Wellfleet-DS1-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Counter, Gauge, TimeTicks, Opaque, enterprises, mgmt
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString, mib-2
FROM RFC1213-MIB
wfDs1Group
FROM Wellfleet-COMMON-MIB;
wfDs1Config OBJECT-TYPE
SYNTAX SEQUENCE OF WfDs1ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 Configuration table"
::= { wfDs1Group 1 }
wfDs1ConfigEntry OBJECT-TYPE
SYNTAX WfDs1ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS1 configuration objects; wfDs1LineIndex
corresponds to Wellfleet circuit number"
INDEX { wfDs1LineIndex }
::= { wfDs1Config 1 }
WfDs1ConfigEntry ::= SEQUENCE {
wfDs1LineIndex
INTEGER,
wfDs1TimeElapsed
INTEGER,
wfDs1ValidIntervals
INTEGER,
wfDs1LineType
INTEGER,
wfDs1ZeroCoding
INTEGER,
wfDs1SendCode
INTEGER,
wfDs1CircuitIdentifier
DisplayString,
wfDs1LoopbackConfig
INTEGER,
wfDs1LineStatus
INTEGER
}
wfDs1LineIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDs1ConfigEntry 1 }
wfDs1TimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..900 seconds within the current 15-minute interval"
::= { wfDs1ConfigEntry 2 }
wfDs1ValidIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0..96 previous intervals that valid data
were collected. This is 96 unless the CSU
device was brought on line within the last 24
hours."
::= { wfDs1ConfigEntry 3 }
wfDs1LineType OBJECT-TYPE
SYNTAX INTEGER {
ds1ansi-esf(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the variety of DS1 implementing this circuit"
::= { wfDs1ConfigEntry 4 }
wfDs1ZeroCoding OBJECT-TYPE
SYNTAX INTEGER {
ds1b8zs(2),
ds1zbtsi(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the variety of Zero Code Suppression used on the link"
::= { wfDs1ConfigEntry 5 }
wfDs1SendCode OBJECT-TYPE
SYNTAX INTEGER {
ds1sendnocode(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the type of code being sent across the DS1 circuit by
the CSU"
::= { wfDs1ConfigEntry 6 }
wfDs1CircuitIdentifier OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the transmission vendor's circuit identifier"
::= { wfDs1ConfigEntry 7 }
wfDs1LoopbackConfig OBJECT-TYPE
SYNTAX INTEGER {
ds1noloop(1),
ds1mgrpayloadloop(2),
ds1mgrlineloop(3),
ds1netreqpayloadloop(4),
ds1netreqlineloop(5),
ds1otherloop(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the loopback state of the CSU"
::= { wfDs1ConfigEntry 8 }
wfDs1LineStatus OBJECT-TYPE
SYNTAX INTEGER {
ds1noalarm(1),
ds1farendalarm(2),
ds1alarmindicationsignal(4),
ds1lossofframe(8),
ds1lossofsignal(16),
ds1loopbackstate(32)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the state of the DS1 line"
::= { wfDs1ConfigEntry 9 }
wfDs1Current OBJECT-TYPE
SYNTAX SEQUENCE OF WfDs1CurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 Current table"
::= { wfDs1Group 2 }
wfDs1CurrentEntry OBJECT-TYPE
SYNTAX WfDs1CurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS1 current objects - wfDs1CurrentIndex
corresponds to Wellfleet circuit number"
INDEX { wfDs1CurrentIndex }
::= { wfDs1Current 1 }
WfDs1CurrentEntry ::= SEQUENCE {
wfDs1CurrentIndex
INTEGER,
wfDs1CurrentESs
Counter,
wfDs1CurrentSESs
Counter,
wfDs1CurrentSEFs
Counter,
wfDs1CurrentUASs
Counter,
wfDs1CurrentBPVs
Counter,
wfDs1CurrentCVs
Counter
}
wfDs1CurrentIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDs1CurrentEntry 1 }
wfDs1CurrentESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of errored seconds in the current interval"
::= { wfDs1CurrentEntry 2 }
wfDs1CurrentSESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of severely errored seconds in the
current interval"
::= { wfDs1CurrentEntry 3 }
wfDs1CurrentSEFs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of severely errored framing seconds in the current
interval"
::= { wfDs1CurrentEntry 4 }
wfDs1CurrentUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of unavailable seconds in the current interval"
::= { wfDs1CurrentEntry 5 }
wfDs1CurrentBPVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of bipolar violations in the current interval"
::= { wfDs1CurrentEntry 6 }
wfDs1CurrentCVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of code violation error events in the
current interval"
::= { wfDs1CurrentEntry 7 }
wfDs1Interval OBJECT-TYPE
SYNTAX SEQUENCE OF WfDs1IntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 Interval table"
::= { wfDs1Group 3 }
wfDs1IntervalEntry OBJECT-TYPE
SYNTAX WfDs1IntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS1 interval objects - wfDs1IntervalIndex
corresponds to Wellfleet circuit number,
wfDs1IntervalNumber is the numbered previous
15-minute interval"
INDEX { wfDs1IntervalIndex,
wfDs1IntervalNumber }
::= { wfDs1Interval 1 }
WfDs1IntervalEntry ::= SEQUENCE {
wfDs1IntervalIndex
INTEGER,
wfDs1IntervalNumber
INTEGER,
wfDs1IntervalESs
Gauge,
wfDs1IntervalSESs
Gauge,
wfDs1IntervalSEFs
Gauge,
wfDs1IntervalUASs
Gauge,
wfDs1IntervalBPVs
Gauge,
wfDs1IntervalCVs
Gauge
}
wfDs1IntervalIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDs1IntervalEntry 1 }
wfDs1IntervalNumber OBJECT-TYPE
SYNTAX INTEGER(1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..96 where 1 is the most recent 15-minute interval and 96 is
the least"
::= { wfDs1IntervalEntry 2 }
wfDs1IntervalESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of errored seconds in the specified interval"
::= { wfDs1IntervalEntry 3 }
wfDs1IntervalSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of severely errored seconds in the specified
interval"
::= { wfDs1IntervalEntry 4 }
wfDs1IntervalSEFs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of severely errored framing seconds in the specified
interval"
::= { wfDs1IntervalEntry 5 }
wfDs1IntervalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of unavailable seconds in the specified interval"
::= { wfDs1IntervalEntry 6 }
wfDs1IntervalBPVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of bipolar violations in the specified interval"
::= { wfDs1IntervalEntry 7 }
wfDs1IntervalCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of code violation error events in the
specified interval"
::= { wfDs1IntervalEntry 8 }
wfDs1Total OBJECT-TYPE
SYNTAX SEQUENCE OF WfDs1TotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 Total table"
::= { wfDs1Group 4 }
wfDs1TotalEntry OBJECT-TYPE
SYNTAX WfDs1TotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS1 total objects - wfDs1TotalIndex
corresponds to Wellfleet circuit number"
INDEX { wfDs1TotalIndex }
::= { wfDs1Total 1 }
WfDs1TotalEntry ::= SEQUENCE {
wfDs1TotalIndex
INTEGER,
wfDs1TotalESs
Gauge,
wfDs1TotalSESs
Gauge,
wfDs1TotalSEFs
Gauge,
wfDs1TotalUASs
Gauge,
wfDs1TotalBPVs
Gauge,
wfDs1TotalCVs
Gauge
}
wfDs1TotalIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDs1TotalEntry 1 }
wfDs1TotalESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of errored seconds"
::= { wfDs1TotalEntry 2 }
wfDs1TotalSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of severely errored seconds"
::= { wfDs1TotalEntry 3 }
wfDs1TotalSEFs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of severely errored framing seconds"
::= { wfDs1TotalEntry 4 }
wfDs1TotalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total number of unavailable seconds"
::= { wfDs1TotalEntry 5 }
wfDs1TotalBPVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of bipolar violations"
::= { wfDs1TotalEntry 6 }
wfDs1TotalCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of code violation error events"
::= { wfDs1TotalEntry 7 }
wfDs1FeCurrent OBJECT-TYPE
SYNTAX SEQUENCE OF WfDs1FeCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 Far End Current table"
::= { wfDs1Group 5 }
wfDs1FeCurrentEntry OBJECT-TYPE
SYNTAX WfDs1FeCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS1 far end current objects
wfDs1CurrentIndex corresponds to Wellfleet circuit
number"
INDEX { wfDs1FeCurrentIndex }
::= { wfDs1FeCurrent 1 }
WfDs1FeCurrentEntry ::= SEQUENCE {
wfDs1FeCurrentIndex
INTEGER,
wfDs1FeCurrentESs
Counter,
wfDs1FeCurrentSESs
Counter,
wfDs1FeCurrentSEFs
Counter,
wfDs1FeCurrentBPVs
Counter,
wfDs1FeCurrentCVs
Counter
}
wfDs1FeCurrentIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDs1FeCurrentEntry 1 }
wfDs1FeCurrentESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of errored seconds in the current interval"
::= { wfDs1FeCurrentEntry 2 }
wfDs1FeCurrentSESs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of severely errored seconds in the
current interval"
::= { wfDs1FeCurrentEntry 3 }
wfDs1FeCurrentSEFs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of severely errored framing seconds in the current
interval"
::= { wfDs1FeCurrentEntry 4 }
wfDs1FeCurrentBPVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of bipolar violations in the current interval"
::= { wfDs1FeCurrentEntry 5 }
wfDs1FeCurrentCVs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of code violation error events in the
current interval"
::= { wfDs1FeCurrentEntry 6 }
wfDs1FeInterval OBJECT-TYPE
SYNTAX SEQUENCE OF WfDs1FeIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 Far End Interval table"
::= { wfDs1Group 6 }
wfDs1FeIntervalEntry OBJECT-TYPE
SYNTAX WfDs1FeIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS1 far end interval objects -
wfDs1FeIntervalIndex corresponds to Wellfleet circuit
number, wfDs1FeIntervalNumber is the numbered
previous 15-minute interval"
INDEX { wfDs1FeIntervalIndex,
wfDs1FeIntervalNumber }
::= { wfDs1FeInterval 1 }
WfDs1FeIntervalEntry ::= SEQUENCE {
wfDs1FeIntervalIndex
INTEGER,
wfDs1FeIntervalNumber
INTEGER,
wfDs1FeIntervalESs
Gauge,
wfDs1FeIntervalSESs
Gauge,
wfDs1FeIntervalSEFs
Gauge,
wfDs1FeIntervalBPVs
Gauge,
wfDs1FeIntervalCVs
Gauge
}
wfDs1FeIntervalIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDs1FeIntervalEntry 1 }
wfDs1FeIntervalNumber OBJECT-TYPE
SYNTAX INTEGER(1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..96 where 1 is the most recent 15-minute interval and 96 is
the least"
::= { wfDs1FeIntervalEntry 2 }
wfDs1FeIntervalESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of errored seconds in the specified interval"
::= { wfDs1FeIntervalEntry 3 }
wfDs1FeIntervalSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of severely errored seconds in the specified
interval"
::= { wfDs1FeIntervalEntry 4 }
wfDs1FeIntervalSEFs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of severely errored framing seconds in the specified
interval"
::= { wfDs1FeIntervalEntry 5 }
wfDs1FeIntervalBPVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of bipolar violations in the specified interval"
::= { wfDs1FeIntervalEntry 6 }
wfDs1FeIntervalCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of code violation error events in the
specified interval"
::= { wfDs1FeIntervalEntry 7 }
wfDs1FeTotal OBJECT-TYPE
SYNTAX SEQUENCE OF WfDs1FeTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS1 Far End Total table"
::= { wfDs1Group 7 }
wfDs1FeTotalEntry OBJECT-TYPE
SYNTAX WfDs1FeTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS1 far end total objects - wfDs1FeTotalIndex
corresponds to Wellfleet circuit number"
INDEX { wfDs1FeTotalIndex }
::= { wfDs1FeTotal 1 }
WfDs1FeTotalEntry ::= SEQUENCE {
wfDs1FeTotalIndex
INTEGER,
wfDs1FeTotalESs
Gauge,
wfDs1FeTotalSESs
Gauge,
wfDs1FeTotalSEFs
Gauge,
wfDs1FeTotalBPVs
Gauge,
wfDs1FeTotalCVs
Gauge
}
wfDs1FeTotalIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDs1FeTotalEntry 1 }
wfDs1FeTotalESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of errored seconds"
::= { wfDs1FeTotalEntry 2 }
wfDs1FeTotalSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of severely errored seconds"
::= { wfDs1FeTotalEntry 3 }
wfDs1FeTotalSEFs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of severely errored framing seconds"
::= { wfDs1FeTotalEntry 4 }
wfDs1FeTotalBPVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of bipolar violations"
::= { wfDs1FeTotalEntry 5 }
wfDs1FeTotalCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of code violation error events"
::= { wfDs1FeTotalEntry 6 }
END