Wellfleet-FR-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Counter, Gauge, TimeTicks, Opaque, enterprises, mgmt
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString, mib-2
FROM RFC1213-MIB
wfFrameRelayGroup
FROM Wellfleet-COMMON-MIB;
wfFrDlcmiTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfFrDlcmiEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Parameters for the Data Link Connection Management Interface"
::= { wfFrameRelayGroup 1 }
wfFrDlcmiEntry OBJECT-TYPE
SYNTAX WfFrDlcmiEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The parameters for a particular Data Link Connection Management Interface"
INDEX { wfFr1DlcmiCircuit }
::= { wfFrDlcmiTable 1 }
WfFrDlcmiEntry ::= SEQUENCE {
wfFr1DlcmiDelete
INTEGER,
wfFr1DlcmiDisable
INTEGER,
wfFr1DlcmiState
INTEGER,
wfFr1DlcmiCircuit
INTEGER,
wfFr1DlcmiManagementType
INTEGER,
wfFr1DlcmiStatus
INTEGER,
wfFr1DlcmiAddress
INTEGER,
wfFr1DlcmiAddressLen
INTEGER,
wfFr1DlcmiPollingInterval
INTEGER,
wfFr1DlcmiFullEnquiryInterval
INTEGER,
wfFr1DlcmiErrorThreshold
INTEGER,
wfFr1DlcmiMonitoredEvents
INTEGER,
wfFr1DlcmiMaxSupportedVCs
INTEGER,
wfFr1DlcmiMulticast
INTEGER,
wfFr1DlcmiSeqCount
INTEGER,
wfFr1DlcmiLastReceived
INTEGER,
wfFr1DlcmiPassiveSeqCount
INTEGER,
wfFr1DlcmiPassiveReceived
INTEGER,
wfFr1DlcmiPolls
INTEGER,
wfFr1DlcmiAlarmTimer
INTEGER,
wfFr1ErrType
INTEGER,
wfFr1ErrData
OCTET STRING,
wfFr1ErrTime
TimeTicks,
wfFr1ErrDiscards
Counter,
wfFr1ErrDrops
Counter
}
wfFr1DlcmiDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indication to delete this frame relay interface"
DEFVAL { created }
::= { wfFrDlcmiEntry 1 }
wfFr1DlcmiDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates when a dlcmi entry is to be enabled or disabled."
DEFVAL { enabled }
::= { wfFrDlcmiEntry 2 }
wfFr1DlcmiState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
init(3),
notpresent(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current state of Frame Relay. The not present state is not actually
valid except when the record is first added. It is included for
consistency."
DEFVAL { notpresent }
::= { wfFrDlcmiEntry 3 }
wfFr1DlcmiCircuit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Instance identifier. The circuit number of this entry"
::= { wfFrDlcmiEntry 4 }
wfFr1DlcmiManagementType OBJECT-TYPE
SYNTAX INTEGER {
none(1),
lmi(2),
t1617d(3),
t1617b(4),
annexa(5),
lmiswitch(6),
annexdswitch(7),
annexaswitch(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable indicates which Data Link Connection Management
scheme is active (and by implication, what DLCI it uses)."
DEFVAL { t1617d }
::= { wfFrDlcmiEntry 5 }
wfFr1DlcmiStatus OBJECT-TYPE
SYNTAX INTEGER {
start(1),
running(2),
fault(3),
recovered(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the status of the interface.
FR1_STATUS_START is the state during rebooting or initial
start of circuit
FR1_STATUS_RUNNING1 is the sate after the circuit is up (either LMI
successful or there is no DLCMI and the system just comes up).
FR1_STATUS_FAULT is a transient state indicating that errors have
caused the circuit to be disabled until DLCMI recovery.
FR1_STATUS_RECOVERED indicates that an the system has been in the
FR_STATUS_FAULT mode before, but has since recovered."
DEFVAL { start }
::= { wfFrDlcmiEntry 6 }
wfFr1DlcmiAddress OBJECT-TYPE
SYNTAX INTEGER {
q921(1),
q922march90(2),
q922november90(3),
q922(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This states which address format is in use on the FR interface.
The default is Q922"
DEFVAL { q922 }
::= { wfFrDlcmiEntry 7 }
wfFr1DlcmiAddressLen OBJECT-TYPE
SYNTAX INTEGER {
twobyte(2),
threebyte(3),
fourbyte(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This variable states the address length in octets. In the case
of Q922 format, the length indicates the entire length of the
address includeding the control portion."
DEFVAL { twobyte }
::= { wfFrDlcmiEntry 8 }
wfFr1DlcmiPollingInterval OBJECT-TYPE
SYNTAX INTEGER(5..30)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of seconds between successive status enquiry messages"
DEFVAL { 10 }
::= { wfFrDlcmiEntry 9 }
wfFr1DlcmiFullEnquiryInterval OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of status enquiry intervals that pass before issuance
of a full status enquiry message."
DEFVAL { 6 }
::= { wfFrDlcmiEntry 10 }
wfFr1DlcmiErrorThreshold OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the maximum number of unanswered Status Enquiries the
equipment shall accept before declaring the interface down."
DEFVAL { 3 }
::= { wfFrDlcmiEntry 11 }
wfFr1DlcmiMonitoredEvents OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the number of status polling intervals over
which the error threshold is counted. For example, if
within 'MonitoredEvents' number of events the station
receives 'ErrorThreshold' number of errors, the
interface is marked as down."
DEFVAL { 4 }
::= { wfFrDlcmiEntry 12 }
wfFr1DlcmiMaxSupportedVCs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of Virtual Circuits allowed for
this interface. Usually dictated by the Frame Relay
network. The system sets this initially."
::= { wfFrDlcmiEntry 13 }
wfFr1DlcmiMulticast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This indicates whether the frame relay provider offers a multicast"
DEFVAL { disabled }
::= { wfFrDlcmiEntry 14 }
wfFr1DlcmiSeqCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This station's sequence counter. It represents the next
value to send."
DEFVAL { 1 }
::= { wfFrDlcmiEntry 15 }
wfFr1DlcmiLastReceived OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sequence number just received from the switch."
DEFVAL { 1 }
::= { wfFrDlcmiEntry 16 }
wfFr1DlcmiPassiveSeqCount OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This station's sequence counter for answering status enquiry."
DEFVAL { 1 }
::= { wfFrDlcmiEntry 17 }
wfFr1DlcmiPassiveReceived OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The sequence number just received from the enquring station."
DEFVAL { 1 }
::= { wfFrDlcmiEntry 18 }
wfFr1DlcmiPolls OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is the counter of where we are in the polling cycle."
::= { wfFrDlcmiEntry 19 }
wfFr1DlcmiAlarmTimer OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This is a counter of 1/2 second timeouts. When it reaches
2 x the polling interval, an enquiry message is sent."
::= { wfFrDlcmiEntry 20 }
wfFr1ErrType OBJECT-TYPE
SYNTAX INTEGER {
unknown(1),
short(2),
long(3),
illegaldlci(4),
unknowndlci(5),
protoerr(6),
unknownie(7),
sequenceerr(8),
unknownrpt(9),
reset(10),
cntrl(11)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicate the type of the last specific monitored error."
::= { wfFrDlcmiEntry 21 }
wfFr1ErrData OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Contains as much of the error packet as possible."
::= { wfFrDlcmiEntry 22 }
wfFr1ErrTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The time the last error occurred."
::= { wfFrDlcmiEntry 23 }
wfFr1ErrDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of inbound frames dropped because of format or other
errors or because the VC was not known."
::= { wfFrDlcmiEntry 24 }
wfFr1ErrDrops OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of outbound frames dropped. Usually this is due the
specified DLCI being unknown or a broadcast packet is too long"
::= { wfFrDlcmiEntry 25 }
wfFrCircuitTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfFrCircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Frame Relay Circuit table gives information about a virtual circuits."
::= { wfFrameRelayGroup 2 }
wfFrCircuitEntry OBJECT-TYPE
SYNTAX WfFrCircuitEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the Frame Relay Circuit table."
INDEX { wfFr1CircuitNumber,
wfFr1CircuitDlci }
::= { wfFrCircuitTable 1 }
WfFrCircuitEntry ::= SEQUENCE {
wfFr1CircuitDelete
INTEGER,
wfFr1CircuitNumber
INTEGER,
wfFr1CircuitDlci
INTEGER,
wfFr1CircuitState
INTEGER,
wfFr1CircuitStateSet
INTEGER,
wfFr1CircuitReceivedFECNs
Counter,
wfFr1CircuitReceivedBECNs
Counter,
wfFr1CircuitSentFrames
Counter,
wfFr1CircuitSentOctets
Counter,
wfFr1CircuitReceivedFrames
Counter,
wfFr1CircuitReceivedOctets
Counter,
wfFr1CircuitCreationTime
TimeTicks,
wfFr1CircuitLastTimeChange
TimeTicks,
wfFr1CircuitCommittedBurst
INTEGER,
wfFr1CircuitExcessBurst
INTEGER,
wfFr1CircuitThroughput
INTEGER,
wfFr1CircuitMulticast
INTEGER,
wfFr1CircuitDiscards
Counter,
wfFr1CircuitDrops
Counter,
wfFr1CircuitSubCct
INTEGER,
wfFr1CircuitMode
INTEGER
}
wfFr1CircuitDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2),
system(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indication to delete this frame relay interface."
DEFVAL { created }
::= { wfFrCircuitEntry 1 }
wfFr1CircuitNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Instance identifier. The circuit number of this interface."
::= { wfFrCircuitEntry 2 }
wfFr1CircuitDlci OBJECT-TYPE
SYNTAX INTEGER {
twobyteminimum(16),
twobytemaximum(1007),
threebyteminimum(1024),
threebytemaximum(64511),
fourbyteminimum(131072),
fourbytemaximum(8257535)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Instance identifier. This indicates which virtual circuit."
::= { wfFrCircuitEntry 3 }
wfFr1CircuitState OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
active(2),
inactive(3),
xoff(4),
control(5)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the state of the particular virtual circuit."
DEFVAL { invalid }
::= { wfFrCircuitEntry 4 }
wfFr1CircuitStateSet OBJECT-TYPE
SYNTAX INTEGER {
invalid(1),
active(2),
inactive(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"User access for setting the state of a virtual circuit"
DEFVAL { invalid }
::= { wfFrCircuitEntry 5 }
wfFr1CircuitReceivedFECNs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames received indicating forward congestion."
::= { wfFrCircuitEntry 6 }
wfFr1CircuitReceivedBECNs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames received indicating backward congestion."
::= { wfFrCircuitEntry 7 }
wfFr1CircuitSentFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames sent from this virtual circuit."
::= { wfFrCircuitEntry 8 }
wfFr1CircuitSentOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets sent from this virtual circuit."
::= { wfFrCircuitEntry 9 }
wfFr1CircuitReceivedFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of frames received from this virtual circuit."
::= { wfFrCircuitEntry 10 }
wfFr1CircuitReceivedOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of octets received from this virtual circuit."
::= { wfFrCircuitEntry 11 }
wfFr1CircuitCreationTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when the vc was created."
::= { wfFrCircuitEntry 12 }
wfFr1CircuitLastTimeChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of sysUpTime when last there was a change in vc state."
::= { wfFrCircuitEntry 13 }
wfFr1CircuitCommittedBurst OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the maximum amount of data, in bits, that the network
agrees to transfer under normal conditions, during the measurement
interval. Wellfleet does not presently support this."
::= { wfFrCircuitEntry 14 }
wfFr1CircuitExcessBurst OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates teh maximum amount of uncommitted data bits that the network
will attempt to deliver over the measurement interval. Wellfleet
does not presently support this."
::= { wfFrCircuitEntry 15 }
wfFr1CircuitThroughput OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the average number of 'Frame Relay Information Field'
bits transferred per second across a user network interface in one
direction, measured over the measurement interval. Wellfleet
does not presently support this."
::= { wfFrCircuitEntry 16 }
wfFr1CircuitMulticast OBJECT-TYPE
SYNTAX INTEGER {
multicast(1),
unicast(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates whether this DLCI is used for multicast or single destination."
DEFVAL { unicast }
::= { wfFrCircuitEntry 17 }
wfFr1CircuitDiscards OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of inbound frames discarded because of format errors,
because the VC is inactive or because the protocol was not registered
for this circuit."
::= { wfFrCircuitEntry 18 }
wfFr1CircuitDrops OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates how many outbound frames were dropped. Usually these are
dropped because the VC is not active."
::= { wfFrCircuitEntry 19 }
wfFr1CircuitSubCct OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Circuit number to use for this VC when configured in hybrid
(for bridging) or direct access (VC as a circuit) mode."
::= { wfFrCircuitEntry 20 }
wfFr1CircuitMode OBJECT-TYPE
SYNTAX INTEGER {
group(1),
hybrid(2),
direct(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The mode of the given VC.
GROUP - treats the VC as one of many vc's on a circuit.
HYBRID - treats the VC as one of many vc's on a circuit for
protocol traffic, but as a separate circuit for bridging.
DIRECT - treats the VC as a separate circuit for all applications."
DEFVAL { group }
::= { wfFrCircuitEntry 21 }
END