Wellfleet-SIP-MIB DEFINITIONS ::= BEGIN
IMPORTS
IpAddress, Counter, Gauge, TimeTicks, Opaque, enterprises, mgmt
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
TRAP-TYPE
FROM RFC-1215
DisplayString, mib-2
FROM RFC1213-MIB
wfSipGroup
FROM Wellfleet-COMMON-MIB;
wfSipPlcpGroup OBJECT IDENTIFIER ::= { wfSipGroup 2 }
wfSipL2 OBJECT-TYPE
SYNTAX SEQUENCE OF WfSipL2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The SIP L2 Table"
::= { wfSipGroup 1 }
wfSipL2Entry OBJECT-TYPE
SYNTAX WfSipL2Entry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit SIP Level 2 objects - wfSipL2Index
corresponds to Wellfleet circuit number"
INDEX { wfSipL2Index }
::= { wfSipL2 1 }
WfSipL2Entry ::= SEQUENCE {
wfSipL2Index
INTEGER,
wfSipL2ReceivedCounts
Counter,
wfSipL2SentCounts
Counter,
wfSipHcsOrCRCErrors
Counter,
wfSipL2PayloadLengthErrors
Counter,
wfSipL2SequenceNumberErrors
Counter,
wfSipL2MidCurrentlyActiveErrors
Counter,
wfSipL2BomOrSSMsMIDErrors
Counter,
wfSipL2EomsMIDErrors
Counter
}
wfSipL2Index OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfSipL2Entry 1 }
wfSipL2ReceivedCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total of unerrored received SIP L2 PDUs"
::= { wfSipL2Entry 2 }
wfSipL2SentCounts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total of unerrored SIP L2 PDU's sent across the SNI"
::= { wfSipL2Entry 3 }
wfSipHcsOrCRCErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total SIP L2 PDUs with HCS or CRC errors"
::= { wfSipL2Entry 4 }
wfSipL2PayloadLengthErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total SIP L2 PDUs with length errors"
::= { wfSipL2Entry 5 }
wfSipL2SequenceNumberErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"total SIP L2 PDUs with unexpected sequence numbers"
::= { wfSipL2Entry 6 }
wfSipL2MidCurrentlyActiveErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of SIP L2 PDUs with BOMs previously started"
::= { wfSipL2Entry 7 }
wfSipL2BomOrSSMsMIDErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of SIP L2 PDUs with zero BOMs or SSMs not zero"
::= { wfSipL2Entry 8 }
wfSipL2EomsMIDErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of SIP L2 PDUs with zero EOMs or EOMs without BOMs"
::= { wfSipL2Entry 9 }
wfSipDs1Plcp OBJECT-TYPE
SYNTAX SEQUENCE OF WfSipDs1PlcpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The SIP DS1 PLCP Table"
::= { wfSipPlcpGroup 1 }
wfSipDs1PlcpEntry OBJECT-TYPE
SYNTAX WfSipDs1PlcpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS1 PLCP objects - wfSipDs1PlcpIndex
corresponds to Wellfleet circuit number"
INDEX { wfSipDs1PlcpIndex }
::= { wfSipDs1Plcp 1 }
WfSipDs1PlcpEntry ::= SEQUENCE {
wfSipDs1PlcpIndex
INTEGER,
wfSipDs1PlcpSEFs
Counter,
wfSipDs1PlcpAlarmState
INTEGER,
wfSipDs1PlcpUASs
Counter
}
wfSipDs1PlcpIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfSipDs1PlcpEntry 1 }
wfSipDs1PlcpSEFs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of second intervals containing one or more
severely errored seconds"
::= { wfSipDs1PlcpEntry 2 }
wfSipDs1PlcpAlarmState OBJECT-TYPE
SYNTAX INTEGER {
noalarm(1),
receivedfarendalarm(2),
incominglof(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"alarm state"
::= { wfSipDs1PlcpEntry 3 }
wfSipDs1PlcpUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of second intervals containing one or more unavailable
seconds"
::= { wfSipDs1PlcpEntry 4 }
wfSipDs3Plcp OBJECT-TYPE
SYNTAX SEQUENCE OF WfSipDs3PlcpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The SIP DS3 PLCP Table"
::= { wfSipPlcpGroup 2 }
wfSipDs3PlcpEntry OBJECT-TYPE
SYNTAX WfSipDs3PlcpEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"per circuit DS3 PLCP objects - wfSipDs3PlcpIndex
corresponds to Wellfleet circuit number"
INDEX { wfSipDs3PlcpIndex }
::= { wfSipDs3Plcp 1 }
WfSipDs3PlcpEntry ::= SEQUENCE {
wfSipDs3PlcpIndex
INTEGER,
wfSipDs3PlcpSEFs
Counter,
wfSipDs3PlcpAlarmState
INTEGER,
wfSipDs3PlcpUASs
Counter
}
wfSipDs3PlcpIndex OBJECT-TYPE
SYNTAX INTEGER(1..1024)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"this corresponds to the Wellfleet circuit number"
::= { wfSipDs3PlcpEntry 1 }
wfSipDs3PlcpSEFs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of second intervals containing one or more
severely errored seconds"
::= { wfSipDs3PlcpEntry 2 }
wfSipDs3PlcpAlarmState OBJECT-TYPE
SYNTAX INTEGER {
noalarm(1),
receivedfarendalarm(2),
incominglof(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"alarm state"
::= { wfSipDs3PlcpEntry 3 }
wfSipDs3PlcpUASs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of second intervals containing one or more unavailable
seconds"
::= { wfSipDs3PlcpEntry 4 }
END