Wellfleet-PCAP-MIB DEFINITIONS ::= BEGIN
IMPORTS
Gauge
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
wfPktCaptureGroup
FROM Wellfleet-COMMON-MIB;
wfPktCaptureTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfPktCaptureEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"PCAP line record"
::= { wfPktCaptureGroup 1 }
wfPktCaptureEntry OBJECT-TYPE
SYNTAX WfPktCaptureEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the pcap table"
INDEX { wfPktCaptureLineNumber }
::= { wfPktCaptureTable 1 }
WfPktCaptureEntry ::= SEQUENCE {
wfPktCaptureDelete
INTEGER,
wfPktCaptureDisable
INTEGER,
wfPktCaptureState
INTEGER,
wfPktCaptureFname
DisplayString,
wfPktCaptureControl
INTEGER,
wfPktCaptureCapture
INTEGER,
wfPktCaptureLineNumber
INTEGER,
wfPktCaptureBufSize
INTEGER,
wfPktCapturePktSize
INTEGER,
wfPktCaptureDirection
INTEGER,
wfPktCaptureCount
Gauge,
wfPktCaptureRxTrigger
INTEGER,
wfPktCaptureTxTrigger
INTEGER,
wfPktCaptureRxFltr1Type
INTEGER,
wfPktCaptureRxFltr1Offset
INTEGER,
wfPktCaptureRxFltr1Ref
INTEGER,
wfPktCaptureRxFltr1Size
INTEGER,
wfPktCaptureRxFltr1Match
OCTET STRING,
wfPktCaptureTxFltr1Type
INTEGER,
wfPktCaptureTxFltr1Offset
INTEGER,
wfPktCaptureTxFltr1Ref
INTEGER,
wfPktCaptureTxFltr1Size
INTEGER,
wfPktCaptureTxFltr1Match
OCTET STRING,
wfPktCaptureRxFltr2Type
INTEGER,
wfPktCaptureRxFltr2Offset
INTEGER,
wfPktCaptureRxFltr2Ref
INTEGER,
wfPktCaptureRxFltr2Size
INTEGER,
wfPktCaptureRxFltr2Match
OCTET STRING,
wfPktCaptureRxFltr2Group
INTEGER,
wfPktCaptureTxFltr2Type
INTEGER,
wfPktCaptureTxFltr2Offset
INTEGER,
wfPktCaptureTxFltr2Ref
INTEGER,
wfPktCaptureTxFltr2Size
INTEGER,
wfPktCaptureTxFltr2Match
OCTET STRING,
wfPktCaptureTxFltr2Group
INTEGER,
wfPktCaptureAtmVpi
INTEGER,
wfPktCaptureAtmVci
INTEGER
}
wfPktCaptureDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Delete parameter, created or deleted"
DEFVAL { created }
::= { wfPktCaptureEntry 1 }
wfPktCaptureDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable parameter, enabled or disabled"
DEFVAL { enabled }
::= { wfPktCaptureEntry 2 }
wfPktCaptureState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
init(3),
notpresent(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Interface Gate State"
DEFVAL { notpresent }
::= { wfPktCaptureEntry 3 }
wfPktCaptureFname OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Filename used to retrieve capture buffer"
::= { wfPktCaptureEntry 4 }
wfPktCaptureControl OBJECT-TYPE
SYNTAX INTEGER {
start(1),
stop(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Swapping the value in this field causes the capture
code to do the opposite of what is set in the Capture
field."
DEFVAL { stop }
::= { wfPktCaptureEntry 5 }
wfPktCaptureCapture OBJECT-TYPE
SYNTAX INTEGER {
started(1),
stopped(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Capture state, STARTed or STOPed"
DEFVAL { stopped }
::= { wfPktCaptureEntry 6 }
wfPktCaptureLineNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Instance ID LineNumber, filled in by capture gate"
::= { wfPktCaptureEntry 7 }
wfPktCaptureBufSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Size of capture buffer in 1024 byte increments"
::= { wfPktCaptureEntry 8 }
wfPktCapturePktSize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of bytes to save from packet in 32 byte increments"
::= { wfPktCaptureEntry 9 }
wfPktCaptureDirection OBJECT-TYPE
SYNTAX INTEGER {
rx(1),
tx(2),
both(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Direction of packet flow to capture, Rx, Tx or Both"
DEFVAL { rx }
::= { wfPktCaptureEntry 10 }
wfPktCaptureCount OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packets in capture buffer"
::= { wfPktCaptureEntry 11 }
wfPktCaptureRxTrigger OBJECT-TYPE
SYNTAX INTEGER {
full(1),
match1(2),
match2(3),
notused(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx trigger, Not used, buffer full or match on filter"
DEFVAL { notused }
::= { wfPktCaptureEntry 12 }
wfPktCaptureTxTrigger OBJECT-TYPE
SYNTAX INTEGER {
full(1),
match1(2),
match2(3),
notused(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx trigger, Not used, buffer full or match on filter"
DEFVAL { notused }
::= { wfPktCaptureEntry 13 }
wfPktCaptureRxFltr1Type OBJECT-TYPE
SYNTAX INTEGER {
capture(1),
trigger(2),
notused(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 1 type, Capture, Trigger, or Not used"
DEFVAL { notused }
::= { wfPktCaptureEntry 14 }
wfPktCaptureRxFltr1Offset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 1 offset in bytes"
::= { wfPktCaptureEntry 15 }
wfPktCaptureRxFltr1Ref OBJECT-TYPE
SYNTAX INTEGER {
mac(1),
dl(2),
mcast(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 1 Reference point, MAC, DATA LINK, MULTICAST"
DEFVAL { mac }
::= { wfPktCaptureEntry 16 }
wfPktCaptureRxFltr1Size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 1 field size to match in bytes"
::= { wfPktCaptureEntry 17 }
wfPktCaptureRxFltr1Match OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 1 data to match with packet"
::= { wfPktCaptureEntry 18 }
wfPktCaptureTxFltr1Type OBJECT-TYPE
SYNTAX INTEGER {
capture(1),
trigger(2),
notused(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 1 type, Capture, Trigger or Not used"
DEFVAL { notused }
::= { wfPktCaptureEntry 19 }
wfPktCaptureTxFltr1Offset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 1 offset in bytes"
::= { wfPktCaptureEntry 20 }
wfPktCaptureTxFltr1Ref OBJECT-TYPE
SYNTAX INTEGER {
mac(1),
dl(2),
mcast(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 1 Reference point, MAC, DATA LINK, MULTICAST"
DEFVAL { mac }
::= { wfPktCaptureEntry 21 }
wfPktCaptureTxFltr1Size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 1 field size to match in bytes"
::= { wfPktCaptureEntry 22 }
wfPktCaptureTxFltr1Match OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 1 data to match with packet"
::= { wfPktCaptureEntry 23 }
wfPktCaptureRxFltr2Type OBJECT-TYPE
SYNTAX INTEGER {
capture(1),
trigger(2),
notused(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 2 type, Capture, Trigger or Not used"
DEFVAL { notused }
::= { wfPktCaptureEntry 24 }
wfPktCaptureRxFltr2Offset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 2 offset in bytes"
::= { wfPktCaptureEntry 25 }
wfPktCaptureRxFltr2Ref OBJECT-TYPE
SYNTAX INTEGER {
mac(1),
dl(2),
mcast(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 2 Reference point, MAC, DATA LINK, MULTICAST"
DEFVAL { mac }
::= { wfPktCaptureEntry 26 }
wfPktCaptureRxFltr2Size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 2 field size to match in bytes"
::= { wfPktCaptureEntry 27 }
wfPktCaptureRxFltr2Match OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 2 data to match with packet"
::= { wfPktCaptureEntry 28 }
wfPktCaptureRxFltr2Group OBJECT-TYPE
SYNTAX INTEGER {
or(1),
and(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Rx filter 2 grouping attribute, AND or OR"
DEFVAL { or }
::= { wfPktCaptureEntry 29 }
wfPktCaptureTxFltr2Type OBJECT-TYPE
SYNTAX INTEGER {
capture(1),
trigger(2),
notused(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 2 type, Capture, Trigger or Not used"
DEFVAL { notused }
::= { wfPktCaptureEntry 30 }
wfPktCaptureTxFltr2Offset OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 2 offset in bytes"
::= { wfPktCaptureEntry 31 }
wfPktCaptureTxFltr2Ref OBJECT-TYPE
SYNTAX INTEGER {
mac(1),
dl(2),
mcast(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 2 Reference point, MAC, DATA LINK, MULTICAST"
DEFVAL { mac }
::= { wfPktCaptureEntry 32 }
wfPktCaptureTxFltr2Size OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 2 field size to match in bytes"
::= { wfPktCaptureEntry 33 }
wfPktCaptureTxFltr2Match OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 2 data to match with packet"
::= { wfPktCaptureEntry 34 }
wfPktCaptureTxFltr2Group OBJECT-TYPE
SYNTAX INTEGER {
or(1),
and(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx filter 2 grouping attribute, AND or OR"
DEFVAL { or }
::= { wfPktCaptureEntry 35 }
wfPktCaptureAtmVpi OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM VPI"
::= { wfPktCaptureEntry 36 }
wfPktCaptureAtmVci OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"ATM VCI"
::= { wfPktCaptureEntry 37 }
END