsucsuActvConfEntry 3 }
dsucsuEventDesTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuEventDesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of event destinations. Events or alarms
detected by a node can be reported to up to two
destinations. The operator can set or clear either
or both of these destinations via this Table."
::= { dsucsu 10 }
dsucsuEventDesEntry OBJECT-TYPE
SYNTAX DsucsuEventDesEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry in the table of event destinations."
INDEX { dsucsuEventDesSlot, dsucsuEventDesNode }
::= { dsucsuEventDesTable 1 }
DsucsuEventDesEntry ::=
SEQUENCE
{
dsucsuEventDesSlot
INTEGER (1..16),
dsucsuEventDesNode
INTEGER (1..255),
dsucsuEventNameIndx
DisplayString (SIZE (0..8)),
dsucsuEventDesName1
DisplayString (SIZE (0..8)),
dsucsuEventDesName2
DisplayString (SIZE (0..8)),
dsucsuEventClrDest
INTEGER
}
dsucsuEventDesSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuEventDesEntry 1 }
dsucsuEventDesNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuEventDesEntry 2 }
dsucsuEventNameIndx OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The unique name of the node accessed."
::= { dsucsuEventDesEntry 3 }
dsucsuEventDesName1 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the node/PC where the alarms will be
sent to."
::= { dsucsuEventDesEntry 4 }
dsucsuEventDesName2 OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the alternate node/PC where the alarms
will be sent to."
::= { dsucsuEventDesEntry 5 }
dsucsuEventClrDest OBJECT-TYPE
SYNTAX INTEGER
{
clearDest1 (1),
clearDest2 (2),
clearBothDest (3)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Clears the destination(s) for the reporting of
alarms."
::= { dsucsuEventDesEntry 6 }
dsucsuCfgMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgMaintEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Maint. Port Configuration"
::= { dsucsu 11 }
dsucsuCfgMaintEntry OBJECT-TYPE
SYNTAX DsucsuCfgMaintEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Maint. Port Configuration Object"
INDEX { dsucsuCfgMaintSlot, dsucsuCfgMaintNode }
::= { dsucsuCfgMaintTable 1 }
DsucsuCfgMaintEntry ::=
SEQUENCE
{
dsucsuCfgMaintSlot
INTEGER (1..16),
dsucsuCfgMaintNode
INTEGER (1..255),
dsucsuCfgMaintChanType
INTEGER,
dsucsuCfgMaintFlowCtrl
INTEGER,
dsucsuCfgMaintStopBits
INTEGER,
dsucsuCfgMaintParity
INTEGER,
dsucsuCfgMaintDataBits
INTEGER,
dsucsuCfgMaintBaud
INTEGER
}
dsucsuCfgMaintSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgMaintEntry 1 }
dsucsuCfgMaintNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgMaintEntry 2 }
dsucsuCfgMaintChanType OBJECT-TYPE
SYNTAX INTEGER
{
disabled (1),
nsms (2),
ascii (3),
alarm (4),
ext-event (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of data passed over the Maint. port."
::= { dsucsuCfgMaintEntry 3 }
dsucsuCfgMaintFlowCtrl OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flow Control for the Maint. port."
::= { dsucsuCfgMaintEntry 4 }
dsucsuCfgMaintStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopbits-1 (1),
stopbits-1-5 (2),
stopbits-2 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of Stopbits for the Maint. port."
::= { dsucsuCfgMaintEntry 5 }
dsucsuCfgMaintParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Parity for the Maint. port."
::= { dsucsuCfgMaintEntry 6 }
dsucsuCfgMaintDataBits OBJECT-TYPE
SYNTAX INTEGER
{
databits-7 (1),
databits-8 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Databits for the Maint. port."
::= { dsucsuCfgMaintEntry 7 }
dsucsuCfgMaintBaud OBJECT-TYPE
SYNTAX INTEGER
{
baud-1200 (1),
baud-2400 (2),
baud-4800 (3),
baud-9600 (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Baud rate for the Maint. port."
::= { dsucsuCfgMaintEntry 8 }
dsucsuCfgCommTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgCommEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Communication Port Configuration"
::= { dsucsu 12 }
dsucsuCfgCommEntry OBJECT-TYPE
SYNTAX DsucsuCfgCommEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Communication Port Configuration Object"
INDEX { dsucsuCfgCommSlot, dsucsuCfgCommNode }
::= { dsucsuCfgCommTable 1 }
DsucsuCfgCommEntry ::=
SEQUENCE
{
dsucsuCfgCommSlot
INTEGER (1..16),
dsucsuCfgCommNode
INTEGER (1..255),
dsucsuCfgCommChanType
INTEGER,
dsucsuCfgCommFlowCtrl
INTEGER,
dsucsuCfgCommStopBits
INTEGER,
dsucsuCfgCommParity
INTEGER,
dsucsuCfgCommDataBits
INTEGER,
dsucsuCfgCommBaud
INTEGER
}
dsucsuCfgCommSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgCommEntry 1 }
dsucsuCfgCommNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgCommEntry 2 }
dsucsuCfgCommChanType OBJECT-TYPE
SYNTAX INTEGER
{
disabled (1),
nsms (2),
ascii (3),
alarm (4),
ext-event (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of data passed over the Communication port."
::= { dsucsuCfgCommEntry 3 }
dsucsuCfgCommFlowCtrl OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flow Control for the Communication port."
::= { dsucsuCfgCommEntry 4 }
dsucsuCfgCommStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopbits-1 (1),
stopbits-1-5 (2),
stopbits-2 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of Stopbits for the Communication port."
::= { dsucsuCfgCommEntry 5 }
dsucsuCfgCommParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Parity for the Communication port."
::= { dsucsuCfgCommEntry 6 }
dsucsuCfgCommDataBits OBJECT-TYPE
SYNTAX INTEGER
{
databits-7 (1),
databits-8 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Databits for the Communication port."
::= { dsucsuCfgCommEntry 7 }
dsucsuCfgCommBaud OBJECT-TYPE
SYNTAX INTEGER
{
baud-1200 (1),
baud-2400 (2),
baud-4800 (3),
baud-9600 (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Baud rate for the Communication port."
::= { dsucsuCfgCommEntry 8 }
dsucsuCfgBrdTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgBrdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Network timing for 3000N board."
::= { dsucsu 13 }
dsucsuCfgBrdEntry OBJECT-TYPE
SYNTAX DsucsuCfgBrdEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Board Timing Configuration Object."
INDEX { dsucsuCfgBrdSlot, dsucsuCfgBrdNode }
::= { dsucsuCfgBrdTable 1 }
DsucsuCfgBrdEntry ::=
SEQUENCE
{
dsucsuCfgBrdSlot
INTEGER (1..16),
dsucsuCfgBrdNode
INTEGER (1..255),
dsucsuCfgBrdTiming
INTEGER
}
dsucsuCfgBrdSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgBrdEntry 1 }
dsucsuCfgBrdNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgBrdEntry 2 }
dsucsuCfgBrdTiming OBJECT-TYPE
SYNTAX INTEGER
{
master (1),
port1 (2),
port2 (3),
port3 (4),
port4 (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Board Level Timing for a 3000N."
::= { dsucsuCfgBrdEntry 3 }
dsucsuCfgDacsTable OBJECT IDENTIFIER ::= { dsucsu 14 }
dsucsuCfgAutoAssignTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgAutoAssignEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Automatically assign the proper amount of bandwidth."
::= { dsucsuCfgDacsTable 1 }
dsucsuCfgAutoAssignEntry OBJECT-TYPE
SYNTAX DsucsuCfgAutoAssignEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"DACS auto assign Configuration Object."
INDEX { dsucsuConnAutoSlot, dsucsuConnAutoNode, dsucsuConnAutoSrcPort }
::= { dsucsuCfgAutoAssignTable 1 }
DsucsuCfgAutoAssignEntry ::=
SEQUENCE
{
dsucsuConnAutoSlot
INTEGER (1..16),
dsucsuConnAutoNode
INTEGER (1..255),
dsucsuConnAutoSrcPort
INTEGER (1..4),
dsucsuConnAutoStartDS0
INTEGER,
dsucsuConnAutoDestPort
INTEGER,
dsucsuConnAutoType
INTEGER,
dsucsuConnDteRate
INTEGER (0..1536000),
dsucsuConnDteDensity
INTEGER,
dsucsuConnDs0Required
INTEGER (0..24),
dsucsuConnAutoStatus
INTEGER,
dsucsuConnAutoUpdateCmd
INTEGER
}
dsucsuConnAutoSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgAutoAssignEntry 1 }
dsucsuConnAutoNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgAutoAssignEntry 2 }
dsucsuConnAutoSrcPort OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index to the 3000N source port of interest. 3000N supports
two DTE-V35/RS-499 DATA ports (P3-P4)."
::= { dsucsuCfgAutoAssignEntry 3 }
dsucsuConnAutoStartDS0 OBJECT-TYPE
SYNTAX INTEGER
{
ds0-01 (1),
ds0-02 (2),
ds0-03 (3),
ds0-04 (4),
ds0-05 (5),
ds0-06 (6),
ds0-07 (7),
ds0-08 (8),
ds0-09 (9),
ds0-10 (10),
ds0-11 (11),
ds0-12 (12),
ds0-13 (13),
ds0-14 (14),
ds0-15 (15),
ds0-16 (16),
ds0-17 (17),
ds0-18 (18),
ds0-19 (19),
ds0-20 (20),
ds0-21 (21),
ds0-22 (22),
ds0-23 (23),
ds0-24 (24),
no-current-connections (40),
non-continuous-ds0s (41)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Port1/2 includes 24 DS0's. This value is the starting DS0
used by the node to allocate DS0s to meet port(3-4)-dte
requirements. Sequential, contiguous DS0s are assigned.
The number of DS0s required is based upon the DTE Data Rate
and DTE Channel Mapping. The node's response to an entry
may be gathered by querying dsucsuConnAutoStatus. To assign
DS0s in a non-contiguous format, use the CfgEditConnTable."
::= { dsucsuCfgAutoAssignEntry 4 }
dsucsuConnAutoDestPort OBJECT-TYPE
SYNTAX INTEGER
{
port1 (1),
port2 (2),
port3 (3),
port4 (4),
not-connected (33)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selects the port for which DS0s are automatically
allocated to one of the T1 network ports. Node software may
not allow connection of port1 to port1."
::= { dsucsuCfgAutoAssignEntry 5 }
dsucsuConnAutoType OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
voice (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the type of traffic being transported. The 3000N
supports data (1) or voice (2). The selected type will be
assigned to all DS0s."
::= { dsucsuCfgAutoAssignEntry 6 }
dsucsuConnDteRate OBJECT-TYPE
SYNTAX INTEGER (0..1536000)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Data rate of the DTE port. Can be chaged from
the CfgDteTable."
::= { dsucsuCfgAutoAssignEntry 7 }
dsucsuConnDteDensity OBJECT-TYPE
SYNTAX INTEGER
{
bit-7-stuff (56),
clear-channel (64)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Channel/DS0 format for the DTE port. Can be
changed from the CfgDteTable."
::= { dsucsuCfgAutoAssignEntry 8 }
dsucsuConnDs0Required OBJECT-TYPE
SYNTAX INTEGER (0..24)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of DS0s required by the node's DTE port.
This is based upon the DTE data rate and channel density
selections."
::= { dsucsuCfgAutoAssignEntry 9 }
dsucsuConnAutoStatus OBJECT-TYPE
SYNTAX INTEGER
{
connections-valid (1),
connections-not-valid (2),
incorrect-bandwidth (3),
bandwidth-conflict (4),
no-current-connections(5),
port-type-valid(6),
port-type-invalid(7),
start-ds0-valid(8),
start-ds0-invalid(9),
port-valid(10),
port-invalid(11)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Queries the node's connection status. Code
will be returned when a connection set or update is rejected or accepted."
::= { dsucsuCfgAutoAssignEntry 10 }
dsucsuConnAutoUpdateCmd OBJECT-TYPE
SYNTAX INTEGER
{
update (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Updates the connections with the edit buffer. The edit buffer
is comprised of any changes sent (set) from the dsucsuCfgAutoAssignEntry."
::= { dsucsuCfgAutoAssignEntry 11 }
dsucsuCfgCurrentConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgCurrentConnections
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Retrieves node's active connections assignments for
display only. To edit connections, use CfgConnAutoAssign
or CfgEditConnTable."
::= { dsucsuCfgDacsTable 2 }
dsucsuCfgCurrentConnections OBJECT-TYPE
SYNTAX DsucsuCfgCurrentConnections
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Current Connections Table."
INDEX { dsucsuSlot, dsucsuNode, dsucsuT1Index, dsucsuDs0 }
::= { dsucsuCfgCurrentConnTable 1 }
DsucsuCfgCurrentConnections ::=
SEQUENCE
{
dsucsuSlot INTEGER (1..16),
dsucsuNode INTEGER (1..255),
dsucsuT1Index INTEGER (1..4),
dsucsuDs0 INTEGER (1..24),
dsucsuDtePort INTEGER,
dsucsuType INTEGER
}
dsucsuSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgCurrentConnections 1 }
dsucsuNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgCurrentConnections 2 }
dsucsuT1Index OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index to T1 network port of interest. The 3000N supports
two NETWORK/DSX-1 ports."
::= { dsucsuCfgCurrentConnections 3 }
dsucsuDs0 OBJECT-TYPE
SYNTAX INTEGER (1..24)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS0 number 1 through 24 corresponding to the T1 network
port index."
::= { dsucsuCfgCurrentConnections 4 }
dsucsuDtePort OBJECT-TYPE
SYNTAX INTEGER
{
port1 (1),
port2 (2),
port3 (3),
port4 (4),
not-connected (33)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DS0 assignment for indexed T1 network port. After
making any adjustments to the connections, the
dsucsuCfgConnUpdateCmd must be sent. Node software
may not permit port 1 connections to itself."
::= { dsucsuCfgCurrentConnections 5 }
dsucsuType OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
voice (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Defines the type of traffic being transported. The 3000N
supports data (1) or voice (2)."
::= { dsucsuCfgCurrentConnections 6 }
dsucsuCfgEditConnTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCfgEditConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Manually assign the proper amount of bandwidth."
::= { dsucsuCfgDacsTable 3 }
dsucsuCfgEditConnEntry OBJECT-TYPE
SYNTAX DsucsuCfgEditConnEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Edits current DS0 assignment. After making any adjustments
to the connections, the dsucsuCfgConnUpdateCmd must be sent."
INDEX { dsucsuConnSlot, dsucsuConnNode, dsucsuConnSrcPort, dsucsuConnSrcDs0 }
::= { dsucsuCfgEditConnTable 1 }
DsucsuCfgEditConnEntry ::=
SEQUENCE
{
dsucsuConnSlot INTEGER (1..16),
dsucsuConnNode INTEGER (1..255),
dsucsuConnSrcPort INTEGER (1..4),
dsucsuConnSrcDs0 INTEGER (1..24),
dsucsuConnDestPort INTEGER,
dsucsuConnDestDs0 INTEGER,
dsucsuConnType INTEGER,
dsucsuConnNumDs0s INTEGER (1..24),
dsucsuConnSetStatus INTEGER,
dsucsuConnConnect INTEGER,
dsucsuConnUpdateRequired INTEGER,
dsucsuConnUpdateCmd INTEGER,
dsucsuConnClearEditBuff INTEGER
}
dsucsuConnSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCfgEditConnEntry 1 }
dsucsuConnNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCfgEditConnEntry 2 }
dsucsuConnSrcPort OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Index to the source port of interest. The 3000N
supports two NETWORK/DSX-1 and two DTE ports."
::= { dsucsuCfgEditConnEntry 3 }
dsucsuConnSrcDs0 OBJECT-TYPE
SYNTAX INTEGER (1..24)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The source DS0 number 1 through 24 corresponding to the T1 network
port index"
::= { dsucsuCfgEditConnEntry 4 }
dsucsuConnDestPort OBJECT-TYPE
SYNTAX INTEGER
{
port1 (1),
port2 (2),
port3 (3),
port4 (4),
not-connected (33)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Index to the destination port of interest. The 3000N
supports two NETWORK/DSX-1 and two DTE ports."
::= { dsucsuCfgEditConnEntry 5 }
dsucsuConnDestDs0 OBJECT-TYPE
SYNTAX INTEGER
{
ds0-01 (1),
ds0-02 (2),
ds0-03 (3),
ds0-04 (4),
ds0-05 (5),
ds0-06 (6),
ds0-07 (7),
ds0-08 (8),
ds0-09 (9),
ds0-10 (10),
ds0-11 (11),
ds0-12 (12),
ds0-13 (13),
ds0-14 (14),
ds0-15 (15),
ds0-16 (16),
ds0-17 (17),
ds0-18 (18),
ds0-19 (19),
ds0-20 (20),
ds0-21 (21),
ds0-22 (22),
ds0-23 (23),
ds0-24 (24),
no-current-connections (40),
non-continuous-ds0s (41)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DS0 assignment for indexed T1 network port. After making
any adjustments to the connections, the dsucsuConnUpdateCmd
must be sent. Node software may not permit connections between
the same port and itself."
::= { dsucsuCfgEditConnEntry 6 }
dsucsuConnType OBJECT-TYPE
SYNTAX INTEGER
{
data (1),
voice (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the type of traffic being transported. The 3000N
supports data (1) or voice (2)."
::= { dsucsuCfgEditConnEntry 7 }
dsucsuConnNumDs0s OBJECT-TYPE
SYNTAX INTEGER (1..24)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The total number of Ds0s to be connected. The number of Ds0s
must be between 1 and 24."
::= { dsucsuCfgEditConnEntry 8 }
dsucsuConnSetStatus OBJECT-TYPE
SYNTAX INTEGER
{
connections-valid (1),
connections-not-valid (2),
incorrect-bandwidth (3),
bandwidth-conflict (4),
no-current-connections(5),
port-type-valid(6),
port-type-invalid(7),
destination-ds0-valid(8),
destination-ds0-invalid(9),
port-valid(10),
port-invalid(11),
num-ds0s-valid(12),
num-ds0s-invalid(13)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays node status from the last SNMP issed set command."
::= { dsucsuCfgEditConnEntry 9 }
dsucsuConnConnect OBJECT-TYPE
SYNTAX INTEGER
{
connect (1),
disconnect (2)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Updates the connections with the edit buffer. The edit buffer
is comprised of any changes sent (set) from the CfgEditConnTable."
::= { dsucsuCfgEditConnEntry 10}
dsucsuConnUpdateRequired OBJECT-TYPE
SYNTAX INTEGER
{
update-not-required (1),
update-required (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays node status from the last connection update."
::= { dsucsuCfgEditConnEntry 11 }
dsucsuConnUpdateCmd OBJECT-TYPE
SYNTAX INTEGER
{
update (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Sends the updated connections from the edit buffer to the node.
The edit buffer is comprised of any changes sent (set) from the CfgEditConnTable."
::= { dsucsuCfgEditConnEntry 12}
dsucsuConnClearEditBuff OBJECT-TYPE
SYNTAX INTEGER
{
clear-edit (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Removes all changes from edit buffer. The edit buffer is
comprised of any changes sent (set) from the CfgEditConnTable."
::= { dsucsuCfgEditConnEntry 13 }
dsucsuDiagNetTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuDiagNetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Network Diagnostic attributes. Loopbacks,
tests and their respective results can be initiated,
cancelled and examined."
::= { dsucsu 15 }
dsucsuDiagNetEntry OBJECT-TYPE
SYNTAX DsucsuDiagNetEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A Network Diagnostic entry"
INDEX { dsucsuDiagNetSlot, dsucsuDiagNetNode, dsucsuDiagNetIndex }
::= { dsucsuDiagNetTable 1 }
DsucsuDiagNetEntry ::=
SEQUENCE
{
dsucsuDiagNetSlot
INTEGER (1..16),
dsucsuDiagNetNode
INTEGER (1..255),
dsucsuDiagNetIndex
INTEGER (1..2),
dsucsuDiagNetLclNetAggLpbk
INTEGER,
dsucsuDiagNetLclNetLpbk
INTEGER,
dsucsuDiagNetLclNetPayload
INTEGER,
dsucsuDiagNetLclNetBiDir
INTEGER,
dsucsuDiagNetRemCsuLpbk
INTEGER,
dsucsuDiagNetRemDsuLpbk
INTEGER,
dsucsuDiagNetEvElapTime
TimeTicks,
dsucsuDiagNetEvCRC6Err
Counter,
dsucsuDiagNetEvOofErr
Counter,
dsucsuDiagNetErrEvents
Counter,
dsucsuDiagNetClearEvReg
INTEGER
}
dsucsuDiagNetSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuDiagNetEntry 1 }
dsucsuDiagNetNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuDiagNetEntry 2 }
dsucsuDiagNetIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The network number to be examined for a particular
node (3000N only)."
::= { dsucsuDiagNetEntry 3 }
dsucsuDiagNetLclNetAggLpbk OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables the operator to control and examine the
local aggregate loopback. This loopback occurs on
the net side of the local transmit and receive
logic. The unit continues to transmit data across
the network and also loops the data back to its own
receiver circuitry."
::= { dsucsuDiagNetEntry 4 }
dsucsuDiagNetLclNetLpbk OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables the operator to control and examine the
local network loopback. This loopback allows the
operator to disconnect the side of the network by
transmitting the data recovered from the network."
::= { dsucsuDiagNetEntry 5 }
dsucsuDiagNetLclNetPayload OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables the operator to control and examine the
network payload loopback. This loopback occurs on
the net side of the local transmit and receive
logic. The unit continues to transmit data across
the network and also loops the data back to its own
receiver circuitry."
::= { dsucsuDiagNetEntry 6 }
dsucsuDiagNetLclNetBiDir OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables the operator to control and examine the
local network loopback. This loopback allows the
operator to disconnect the side of the network by
transmitting the data recovered from the network
in both directions."
::= { dsucsuDiagNetEntry 7 }
dsucsuDiagNetRemCsuLpbk OBJECT-TYPE
SYNTAX INTEGER
{
transmitLoopUpCode (1),
transmitLoopDownCode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables the operator to control and examine the
remote CSU loopback. This loopback allows the
operator to test the operation of the local
channel, the aggregate and the remote CSU."
::= { dsucsuDiagNetEntry 8 }
dsucsuDiagNetRemDsuLpbk OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables the operator to control and examine the
remote aggregate loopback. This loopback allows the
operator to test the entire system from the local
unit through the network to the remote node's
transmit and receive front end."
::= { dsucsuDiagNetEntry 9 }
dsucsuDiagNetEvElapTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time elapsed since the Event Test started.
The new Event Test commences as soon as the
previous Event Test registers are cleared."
::= { dsucsuDiagNetEntry 10 }
dsucsuDiagNetEvCRC6Err OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of CRC6 errors encountered during the
Event Test period."
::= { dsucsuDiagNetEntry 11 }
dsucsuDiagNetEvOofErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Out-Of-Frame errors encountered
during the Event Test period."
::= { dsucsuDiagNetEntry 12 }
dsucsuDiagNetErrEvents OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Errored Events encountered during
the Event Test period."
::= { dsucsuDiagNetEntry 13 }
dsucsuDiagNetClearEvReg OBJECT-TYPE
SYNTAX INTEGER
{
clearRegister (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Clear all the Event Test registers. Automatically
initiates a new Event Test."
::= { dsucsuDiagNetEntry 14 }
dsucsuDiagDteTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuDiagDteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of DTE channel diagnostics."
::= { dsucsu 16 }
dsucsuDiagDteEntry OBJECT-TYPE
SYNTAX DsucsuDiagDteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A DTE channel diagnostic entry"
INDEX { dsucsuDiagDteSlot, dsucsuDiagDteNode, dsucsuDiagDteIndex }
::= { dsucsuDiagDteTable 1 }
DsucsuDiagDteEntry ::=
SEQUENCE
{
dsucsuDiagDteSlot
INTEGER (1..16),
dsucsuDiagDteNode
INTEGER (1..255),
dsucsuDiagDteIndex
INTEGER (1..4),
dsucsuDiagDteLocalBiDir
INTEGER,
dsucsuDiagDteLocalPayload
INTEGER,
dsucsuDiagDteRemLpbk
INTEGER,
dsucsuDiagDteBertTestAct
INTEGER,
dsucsuDiagDteBertHourStrt
INTEGER (0..23),
dsucsuDiagDteBertMinStrt
INTEGER (0..59),
dsucsuDiagDteBertTimeElaps
TimeTicks,
dsucsuDiagDteBertErrors
Counter
}
dsucsuDiagDteSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuDiagDteEntry 1 }
dsucsuDiagDteNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuDiagDteEntry 2 }
dsucsuDiagDteIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The channel number to be examined for a particular
node."
::= { dsucsuDiagDteEntry 3 }
dsucsuDiagDteLocalBiDir OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Local Channel Loopback for the selected channel.
This is a local turnaround and is bi-directional."
::= { dsucsuDiagDteEntry 4 }
dsucsuDiagDteLocalPayload OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Local Payload Channel Loopback for the selected channel."
::= { dsucsuDiagDteEntry 5 }
dsucsuDiagDteRemLpbk OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Channel Remote Loopback for the selected channel.
This loopback transmits a code to the remote node
which will enable or disable a diagnostic loopback
at the addressed channel."
::= { dsucsuDiagDteEntry 6 }
dsucsuDiagDteBertTestAct OBJECT-TYPE
SYNTAX INTEGER
{
startBertTest (1),
stopBertTest (2),
injectErrorBertTest (3),
clearErrorBertTest (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT test related actions:
a: Starts a BERT test on a channel,
b: Stops a BERT test on a channel,
c: Inject Errors while the BERT test is running,
d: Clears BERT test errors."
::= { dsucsuDiagDteEntry 7 }
dsucsuDiagDteBertHourStrt OBJECT-TYPE
SYNTAX INTEGER (0..23)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the hour that the BERT test started."
::= { dsucsuDiagDteEntry 8 }
dsucsuDiagDteBertMinStrt OBJECT-TYPE
SYNTAX INTEGER (0..59)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays th minute that BERT test started."
::= { dsucsuDiagDteEntry 9 }
dsucsuDiagDteBertTimeElaps OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Elapsed time since the BERT Test started"
::= { dsucsuDiagDteEntry 10 }
dsucsuDiagDteBertErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of BERT test errors encountered during the
BERT Test."
::= { dsucsuDiagDteEntry 11 }
dsucsuDiagFrmTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuDiagFrmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of framed channel diagnostics."
::= { dsucsu 17 }
dsucsuDiagFrmEntry OBJECT-TYPE
SYNTAX DsucsuDiagFrmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A framed channel diagnostic entry"
INDEX { dsucsuDiagFrmSlot, dsucsuDiagFrmNode, dsucsuDiagFrmIndex }
::= { dsucsuDiagFrmTable 1 }
DsucsuDiagFrmEntry ::=
SEQUENCE
{
dsucsuDiagFrmSlot
INTEGER (1..16),
dsucsuDiagFrmNode
INTEGER (1..255),
dsucsuDiagFrmIndex
INTEGER (1..4),
dsucsuDiagFrmLclLpbk
INTEGER,
dsucsuDiagFrmLclPayload
INTEGER,
dsucsuDiagFrmLclBiDir
INTEGER,
dsucsuDiagFrmRemLpbk
INTEGER,
dsucsuDiagFrmLclDte
INTEGER,
dsucsuDiagFrmLclDte2
INTEGER,
dsucsuDiagFrmBertTestAct
INTEGER,
dsucsuDiagFrmEvElapTime
TimeTicks,
dsucsuDiagFrmEvBpvErr
Counter,
dsucsuDiagFrmEvOofErr
Counter,
dsucsuDiagFrmFrameErr
Counter,
dsucsuDiagFrmClearEvReg
INTEGER
}
dsucsuDiagFrmSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuDiagFrmEntry 1 }
dsucsuDiagFrmNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuDiagFrmEntry 2 }
dsucsuDiagFrmIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The channel number to be examined for a particular
node."
::= { dsucsuDiagFrmEntry 3 }
dsucsuDiagFrmLclLpbk OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Local Channel Loopback for the selected channel.
This is a local turnaround and is bi-directional."
::= { dsucsuDiagFrmEntry 4 }
dsucsuDiagFrmLclPayload OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Channel Remote Loopback for the selected channel.
This loopback transmits a code to the remote node
which will enable or disable a diagnostic loopback
at the addressed channel. This selection is
applicable only for DSX type channels."
::= { dsucsuDiagFrmEntry 5 }
dsucsuDiagFrmLclBiDir OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
DSX Loopback for the selected channel. This
selection is applicable only for DSX channels."
::= { dsucsuDiagFrmEntry 6 }
dsucsuDiagFrmRemLpbk OBJECT-TYPE
SYNTAX INTEGER
{
transmitLoopUpCode (1),
transmitLoopDownCode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Local Channel Loopback for the selected channel.
This loopback transmits a code to the remote node
which will enable or disable a diagnostic loopback
at the addressed channel. This selection is
applicable only for DSX channels."
::= { dsucsuDiagFrmEntry 7 }
dsucsuDiagFrmLclDte OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Local Channel Loopback for the selected channel.
This is a local turnaround and is bi-directional.
This selection is applicable only for CSU type channels."
::= { dsucsuDiagFrmEntry 8 }
dsucsuDiagFrmLclDte2 OBJECT-TYPE
SYNTAX INTEGER
{
enableLoopbackMode (1),
disableLoopbackMode (2),
notApplicable (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Channel Remote Loopback for the selected channel.
This loopback transmits a code to the remote node
which will enable or disable a diagnostic loopback
at the addressed channel. This selection is
applicable only for CSU type channels."
::= { dsucsuDiagFrmEntry 9 }
dsucsuDiagFrmBertTestAct OBJECT-TYPE
SYNTAX INTEGER
{
startBertTest (1),
stopBertTest (2),
injectErrorBertTest (3),
clearErrorBertTest (4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"BERT test related actions:
a: Starts a BERT test on a channel,
b: Stops a BERT test on a channel,
c: Inject Errors while the BERT test is running,
d: Clears BERT test errors."
::= { dsucsuDiagFrmEntry 10 }
dsucsuDiagFrmEvElapTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time elapsed since the PBX Event Test started.
This selection is applicable only for PBX channels."
::= { dsucsuDiagFrmEntry 11 }
dsucsuDiagFrmEvBpvErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Bipolar Violations encountered
during the Event Test. This selection is applicable
only for PBX channels."
::= { dsucsuDiagFrmEntry 12 }
dsucsuDiagFrmEvOofErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Out-Of-Frame Errors encountered
during the Event Test. This selection is applicable
only for PBX channels."
::= { dsucsuDiagFrmEntry 13 }
dsucsuDiagFrmFrameErr OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Frame Errors encountered during the
Event Test. This selection is applicable only for
PBX channels."
::= { dsucsuDiagFrmEntry 14 }
dsucsuDiagFrmClearEvReg OBJECT-TYPE
SYNTAX INTEGER
{
clearRegister (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Clears all the PBX Event Test registers. This
selection is applicable only for PBX channels."
::= { dsucsuDiagFrmEntry 15 }
dsucsuDiagAuxTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuDiagAuxEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Auxillary Channel Diagnostics"
::= { dsucsu 18 }
dsucsuDiagAuxEntry OBJECT-TYPE
SYNTAX DsucsuDiagAuxEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Auxilary diagnostic entry"
INDEX { dsucsuDiagAuxSlot, dsucsuDiagAuxNode }
::= { dsucsuDiagAuxTable 1 }
DsucsuDiagAuxEntry ::=
SEQUENCE
{
dsucsuDiagAuxSlot
INTEGER (1..16),
dsucsuDiagAuxNode
INTEGER (1..255),
dsucsuDiagAuxChAStatus
INTEGER,
dsucsuDiagAuxChBStatus
INTEGER,
dsucsuDiagAuxFdlStatus
INTEGER,
dsucsuDiagAuxFdl2Status
INTEGER,
dsucsuDiagAuxMaintStatus
INTEGER,
dsucsuDiagAuxCommStatus
INTEGER
}
dsucsuDiagAuxSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuDiagAuxEntry 1 }
dsucsuDiagAuxNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuDiagAuxEntry 2 }
dsucsuDiagAuxChAStatus OBJECT-TYPE
SYNTAX INTEGER
{
down (1),
sync (2),
off (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of Supervisory link channel A."
::= { dsucsuDiagAuxEntry 3 }
dsucsuDiagAuxChBStatus OBJECT-TYPE
SYNTAX INTEGER
{
down (1),
sync (2),
off (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of Supervisory Link Channel B."
::= { dsucsuDiagAuxEntry 4 }
dsucsuDiagAuxFdlStatus OBJECT-TYPE
SYNTAX INTEGER
{
down (1),
sync (2),
off (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of Facility Data Link (PORT1)."
::= { dsucsuDiagAuxEntry 5 }
dsucsuDiagAuxFdl2Status OBJECT-TYPE
SYNTAX INTEGER
{
down (1),
sync (2),
off (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Status of Facility Data Link (PORT2)."
::= { dsucsuDiagAuxEntry 6 }
dsucsuDiagAuxMaintStatus OBJECT-TYPE
SYNTAX INTEGER
{
down (1),
sync (2),
off (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
" The Maint. Port Supervisory link status."
::= { dsucsuDiagAuxEntry 7 }
dsucsuDiagAuxCommStatus OBJECT-TYPE
SYNTAX INTEGER
{
down (1),
sync (2),
off (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Communications port Supervisory link status."
::= { dsucsuDiagAuxEntry 8 }
dsucsuDiagPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuDiagPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Port Specific Display only Diagnostics"
::= { dsucsu 19 }
dsucsuDiagPortEntry OBJECT-TYPE
SYNTAX DsucsuDiagPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Port Specific Display only entry"
INDEX { dsucsuDiagPortSlot, dsucsuDiagPortNode, dsucsuDiagPortIndex }
::= { dsucsuDiagPortTable 1 }
DsucsuDiagPortEntry ::=
SEQUENCE
{
dsucsuDiagPortSlot
INTEGER (1..16),
dsucsuDiagPortNode
INTEGER (1..255),
dsucsuDiagPortIndex
INTEGER (1..4),
dsucsuDiagPortType
INTEGER,
dsucsuDiagPortStatus
INTEGER
}
dsucsuDiagPortSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuDiagPortEntry 1 }
dsucsuDiagPortNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuDiagPortEntry 2 }
dsucsuDiagPortIndex OBJECT-TYPE
SYNTAX INTEGER (1..4)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index: unique per port."
::= { dsucsuDiagPortEntry 3 }
dsucsuDiagPortType OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
network (2),
dsx (3),
pbx (4),
rs449 (5),
rs232 (6),
mil188 (7),
v35 (8),
dte (9),
tdm (10)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port type (NET/DSX/PBX/V.35/RS-449)."
::= { dsucsuDiagPortEntry 4 }
dsucsuDiagPortStatus OBJECT-TYPE
SYNTAX INTEGER
{
clearOK (1),
redAlarm (2),
yellowAlarm (3),
syncLoss (4),
bpvAlarm (5),
blueAlarm (6),
test (7),
timeout (8),
notApplicable (9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current status condition of a particular port."
::= { dsucsuDiagPortEntry 5 }
dsucsuIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table contains various ESF stats collected over
the last 96 15-minute intervals (24 hours total
time)."
::= { dsucsu 20 }
dsucsuIntervalEntry OBJECT-TYPE
SYNTAX DsucsuIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry in the table of ESF interval stats."
INDEX { dsucsuIntervalSlot, dsucsuIntervalNode,
dsucsuIntervalPort, dsucsuIntervalNum }
::= { dsucsuIntervalTable 1 }
DsucsuIntervalEntry ::=
SEQUENCE
{
dsucsuIntervalSlot
INTEGER (1..16),
dsucsuIntervalNode
INTEGER (1..255),
dsucsuIntervalPort
INTEGER (1..2),
dsucsuIntervalNum
INTEGER (1..96),
dsucsuIntervalESs
Counter,
dsucsuIntervalSESs
Counter,
dsucsuIntervalBPVs
Counter,
dsucsuIntervalFSs
Counter
}
dsucsuIntervalSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuIntervalEntry 1 }
dsucsuIntervalNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuIntervalEntry 2 }
dsucsuIntervalPort OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index: unique per port."
::= { dsucsuIntervalEntry 3 }
dsucsuIntervalNum OBJECT-TYPE
SYNTAX INTEGER (1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sequence number for the selected interval."
::= { dsucsuIntervalEntry 4 }
dsucsuIntervalESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Errored Seconds (as defined in Bell
Publication 62411) encountered in the user
registers during the selected interval."
::= { dsucsuIntervalEntry 5 }
dsucsuIntervalSESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Severely Errored Seconds (as
defined in Bell Publication 62411) encountered in
the user registers during the selected interval."
::= { dsucsuIntervalEntry 6 }
dsucsuIntervalBPVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Bipolar Violations (as defined in
Bell Publication 62411) encountered in the user
registers during the selected interval."
::= { dsucsuIntervalEntry 7 }
dsucsuIntervalFSs OBJECT-TYPE
SYNTAX Counter
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Failed Seconds (as defined in Bell
Publication 62411) encountered in the user
registers during the selected interval."
::= { dsucsuIntervalEntry 8 }
dsucsuCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table contains various ESF stats collected
over the current 15-minute interval."
::= { dsucsu 22 }
dsucsuCurrentEntry OBJECT-TYPE
SYNTAX DsucsuCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry in the table of the current ESF stats."
INDEX { dsucsuCurrentSlot, dsucsuCurrentNode,
dsucsuCurrentPort }
::= { dsucsuCurrentTable 1 }
DsucsuCurrentEntry ::=
SEQUENCE
{
dsucsuCurrentSlot
INTEGER (1..16),
dsucsuCurrentNode
INTEGER (1..255),
dsucsuCurrentPort
INTEGER (1..2),
dsucsuCurrentESs
Counter,
dsucsuCurrentSESs
Counter,
dsucsuCurrentBPVs
Counter,
dsucsuCurrentSECs
Counter,
dsucsuCurrentStatus
INTEGER
}
dsucsuCurrentSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuCurrentEntry 1 }
dsucsuCurrentNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuCurrentEntry 2 }
dsucsuCurrentPort OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index: unique per port."
::= { dsucsuCurrentEntry 3 }
dsucsuCurrentESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Errored Seconds (as defined in Bell
Publication 62411) encountered in the user
registers during the current 15 minute interval."
::= { dsucsuCurrentEntry 4 }
dsucsuCurrentSESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Severely Errored Seconds (as defined
in Bell Publication 62411) encountered in the user
registers during the current 15 minute interval."
::= { dsucsuCurrentEntry 5 }
dsucsuCurrentBPVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Bipolar Violations (as defined in
Bell Publication 62411) encountered in the user
registers during the current 15 minute interval."
::= { dsucsuCurrentEntry 6 }
dsucsuCurrentSECs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds elapsed in the current 15 minute
interval."
::= { dsucsuCurrentEntry 7 }
dsucsuCurrentStatus OBJECT-TYPE
SYNTAX INTEGER
{
frozen (1),
unfrozen (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indication of whether statistics have been halted
during current 15 minute interval."
::= { dsucsuCurrentEntry 8 }
dsucsuTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF DsucsuTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The table contains the cummulative sum of various
ESF stats collected over the last 24 hour period."
::= { dsucsu 24 }
dsucsuTotalEntry OBJECT-TYPE
SYNTAX DsucsuTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Entry in the table of the total ESF stats."
INDEX { dsucsuTotalSlot, dsucsuTotalNode,
dsucsuTotalPort }
::= { dsucsuTotalTable 1 }
DsucsuTotalEntry ::=
SEQUENCE
{
dsucsuTotalSlot
INTEGER (1..16),
dsucsuTotalNode
INTEGER (1..255),
dsucsuTotalPort
INTEGER (1..2),
dsucsuTotalESs
Counter,
dsucsuTotalSESs
Counter,
dsucsuTotalBPVs
Counter,
dsucsuTotalSECs
Counter,
dsucsuTotalStatus
INTEGER
}
dsucsuTotalSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsuTotalEntry 1 }
dsucsuTotalNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsuTotalEntry 2 }
dsucsuTotalPort OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The port index: unique per port."
::= { dsucsuTotalEntry 3 }
dsucsuTotalESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Errored Seconds (as defined in Bell
Publication 62411) encountered in the user
registers in the last 24 hour period (96
intervals)."
::= { dsucsuTotalEntry 4 }
dsucsuTotalSESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Severely Errored Seconds (as defined
in Bell Publication 62411) encountered in the user
registers in the last 24 hour period (96
intervals)."
::= { dsucsuTotalEntry 5 }
dsucsuTotalBPVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Bipolar Violations (as defined in
Bell Publication 62411) encountered in the user
registers in the last 24 hour period (96
intervals)."
::= { dsucsuTotalEntry 6 }
dsucsuTotalSECs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds elapsed in the last 24 hours.
This will be the maximum value of 86400 unless the
addressed node was brought on-line with the this
period."
::= { dsucsuTotalEntry 7 }
dsucsuTotalStatus OBJECT-TYPE
SYNTAX INTEGER
{
frozen (1),
unfrozen (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indication of whether statistics have been halted
in the last 24 hours."
::= { dsucsuTotalEntry 8 }
dsucsuAlarmType OBJECT-TYPE
SYNTAX INTEGER
{
yellow-Alarm (1),
sync-Alarm (2),
red-Alarm (3),
bpv-Alarm (4),
confg-Activated (5),
confg-Stored (6),
pbx1-Yellow-Alarm (7),
pbx1-Red-Alarm (8),
pbx1-Los-Alarm (9),
pbx3-Yellow-Alarm (10),
pbx3-Red-Alarm (11),
pbx3-Los-Alarm (12),
ais-Alarm (13),
node-communications-lost (14),
sync-ais-Alarm (15),
ts16-ais-Alarm (16),
ts16-Los-Alarm (17),
remote-Alarm (18),
remote-ts16-Alarm (19),
frame-Error-Alarm (20),
crc4-Error-Alarm (21),
port2-Yellow-Alarm (22),
port2-Sync-Alarm (23),
port2-Red-Alarm (24),
port2-Bpv-Alarm (25),
power-Supply-Alarm (26),
fan-one-Failure (27),
fan-two-Failure (28),
yellow-Alarm-Clear (29),
sync-Alarm-Clear (30),
red-Alarm-Clear (31),
bpv-Alarm-Clear (32),
pbx1-Yellow-Alarm-Clear (33),
pbx1-Red-Alarm-Clear (34),
pbx1-Los-Alarm-Clear (35),
pbx3-Yellow-Alarm-Clear (36),
pbx3-Red-Alarm-Clear (37),
pbx3-Los-Alarm-Clear (38),
ais-Alarm-Clear (39),
node-communications-restored (40),
sync-ais-Alarm-Clear (41),
ts16-ais-Alarm-Clear (42),
ts16-Los-Alarm-Clear (43),
remote-Alarm-Clear (44),
remote-ts16-Alarm-Clear (45),
frame-Error-Alarm-Clear (46),
crc4-Error-Alarm-Clear (47),
port2-Yellow-Alarm-Clear (48),
port2-Sync-Alarm-Clear (49),
port2-Red-Alarm-Clear (50),
port2-Bpv-Alarm-Clear (51),
power-Supply-Alarm-Clear (52),
fan-one-Failure-Clear (53),
fan-two-Failure-Clear (54)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of alarms that are generated on the node"
::= { dsucsu 25 }
dsucsuAlarmSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the TyView node is attached."
::= { dsucsu 26 }
dsucsuAlarmNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { dsucsu 27 }
dsucsuAlarmName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the node which triggered the alarm."
::= { dsucsu 28 }
tyviewSysTable OBJECT IDENTIFIER ::= { tyview 1 }
tyviewSysRevSw OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The TyView software revision."
::= { tyviewSysTable 1 }
tyviewSysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name given to TyView system."
::= { tyviewSysTable 2 }
tyviewSysId OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The TyView system ID."
::= { tyviewSysTable 3 }
tyviewSysTimeOutFactor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TyView timeout factor."
::= { tyviewSysTable 4 }
tyviewSysObjectId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Tyview Domain Object Identifier."
::= { tyviewSysTable 5 }
tyviewSysSlotNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Physical Slot Number the NETEXEC is installed in."
::= { tyviewSysTable 6 }
tyviewSysClearDatabase OBJECT-TYPE
SYNTAX INTEGER
{
clearDatabase (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Clear the node database."
::= { tyviewSysTable 7 }
tyviewSysGetCommName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The GET community name."
::= { tyviewSysTable 8 }
tyviewSysSetCommName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The SET community name."
::= { tyviewSysTable 9 }
tyviewSysTrapCommName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The TRAP community name."
::= { tyviewSysTable 10 }
tyviewSysN1TrapDest OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The first Trap IP Destination."
::= { tyviewSysTable 11 }
tyviewSysN2TrapDest OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The second Trap IP Destination."
::= { tyviewSysTable 12 }
tyviewSysDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The NETEXEC date (mm/dd/yy)."
::= { tyviewSysTable 13 }
tyviewSysTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..5))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The NETEXEC time (hh:mm)."
::= { tyviewSysTable 14 }
tyviewSysMjrMnrLED OBJECT-TYPE
SYNTAX INTEGER
{
led-Off (1),
led-Red (2),
led-Green (3),
led-Yellow (4),
led-RedYellow (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Major/Minor LED status."
::= { tyviewSysTable 15 }
tyviewSysFanPSLED OBJECT-TYPE
SYNTAX INTEGER
{
led-Off (1),
led-Red (2),
led-Green (3),
led-Yellow (4),
led-RedYellow (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Fan / Power Supply LED status."
::= { tyviewSysTable 16 }
tyviewSysCtlrLED OBJECT-TYPE
SYNTAX INTEGER
{
led-Off (1),
led-Red (2),
led-Green (3),
led-Yellow (4),
led-RedYellow (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Controller LED status."
::= { tyviewSysTable 17 }
tyviewSysSlipLED OBJECT-TYPE
SYNTAX INTEGER
{
led-Off (1),
led-Red (2),
led-Green (3),
led-Yellow (4),
led-RedYellow (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The SLIP LED status."
::= { tyviewSysTable 18 }
tyviewSysCtlChLED OBJECT-TYPE
SYNTAX INTEGER
{
led-Off (1),
led-Red (2),
led-Green (3),
led-Yellow (4),
led-RedYellow (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Control Channel LED status."
::= { tyviewSysTable 19 }
tyviewSysTDMLED OBJECT-TYPE
SYNTAX INTEGER
{
led-Off (1),
led-Red (2),
led-Green (3),
led-Yellow (4),
led-RedYellow (5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The TDM LED status."
::= { tyviewSysTable 20 }
tyviewSysMaintUseage OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
command (2),
slip (3),
tp-modem (4),
diagnostic (5),
ppp (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port useage specification."
::= { tyviewSysTable 21 }
tyviewSysMaintDataBits OBJECT-TYPE
SYNTAX INTEGER
{
databits-7 (1),
databits-8 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port databits specification."
::= { tyviewSysTable 22 }
tyviewSysMaintRate OBJECT-TYPE
SYNTAX INTEGER
{
rate-1200 (1),
rate-2400 (2),
rate-4800 (3),
rate-9600 (4),
rate-19200 (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port rate specification."
::= { tyviewSysTable 23 }
tyviewSysMaintStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopbits-1 (1),
stopbits-2 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port stopbits specification."
::= { tyviewSysTable 24 }
tyviewSysMaintParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port parity specification."
::= { tyviewSysTable 25 }
tyviewSysMaintMtu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port maximum trans unit size."
::= { tyviewSysTable 26 }
tyviewSysMaintCompression OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port compression specification."
::= { tyviewSysTable 27 }
tyviewSysMaintSubnetMask OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port subnet mask."
::= { tyviewSysTable 28 }
tyviewSysMaintLocalIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port local IP address."
::= { tyviewSysTable 29 }
tyviewSysMaintPeerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maintenance Port peer IP address."
::= { tyviewSysTable 30 }
tyviewSysComUseage OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
command (2),
slip (3),
tp-modem (4),
diagnostic (5),
ppp (6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port useage specification."
::= { tyviewSysTable 31 }
tyviewSysComDataBits OBJECT-TYPE
SYNTAX INTEGER
{
databits-7 (1),
databits-8 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port databits specification."
::= { tyviewSysTable 32 }
tyviewSysComRate OBJECT-TYPE
SYNTAX INTEGER
{
rate-1200 (1),
rate-2400 (2),
rate-4800 (3),
rate-9600 (4),
rate-19200 (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port rate specification."
::= { tyviewSysTable 33 }
tyviewSysComStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopbits-1 (1),
stopbits-2 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port stopbits specification."
::= { tyviewSysTable 34 }
tyviewSysComParity OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
odd (2),
even (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port parity specification."
::= { tyviewSysTable 35 }
tyviewSysComMtu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port maximum trans unit size."
::= { tyviewSysTable 36 }
tyviewSysComCompression OBJECT-TYPE
SYNTAX INTEGER
{
off (1),
on (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port compression specification."
::= { tyviewSysTable 37 }
tyviewSysComSubnetMask OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port subnet mask."
::= { tyviewSysTable 38 }
tyviewSysComLocalIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port local IP address."
::= { tyviewSysTable 39 }
tyviewSysComPeerIP OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Com Port peer IP address."
::= { tyviewSysTable 40 }
tyviewSysTelnetEna OBJECT-TYPE
SYNTAX INTEGER
{
disabled (1),
enabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Telnet log-in enable."
::= { tyviewSysTable 41 }
tyviewSysTelnetTO OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Telnet auto-logout timeout (minutes)."
::= { tyviewSysTable 42 }
tyviewSysClrMjrMin OBJECT-TYPE
SYNTAX INTEGER
{
clearMajorMinor (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Clear major/minor alarm window / LED."
::= { tyviewSysTable 43 }
tyviewDatabaseTable OBJECT-TYPE
SYNTAX SEQUENCE OF TyviewDatabaseEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of tyview database entries."
::= { tyview 2 }
tyviewDatabaseEntry OBJECT-TYPE
SYNTAX TyviewDatabaseEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System Object for TyView Database"
INDEX { tyviewDatabaseSlot, tyviewDatabaseNode }
::= { tyviewDatabaseTable 1 }
TyviewDatabaseEntry ::=
SEQUENCE
{
tyviewDatabaseSlot
INTEGER(1..16),
tyviewDatabaseNode
INTEGER(1..255),
tyviewDatabaseName
DisplayString (SIZE (0..8)),
tyviewDatabaseStatus
INTEGER
}
tyviewDatabaseSlot OBJECT-TYPE
SYNTAX INTEGER (1..16)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The PC port to which the node is attached."
::= { tyviewDatabaseEntry 1 }
tyviewDatabaseNode OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The node ID: unique per port ID."
::= { tyviewDatabaseEntry 2 }
tyviewDatabaseName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The unique name of the node."
::= { tyviewDatabaseEntry 3 }
tyviewDatabaseStatus OBJECT-TYPE
SYNTAX INTEGER
{
ok (1),
timeout (2),
error (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last comm status."
::= { tyviewDatabaseEntry 4 }
tyviewBroadcastTable OBJECT IDENTIFIER ::= { tyview 3 }
tyviewBroadcastSetTime OBJECT-TYPE
SYNTAX INTEGER
{
setTime (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Broadcast the time to all nodes."
::= { tyviewBroadcastTable 1 }
tyviewBroadcastForwardAlarms OBJECT-TYPE
SYNTAX INTEGER
{
forwardAlarms (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Broadcast alarm forwarding."
::= { tyviewBroadcastTable 2 }
tyviewBroadcastClearLoopbacks OBJECT-TYPE
SYNTAX INTEGER
{
clearNetLoopbacks (1),
clearChanLoopbacks (2)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Broadcast Clearing of loopbacks."
::= { tyviewBroadcastTable 3 }
tyviewTPTable OBJECT-TYPE
SYNTAX SEQUENCE OF TyviewTPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of Threshold Processing records."
::= { tyview 4 }
tyviewTPEntry OBJECT-TYPE
SYNTAX TyviewTPEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"System Object for Threshold Processing"
INDEX { tyviewTPRecord }
::= { tyviewTPTable 1 }
TyviewTPEntry ::=
SEQUENCE
{
tyviewTPRecord
INTEGER(1..25),
tyviewTPMonNodeMode
INTEGER,
tyviewTPNode
DisplayString (SIZE (0..8)),
tyviewTPAlarmType
INTEGER,
tyviewTPTriggerEvent
INTEGER,
tyviewTPInstance
INTEGER,
tyviewTPInterval
INTEGER,
tyviewTPEventAction
DisplayString (SIZE (0..32)),
tyviewTPDryContact
INTEGER,
tyviewTPClearDryContact
INTEGER
}
tyviewTPRecord OBJECT-TYPE
SYNTAX INTEGER (1..25)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Threshold Processing record referenced."
::= { tyviewTPEntry 1 }
tyviewTPMonNodeMode OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
all-nodes (2),
node-specific (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The mode used for monitoring nodes."
::= { tyviewTPEntry 2 }
tyviewTPNode OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..8))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The node name for node-specific monitoring."
::= { tyviewTPEntry 3 }
tyviewTPAlarmType OBJECT-TYPE
SYNTAX INTEGER
{
major (1),
minor (2),
all (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The alarm type used to trigger."
::= { tyviewTPEntry 4 }
tyviewTPTriggerEvent OBJECT-TYPE
SYNTAX INTEGER
{
alarm-on (1),
alarm-instance (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The event type used to trigger."
::= { tyviewTPEntry 5 }
tyviewTPInstance OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The alarm instance used to trigger."
::= { tyviewTPEntry 6 }
tyviewTPInterval OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The alarm interval used to trigger."
::= { tyviewTPEntry 7 }
tyviewTPEventAction OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The phone number dialed when triggered."
::= { tyviewTPEntry 8 }
tyviewTPDryContact OBJECT-TYPE
SYNTAX INTEGER
{
dry-contact-off (1),
dry-contact-major (2),
dry-contact-minor (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of Dry Contact when triggered."
::= { tyviewTPEntry 9 }
tyviewTPClearDryContact OBJECT-TYPE
SYNTAX INTEGER
{
clear-major (1),
clear-minor (2)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Clear major/minor Dry Contact."
::= { tyviewTPEntry 10 }
dsucsuTrap TRAP-TYPE
ENTERPRISE dsucsu
VARIABLES
{
dsucsuAlarmType,
dsucsuAlarmSlot,
dsucsuAlarmNode,
dsucsuAlarmName
}
DESCRIPTION
"A dsucsuTrap trap signifies that the
sending node had its `dsucsuAlarmType`
variable modified."
::= 0
END