Wellfleet-STATS-MIB DEFINITIONS ::= BEGIN
IMPORTS
Gauge
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
wfStatsDcGroup
FROM Wellfleet-COMMON-MIB;
wfStatsDc OBJECT IDENTIFIER ::= { wfStatsDcGroup 1 }
wfStatsDcDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable Statistical Data Collection."
DEFVAL { disabled }
::= { wfStatsDc 1 }
wfStatsDcVolume OBJECT-TYPE
SYNTAX INTEGER(0..14)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the file system volume number to which the
Statistical Data Collection info files will be written. The volume
number corresponds to the slot number on which the
volume resides. "
DEFVAL { 4 }
::= { wfStatsDc 2 }
wfStatsDcFilePrefix OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of statistical data files."
::= { wfStatsDc 3 }
wfStatsDcUpdateInterval OBJECT-TYPE
SYNTAX INTEGER(10..2147483647)
ACCESS read-write
STATUS obsolete
DESCRIPTION
"This number specifies the interval (number of minutes)
for the STATS process to collect and update STATS data."
DEFVAL { 60 }
::= { wfStatsDc 4 }
wfStatsDcStoreInterval OBJECT-TYPE
SYNTAX INTEGER(10..2147483647)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This number specifies the interval (number of minutes)
for the STATS master process to collect and update STATS
data from each slot and to write statistical data on to the
file system. "
DEFVAL { 60 }
::= { wfStatsDc 5 }
wfStatsDcUpdateData OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS obsolete
DESCRIPTION
"Setting this attribute to a non-zero value will cause
an immediate updating of the statistical data.
Once activated, this attribute should be reset to zero
to allow subsequent activations. "
::= { wfStatsDc 6 }
wfStatsDcStoreData OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this attribute to a non-zero value will cause
an immediate writing of the statistical data info to
a file in SRAM. Once activated, this attribute should
be reset to zero to allow subsequent activations. "
::= { wfStatsDc 7 }
wfStatsDcSwitchId OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-write
STATUS mandatory
DESCRIPTION
"switch id used in the statistical data file to identify BNX. If
it is not given explicitely, it will be assigned with wfSysName."
::= { wfStatsDc 8 }
wfStatsDcEnableAll OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute, if set, will overwrite individual logical line
enable/disable setting of statistical data collection."
DEFVAL { off }
::= { wfStatsDc 9 }
wfStatsDcMaxNumFiles OBJECT-TYPE
SYNTAX INTEGER(0..144)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute sets the MAX number of STATS files in an SRAM.
If this number is reached, before writing the next STATS DC
file to SRAM, the older STATS DC file will be delete.
Note: Value 0 has the special meaning that this limitation
will not take into effect. The DC file will be written
in the round robin manner."
::= { wfStatsDc 10 }
wfStatsDcFrVcDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this switch is turned on, the stats data of all VCs of the
configured circuit will be collected. This is per BNX."
DEFVAL { disabled }
::= { wfStatsDc 11 }
wfStatsDcState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
init(3),
notpresent(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"current state."
DEFVAL { notpresent }
::= { wfStatsDc 12 }
wfStatsDcHssiFields OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"************************************************************"
DEFVAL { 4278190080 }
::= { wfStatsDc 13 }
wfStatsDcSyncFields OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"************************************************************"
DEFVAL { 4278190080 }
::= { wfStatsDc 14 }
wfStatsDcDs1E1Fields OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"************************************************************"
DEFVAL { 4294836224 }
::= { wfStatsDc 15 }
wfStatsDcFrSwVcFields OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"************************************************************"
DEFVAL { 4294966272 }
::= { wfStatsDc 16 }
wfStatsDcCctCngcFields OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"************************************************************"
DEFVAL { 4294901760 }
::= { wfStatsDc 17 }
wfStatsDcFddiFields OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"************************************************************"
::= { wfStatsDc 18 }
wfStatsDcCctCngcDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute is to enable.disable frsw cngc data collection"
DEFVAL { disabled }
::= { wfStatsDc 19 }
wfStatsDcLbcFileDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"To enable/disable LBC file write."
DEFVAL { disabled }
::= { wfStatsDc 20 }
wfStatsDcAtmzPhyFields OBJECT-TYPE
SYNTAX Gauge
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Selection of Atmz Line Attributes for Data Collection "
DEFVAL { 4294967264 }
::= { wfStatsDc 21 }
wfStatsDcMediaTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfStatsDcMediaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"STATS Generic Media table for Generic media drivers using Line Number in their mib."
::= { wfStatsDcGroup 2 }
wfStatsDcMediaEntry OBJECT-TYPE
SYNTAX WfStatsDcMediaEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The parameters for Stats."
INDEX { wfStatsDcMediaLineNumber }
::= { wfStatsDcMediaTable 1 }
WfStatsDcMediaEntry ::= SEQUENCE {
wfStatsDcMediaDelete
INTEGER,
wfStatsDcMediaLineNumber
INTEGER
}
wfStatsDcMediaDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates status of this entry."
DEFVAL { created }
::= { wfStatsDcMediaEntry 1 }
wfStatsDcMediaLineNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Instance identifier; this indicates which line number
NOTE: Line number is based on the following scheme:
msb 0 00 00 00 0 00 lsb
resv. chan type slot mod conn"
::= { wfStatsDcMediaEntry 2 }
wfStatsDcLbcTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfStatsDcLbcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LBC Entry using line number as its index."
::= { wfStatsDcGroup 3 }
wfStatsDcLbcEntry OBJECT-TYPE
SYNTAX WfStatsDcLbcEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"LBC Entry using line number as its index."
INDEX { wfStatsDcLbcLineNumber }
::= { wfStatsDcLbcTable 1 }
WfStatsDcLbcEntry ::= SEQUENCE {
wfStatsDcLbcDelete
INTEGER,
wfStatsDcLbcDisable
INTEGER,
wfStatsDcLbcLineNumber
INTEGER,
wfStatsDcLbcUpdateInterval
INTEGER,
wfStatsDcLbcState
INTEGER,
wfStatsDcLbcRxMaxDelta0
Gauge,
wfStatsDcLbcTxMaxDelta0
Gauge,
wfStatsDcLbcRxMaxDelta1
Gauge,
wfStatsDcLbcTxMaxDelta1
Gauge,
wfStatsDcLbcRxMaxDelta2
Gauge,
wfStatsDcLbcTxMaxDelta2
Gauge,
wfStatsDcLbcRxMaxDelta3
Gauge,
wfStatsDcLbcTxMaxDelta3
Gauge,
wfStatsDcLbcRxMaxDelta4
Gauge,
wfStatsDcLbcTxMaxDelta4
Gauge,
wfStatsDcLbcRxMaxDelta5
Gauge,
wfStatsDcLbcTxMaxDelta5
Gauge,
wfStatsDcLbcRxMaxDelta6
Gauge,
wfStatsDcLbcTxMaxDelta6
Gauge,
wfStatsDcLbcRxMaxDelta7
Gauge,
wfStatsDcLbcTxMaxDelta7
Gauge,
wfStatsDcLbcRxMaxDelta8
Gauge,
wfStatsDcLbcTxMaxDelta8
Gauge,
wfStatsDcLbcRxMaxDelta9
Gauge,
wfStatsDcLbcTxMaxDelta9
Gauge,
wfStatsDcLbcRxMaxDelta10
Gauge,
wfStatsDcLbcTxMaxDelta10
Gauge,
wfStatsDcLbcRxMaxDelta11
Gauge,
wfStatsDcLbcTxMaxDelta11
Gauge,
wfStatsDcLbcRxMaxDelta12
Gauge,
wfStatsDcLbcTxMaxDelta12
Gauge,
wfStatsDcLbcRxMaxDelta13
Gauge,
wfStatsDcLbcTxMaxDelta13
Gauge,
wfStatsDcLbcRxMaxDelta14
Gauge,
wfStatsDcLbcTxMaxDelta14
Gauge,
wfStatsDcLbcRxMaxDelta15
Gauge,
wfStatsDcLbcTxMaxDelta15
Gauge,
wfStatsDcLbcRxMaxDelta16
Gauge,
wfStatsDcLbcTxMaxDelta16
Gauge,
wfStatsDcLbcRxMaxDelta17
Gauge,
wfStatsDcLbcTxMaxDelta17
Gauge,
wfStatsDcLbcRxMaxDelta18
Gauge,
wfStatsDcLbcTxMaxDelta18
Gauge,
wfStatsDcLbcRxMaxDelta19
Gauge,
wfStatsDcLbcTxMaxDelta19
Gauge,
wfStatsDcLbcRxMaxDelta20
Gauge,
wfStatsDcLbcTxMaxDelta20
Gauge,
wfStatsDcLbcRxMaxDelta21
Gauge,
wfStatsDcLbcTxMaxDelta21
Gauge,
wfStatsDcLbcRxMaxDelta22
Gauge,
wfStatsDcLbcTxMaxDelta22
Gauge,
wfStatsDcLbcRxMaxDelta23
Gauge,
wfStatsDcLbcTxMaxDelta23
Gauge
}
wfStatsDcLbcDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "To create or delete this instance."
DEFVAL { created }
::= { wfStatsDcLbcEntry 1 }
wfStatsDcLbcDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION "When this switch is turned on, BNX will read
the configured trunk line's rx/tx counter value at
a predetermined time frequency."
DEFVAL { enabled }
::= { wfStatsDcLbcEntry 2 }
wfStatsDcLbcLineNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"line number for this line instance"
::= { wfStatsDcLbcEntry 3 }
wfStatsDcLbcUpdateInterval OBJECT-TYPE
SYNTAX INTEGER (1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION "The value must be divisible into 60. In another
word, 60/value must be an integer."
DEFVAL { 5 }
::= { wfStatsDcLbcEntry 4 }
wfStatsDcLbcState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
init(3),
notpresent(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION "TBC state "
DEFVAL { notpresent }
::= { wfStatsDcLbcEntry 5}
wfStatsDcLbcRxMaxDelta0 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 0."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 6 }
wfStatsDcLbcTxMaxDelta0 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 0."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 7 }
wfStatsDcLbcRxMaxDelta1 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 1."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 8 }
wfStatsDcLbcTxMaxDelta1 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 1."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 9 }
wfStatsDcLbcRxMaxDelta2 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 2."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 10 }
wfStatsDcLbcTxMaxDelta2 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 2."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 11 }
wfStatsDcLbcRxMaxDelta3 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 3."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 12 }
wfStatsDcLbcTxMaxDelta3 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 3."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 13 }
wfStatsDcLbcRxMaxDelta4 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 4."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 14 }
wfStatsDcLbcTxMaxDelta4 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 4."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 15 }
wfStatsDcLbcRxMaxDelta5 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 5."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 16 }
wfStatsDcLbcTxMaxDelta5 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 5."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 17 }
wfStatsDcLbcRxMaxDelta6 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 6."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 18 }
wfStatsDcLbcTxMaxDelta6 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 6."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 19 }
wfStatsDcLbcRxMaxDelta7 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 7."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 20 }
wfStatsDcLbcTxMaxDelta7 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 7."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 21 }
wfStatsDcLbcRxMaxDelta8 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 8."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 22 }
wfStatsDcLbcTxMaxDelta8 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 8."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 23 }
wfStatsDcLbcRxMaxDelta9 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 9."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 24 }
wfStatsDcLbcTxMaxDelta9 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 9."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 25 }
wfStatsDcLbcRxMaxDelta10 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 10."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 26 }
wfStatsDcLbcTxMaxDelta10 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 10."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 27 }
wfStatsDcLbcRxMaxDelta11 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 11."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 28 }
wfStatsDcLbcTxMaxDelta11 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 11."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 29 }
wfStatsDcLbcRxMaxDelta12 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 12."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 30 }
wfStatsDcLbcTxMaxDelta12 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 12."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 31 }
wfStatsDcLbcRxMaxDelta13 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 13."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 32 }
wfStatsDcLbcTxMaxDelta13 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 13."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 33 }
wfStatsDcLbcRxMaxDelta14 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 14."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 34 }
wfStatsDcLbcTxMaxDelta14 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 14."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 35 }
wfStatsDcLbcRxMaxDelta15 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 15."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 36 }
wfStatsDcLbcTxMaxDelta15 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 15."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 37 }
wfStatsDcLbcRxMaxDelta16 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 16."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 38 }
wfStatsDcLbcTxMaxDelta16 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 16."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 39 }
wfStatsDcLbcRxMaxDelta17 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 17."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 40 }
wfStatsDcLbcTxMaxDelta17 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 17."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 41 }
wfStatsDcLbcRxMaxDelta18 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 18."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 42 }
wfStatsDcLbcTxMaxDelta18 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 18."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 43 }
wfStatsDcLbcRxMaxDelta19 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 19."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 44 }
wfStatsDcLbcTxMaxDelta19 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 19."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 45 }
wfStatsDcLbcRxMaxDelta20 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 20."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 46 }
wfStatsDcLbcTxMaxDelta20 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 20."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 47 }
wfStatsDcLbcRxMaxDelta21 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 21."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 48 }
wfStatsDcLbcTxMaxDelta21 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 21."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 49 }
wfStatsDcLbcRxMaxDelta22 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 22."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 50 }
wfStatsDcLbcTxMaxDelta22 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 22."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 51 }
wfStatsDcLbcRxMaxDelta23 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the rx bytes count for this instance
in hour 23."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 52 }
wfStatsDcLbcTxMaxDelta23 OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION "Maximum number of the tx bytes count for this instance
in hour 23."
DEFVAL { 0 }
::= { wfStatsDcLbcEntry 53 }
END