Wellfleet-DSX3-MIB DEFINITIONS ::= BEGIN
IMPORTS
Gauge
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
wfDsx3Group
FROM Wellfleet-COMMON-MIB;
wfDsx3ConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Configuration table"
::= { wfDsx3Group 1 }
wfDsx3ConfigEntry OBJECT-TYPE
SYNTAX WfDsx3ConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 configuration objects; wfDsx3LineIndex
corresponds to Wellfleet circuit number"
INDEX { wfDsx3LineIndex }
::= { wfDsx3ConfigTable 1 }
WfDsx3ConfigEntry ::= SEQUENCE {
wfDsx3LineIndex
INTEGER,
wfDsx3IfIndex
INTEGER,
wfDsx3TimeElapsed
INTEGER,
wfDsx3ValidIntervals
INTEGER,
wfDsx3LineType
INTEGER,
wfDsx3LineCoding
INTEGER,
wfDsx3SendCode
INTEGER,
wfDsx3CircuitIdentifier
DisplayString,
wfDsx3LoopbackConfig
INTEGER,
wfDsx3LineStatus
INTEGER,
wfDsx3TransmitClockSource
INTEGER
}
wfDsx3LineIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3ConfigEntry 1 }
wfDsx3IfIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this is value of ifIndex from the Interfaces table of
MIB II (RFC 1213)."
::= { wfDsx3ConfigEntry 2 }
wfDsx3TimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0..899 seconds elapsed within the current 15-minute interval"
::= { wfDsx3ConfigEntry 3 }
wfDsx3ValidIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"0..96 previous intervals that valid data were collected.
This is 96 unless the device was brought on line within
the last 24 hours."
::= { wfDsx3ConfigEntry 4 }
wfDsx3LineType OBJECT-TYPE
SYNTAX INTEGER {
ds3other(1),
ds3m23(2),
ds3syntran(3),
ds3cbitparity(4),
ds3clearchannel(5),
e3other(6),
e3framed(7),
e3plcp(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the variety of DS3/E3 application implementing this circuit"
::= { wfDsx3ConfigEntry 5 }
wfDsx3LineCoding OBJECT-TYPE
SYNTAX INTEGER {
other(1),
b3zs(2),
hdb3(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the variety of Zero Code Suppression used on the link"
::= { wfDsx3ConfigEntry 6 }
wfDsx3SendCode OBJECT-TYPE
SYNTAX INTEGER {
nocode(1),
linecode(2),
payloadcode(3),
resetcode(4),
ds1loopcode(5),
testpattern(6)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the type of code being sent across the DS3/E3 circuit by
the device"
::= { wfDsx3ConfigEntry 7 }
wfDsx3CircuitIdentifier OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the transmission vendor's circuit identifier"
::= { wfDsx3ConfigEntry 8 }
wfDsx3LoopbackConfig OBJECT-TYPE
SYNTAX INTEGER {
noloop(1),
payloadloop(2),
lineloop(3),
otherloop(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the loopback configuration of the DS3/E3 interface"
::= { wfDsx3ConfigEntry 9 }
wfDsx3LineStatus OBJECT-TYPE
SYNTAX INTEGER {
noalarm(1),
rcrai(2),
txrai(4),
rcais(8),
txais(16),
lof(32),
los(64),
loopback(128),
rctestcode(256),
otherfailure(512)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the status of the DS3/E3 line"
::= { wfDsx3ConfigEntry 10 }
wfDsx3TransmitClockSource OBJECT-TYPE
SYNTAX INTEGER {
looptiming(1),
localtiming(2),
throughtiming(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the source of Transmit Clock for the DS3/E3 interface"
::= { wfDsx3ConfigEntry 11 }
wfDsx3CurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3CurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Current table"
::= { wfDsx3Group 2 }
wfDsx3CurrentEntry OBJECT-TYPE
SYNTAX WfDsx3CurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 current objects - wfDsx3CurrentIndex
corresponds to Wellfleet circuit number"
INDEX { wfDsx3CurrentIndex }
::= { wfDsx3CurrentTable 1 }
WfDsx3CurrentEntry ::= SEQUENCE {
wfDsx3CurrentIndex
INTEGER,
wfDsx3CurrentPESs
Gauge,
wfDsx3CurrentPSESs
Gauge,
wfDsx3CurrentSEFSs
Gauge,
wfDsx3CurrentUASs
Gauge,
wfDsx3CurrentLCVs
Gauge,
wfDsx3CurrentPCVs
Gauge,
wfDsx3CurrentLESs
Gauge,
wfDsx3CurrentCCVs
Gauge,
wfDsx3CurrentCESs
Gauge,
wfDsx3CurrentCSESs
Gauge,
wfDsx3CurrentSASs
Gauge,
wfDsx3CurrentAISSs
Gauge,
wfDsx3CurrentFCs
Gauge,
wfDsx3CurrentTimeElapsed
INTEGER,
wfDsx3CurrentValidIntervals
INTEGER,
wfDsx3CurrentValidFlag
INTEGER
}
wfDsx3CurrentIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3CurrentEntry 1 }
wfDsx3CurrentPESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Errored Seconds in the current interval"
::= { wfDsx3CurrentEntry 2 }
wfDsx3CurrentPSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Severely Errored Seconds in the
current interval"
::= { wfDsx3CurrentEntry 3 }
wfDsx3CurrentSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Severely Errored Framing Seconds in the
current interval"
::= { wfDsx3CurrentEntry 4 }
wfDsx3CurrentUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds in the current interval"
::= { wfDsx3CurrentEntry 5 }
wfDsx3CurrentLCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Coding Violations in the current interval"
::= { wfDsx3CurrentEntry 6 }
wfDsx3CurrentPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Coding Violations in the current interval"
::= { wfDsx3CurrentEntry 7 }
wfDsx3CurrentLESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Errored Seconds in the current interval"
::= { wfDsx3CurrentEntry 8 }
wfDsx3CurrentCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Coding Violations in the current interval"
::= { wfDsx3CurrentEntry 9 }
wfDsx3CurrentCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Errored Seconds in the current interval"
::= { wfDsx3CurrentEntry 10 }
wfDsx3CurrentCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Severely Errored Seconds
in the current interval"
::= { wfDsx3CurrentEntry 11 }
wfDsx3CurrentSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the current interval"
::= { wfDsx3CurrentEntry 12 }
wfDsx3CurrentAISSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more AIS defect
in the current interval"
::= { wfDsx3CurrentEntry 13 }
wfDsx3CurrentFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the current interval"
::= { wfDsx3CurrentEntry 14 }
wfDsx3CurrentTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of seconds since the beginning of
the far end current interval"
::= { wfDsx3CurrentEntry 15 }
wfDsx3CurrentValidIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of previous far end intervals for
which valid data is available"
::= { wfDsx3CurrentEntry 16 }
wfDsx3CurrentValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3CurrentEntry 17 }
wfDsx3IntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3IntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Interval table"
::= { wfDsx3Group 3 }
wfDsx3IntervalEntry OBJECT-TYPE
SYNTAX WfDsx3IntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 interval objects - wfDsx3IntervalIndex
corresponds to Wellfleet circuit number,
wfDsx3IntervalNumber is the numbered previous
15-minute interval"
INDEX { wfDsx3IntervalIndex,
wfDsx3IntervalNumber }
::= { wfDsx3IntervalTable 1 }
WfDsx3IntervalEntry ::= SEQUENCE {
wfDsx3IntervalIndex
INTEGER,
wfDsx3IntervalNumber
INTEGER,
wfDsx3IntervalPESs
Gauge,
wfDsx3IntervalPSESs
Gauge,
wfDsx3IntervalSEFSs
Gauge,
wfDsx3IntervalUASs
Gauge,
wfDsx3IntervalLCVs
Gauge,
wfDsx3IntervalPCVs
Gauge,
wfDsx3IntervalLESs
Gauge,
wfDsx3IntervalCCVs
Gauge,
wfDsx3IntervalCESs
Gauge,
wfDsx3IntervalCSESs
Gauge,
wfDsx3IntervalSASs
Gauge,
wfDsx3IntervalAISSs
Gauge,
wfDsx3IntervalFCs
Gauge,
wfDsx3IntervalValidFlag
INTEGER
}
wfDsx3IntervalIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3IntervalEntry 1 }
wfDsx3IntervalNumber OBJECT-TYPE
SYNTAX INTEGER(1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..96 where 1 is the most recent 15-minute interval and 96 is
the least"
::= { wfDsx3IntervalEntry 2 }
wfDsx3IntervalPESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Errored Seconds in the specified interval"
::= { wfDsx3IntervalEntry 3 }
wfDsx3IntervalPSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Severely Errored Seconds in the
specified interval"
::= { wfDsx3IntervalEntry 4 }
wfDsx3IntervalSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Severely Errored Framing Seconds in the
specified interval"
::= { wfDsx3IntervalEntry 5 }
wfDsx3IntervalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds in the specified interval"
::= { wfDsx3IntervalEntry 6 }
wfDsx3IntervalLCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Coding Violations in the specified interval"
::= { wfDsx3IntervalEntry 7 }
wfDsx3IntervalPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Coding Violations in the specified interval"
::= { wfDsx3IntervalEntry 8 }
wfDsx3IntervalLESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Errored Seconds in the specified interval"
::= { wfDsx3IntervalEntry 9 }
wfDsx3IntervalCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Coding Violations in the specified interval"
::= { wfDsx3IntervalEntry 10 }
wfDsx3IntervalCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Errored Seconds in the specified interval"
::= { wfDsx3IntervalEntry 11 }
wfDsx3IntervalCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Severely Errored Seconds
in the specified interval"
::= { wfDsx3IntervalEntry 12 }
wfDsx3IntervalSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the specified interval"
::= { wfDsx3IntervalEntry 13 }
wfDsx3IntervalAISSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more AIS defect
in the specified interval"
::= { wfDsx3IntervalEntry 14 }
wfDsx3IntervalFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the specified interval"
::= { wfDsx3IntervalEntry 15 }
wfDsx3IntervalValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3IntervalEntry 16 }
wfDsx3TotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3TotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Total table"
::= { wfDsx3Group 4 }
wfDsx3TotalEntry OBJECT-TYPE
SYNTAX WfDsx3TotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 total objects - wfDsx3TotalIndex
corresponds to Wellfleet circuit number"
INDEX { wfDsx3TotalIndex }
::= { wfDsx3TotalTable 1 }
WfDsx3TotalEntry ::= SEQUENCE {
wfDsx3TotalIndex
INTEGER,
wfDsx3TotalPESs
Gauge,
wfDsx3TotalPSESs
Gauge,
wfDsx3TotalSEFSs
Gauge,
wfDsx3TotalUASs
Gauge,
wfDsx3TotalLCVs
Gauge,
wfDsx3TotalPCVs
Gauge,
wfDsx3TotalLESs
Gauge,
wfDsx3TotalCCVs
Gauge,
wfDsx3TotalCESs
Gauge,
wfDsx3TotalCSESs
Gauge,
wfDsx3TotalSASs
Gauge,
wfDsx3TotalAISSs
Gauge,
wfDsx3TotalFCs
Gauge,
wfDsx3TotalValidFlag
INTEGER
}
wfDsx3TotalIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3TotalEntry 1 }
wfDsx3TotalPESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Errored Seconds in the last 24 hours"
::= { wfDsx3TotalEntry 2 }
wfDsx3TotalPSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Severely Errored Seconds in the
last 24 hours"
::= { wfDsx3TotalEntry 3 }
wfDsx3TotalSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Severely Errored Framing Seconds in the
last 24 hours"
::= { wfDsx3TotalEntry 4 }
wfDsx3TotalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds in the last 24 hours"
::= { wfDsx3TotalEntry 5 }
wfDsx3TotalLCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Coding Violations in the last 24 hours"
::= { wfDsx3TotalEntry 6 }
wfDsx3TotalPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Coding Violations in the last 24 hours"
::= { wfDsx3TotalEntry 7 }
wfDsx3TotalLESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Errored Seconds in the last 24 hours"
::= { wfDsx3TotalEntry 8 }
wfDsx3TotalCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Coding Violations in the last 24 hours"
::= { wfDsx3TotalEntry 9 }
wfDsx3TotalCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Errored Seconds in the last 24 hours"
::= { wfDsx3TotalEntry 10 }
wfDsx3TotalCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Severely Errored Seconds
in the last 24 hours"
::= { wfDsx3TotalEntry 11 }
wfDsx3TotalSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the last 24 hours"
::= { wfDsx3TotalEntry 12 }
wfDsx3TotalAISSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more AIS defect
in the last 24 hours"
::= { wfDsx3TotalEntry 13 }
wfDsx3TotalFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the last 24 hours"
::= { wfDsx3TotalEntry 14 }
wfDsx3TotalValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3TotalEntry 15 }
wfDsx3FarEndConfigTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Far End Configuration table"
::= { wfDsx3Group 5 }
wfDsx3FarEndConfigEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndConfigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 far end config objects -
wfDsx3FarEndLineIndex corresponds to Wellfleet circuit
number"
INDEX { wfDsx3FarEndLineIndex }
::= { wfDsx3FarEndConfigTable 1 }
WfDsx3FarEndConfigEntry ::= SEQUENCE {
wfDsx3FarEndLineIndex
INTEGER,
wfDsx3FarEndEquipCode
DisplayString,
wfDsx3FarEndLocationIDCode
DisplayString,
wfDsx3FarEndFrameIDCode
DisplayString,
wfDsx3FarEndUnitCode
DisplayString,
wfDsx3FarEndFacilityIDCode
DisplayString
}
wfDsx3FarEndLineIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3FarEndConfigEntry 1 }
wfDsx3FarEndEquipCode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"equipment description code - C-bit parity only"
::= { wfDsx3FarEndConfigEntry 2 }
wfDsx3FarEndLocationIDCode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"equipment location code - C-bit parity only"
::= { wfDsx3FarEndConfigEntry 3 }
wfDsx3FarEndFrameIDCode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"code for the equipment location within a building"
::= { wfDsx3FarEndConfigEntry 4 }
wfDsx3FarEndUnitCode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"code for the equipment location within a bay"
::= { wfDsx3FarEndConfigEntry 5 }
wfDsx3FarEndFacilityIDCode OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"path identification code"
::= { wfDsx3FarEndConfigEntry 6 }
wfDsx3FarEndCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Far End Current table"
::= { wfDsx3Group 6 }
wfDsx3FarEndCurrentEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 far end current objects
wfDsx3FarEndCurrentIndex corresponds to Wellfleet circuit
number"
INDEX { wfDsx3FarEndCurrentIndex }
::= { wfDsx3FarEndCurrentTable 1 }
WfDsx3FarEndCurrentEntry ::= SEQUENCE {
wfDsx3FarEndCurrentIndex
INTEGER,
wfDsx3FarEndTimeElapsed
INTEGER,
wfDsx3FarEndValidIntervals
INTEGER,
wfDsx3FarEndCurrentCESs
Gauge,
wfDsx3FarEndCurrentCSESs
Gauge,
wfDsx3FarEndCurrentCCVs
Gauge,
wfDsx3FarEndCurrentUASs
Gauge,
wfDsx3FarEndCurrentSASs
Gauge,
wfDsx3FarEndCurrentFCs
Gauge,
wfDsx3FarEndCurrentValidFlag
INTEGER
}
wfDsx3FarEndCurrentIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3FarEndCurrentEntry 1 }
wfDsx3FarEndTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of seconds since the beginning of
the far end current interval"
::= { wfDsx3FarEndCurrentEntry 2 }
wfDsx3FarEndValidIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of previous far end intervals for
which valid data is available"
::= { wfDsx3FarEndCurrentEntry 3 }
wfDsx3FarEndCurrentCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Errored Seconds in
the current far end interval"
::= { wfDsx3FarEndCurrentEntry 4 }
wfDsx3FarEndCurrentCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Severely Errored Seconds
in the current far end interval"
::= { wfDsx3FarEndCurrentEntry 5 }
wfDsx3FarEndCurrentCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Coding Violations
in the current far end interval"
::= { wfDsx3FarEndCurrentEntry 6 }
wfDsx3FarEndCurrentUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds
in the current far end interval"
::= { wfDsx3FarEndCurrentEntry 7 }
wfDsx3FarEndCurrentSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the current far end interval"
::= { wfDsx3FarEndCurrentEntry 8 }
wfDsx3FarEndCurrentFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the current far end interval"
::= { wfDsx3FarEndCurrentEntry 9 }
wfDsx3FarEndCurrentValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3FarEndCurrentEntry 10 }
wfDsx3FarEndIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Far End Interval table"
::= { wfDsx3Group 7 }
wfDsx3FarEndIntervalEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 far end interval objects -
wfDsx3FarEndIntervalIndex corresponds to Wellfleet circuit
number, wfDsx3FarEndIntervalNumber is the numbered previous
15-minute interval"
INDEX { wfDsx3FarEndIntervalIndex,
wfDsx3FarEndIntervalNumber }
::= { wfDsx3FarEndIntervalTable 1 }
WfDsx3FarEndIntervalEntry ::= SEQUENCE {
wfDsx3FarEndIntervalIndex
INTEGER,
wfDsx3FarEndIntervalNumber
INTEGER,
wfDsx3FarEndIntervalCESs
Gauge,
wfDsx3FarEndIntervalCSESs
Gauge,
wfDsx3FarEndIntervalCCVs
Gauge,
wfDsx3FarEndIntervalUASs
Gauge,
wfDsx3FarEndIntervalSASs
Gauge,
wfDsx3FarEndIntervalFCs
Gauge,
wfDsx3FarEndIntervalValidFlag
INTEGER
}
wfDsx3FarEndIntervalIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3FarEndIntervalEntry 1 }
wfDsx3FarEndIntervalNumber OBJECT-TYPE
SYNTAX INTEGER(1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..96 where 1 is the most recent 15-minute interval and 96 is
the least"
::= { wfDsx3FarEndIntervalEntry 2 }
wfDsx3FarEndIntervalCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of C-bit Errored Seconds in the specified interval"
::= { wfDsx3FarEndIntervalEntry 3 }
wfDsx3FarEndIntervalCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of C-bit Severely Errored Seconds in the
specified interval"
::= { wfDsx3FarEndIntervalEntry 4 }
wfDsx3FarEndIntervalCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of C-bit Code Violation error events in the
specified interval"
::= { wfDsx3FarEndIntervalEntry 5 }
wfDsx3FarEndIntervalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of Unavailable Seconds in the specified interval"
::= { wfDsx3FarEndIntervalEntry 6 }
wfDsx3FarEndIntervalSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the specified far end interval"
::= { wfDsx3FarEndIntervalEntry 7 }
wfDsx3FarEndIntervalFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the specified far end interval"
::= { wfDsx3FarEndIntervalEntry 8 }
wfDsx3FarEndIntervalValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3FarEndIntervalEntry 9 }
wfDsx3FarEndTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Far End Total table"
::= { wfDsx3Group 8 }
wfDsx3FarEndTotalEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit far end DS3/E3 total objects - wfDsx3FarEndTotalIndex
corresponds to Wellfleet circuit number"
INDEX { wfDsx3FarEndTotalIndex }
::= { wfDsx3FarEndTotalTable 1 }
WfDsx3FarEndTotalEntry ::= SEQUENCE {
wfDsx3FarEndTotalIndex
INTEGER,
wfDsx3FarEndTotalCESs
Gauge,
wfDsx3FarEndTotalCSESs
Gauge,
wfDsx3FarEndTotalCCVs
Gauge,
wfDsx3FarEndTotalUASs
Gauge,
wfDsx3FarEndTotalSASs
Gauge,
wfDsx3FarEndTotalFCs
Gauge,
wfDsx3FarEndTotalValidFlag
INTEGER
}
wfDsx3FarEndTotalIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3FarEndTotalEntry 1 }
wfDsx3FarEndTotalCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of C-bit Errored Seconds"
::= { wfDsx3FarEndTotalEntry 2 }
wfDsx3FarEndTotalCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of C-bit Severely Errored Seconds"
::= { wfDsx3FarEndTotalEntry 3 }
wfDsx3FarEndTotalCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of C-bit Code Violation error events"
::= { wfDsx3FarEndTotalEntry 4 }
wfDsx3FarEndTotalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of Unavailable Seconds"
::= { wfDsx3FarEndTotalEntry 5 }
wfDsx3FarEndTotalSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
at the far end in the last 24 hours."
::= { wfDsx3FarEndTotalEntry 6 }
wfDsx3FarEndTotalFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
at the far end in the last 24 hours."
::= { wfDsx3FarEndTotalEntry 7 }
wfDsx3FarEndTotalValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3FarEndTotalEntry 8 }
wfAtmInterfaceDs3PlcpTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfAtmInterfaceDs3PlcpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Atm Interface DS3 PLCP table"
::= { wfDsx3Group 9 }
wfAtmInterfaceDs3PlcpEntry OBJECT-TYPE
SYNTAX WfAtmInterfaceDs3PlcpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains ATM interface DS3 PLCP parameters
and state variables, one entry per ATM interface port."
INDEX { wfAtmInterfaceDs3PlcpIndex }
::= { wfAtmInterfaceDs3PlcpTable 1 }
WfAtmInterfaceDs3PlcpEntry ::= SEQUENCE {
wfAtmInterfaceDs3PlcpIndex
INTEGER,
wfAtmInterfaceDs3PlcpSEFSs
Gauge,
wfAtmInterfaceDs3PlcpAlarmState
INTEGER,
wfAtmInterfaceDs3PlcpUASs
Gauge
}
wfAtmInterfaceDs3PlcpIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfAtmInterfaceDs3PlcpEntry 1 }
wfAtmInterfaceDs3PlcpSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of DS3 PLCP Severely Errored Framing Second (SEFS)"
::= { wfAtmInterfaceDs3PlcpEntry 2 }
wfAtmInterfaceDs3PlcpAlarmState OBJECT-TYPE
SYNTAX INTEGER {
noalarm(1),
farendalarm(2),
lof(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the state of the DS3 PLCP"
::= { wfAtmInterfaceDs3PlcpEntry 3 }
wfAtmInterfaceDs3PlcpUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds encountered by the PLCP"
::= { wfAtmInterfaceDs3PlcpEntry 4 }
wfDsx3DayCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3DayCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Current table"
::= { wfDsx3Group 11 }
wfDsx3DayCurrentEntry OBJECT-TYPE
SYNTAX WfDsx3DayCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 current objects - wfDsx3DayCurrentIndex
corresponds to Wellfleet circuit number"
INDEX { wfDsx3DayCurrentIndex }
::= { wfDsx3DayCurrentTable 1 }
WfDsx3DayCurrentEntry ::= SEQUENCE {
wfDsx3DayCurrentIndex
INTEGER,
wfDsx3DayCurrentPESs
Gauge,
wfDsx3DayCurrentPSESs
Gauge,
wfDsx3DayCurrentSEFSs
Gauge,
wfDsx3DayCurrentUASs
Gauge,
wfDsx3DayCurrentLCVs
Gauge,
wfDsx3DayCurrentPCVs
Gauge,
wfDsx3DayCurrentLESs
Gauge,
wfDsx3DayCurrentCCVs
Gauge,
wfDsx3DayCurrentCESs
Gauge,
wfDsx3DayCurrentCSESs
Gauge,
wfDsx3DayCurrentSASs
Gauge,
wfDsx3DayCurrentAISSs
Gauge,
wfDsx3DayCurrentFCs
Gauge,
wfDsx3DayCurrentTimeElapsed
INTEGER,
wfDsx3DayCurrentValidIntervals
INTEGER,
wfDsx3DayCurrentValidFlag
INTEGER
}
wfDsx3DayCurrentIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3DayCurrentEntry 1 }
wfDsx3DayCurrentPESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Errored Seconds in the current interval"
::= { wfDsx3DayCurrentEntry 2 }
wfDsx3DayCurrentPSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Severely Errored Seconds in the
current interval"
::= { wfDsx3DayCurrentEntry 3 }
wfDsx3DayCurrentSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Severely Errored Framing Seconds in the
current interval"
::= { wfDsx3DayCurrentEntry 4 }
wfDsx3DayCurrentUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds in the current interval"
::= { wfDsx3DayCurrentEntry 5 }
wfDsx3DayCurrentLCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Coding Violations in the current interval"
::= { wfDsx3DayCurrentEntry 6 }
wfDsx3DayCurrentPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Coding Violations in the current interval"
::= { wfDsx3DayCurrentEntry 7 }
wfDsx3DayCurrentLESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Errored Seconds in the current interval"
::= { wfDsx3DayCurrentEntry 8 }
wfDsx3DayCurrentCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Coding Violations in the current interval"
::= { wfDsx3DayCurrentEntry 9 }
wfDsx3DayCurrentCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Errored Seconds in the current interval"
::= { wfDsx3DayCurrentEntry 10 }
wfDsx3DayCurrentCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Severely Errored Seconds
in the current interval"
::= { wfDsx3DayCurrentEntry 11 }
wfDsx3DayCurrentSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the current interval"
::= { wfDsx3DayCurrentEntry 12 }
wfDsx3DayCurrentAISSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more AIS defect
in the current interval"
::= { wfDsx3DayCurrentEntry 13 }
wfDsx3DayCurrentFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the current interval"
::= { wfDsx3DayCurrentEntry 14 }
wfDsx3DayCurrentTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of seconds since the beginning of
the far end current interval"
::= { wfDsx3DayCurrentEntry 15 }
wfDsx3DayCurrentValidIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of previous far end intervals for
which valid data is available"
::= { wfDsx3DayCurrentEntry 16 }
wfDsx3DayCurrentValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3DayCurrentEntry 17 }
wfDsx3DayIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3DayIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Interval table"
::= { wfDsx3Group 12 }
wfDsx3DayIntervalEntry OBJECT-TYPE
SYNTAX WfDsx3DayIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 interval objects - wfDsx3DayIntervalIndex
corresponds to Wellfleet circuit number,
wfDsx3DayIntervalNumber is the numbered previous
15-minute interval"
INDEX { wfDsx3DayIntervalIndex,
wfDsx3DayIntervalNumber }
::= { wfDsx3DayIntervalTable 1 }
WfDsx3DayIntervalEntry ::= SEQUENCE {
wfDsx3DayIntervalIndex
INTEGER,
wfDsx3DayIntervalNumber
INTEGER,
wfDsx3DayIntervalPESs
Gauge,
wfDsx3DayIntervalPSESs
Gauge,
wfDsx3DayIntervalSEFSs
Gauge,
wfDsx3DayIntervalUASs
Gauge,
wfDsx3DayIntervalLCVs
Gauge,
wfDsx3DayIntervalPCVs
Gauge,
wfDsx3DayIntervalLESs
Gauge,
wfDsx3DayIntervalCCVs
Gauge,
wfDsx3DayIntervalCESs
Gauge,
wfDsx3DayIntervalCSESs
Gauge,
wfDsx3DayIntervalSASs
Gauge,
wfDsx3DayIntervalAISSs
Gauge,
wfDsx3DayIntervalFCs
Gauge,
wfDsx3DayIntervalValidFlag
INTEGER
}
wfDsx3DayIntervalIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3DayIntervalEntry 1 }
wfDsx3DayIntervalNumber OBJECT-TYPE
SYNTAX INTEGER(1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..96 where 1 is the most recent 15-minute interval and 96 is
the least"
::= { wfDsx3DayIntervalEntry 2 }
wfDsx3DayIntervalPESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Errored Seconds in the specified interval"
::= { wfDsx3DayIntervalEntry 3 }
wfDsx3DayIntervalPSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Severely Errored Seconds in the
specified interval"
::= { wfDsx3DayIntervalEntry 4 }
wfDsx3DayIntervalSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Severely Errored Framing Seconds in the
specified interval"
::= { wfDsx3DayIntervalEntry 5 }
wfDsx3DayIntervalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds in the specified interval"
::= { wfDsx3DayIntervalEntry 6 }
wfDsx3DayIntervalLCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Coding Violations in the specified interval"
::= { wfDsx3DayIntervalEntry 7 }
wfDsx3DayIntervalPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Coding Violations in the specified interval"
::= { wfDsx3DayIntervalEntry 8 }
wfDsx3DayIntervalLESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Errored Seconds in the specified interval"
::= { wfDsx3DayIntervalEntry 9 }
wfDsx3DayIntervalCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Coding Violations in the specified interval"
::= { wfDsx3DayIntervalEntry 10 }
wfDsx3DayIntervalCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Errored Seconds in the specified interval"
::= { wfDsx3DayIntervalEntry 11 }
wfDsx3DayIntervalCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Severely Errored Seconds
in the specified interval"
::= { wfDsx3DayIntervalEntry 12 }
wfDsx3DayIntervalSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the specified interval"
::= { wfDsx3DayIntervalEntry 13 }
wfDsx3DayIntervalAISSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more AIS defect
in the specified interval"
::= { wfDsx3DayIntervalEntry 14 }
wfDsx3DayIntervalFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the specified interval"
::= { wfDsx3DayIntervalEntry 15 }
wfDsx3DayIntervalValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3DayIntervalEntry 16 }
wfDsx3DayTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3DayTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Total table"
::= { wfDsx3Group 13 }
wfDsx3DayTotalEntry OBJECT-TYPE
SYNTAX WfDsx3DayTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 total objects - wfDsx3DayTotalIndex
corresponds to Wellfleet circuit number"
INDEX { wfDsx3DayTotalIndex }
::= { wfDsx3DayTotalTable 1 }
WfDsx3DayTotalEntry ::= SEQUENCE {
wfDsx3DayTotalIndex
INTEGER,
wfDsx3DayTotalPESs
Gauge,
wfDsx3DayTotalPSESs
Gauge,
wfDsx3DayTotalSEFSs
Gauge,
wfDsx3DayTotalUASs
Gauge,
wfDsx3DayTotalLCVs
Gauge,
wfDsx3DayTotalPCVs
Gauge,
wfDsx3DayTotalLESs
Gauge,
wfDsx3DayTotalCCVs
Gauge,
wfDsx3DayTotalCESs
Gauge,
wfDsx3DayTotalCSESs
Gauge,
wfDsx3DayTotalSASs
Gauge,
wfDsx3DayTotalAISSs
Gauge,
wfDsx3DayTotalFCs
Gauge,
wfDsx3DayTotalValidFlag
INTEGER
}
wfDsx3DayTotalIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3DayTotalEntry 1 }
wfDsx3DayTotalPESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Errored Seconds in the last 24 hours"
::= { wfDsx3DayTotalEntry 2 }
wfDsx3DayTotalPSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Severely Errored Seconds in the
last 24 hours"
::= { wfDsx3DayTotalEntry 3 }
wfDsx3DayTotalSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Severely Errored Framing Seconds in the
last 24 hours"
::= { wfDsx3DayTotalEntry 4 }
wfDsx3DayTotalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds in the last 24 hours"
::= { wfDsx3DayTotalEntry 5 }
wfDsx3DayTotalLCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Coding Violations in the last 24 hours"
::= { wfDsx3DayTotalEntry 6 }
wfDsx3DayTotalPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of P-bit Coding Violations in the last 24 hours"
::= { wfDsx3DayTotalEntry 7 }
wfDsx3DayTotalLESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Line Errored Seconds in the last 24 hours"
::= { wfDsx3DayTotalEntry 8 }
wfDsx3DayTotalCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Coding Violations in the last 24 hours"
::= { wfDsx3DayTotalEntry 9 }
wfDsx3DayTotalCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Errored Seconds in the last 24 hours"
::= { wfDsx3DayTotalEntry 10 }
wfDsx3DayTotalCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Severely Errored Seconds
in the last 24 hours"
::= { wfDsx3DayTotalEntry 11 }
wfDsx3DayTotalSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the last 24 hours"
::= { wfDsx3DayTotalEntry 12 }
wfDsx3DayTotalAISSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more AIS defect
in the last 24 hours"
::= { wfDsx3DayTotalEntry 13 }
wfDsx3DayTotalFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the last 24 hours"
::= { wfDsx3DayTotalEntry 14 }
wfDsx3DayTotalValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3DayTotalEntry 15 }
wfDsx3FarEndDayCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndDayCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Far End Current table"
::= { wfDsx3Group 14 }
wfDsx3FarEndDayCurrentEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndDayCurrentEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 far end current objects
wfDsx3FarEndDayCurrentIndex corresponds to Wellfleet circuit
number"
INDEX { wfDsx3FarEndDayCurrentIndex }
::= { wfDsx3FarEndDayCurrentTable 1 }
WfDsx3FarEndDayCurrentEntry ::= SEQUENCE {
wfDsx3FarEndDayCurrentIndex
INTEGER,
wfDsx3FarEndDayTimeElapsed
INTEGER,
wfDsx3FarEndDayValidIntervals
INTEGER,
wfDsx3FarEndDayCurrentCESs
Gauge,
wfDsx3FarEndDayCurrentCSESs
Gauge,
wfDsx3FarEndDayCurrentCCVs
Gauge,
wfDsx3FarEndDayCurrentUASs
Gauge,
wfDsx3FarEndDayCurrentSASs
Gauge,
wfDsx3FarEndDayCurrentFCs
Gauge,
wfDsx3FarEndDayCurrentValidFlag
INTEGER
}
wfDsx3FarEndDayCurrentIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3FarEndDayCurrentEntry 1 }
wfDsx3FarEndDayTimeElapsed OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of seconds since the beginning of
the far end current interval"
::= { wfDsx3FarEndDayCurrentEntry 2 }
wfDsx3FarEndDayValidIntervals OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of previous far end intervals for
which valid data is available"
::= { wfDsx3FarEndDayCurrentEntry 3 }
wfDsx3FarEndDayCurrentCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Errored Seconds in
the current far end interval"
::= { wfDsx3FarEndDayCurrentEntry 4 }
wfDsx3FarEndDayCurrentCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Severely Errored Seconds
in the current far end interval"
::= { wfDsx3FarEndDayCurrentEntry 5 }
wfDsx3FarEndDayCurrentCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of C-bit Coding Violations
in the current far end interval"
::= { wfDsx3FarEndDayCurrentEntry 6 }
wfDsx3FarEndDayCurrentUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Unavailable Seconds
in the current far end interval"
::= { wfDsx3FarEndDayCurrentEntry 7 }
wfDsx3FarEndDayCurrentSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the current far end interval"
::= { wfDsx3FarEndDayCurrentEntry 8 }
wfDsx3FarEndDayCurrentFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the current far end interval"
::= { wfDsx3FarEndDayCurrentEntry 9 }
wfDsx3FarEndDayCurrentValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3FarEndDayCurrentEntry 10 }
wfDsx3FarEndDayIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndDayIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Far End Interval table"
::= { wfDsx3Group 15 }
wfDsx3FarEndDayIntervalEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndDayIntervalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3/E3 far end interval objects -
wfDsx3FarEndDayIntervalIndex corresponds to Wellfleet circuit
number, wfDsx3FarEndDayIntervalNumber is the numbered previous
15-minute interval"
INDEX { wfDsx3FarEndDayIntervalIndex,
wfDsx3FarEndDayIntervalNumber }
::= { wfDsx3FarEndDayIntervalTable 1 }
WfDsx3FarEndDayIntervalEntry ::= SEQUENCE {
wfDsx3FarEndDayIntervalIndex
INTEGER,
wfDsx3FarEndDayIntervalNumber
INTEGER,
wfDsx3FarEndDayIntervalCESs
Gauge,
wfDsx3FarEndDayIntervalCSESs
Gauge,
wfDsx3FarEndDayIntervalCCVs
Gauge,
wfDsx3FarEndDayIntervalUASs
Gauge,
wfDsx3FarEndDayIntervalSASs
Gauge,
wfDsx3FarEndDayIntervalFCs
Gauge,
wfDsx3FarEndDayIntervalValidFlag
INTEGER
}
wfDsx3FarEndDayIntervalIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3FarEndDayIntervalEntry 1 }
wfDsx3FarEndDayIntervalNumber OBJECT-TYPE
SYNTAX INTEGER(1..96)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"1..96 where 1 is the most recent 15-minute interval and 96 is
the least"
::= { wfDsx3FarEndDayIntervalEntry 2 }
wfDsx3FarEndDayIntervalCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of C-bit Errored Seconds in the specified interval"
::= { wfDsx3FarEndDayIntervalEntry 3 }
wfDsx3FarEndDayIntervalCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of C-bit Severely Errored Seconds in the
specified interval"
::= { wfDsx3FarEndDayIntervalEntry 4 }
wfDsx3FarEndDayIntervalCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of C-bit Code Violation error events in the
specified interval"
::= { wfDsx3FarEndDayIntervalEntry 5 }
wfDsx3FarEndDayIntervalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the count of Unavailable Seconds in the specified interval"
::= { wfDsx3FarEndDayIntervalEntry 6 }
wfDsx3FarEndDayIntervalSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
in the specified far end interval"
::= { wfDsx3FarEndDayIntervalEntry 7 }
wfDsx3FarEndDayIntervalFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
in the specified far end interval"
::= { wfDsx3FarEndDayIntervalEntry 8 }
wfDsx3FarEndDayIntervalValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3FarEndDayIntervalEntry 9 }
wfDsx3FarEndDayTotalTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndDayTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The DS3/E3 Far End Total table"
::= { wfDsx3Group 16 }
wfDsx3FarEndDayTotalEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndDayTotalEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit far end DS3/E3 total objects - wfDsx3FarEndDayTotalIndex
corresponds to Wellfleet circuit number"
INDEX { wfDsx3FarEndDayTotalIndex }
::= { wfDsx3FarEndDayTotalTable 1 }
WfDsx3FarEndDayTotalEntry ::= SEQUENCE {
wfDsx3FarEndDayTotalIndex
INTEGER,
wfDsx3FarEndDayTotalCESs
Gauge,
wfDsx3FarEndDayTotalCSESs
Gauge,
wfDsx3FarEndDayTotalCCVs
Gauge,
wfDsx3FarEndDayTotalUASs
Gauge,
wfDsx3FarEndDayTotalSASs
Gauge,
wfDsx3FarEndDayTotalFCs
Gauge,
wfDsx3FarEndDayTotalValidFlag
INTEGER
}
wfDsx3FarEndDayTotalIndex OBJECT-TYPE
SYNTAX INTEGER(1..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfDsx3FarEndDayTotalEntry 1 }
wfDsx3FarEndDayTotalCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of C-bit Errored Seconds"
::= { wfDsx3FarEndDayTotalEntry 2 }
wfDsx3FarEndDayTotalCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of C-bit Severely Errored Seconds"
::= { wfDsx3FarEndDayTotalEntry 3 }
wfDsx3FarEndDayTotalCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of C-bit Code Violation error events"
::= { wfDsx3FarEndDayTotalEntry 4 }
wfDsx3FarEndDayTotalUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total count of Unavailable Seconds"
::= { wfDsx3FarEndDayTotalEntry 5 }
wfDsx3FarEndDayTotalSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Seconds containing one or more SEFs or AIS defects
at the far end in the last 24 hours."
::= { wfDsx3FarEndDayTotalEntry 6 }
wfDsx3FarEndDayTotalFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"the number of Path Failure Count error events detected
at the far end in the last 24 hours."
::= { wfDsx3FarEndDayTotalEntry 7 }
wfDsx3FarEndDayTotalValidFlag OBJECT-TYPE
SYNTAX INTEGER {
valid(1),
invalid(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates whether this interval reported by the Mib Table is valid or
invalid."
DEFVAL { valid }
::= { wfDsx3FarEndDayTotalEntry 8 }
wfDsx3ThrAlrtTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3ThrAlrtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current statistics Alarm Threshold Crossing table."
::= { wfDsx3Group 18 }
wfDsx3ThrAlrtEntry OBJECT-TYPE
SYNTAX WfDsx3ThrAlrtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Dsx3 ThrAlrt table"
INDEX { wfDsx3ThrAlrtIndex }
::= { wfDsx3ThrAlrtTable 1 }
WfDsx3ThrAlrtEntry ::= SEQUENCE {
wfDsx3ThrAlrtDelete
INTEGER,
wfDsx3ThrAlrtIndex
INTEGER,
wfDsx3ThrAlrtPESs
Gauge,
wfDsx3ThrAlrtPSESs
Gauge,
wfDsx3ThrAlrtSEFSs
Gauge,
wfDsx3ThrAlrtUASs
Gauge,
wfDsx3ThrAlrtLCVs
Gauge,
wfDsx3ThrAlrtPCVs
Gauge,
wfDsx3ThrAlrtLESs
Gauge,
wfDsx3ThrAlrtCCVs
Gauge,
wfDsx3ThrAlrtCESs
Gauge,
wfDsx3ThrAlrtCSESs
Gauge,
wfDsx3ThrAlrtSASs
Gauge,
wfDsx3ThrAlrtAISSs
Gauge,
wfDsx3ThrAlrtFCs
Gauge
}
wfDsx3ThrAlrtDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Delete parameter"
DEFVAL { created }
::= { wfDsx3ThrAlrtEntry 1 }
wfDsx3ThrAlrtIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The instance ID that identifies the port."
::= { wfDsx3ThrAlrtEntry 2 }
wfDsx3ThrAlrtPESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of P-bit Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 25 }
::= { wfDsx3ThrAlrtEntry 3 }
wfDsx3ThrAlrtPSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of P-bit Severely Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 4 }
::= { wfDsx3ThrAlrtEntry 4 }
wfDsx3ThrAlrtSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Severely Errored Framing Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3ThrAlrtEntry 5 }
wfDsx3ThrAlrtUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Unavailable Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 10 }
::= { wfDsx3ThrAlrtEntry 6 }
wfDsx3ThrAlrtLCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Line Coding Violations which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 387 }
::= { wfDsx3ThrAlrtEntry 7 }
wfDsx3ThrAlrtPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of P-bit Coding Violations which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 382 }
::= { wfDsx3ThrAlrtEntry 8 }
wfDsx3ThrAlrtLESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Line Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 25 }
::= { wfDsx3ThrAlrtEntry 9 }
wfDsx3ThrAlrtCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Coding Violations which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 382 }
::= { wfDsx3ThrAlrtEntry 10 }
wfDsx3ThrAlrtCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 25 }
::= { wfDsx3ThrAlrtEntry 11 }
wfDsx3ThrAlrtCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Severely Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 4 }
::= { wfDsx3ThrAlrtEntry 12 }
wfDsx3ThrAlrtSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of SEF/AIS Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3ThrAlrtEntry 13 }
wfDsx3ThrAlrtAISSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of AIS defect Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3ThrAlrtEntry 14 }
wfDsx3ThrAlrtFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Path Failure Counts which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3ThrAlrtEntry 15 }
wfDsx3FarEndThrAlrtTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndThrAlrtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current Far End statistics Alarm Threshold Crossing table."
::= { wfDsx3Group 19 }
wfDsx3FarEndThrAlrtEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndThrAlrtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Dsx3 ThrAlrt table"
INDEX { wfDsx3FarEndThrAlrtIndex }
::= { wfDsx3FarEndThrAlrtTable 1 }
WfDsx3FarEndThrAlrtEntry ::= SEQUENCE {
wfDsx3FarEndThrAlrtDelete
INTEGER,
wfDsx3FarEndThrAlrtIndex
INTEGER,
wfDsx3FarEndThrAlrtCESs
Gauge,
wfDsx3FarEndThrAlrtCSESs
Gauge,
wfDsx3FarEndThrAlrtCCVs
Gauge,
wfDsx3FarEndThrAlrtUASs
Gauge,
wfDsx3FarEndThrAlrtSASs
Gauge,
wfDsx3FarEndThrAlrtFCs
Gauge
}
wfDsx3FarEndThrAlrtDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Delete parameter"
DEFVAL { created }
::= { wfDsx3FarEndThrAlrtEntry 1 }
wfDsx3FarEndThrAlrtIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The instance ID that identifies the port."
::= { wfDsx3FarEndThrAlrtEntry 2 }
wfDsx3FarEndThrAlrtCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 25 }
::= { wfDsx3FarEndThrAlrtEntry 3 }
wfDsx3FarEndThrAlrtCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Severely Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 4 }
::= { wfDsx3FarEndThrAlrtEntry 4 }
wfDsx3FarEndThrAlrtCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Coding Violations which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 382 }
::= { wfDsx3FarEndThrAlrtEntry 5 }
wfDsx3FarEndThrAlrtUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Unavailable Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 10 }
::= { wfDsx3FarEndThrAlrtEntry 6 }
wfDsx3FarEndThrAlrtSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of SEF/AIS Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3FarEndThrAlrtEntry 7 }
wfDsx3FarEndThrAlrtFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Path Failure Counts which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3FarEndThrAlrtEntry 8 }
wfDsx3DayThrAlrtTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3DayThrAlrtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current Day statistics Alarm Threshold Crossing table."
::= { wfDsx3Group 20 }
wfDsx3DayThrAlrtEntry OBJECT-TYPE
SYNTAX WfDsx3DayThrAlrtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Dsx3 ThrAlrt table"
INDEX { wfDsx3DayThrAlrtIndex }
::= { wfDsx3DayThrAlrtTable 1 }
WfDsx3DayThrAlrtEntry ::= SEQUENCE {
wfDsx3DayThrAlrtDelete
INTEGER,
wfDsx3DayThrAlrtIndex
INTEGER,
wfDsx3DayThrAlrtPESs
Gauge,
wfDsx3DayThrAlrtPSESs
Gauge,
wfDsx3DayThrAlrtSEFSs
Gauge,
wfDsx3DayThrAlrtUASs
Gauge,
wfDsx3DayThrAlrtLCVs
Gauge,
wfDsx3DayThrAlrtPCVs
Gauge,
wfDsx3DayThrAlrtLESs
Gauge,
wfDsx3DayThrAlrtCCVs
Gauge,
wfDsx3DayThrAlrtCESs
Gauge,
wfDsx3DayThrAlrtCSESs
Gauge,
wfDsx3DayThrAlrtSASs
Gauge,
wfDsx3DayThrAlrtAISSs
Gauge,
wfDsx3DayThrAlrtFCs
Gauge
}
wfDsx3DayThrAlrtDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Delete parameter"
DEFVAL { created }
::= { wfDsx3DayThrAlrtEntry 1 }
wfDsx3DayThrAlrtIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The instance ID that identifies the port."
::= { wfDsx3DayThrAlrtEntry 2 }
wfDsx3DayThrAlrtPESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of P-bit Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 250 }
::= { wfDsx3DayThrAlrtEntry 3 }
wfDsx3DayThrAlrtPSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of P-bit Severely Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 40 }
::= { wfDsx3DayThrAlrtEntry 4 }
wfDsx3DayThrAlrtSEFSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Severely Errored Framing Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3DayThrAlrtEntry 5 }
wfDsx3DayThrAlrtUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Unavailable Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 10 }
::= { wfDsx3DayThrAlrtEntry 6 }
wfDsx3DayThrAlrtLCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Line Coding Violations which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 3865 }
::= { wfDsx3DayThrAlrtEntry 7 }
wfDsx3DayThrAlrtPCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of P-bit Coding Violations which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 3820 }
::= { wfDsx3DayThrAlrtEntry 8 }
wfDsx3DayThrAlrtLESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Line Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 250 }
::= { wfDsx3DayThrAlrtEntry 9 }
wfDsx3DayThrAlrtCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Coding Violations which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 3820 }
::= { wfDsx3DayThrAlrtEntry 10 }
wfDsx3DayThrAlrtCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 250 }
::= { wfDsx3DayThrAlrtEntry 11 }
wfDsx3DayThrAlrtCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Severely Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3DayThrAlrtEntry 12 }
wfDsx3DayThrAlrtSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of SEF/AIS Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 8 }
::= { wfDsx3DayThrAlrtEntry 13 }
wfDsx3DayThrAlrtAISSs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of AIS defect Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3DayThrAlrtEntry 14 }
wfDsx3DayThrAlrtFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Path Failure Counts which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3DayThrAlrtEntry 15 }
wfDsx3FarEndDayThrAlrtTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfDsx3FarEndDayThrAlrtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Current Far End Day statistics Alarm Threshold Crossing table."
::= { wfDsx3Group 21 }
wfDsx3FarEndDayThrAlrtEntry OBJECT-TYPE
SYNTAX WfDsx3FarEndDayThrAlrtEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Dsx3 ThrAlrt table"
INDEX { wfDsx3FarEndDayThrAlrtIndex }
::= { wfDsx3FarEndDayThrAlrtTable 1 }
WfDsx3FarEndDayThrAlrtEntry ::= SEQUENCE {
wfDsx3FarEndDayThrAlrtDelete
INTEGER,
wfDsx3FarEndDayThrAlrtIndex
INTEGER,
wfDsx3FarEndDayThrAlrtCESs
Gauge,
wfDsx3FarEndDayThrAlrtCSESs
Gauge,
wfDsx3FarEndDayThrAlrtCCVs
Gauge,
wfDsx3FarEndDayThrAlrtUASs
Gauge,
wfDsx3FarEndDayThrAlrtSASs
Gauge,
wfDsx3FarEndDayThrAlrtFCs
Gauge
}
wfDsx3FarEndDayThrAlrtDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Delete parameter"
DEFVAL { created }
::= { wfDsx3FarEndDayThrAlrtEntry 1 }
wfDsx3FarEndDayThrAlrtIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The instance ID that identifies the port."
::= { wfDsx3FarEndDayThrAlrtEntry 2 }
wfDsx3FarEndDayThrAlrtCESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 250 }
::= { wfDsx3FarEndDayThrAlrtEntry 3 }
wfDsx3FarEndDayThrAlrtCSESs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Severely Errored Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3FarEndDayThrAlrtEntry 4 }
wfDsx3FarEndDayThrAlrtCCVs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of C-bit Coding Violations which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 3820 }
::= { wfDsx3FarEndDayThrAlrtEntry 5 }
wfDsx3FarEndDayThrAlrtUASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Unavailable Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 10 }
::= { wfDsx3FarEndDayThrAlrtEntry 6 }
wfDsx3FarEndDayThrAlrtSASs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of SEF/AIS Seconds which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 8 }
::= { wfDsx3FarEndDayThrAlrtEntry 7 }
wfDsx3FarEndDayThrAlrtFCs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of Path Failure Counts which must be received
prior to the generation of a Threshold Crossing Alert."
DEFVAL { 0 }
::= { wfDsx3FarEndDayThrAlrtEntry 8 }
END