Wellfleet-FNTS-ATM-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, IpAddress
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
wfFntsAtmGroup
FROM Wellfleet-COMMON-MIB;
wfFntsAtmTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfFntsAtmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Fnts Atm line record"
::= { wfFntsAtmGroup 1 }
wfFntsAtmEntry OBJECT-TYPE
SYNTAX WfFntsAtmEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the FntsAtm table"
INDEX { wfFntsAtmSlot,
wfFntsAtmConnector }
::= { wfFntsAtmTable 1 }
WfFntsAtmEntry ::= SEQUENCE {
wfFntsAtmDelete
INTEGER,
wfFntsAtmDisable
INTEGER,
wfFntsAtmState
INTEGER,
wfFntsAtmSlot
INTEGER,
wfFntsAtmConnector
INTEGER,
wfFntsAtmCct
INTEGER,
wfFntsAtmMtu
INTEGER,
wfFntsAtmMadr
OCTET STRING,
wfFntsAtmIpAdr
IpAddress,
wfFntsAtmAtmState
INTEGER,
wfFntsAtmSpeed
INTEGER,
wfFntsAtmRxOctets
Counter,
wfFntsAtmRxFrames
Counter,
wfFntsAtmTxOctets
Counter,
wfFntsAtmTxFrames
Counter,
wfFntsAtmLackRescErrorRx
Counter,
wfFntsAtmInErrors
Counter,
wfFntsAtmOutErrors
Counter,
wfFntsAtmRxLongFrames
Counter,
wfFntsAtmTxClipFrames
Counter,
wfFntsAtmRxReplenMisses
Counter,
wfFntsAtmRxOverruns
Counter,
wfFntsAtmRxRingErrors
Counter,
wfFntsAtmTxRingErrors
Counter,
wfFntsAtmOpErrors
Counter,
wfFntsAtmRxProcessings
Counter,
wfFntsAtmTxProcessings
Counter,
wfFntsAtmTxCmplProcessings
Counter,
wfFntsAtmIntrProcessings
Counter,
wfFntsAtmSintProcessings
Counter,
wfFntsAtmPintProcessings
Counter,
wfFntsAtmRxRingLength
INTEGER,
wfFntsAtmTxRingLength
INTEGER,
wfFntsAtmCfgRxQueueLength
INTEGER,
wfFntsAtmCfgTxQueueLength
INTEGER,
wfFntsAtmLineNumber
INTEGER
}
wfFntsAtmDelete OBJECT-TYPE
SYNTAX INTEGER {
create(1),
delete(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"create/delete parameter, dflt = created"
DEFVAL { create }
::= { wfFntsAtmEntry 1 }
wfFntsAtmDisable OBJECT-TYPE
SYNTAX INTEGER {
enable(1),
disable(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"enable/disable parameter, dflt = enabled"
DEFVAL { enable }
::= { wfFntsAtmEntry 2 }
wfFntsAtmState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
init(3),
notpresent(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"line driver state variable, Not Present, Init, Down, Up"
DEFVAL { notpresent }
::= { wfFntsAtmEntry 3 }
wfFntsAtmSlot OBJECT-TYPE
SYNTAX INTEGER(1..14)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"instance ID Slot, filled in by driver"
::= { wfFntsAtmEntry 4 }
wfFntsAtmConnector OBJECT-TYPE
SYNTAX INTEGER(1..44)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"instance ID Connector, filled in by driver. For the ASN
this attribute is an encoded value and is equal to
'module'*10 + 'connector'. Where 'module' is defined in
attribute 42 and 'connector' is defined in attribute 43
of this table. For non-ASN platforms this attribute is
the physical connector number on the slot."
::= { wfFntsAtmEntry 5 }
wfFntsAtmCct OBJECT-TYPE
SYNTAX INTEGER(1..1023)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"cct number for this line instance"
::= { wfFntsAtmEntry 6 }
wfFntsAtmMtu OBJECT-TYPE
SYNTAX INTEGER {
default(4508)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"mtu parameter, fixed"
DEFVAL { default }
::= { wfFntsAtmEntry 7 }
wfFntsAtmMadr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"line MAC address, fixed - line driver fills in"
::= { wfFntsAtmEntry 8 }
wfFntsAtmIpAdr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Ip Address, for the Sonet RPU"
::= { wfFntsAtmEntry 9 }
wfFntsAtmAtmState OBJECT-TYPE
SYNTAX INTEGER {
notready(1),
init(2),
intloop(3),
extloop(4),
reset(5),
down(6),
up(7),
notpresent(9)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"line driver state variable, Not Present, Init, Down, Up"
DEFVAL { notpresent }
::= { wfFntsAtmEntry 10 }
wfFntsAtmSpeed OBJECT-TYPE
SYNTAX INTEGER {
default(50)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Atm Interface speed in Meg bps."
DEFVAL { default }
::= { wfFntsAtmEntry 11 }
wfFntsAtmRxOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of bytes received from the Atm interface."
::= { wfFntsAtmEntry 12 }
wfFntsAtmRxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of frames received from the Atm interface."
::= { wfFntsAtmEntry 13 }
wfFntsAtmTxOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of bytes sent to the Atm interface."
::= { wfFntsAtmEntry 14 }
wfFntsAtmTxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of frames sent to the Atm interface."
::= { wfFntsAtmEntry 15 }
wfFntsAtmLackRescErrorRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of requested buffers not available to the
driver."
::= { wfFntsAtmEntry 16 }
wfFntsAtmInErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of errors on the receive side of the driver."
::= { wfFntsAtmEntry 17 }
wfFntsAtmOutErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of errors on the transmit side of the
driver."
::= { wfFntsAtmEntry 18 }
wfFntsAtmRxLongFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of received frames too long."
::= { wfFntsAtmEntry 19 }
wfFntsAtmTxClipFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of transmit frames dropped because of no
transmit queue space."
::= { wfFntsAtmEntry 20 }
wfFntsAtmRxReplenMisses OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of the buffer requests without response."
::= { wfFntsAtmEntry 21 }
wfFntsAtmRxOverruns OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of receiver overruns."
::= { wfFntsAtmEntry 22 }
wfFntsAtmRxRingErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of receiver ring errors."
::= { wfFntsAtmEntry 23 }
wfFntsAtmTxRingErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of transmit ring errors."
::= { wfFntsAtmEntry 24 }
wfFntsAtmOpErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of operational driver errors."
::= { wfFntsAtmEntry 25 }
wfFntsAtmRxProcessings OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of times the receive processing
has been called."
::= { wfFntsAtmEntry 26 }
wfFntsAtmTxProcessings OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of times the transmit processing
has been called."
::= { wfFntsAtmEntry 27 }
wfFntsAtmTxCmplProcessings OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of times the transmit complete processing
has been called."
::= { wfFntsAtmEntry 28 }
wfFntsAtmIntrProcessings OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of times the interrupt service routine
has been called"
::= { wfFntsAtmEntry 29 }
wfFntsAtmSintProcessings OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of times the change state interrupt
has been called."
::= { wfFntsAtmEntry 30
}
wfFntsAtmPintProcessings OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"counts the number of times the primitive interrupt service
routine has been called."
::= { wfFntsAtmEntry 31 }
wfFntsAtmRxRingLength OBJECT-TYPE
SYNTAX INTEGER {
default(63)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Atm Interface Receiver Ring Length."
DEFVAL { default }
::= { wfFntsAtmEntry 32 }
wfFntsAtmTxRingLength OBJECT-TYPE
SYNTAX INTEGER {
default(63)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Atm Interface Transmit Ring Length."
DEFVAL { default }
::= { wfFntsAtmEntry 33 }
wfFntsAtmCfgRxQueueLength OBJECT-TYPE
SYNTAX INTEGER {
default(127)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Atm Configurable receive queue length."
DEFVAL { default }
::= { wfFntsAtmEntry 34 }
wfFntsAtmCfgTxQueueLength OBJECT-TYPE
SYNTAX INTEGER {
default(127)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Atm Configurable transmit queue length."
DEFVAL { default }
::= { wfFntsAtmEntry 35 }
wfFntsAtmLineNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Unique number identifying this interface."
::= { wfFntsAtmEntry 36 }
END