TY1250I-MIB DEFINITIONS ::= BEGIN
IMPORTS
DisplayString
FROM SNMPv2-TC
Counter, TimeTicks, enterprises, IpAddress
FROM RFC1155-SMI
TRAP-TYPE
FROM RFC-1215
OBJECT-TYPE
FROM RFC-1212;
tylink OBJECT IDENTIFIER ::= { enterprises 466 }
dsucsu OBJECT IDENTIFIER ::= { tylink 1 }
tyview OBJECT IDENTIFIER ::= { tylink 2 }
ty1250 OBJECT IDENTIFIER ::= { tylink 3 }
ty1250SysTable OBJECT IDENTIFIER ::= { ty1250 1 }
ty1250SysType OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A textual description of the system model identifier.
for example: TYLINK1250"
::= { ty1250SysTable 1 }
ty1250SysSoftRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the Software Revision installed in this node."
::= { ty1250SysTable 2 }
ty1250SysHardRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..10))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the Hardware Revision of the node."
::= { ty1250SysTable 3 }
ty1250SysNumNetInstalled OBJECT-TYPE
SYNTAX INTEGER (0..1)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Network (DDS) ports that are
installed. There is 1 on the 1250."
::= { ty1250SysTable 4 }
ty1250SysNumDteInstalled OBJECT-TYPE
SYNTAX INTEGER (0..1)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of channels (DTE) that are
installed. There is 1 on the 1250."
::= { ty1250SysTable 5 }
ty1250SysNumMaintInstalled OBJECT-TYPE
SYNTAX INTEGER (0..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of Maintenance ports that are
installed. There are 2 on the 1250."
::= { ty1250SysTable 6 }
ty1250SysName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The user supplied name of the node. This object
does not affect operation, but may be useful
for network management."
::= { ty1250SysTable 7 }
ty1250CfgAppTable OBJECT IDENTIFIER ::= { ty1250 2 }
ty1250CfgAppClockSource OBJECT-TYPE
SYNTAX INTEGER
{
internal (1),
network (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Default timing, or clock, source. There must be only one
source on a DDS line. Node should always be network (2)
timed on a point-to-network application. Line
Driver applications need one node as internal (1),
one as network (2)."
::= { ty1250CfgAppTable 2 }
ty1250CfgAppCircuitId OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..30))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Circuit identifier provided by the service provider."
::= { ty1250CfgAppTable 3 }
ty1250CfgNetTable OBJECT IDENTIFIER ::= { ty1250 3 }
ty1250CfgNetType OBJECT-TYPE
SYNTAX INTEGER
{
dedicated (1),
switch56 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates type of service purchased on the attached
network line (DDS or SW56). Valid selections are
dedicated (1) and switch56 (2)."
::= { ty1250CfgNetTable 11 }
ty1250CfgNetGlareType OBJECT-TYPE
SYNTAX INTEGER
{
external-glare (1),
internal-glare (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, defines who wins when
there are simultanious incomming and outgoing
calls. If in doubt, select external-glare (2)."
::= { ty1250CfgNetTable 4 }
ty1250CfgNetEchoCan OBJECT-TYPE
SYNTAX INTEGER
{
ignore-echo-cancellers (1),
disable-echo-cancellers (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, some carriers, such
as Sprint, require you to disable-echo-cancellors (2)
for data apps on most lines. Calls take longer
to come up when disabling is done; use
ignore-echo-cancellers (1) on clear channel lines."
::= { ty1250CfgNetTable 5 }
ty1250CfgNetAnsMode OBJECT-TYPE
SYNTAX INTEGER
{
manual-answer (1),
automatic-answer (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, allows for manual-answer (1)
or automatic-answer (2) of inbound calls. Calls
may be answered in manual mode via vt100, DTR, or the
front panel button if so configured."
::= { ty1250CfgNetTable 6 }
ty1250CfgNetDialTimeout OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, time in seconds to wait
for far end to answer before giving up, and possibly
redialing."
::= { ty1250CfgNetTable 7 }
ty1250CfgNetNumRedial OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, number of times to
redial if the call fails."
::= { ty1250CfgNetTable 8 }
ty1250CfgNetRedialDelay OBJECT-TYPE
SYNTAX INTEGER (1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, delay in seconds
between redial attempts."
::= { ty1250CfgNetTable 9 }
ty1250CfgNetDefNum2Dial OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, default phone number
to dial. Numbers and dashes are allowed."
::= { ty1250CfgNetTable 10 }
ty1250CfgNetBPVThresholding OBJECT-TYPE
SYNTAX INTEGER
{
thresholding-at-10E-4 (1),
disable-thresholding (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allows the user to turn on and off the BPV thresholding
function. Valid values are thresholding_at_10E-4 (1) and
disable-thresholding (2)."
::= { ty1250CfgNetTable 12 }
ty1250CfgDteTable OBJECT IDENTIFIER ::= { ty1250 4 }
ty1250CfgDteType OBJECT-TYPE
SYNTAX INTEGER
{
v35 (2),
rs449 (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Dte channel type identifies the electrical
specification of the interface. Read-only."
::= { ty1250CfgDteTable 1 }
ty1250CfgDteClockInvert OBJECT-TYPE
SYNTAX INTEGER
{
normal-dte-clock (1),
invert-dte-clock (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Clock Inversion, invert-dte-clock (2), can be
used to solve out of phase timing problems on
DTE link. normal-dte-clock (1) can be used in
most cases."
::= { ty1250CfgDteTable 5 }
ty1250CfgDteTiming OBJECT-TYPE
SYNTAX INTEGER
{
loop1-timing (1),
loop2-timing (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The DTE channel Timing mode. Use loop2-timing (2)
when in doubt."
::= { ty1250CfgDteTable 6 }
ty1250CfgDialTable OBJECT IDENTIFIER ::= { ty1250 5 }
ty1250CfgDialButton OBJECT-TYPE
SYNTAX INTEGER
{
enable-button (1),
disable-button (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, Enables/Disables
the button on front of unit. This button can
used to manual answer an incomming call, or
dial out the default number. The valid values
are enable-button (1) and disable-button (2)."
::= { ty1250CfgDialTable 1 }
ty1250CfgDialDtr OBJECT-TYPE
SYNTAX INTEGER
{
enable-dtr (1),
disable-dtr (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, Enables/Disables
dialing on DTR signal transition. Valid values
enable-dtr (1) and disable-dtr (2)."
::= { ty1250CfgDialTable 2 }
ty1250CfgDialRtsDisc OBJECT-TYPE
SYNTAX INTEGER
{
enable-rts (1),
disable-rts (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, Enables/Disables
disconnecting on RTS signal transition. Valid
values are enable-rts (1) and disable-rts (2)."
::= { ty1250CfgDialTable 3 }
ty1250CfgDialRi OBJECT-TYPE
SYNTAX INTEGER
{
enable-ri (1),
disable-ri (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"In switched applications, Enables/Disables
incoming call notification to DTE via RI
signal. Valid values are enable-ri (1)
and disable-ri (2)."
::= { ty1250CfgDialTable 4 }
ty1250CfgMaintTable OBJECT-TYPE
SYNTAX SEQUENCE OF Ty1250CfgMaintEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Maintenance Port Configuration table contains
parameters for the Maintenance ports on the
1250. The Terminal Port is Index=1; SLIP port is 2"
::= { ty1250 6 }
ty1250CfgMaintEntry OBJECT-TYPE
SYNTAX Ty1250CfgMaintEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Maintenance Port Configuration Object"
INDEX { ty1250CfgMaintIndex }
::= { ty1250CfgMaintTable 1 }
Ty1250CfgMaintEntry ::=
SEQUENCE
{
ty1250CfgMaintIndex INTEGER (1..2),
ty1250CfgMaintMode INTEGER,
ty1250CfgMaintBaud INTEGER,
ty1250CfgMaintDataBits INTEGER,
ty1250CfgMaintStopBits INTEGER,
ty1250CfgMaintParity INTEGER,
ty1250CfgMaintFlowCtrl INTEGER
}
ty1250CfgMaintIndex OBJECT-TYPE
SYNTAX INTEGER (1..2)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Maintenance port under consideration. On the
1250, the Terminal Port is Index=1; SLIP port is 2."
::= { ty1250CfgMaintEntry 1 }
ty1250CfgMaintMode OBJECT-TYPE
SYNTAX INTEGER
{
ascii-vt100 (4),
slip (7),
cslip (8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Mode for this Maintenance Port. Values include
ascii-vt100 (4), slip (7), and cslip (8)."
::= { ty1250CfgMaintEntry 2 }
ty1250CfgMaintBaud OBJECT-TYPE
SYNTAX INTEGER
{
baud-2400 (2),
baud-9600 (4),
baud-19200 (5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Baud rate for this Maintenance port. Values are
baud-2400 (2), baud-9600 (4), baud-19200 (5)."
::= { ty1250CfgMaintEntry 3 }
ty1250CfgMaintDataBits OBJECT-TYPE
SYNTAX INTEGER
{
databits-7 (1),
databits-8 (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Databits for this Maintenance port. Values
are databits-7 (1) and databits-8 (2)."
::= { ty1250CfgMaintEntry 4 }
ty1250CfgMaintStopBits OBJECT-TYPE
SYNTAX INTEGER
{
stopbits-1 (1),
stopbits-1-5 (2),
stopbits-2 (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of Stopbits for this Maintenance port.
Values are stopbits-1 (1), stopbits-1-5 (2),
and stopbits-2 (3)."
::= { ty1250CfgMaintEntry 5 }
ty1250CfgMaintParity OBJECT-TYPE
SYNTAX INTEGER
{
no-parity (1),
odd-parity (2),
even-parity (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Parity for this Maintenance port. Values are
no-parity (1), odd-parity (2), even-parity (3)."
::= { ty1250CfgMaintEntry 6 }
ty1250CfgMaintFlowCtrl OBJECT-TYPE
SYNTAX INTEGER
{
no-flow-control (1),
software-flow-control (2),
hardware-flow-control (3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Flow Control for this Maintenance port. Values
are no-flow-control (1), software-flow-control (2),
and hardware-flow-control (3)."
::= { ty1250CfgMaintEntry 7 }
ty1250CfgSlipTable OBJECT IDENTIFIER ::= { ty1250 8 }
ty1250CfgSlipMyIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address for this node."
::= { ty1250CfgSlipTable 1 }
ty1250CfgSlipPeerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address for other end of slip connection."
::= { ty1250CfgSlipTable 2 }
ty1250CfgSlipMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP Network Mask (eg 255.255.255.0) for the
SLIP link."
::= { ty1250CfgSlipTable 3 }
ty1250CfgSlipMaxMTU OBJECT-TYPE
SYNTAX INTEGER (1..1024)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Maximum Transmission Unit is the size of the
largest IP packet supported. This value should
be set to the lowest value supported by any
equipment in the transmission path. A size of
1006 (including header) is suggested."
::= { ty1250CfgSlipTable 4 }
ty1250CfgSnmpTable OBJECT IDENTIFIER ::= { ty1250 14 }
ty1250CfgSnmpManagerIP OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The IP address for the SNMP manager to receive
this node's TRAPs."
::= { ty1250CfgSnmpTable 1 }
ty1250CfgTelnetTable OBJECT IDENTIFIER ::= { ty1250 17 }
ty1250CfgTelnetEnable OBJECT-TYPE
SYNTAX INTEGER
{
enable-telnet (1),
disable-telnet (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables/Disables the telnet feature.
Valid values are enable-telnet (1)
and disable-telnet (2)."
::= { ty1250CfgTelnetTable 1 }
ty1250CfgTelnetAutoLogOut OBJECT-TYPE
SYNTAX INTEGER
{
autologout-at-15-minutes (1),
disable-autologout (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables/Disables the telnet auto-logout, logging out
the user after a certain length of idle time.
Valid values are autologout-at-15-minutes (1)
and disable-autologout (2)."
::= { ty1250CfgTelnetTable 2 }
ty1250CallTable OBJECT IDENTIFIER ::= { ty1250 9 }
ty1250CallState OBJECT-TYPE
SYNTAX INTEGER
{
connect (1),
disconnect (2),
answer (3)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Call-related actions:
a: Connect (initiate a call),
b: Disconnect (terminate a call)
c: Answer (answer an incoming call)."
::= { ty1250CallTable 4 }
ty1250CallStatus OBJECT-TYPE
SYNTAX INTEGER
{
none (1),
idle (2),
dialing (3),
busy (4),
waiting-for-redial (5),
redialing (6),
active (7),
incoming-call (8),
line-in-maintenance (253),
line-down (254)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The call status is shown here."
::= { ty1250CallTable 1 }
ty1250CallNumber OBJECT-TYPE
SYNTAX DisplayString (SIZE(0..20))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The last phone number dialed out."
::= { ty1250CallTable 2 }
ty1250CallUpTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds the call has been up."
::= { ty1250CallTable 3 }
ty1250DiagUnitTable OBJECT IDENTIFIER ::= { ty1250 10 }
ty1250DiagUnitLocLoop OBJECT-TYPE
SYNTAX INTEGER
{
enable-loopback-mode (1),
disable-loopback-mode (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables the operator to control and examine the
UNIT local loopback. This loopback occurs on
all network ports transmit and receive logic.
The unit will transmit DTE data out to the network
as normal, and will also loop DTE data back to
the DTE."
::= { ty1250DiagUnitTable 1 }
ty1250DiagUnitReset OBJECT-TYPE
SYNTAX INTEGER
{
reset-unit (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Enables the operator to remotely reset the unit.
Using this command will cause the unit to terminate
all its connections and drop data."
::= { ty1250DiagUnitTable 2 }
ty1250DiagNetTable OBJECT IDENTIFIER ::= { ty1250 11 }
ty1250DiagNetLineStatus OBJECT-TYPE
SYNTAX INTEGER
{
in-sync (1),
out-of-service (2),
out-of-frame (3),
bpv-threshold-failure (4),
loss-of-signal (5),
simplex-current-loopback (6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Current status of the physical interface.
Your network carrier can send Out-of-Service
or Maintenance Mode codes."
::= { ty1250DiagNetTable 1 }
ty1250DiagNetLclLpbk OBJECT-TYPE
SYNTAX INTEGER
{
enable-loopback-mode (1),
disable-loopback-mode (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enables the operator to control and examine the
network local loopback. This loopback occurs on
the net side of the local transmit and receive
logic. The unit continues to receive data from
the network and also loops received data back to
the network."
::= { ty1250DiagNetTable 2 }
ty1250DiagNetRmtLpbk OBJECT-TYPE
SYNTAX INTEGER
{
no-loop-from-remote (1),
simplex-current-loop (2),
non-latching-loop (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Enables the operator to examine (ONLY) the
status of network loopbacks placed by external
equipment, such as your local CO. These loopbacks
will loop received network data back out the
network, disconnecting the DTE completely."
::= { ty1250DiagNetTable 3 }
ty1250DiagDteTable OBJECT IDENTIFIER ::= { ty1250 12 }
ty1250DiagDteSigRTS OBJECT-TYPE
SYNTAX INTEGER
{
rts-signal-on (1),
rts-signal-off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Dte Channel RTS signal. Values are
rts-signal-on (1) and rts-signal-off (2)."
::= { ty1250DiagDteTable 1 }
ty1250DiagDteSigDTR OBJECT-TYPE
SYNTAX INTEGER
{
dtr-signal-on (1),
dtr-signal-off (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Dte Channel DTR signal.
Values are dtr-signal-on (1) and dtr-signal-off (2)."
::= { ty1250DiagDteTable 2 }
ty1250DiagDteLclLpbk OBJECT-TYPE
SYNTAX INTEGER
{
enable-loopback-mode (1),
disable-loopback-mode (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This selection displays the status or controls the
Local DTE Channel Loopback for the selected channel.
This is will loop DTE data back towards the DTE interface
in addition to passing it on to the network."
::= { ty1250DiagDteTable 5 }
ty1250DiagDteV54Lpbk OBJECT-TYPE
SYNTAX INTEGER
{
loopback-enable (1),
loopback-disable (2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This selection displays the status of the DTE Channel
V.54 Loopback for the channel. This loopback is
initiated by the remote node, causing this node to loop
data back to the remote node."
::= { ty1250DiagDteTable 6 }
ty1250DiagDteRmtV54Lpbk OBJECT-TYPE
SYNTAX INTEGER
{
transmit-code-enable (3),
transmit-code-disable (4)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"This selection controls the DTE Channel V.54 Remote Loopback.
Transmit-code-enable (3) will cause the node to transmit
a V.54 code to the remote node which will then loop
received data back to this node. transmit-code-disable (4)
will transmit the disable code."
::= { ty1250DiagDteTable 13 }
ty1250DiagDteBerState OBJECT-TYPE
SYNTAX INTEGER
{
start-bert-test (1),
stop-bert-test (2),
inject-error-bert-test (3),
clear-error-bert-test (4)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"BERT test related actions:
a: Starts a BERT test on a channel,
b: Stops a BERT test on a channel,
c: Inject Errors while the BERT test is running,
d: Clears BERT test errors."
::= { ty1250DiagDteTable 7 }
ty1250DiagDteBerStatus OBJECT-TYPE
SYNTAX INTEGER
{
bert-off (1),
bert-out-of-sync (2),
bert-in-sync (3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the current BERT test sync status."
::= { ty1250DiagDteTable 8 }
ty1250DiagDteBerErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the number of errors detected in Bert Test."
::= { ty1250DiagDteTable 9 }
ty1250DiagDteBerErrSec OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the number of seconds containing errors
in BERT Test."
::= { ty1250DiagDteTable 10 }
ty1250DiagDteBerTimeElaps OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Elapsed time since BERT test was started or cleared."
::= { ty1250DiagDteTable 11 }
ty1250DiagDteBerResyncs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Displays the number of times BERT test has synched up
on the pattern."
::= { ty1250DiagDteTable 12 }
ty1250StatsDteTable OBJECT IDENTIFIER ::= { ty1250 15 }
ty1250StatsDteTxByteCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The statistic counting the number of bytes transmitted
on the DTE channel."
::= { ty1250StatsDteTable 1 }
ty1250StatsDteRxByteCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The statistic counting the number of bytes received
on the DTE channel."
::= { ty1250StatsDteTable 2 }
ty1250StatsDteClearStats OBJECT-TYPE
SYNTAX INTEGER
{
clear-statistics (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Allows the user to zero out all the statistics in
the DTE statistics table."
::= { ty1250StatsDteTable 3 }
ty1250StatsNetTable OBJECT IDENTIFIER ::= { ty1250 16 }
ty1250StatsNetLoopLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The statistic that estimates line attentuation
on the network channel."
::= { ty1250StatsNetTable 1 }
ty1250StatsNetBpvCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The statistic counting the number of BPV errors
on the network channel."
::= { ty1250StatsNetTable 2 }
ty1250StatsNetTxByteCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The statistic counting the number of bytes transmitted
on the network channel."
::= { ty1250StatsNetTable 3 }
ty1250StatsNetRxByteCount OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The statistic counting the number of bytes received
on the network channel."
::= { ty1250StatsNetTable 4 }
ty1250StatsNetClearStats OBJECT-TYPE
SYNTAX INTEGER
{
clear-statistics (1)
}
ACCESS write-only
STATUS mandatory
DESCRIPTION
"Allows the user to zero out all the statistics in
the network statistics table."
::= { ty1250StatsNetTable 5 }
ty1250AlarmType OBJECT-TYPE
SYNTAX INTEGER
{
line-failure (1),
line-in-service (2),
connected (3),
connect-failure (4),
incoming-call (5),
disconnected (6),
bad-config-in-set (7),
config-local-update (8),
bpv-threshold-exceeded (9),
bpv-threshold-acceptable (10),
local-unit-loopback-enabled (11),
local-unit-loopback-disabled (12),
local-network-loopback-enabled (13),
local-network-loopback-disabled (14),
remote-network-simplex-loopback-enabled (15),
remote-network-simplex-loopback-disabled (16),
remote-network-non-latching-loopback-enabled (17),
remote-network-non-latching-loopback-disabled (18),
v54-loop-up-initiated (19),
v54-loop-down-completed (20),
v54-loopback-enabled-by-remote (21),
v54-loopback-disabled-by-remote (22),
bert-test-pattern-initiated (23),
bert-test-pattern-completed (24),
local-dte-loopback-enabled (25),
local-dte-loopback-disabled (26),
local-unit-loopback-failure (27),
local-network-loopback-failure (28),
bert-test-pattern-failure (29),
local-dte-loopback-failure (30),
v54-loopback-failure (31)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The type of alarms that are generated on the node"
::= { ty1250 13 }
ty1250Trap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"A ty1250Trap trap signifies that the
sending node had its `ty1250AlarmType`
variable modified."
::= 0
ty1250LineFailureTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"The line has failed."
::= 1
ty1250LineInServiceTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"The line is back in service."
::= 2
ty1250ConnectedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"The 1250 unit is connected."
::= 3
ty1250ConnectFailureTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"The attempted connection failed."
::= 4
ty1250IncomingCallTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Incoming call."
::= 5
ty1250DisconnectedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Disconnected."
::= 6
ty1250BadConfigTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"The configuration specified in the
SET command was bad. SET failed."
::= 7
ty1250LocalConfigTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"The configuration has been changed
by a means other than SNMP."
::= 8
ty1250BPVThresholdExceededTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"BPV threshold exceeded."
::= 9
ty1250BPVThresholdAcceptableTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"BPV threshold acceptable."
::= 10
ty1250LocalUnitLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Local unit loopback enabled."
::= 11
ty1250LocalUnitLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Local unit loopback disabled."
::= 12
ty1250LocalNetLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Local network loopback enabled."
::= 13
ty1250LocalNetLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Local network loopback disabled."
::= 14
ty1250SimplexCurrentLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Simplex current loopback enabled."
::= 15
ty1250SimplexCurrentLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Simplex current loopback disabled."
::= 16
ty1250NonLatchingLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Nonlatching loopback enabled."
::= 17
ty1250NonLatchingLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Nonlatching loopback disabled."
::= 18
ty1250V54LoopUpInitiatedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Starting to loop up a V54 loopback on the remote unit."
::= 19
ty1250V54LoopDownCompletedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Completed the loop down of a V54 loopback on the remote unit."
::= 20
ty1250V54LoopbackEnabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"V54 loopback enabled by remote unit."
::= 21
ty1250V54LoopbackDisabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"V54 loopback disabled by remote unit."
::= 22
ty1250BertInitiatedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"BERT test pattern initiated."
::= 23
ty1250BertCompletedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"BERT test pattern completed."
::= 24
ty1250LocalDteLoopbackEnabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Local DTE loopback enabled."
::= 25
ty1250LocalDteLoopbackDisabledTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Local DTE loopback disabled."
::= 26
ty1250LocalUnitLoopbackFailedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Unable to do a local unit loopback."
::= 27
ty1250LocalNetLoopbackFailedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Unable to do a local network loopback."
::= 28
ty1250BertFailedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Unable to do a BERT."
::= 29
ty1250LocalDteLoopbackFailedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Unable to do a local DTE loopback."
::= 30
ty1250V54LoopbackFailedTrap TRAP-TYPE
ENTERPRISE ty1250
VARIABLES
{
ty1250AlarmType
}
DESCRIPTION
"Unable to do a V54 loopback."
::= 31
END