Wellfleet-SYNC-MIB DEFINITIONS ::= BEGIN
IMPORTS
Counter, Gauge, TimeTicks
FROM RFC1155-SMI
OBJECT-TYPE
FROM RFC-1212
DisplayString
FROM RFC1213-MIB
wfLine
FROM Wellfleet-COMMON-MIB;
wfSyncTable OBJECT-TYPE
SYNTAX SEQUENCE OF WfSyncEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"SYNC line record"
::= { wfLine 5 }
wfSyncEntry OBJECT-TYPE
SYNTAX WfSyncEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"An entry in the SYNC table"
INDEX { wfSyncSlot,
wfSyncConnector }
::= { wfSyncTable 1 }
WfSyncEntry ::= SEQUENCE {
wfSyncDelete
INTEGER,
wfSyncDisable
INTEGER,
wfSyncState
INTEGER,
wfSyncSlot
INTEGER,
wfSyncConnector
INTEGER,
wfSyncCct
INTEGER,
wfSyncBofl
INTEGER,
wfSyncBoflTmo
INTEGER,
wfSyncMtu
INTEGER,
wfSyncMadr
OCTET STRING,
wfSyncPromiscuous
INTEGER,
wfSyncXid
INTEGER,
wfSyncClkSource
INTEGER,
wfSyncClkSpeed
INTEGER,
wfSyncSignalMode
INTEGER,
wfSyncRtsEnable
INTEGER,
wfSyncBurstCount
INTEGER,
wfSyncService
INTEGER,
wfSyncRetryCount
INTEGER,
wfSyncLinkIdleTimer
INTEGER,
wfSyncRetryTimer
INTEGER,
wfSyncExtendedAddress
INTEGER,
wfSyncExtendedAddressForce
INTEGER,
wfSyncExtendedControl
INTEGER,
wfSyncExtendedControlForce
INTEGER,
wfSyncConnectAttempts
INTEGER,
wfSyncWindowSizeTx
INTEGER,
wfSyncWindowSizeTxExtc
INTEGER,
wfSyncMinFrameSpace
INTEGER,
wfSyncLocalAddress
INTEGER,
wfSyncRemoteAddress
INTEGER,
wfSyncPassThruLocalMadr
OCTET STRING,
wfSyncPassThruRemoteMadr
OCTET STRING,
wfSyncWanProtocol
INTEGER,
wfSyncCrcSize
INTEGER,
wfSyncRxOctets
Counter,
wfSyncRxFrames
Counter,
wfSyncTxOctets
Counter,
wfSyncTxFrames
Counter,
wfSyncRxErrors
Counter,
wfSyncTxErrors
Counter,
wfSyncLackRescRx
Counter,
wfSyncLackRescTx
Counter,
wfSyncUnderFlowTx
Counter,
wfSyncRejectsTx
Counter,
wfSyncRejectsRx
Counter,
wfSyncOverFlowRx
Counter,
wfSyncFramesIncompRx
Counter,
wfSyncBadFramesRx
Counter,
wfSyncFrameRejectsRx
Counter,
wfSyncRuntsRx
Counter,
wfSyncT1Timeouts
Counter,
wfSyncMemoryErrors
Counter,
wfSyncMediaType
INTEGER,
wfSyncCfgTxQueueLength
INTEGER,
wfSyncCfgRxQueueLength
INTEGER,
wfSyncTxQueueLength
INTEGER,
wfSyncRxQueueLength
INTEGER,
wfSyncRxReplenMisses
Counter,
wfSyncStartUpMode
INTEGER,
wfSyncIdleRRFrames
INTEGER,
wfSyncMultilineMode
INTEGER,
wfSyncBODExamPeriod
INTEGER,
wfSyncBODFullThreshold
INTEGER,
wfSyncBODRecoverThreshold
INTEGER,
wfSyncBODPeriodsToFail
INTEGER,
wfSyncKG84ACycle
INTEGER,
wfSyncKG84ASyncLossInterval
INTEGER,
wfSyncKG84ARemoteResyncWait
INTEGER,
wfSyncKG84ASyncPulse
INTEGER,
wfSyncKG84AResyncs
INTEGER,
wfSyncKG84AResyncsDetected
INTEGER,
wfSyncKG84ABsu
INTEGER,
wfSyncKG84AState
INTEGER,
wfSyncKG84AOkFrames
INTEGER,
wfSyncPollingEnable
INTEGER,
wfSyncBackupPool
INTEGER,
wfSyncDemandPool
INTEGER,
wfSyncLineNumber
INTEGER,
wfSyncHoldDownTime
INTEGER,
wfSyncNetworkType
INTEGER,
wfSyncActiveCct
INTEGER,
wfSyncCableType
INTEGER,
wfSyncRxDropPackets
Counter,
wfSyncTxDropPackets
Counter,
wfSyncModule
INTEGER,
wfSyncActualConnector
INTEGER,
wfSyncLineCoding
INTEGER,
wfSyncLastChange
TimeTicks,
wfSyncOutQLen
Gauge,
wfSyncRemoteLpbkDetection
INTEGER,
wfSyncLastState
INTEGER,
wfSyncExternalClkSpeed
INTEGER,
wfSyncBChannelOverride
INTEGER,
wfSyncBChannel
INTEGER,
wfSyncForceIFTF
INTEGER,
wfSyncPriority
INTEGER,
wfSyncTurboBofl
INTEGER,
wfSyncBoflNum
INTEGER,
wfSyncBoflLen
INTEGER,
wfSyncTurboBoflMisses
INTEGER,
wfSyncTurboBoflInvocations
INTEGER,
wfSyncBandwidthOnDemandPool
INTEGER,
wfSyncBODRecoverPeriodsToPass
INTEGER,
wfSyncBODHistory
DisplayString,
wfSyncBODDebugFlag
INTEGER,
wfSyncBChRateAdaption
INTEGER,
wfSyncBChActualRateAdaption
INTEGER,
wfSyncWanType
INTEGER,
wfSyncAsyncBaudRate
INTEGER,
wfSyncCfgAsyncCmndMaxIdles
INTEGER,
wfSyncAsyncCmndMaxIdles
INTEGER,
wfSyncCfgAsyncDataMaxIdles
INTEGER,
wfSyncAsyncDataMaxIdles
INTEGER,
wfSyncFramesAbortTx
Counter,
wfSyncPasyncParityType
INTEGER,
wfSyncPasyncCharacterLength
INTEGER,
wfSyncPasyncStopLength
INTEGER,
wfSyncPasyncBaudRate
INTEGER,
wfSyncLocalConnectionState
INTEGER,
wfSyncRemoteConnectionState
INTEGER,
wfSyncTimeSlotAssignment
DisplayString,
wfSyncEiaStatus
INTEGER,
wfSyncEiaStatusReset
INTEGER,
wfSyncUcastMap
INTEGER
}
wfSyncDelete OBJECT-TYPE
SYNTAX INTEGER {
created(1),
deleted(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Create/Delete parameter"
DEFVAL { created }
::= { wfSyncEntry 1 }
wfSyncDisable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable/Disable parameter"
DEFVAL { enabled }
::= { wfSyncEntry 2 }
wfSyncState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
init(3),
wait(4),
notpresent(5),
dsrwait(6),
holddown(7),
remoteloop(8),
lineloopbofltest(19),
notpres(20)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line Driver state variable, Reflects the current state of the
Line Driver. NOTPRESENT is an obsoleted state. It is replaced
with NOTPRES."
DEFVAL { notpres }
::= { wfSyncEntry 3 }
wfSyncSlot OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Instance ID Slot, filled in by driver"
::= { wfSyncEntry 4 }
wfSyncConnector OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Instance ID Connector, filled in by driver. For the ASN
this attribute is an encoded value and is equal to
'module'*10 + 'connector'. Where 'module' is defined in
attribute 86 and 'connector' is defined in attribute 78
of this table. For non-ASN platforms this attribute is
the physical connector number on the slot."
::= { wfSyncEntry 5 }
wfSyncCct OBJECT-TYPE
SYNTAX INTEGER(1..1023)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CCT number for this line instance"
::= { wfSyncEntry 6 }
wfSyncBofl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"breath of life parameter"
DEFVAL { enabled }
::= { wfSyncEntry 7 }
wfSyncBoflTmo OBJECT-TYPE
SYNTAX INTEGER(1..60)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"breath of life timeout in seconds"
DEFVAL { 5 }
::= { wfSyncEntry 8 }
wfSyncMtu OBJECT-TYPE
SYNTAX INTEGER(3..4608)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"MTU parameter, this is buffer size for SYNC media, fixed"
DEFVAL { 1600 }
::= { wfSyncEntry 9 }
wfSyncMadr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Line MAC address, fixed - line driver fills in from the 48 bit
address stored in the serial number prom for this connector."
::= { wfSyncEntry 10 }
wfSyncPromiscuous OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The promiscuous parameter allows address filtering based on the local
and remote addresses. When enabled, all frames are received, disabled
indicates only frames destined for this local address are received"
DEFVAL { disabled }
::= { wfSyncEntry 11 }
wfSyncXid OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"XID enable/disable parameter. This parameter is used to enable
or disable transmission/reception of Test XID frames."
DEFVAL { disabled }
::= { wfSyncEntry 12 }
wfSyncClkSource OBJECT-TYPE
SYNTAX INTEGER {
internal(1),
external(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Tx/Rx clock source is either internally or external generated."
DEFVAL { external }
::= { wfSyncEntry 13 }
wfSyncClkSpeed OBJECT-TYPE
SYNTAX INTEGER {
clk1200b(1200),
clk2400b(2401),
clk4800b(4807),
clk7200b(7204),
clk9600b(9615),
clk19200b(19230),
clk32000b(32051),
clk38400b(38461),
clk56k(56818),
clk64k(64102),
clk125k(125000),
clk230k(227272),
clk420k(416666),
clk625k(625000),
clk833k(833333),
clk1mb(1250000),
clk2mb(2500000),
clk5mb(5000000)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Internal Tx/Rx clock speed. This speed selection is valid only when
internal clocking is selected."
DEFVAL { clk64k }
::= { wfSyncEntry 14 }
wfSyncSignalMode OBJECT-TYPE
SYNTAX INTEGER {
balanced(1),
unbalanced(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The signal mode parameter indicates the line paramter balanced or
unbalanced."
DEFVAL { balanced }
::= { wfSyncEntry 15 }
wfSyncRtsEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
kg84aenabled(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Note: In KG84 support, RTS has a different meaning"
DEFVAL { disabled }
::= { wfSyncEntry 16 }
wfSyncBurstCount OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2),
unlimited(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Allows control over the DMA burst cycle duration on MK5025 based products.
This attribute is ignored for AN and ASN products. The default is always
8 short word bursts (ENABLED). There are only two cases in which this
attribute should be changed.
Case 1: In certain cases with DSDE and DSE link modules when one or both
of the ethernet ports are suffering from excessive TxUflo or RxOflo
errors, the BurstCount of one or both SYNC interfaces can be set to
single short word bursts (DISABLED). The only modules for which this
may be necessary are the DSDE (5430 - Dual Sync, Dual Enet) (module ID
112) and the DSE (5420 - Dual Sync, Single Enet) (module ID 116).
If after making the change, the TxUflo or RxOflo errors persist on the
ethernet or this SYNC interface starts to get UnderFlowTx or OverFlowRx
errors, then the Link Module is overloaded and a more significant
software configuration change or a hardware configuration change is
needed.
Case 2: When a SYNC interface on an mk5025 based Link Module is getting
UnderFlowTx or OverFlowRx errors while running at bandwidths greater
than 2Mbps, the errors may be eliminated by setting this attribute to
unlimited burst mode (UNLIMITED). If after making the change, the
errors persist or the same errors start on another SYNC interface or
one of the ethernet interfaces on the same module starts to get TxUflo
or RxOflo errors, then the Link Module is overloaded and a more
significant software configuration change or a hardware configuration
change is needed. For 6Mbps full duplex operation, this attribute
will most likely need to be set to UNLIMITED and all other interfaces
on this module will most likely have to be deconfigured."
DEFVAL { enabled }
::= { wfSyncEntry 17 }
wfSyncService OBJECT-TYPE
SYNTAX INTEGER {
transparent(1),
llc1(2),
llc2(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Service type for this circuit. Transparent is raw HDLC mode, LLC1 will
prefix the HDLC address and control fields to the frame. The LLC2 service
provides the LAPB protocol service."
DEFVAL { llc1 }
::= { wfSyncEntry 18 }
wfSyncRetryCount OBJECT-TYPE
SYNTAX INTEGER(1..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Retry count parameter indicates the number of retransmission
attempts which will be tried per frame before a line is determined
to be down. The retry count is max attempts following expiration of
the T1 timer. This parameter is equal to the N2 counter in ICB."
DEFVAL { 16 }
::= { wfSyncEntry 19 }
wfSyncLinkIdleTimer OBJECT-TYPE
SYNTAX INTEGER(1..9999)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The link idle parameter is the number of seconds before a line has
been determined to be idle. An idle line is considered disconnectd
This value is expressed in seconds."
DEFVAL { 9 }
::= { wfSyncEntry 20 }
wfSyncRetryTimer OBJECT-TYPE
SYNTAX INTEGER(1..9999)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Retry Timer parameter indicates the timeout in tenths of seconds for a
response to be heard form the link. Link control frames are sent at
the expiration of this timer value. The frames will be resent up to
retry count (N2) at which time the link will be disconnected."
DEFVAL { 30 }
::= { wfSyncEntry 21 }
wfSyncExtendedAddress OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls length determination of the address field.
When this parameter is enabled, the first bit of the address field
be tested to determine the length of address field in octets."
DEFVAL { disabled }
::= { wfSyncEntry 22 }
wfSyncExtendedAddressForce OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this parameter is enabled, the receiver will assume that all
address fields are 2 octets in length regardless of the first two
bits of the control field. Usefull only in Transparent Mode."
DEFVAL { disabled }
::= { wfSyncEntry 23 }
wfSyncExtendedControl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter allows the control fields of all S and I frames to
become 2 octets in length instead of one. Numbering of all I frame
become modulo 128 instead of modulo 8. The control field of U
frames remains one octet in length."
DEFVAL { disabled }
::= { wfSyncEntry 24 }
wfSyncExtendedControlForce OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter when enabled will force all control fields to become
two octets in length regardless the first two bits in the control
field. Usefull only in Transparent Mode. (LLC1)"
DEFVAL { disabled }
::= { wfSyncEntry 25 }
wfSyncConnectAttempts OBJECT-TYPE
SYNTAX INTEGER(1..9999)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls the number of connection attempts which
will be made during a LAPB connection request. This parameter
is applicable only during LLC2 service."
DEFVAL { 10 }
::= { wfSyncEntry 26 }
wfSyncWindowSizeTx OBJECT-TYPE
SYNTAX INTEGER(1..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The window size parameter controls the number of I frames which
may be transmitted without acknowledgement. Non EXTC mode."
DEFVAL { 1 }
::= { wfSyncEntry 27 }
wfSyncWindowSizeTxExtc OBJECT-TYPE
SYNTAX INTEGER(1..7)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The window size parameter controls the number of I frames which
may be transmitted without acknowledgement in EXTC mode."
DEFVAL { 1 }
::= { wfSyncEntry 28 }
wfSyncMinFrameSpace OBJECT-TYPE
SYNTAX INTEGER(1..32)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The minimum frame spacing parameter defines the number of flags
that are transmitted between adjacent frames."
DEFVAL { 1 }
::= { wfSyncEntry 29 }
wfSyncLocalAddress OBJECT-TYPE
SYNTAX INTEGER {
addressdte(3),
addressdce(1),
addressexplicit(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The local address parameter contains the DTE,DCE or EXPLICIT
value expressed as a single octet. It may be extended to 2
octets if EXTA has been set."
DEFVAL { addressexplicit }
::= { wfSyncEntry 30 }
wfSyncRemoteAddress OBJECT-TYPE
SYNTAX INTEGER {
addressdte(3),
addressdce(1),
addressexplicit(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The remote address parameter contains the DTE,DCE or EXPLICIT
value expressed as a single octet. It may be extended to 2
octets if EXTA has been set."
DEFVAL { addressexplicit }
::= { wfSyncEntry 31 }
wfSyncPassThruLocalMadr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"48 bit MAC address of Local end of Sync Passthru circuit"
::= { wfSyncEntry 32 }
wfSyncPassThruRemoteMadr OBJECT-TYPE
SYNTAX OCTET STRING
ACCESS read-write
STATUS mandatory
DESCRIPTION
"48 bit MAC address of Remote end of Sync Passthru circuit"
::= { wfSyncEntry 33 }
wfSyncWanProtocol OBJECT-TYPE
SYNTAX INTEGER {
standard(1),
passthru(2),
ppp(3),
smds(4),
framerelay(5),
x25(6),
switch(7),
sw(8),
atm(9),
lapb(10),
sdlc(11),
aot(12)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"WAN protocol selection is provided via this parameter. The
supported protocols can be selected per interface."
DEFVAL { standard }
::= { wfSyncEntry 34 }
wfSyncCrcSize OBJECT-TYPE
SYNTAX INTEGER {
crc16bit(1),
crc32bit(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"CRC size parameter, 16 bit standard CCITT or extended 32 bit CRC"
DEFVAL { crc16bit }
::= { wfSyncEntry 35 }
wfSyncRxOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets received without error"
::= { wfSyncEntry 36 }
wfSyncRxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames received without error"
::= { wfSyncEntry 37 }
wfSyncTxOctets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of octets transmitted without error"
::= { wfSyncEntry 38 }
wfSyncTxFrames OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames transmitted without error"
::= { wfSyncEntry 39 }
wfSyncRxErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of receive errors"
::= { wfSyncEntry 40 }
wfSyncTxErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of transmission errors"
::= { wfSyncEntry 41 }
wfSyncLackRescRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Rx frames dropped due to lack of buffer resources"
::= { wfSyncEntry 42 }
wfSyncLackRescTx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames clipped in driver's transmit routine due to transmit
congestion."
::= { wfSyncEntry 43 }
wfSyncUnderFlowTx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of transmission underflows, device FIFO went empty before
next DMA request was granted."
::= { wfSyncEntry 44 }
wfSyncRejectsTx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"For the mk50 driver: Number of reject frames which were
transmitted
For the quicsync driver: Not used
For the quicsync driver in Async mode: Number of frames
that grew, due to escaping, larger than a buffer"
::= { wfSyncEntry 45 }
wfSyncRejectsRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"For the mk50 driver: Number of reject frames which were
received
For the quicsync driver: Number of HDLC frames received with
a non-matching address
For the quicsync driver in Async mode: Number of frames
received that did not fit within a buffer"
::= { wfSyncEntry 46 }
wfSyncOverFlowRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of receive overflows, device FIFO overflowed before next
DMA cycle granted. No buffer resources available."
::= { wfSyncEntry 47 }
wfSyncFramesIncompRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames which were incompletely received. These are frames
which may have resulted from FRMRR errors."
::= { wfSyncEntry 48 }
wfSyncBadFramesRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bad receive frames, caused by FCS errors or non octet aligned."
::= { wfSyncEntry 49 }
wfSyncFrameRejectsRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Frame Rejects received"
::= { wfSyncEntry 50 }
wfSyncRuntsRx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of runt frames received or number of frames where
the Carrier Detect signal was lost during reception."
::= { wfSyncEntry 51 }
wfSyncT1Timeouts OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of T1 timeout's detected. The T1 timer is the link
retransmission timer. Link control frames will be retransmitted
when T1 expires. This is a count of the number of timeouts."
::= { wfSyncEntry 52 }
wfSyncMemoryErrors OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of memory access errors detected. A MERR is the expiration of
a DMA cycle without the bus being granted within 26us."
::= { wfSyncEntry 53 }
wfSyncMediaType OBJECT-TYPE
SYNTAX INTEGER {
default(1),
t1(2),
e1(3),
raisedtr(4),
v25bis(5),
bri(6),
isdnleased(7),
hayes(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Media type selection is provided via this parameter"
DEFVAL { default }
::= { wfSyncEntry 54 }
wfSyncCfgTxQueueLength OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Configured Transmit Queue Length. Values other than zero over-ride the
router selected values. A value of zero has a special meaning. Zero
causes router based default values to be used. Values larger than the
compiled ring size are truncated to the compiled ring size. "
::= { wfSyncEntry 55 }
wfSyncCfgRxQueueLength OBJECT-TYPE
SYNTAX INTEGER(0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Configured Receive Queue Length. Values other than zero over-ride the
router selected values. A value of zero has a special meaning. Zero
causes router based default values to be used. Values larger than the
compiled ring size are truncated to the compiled ring size. "
::= { wfSyncEntry 56 }
wfSyncTxQueueLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Transmit Queue Length."
::= { wfSyncEntry 57 }
wfSyncRxQueueLength OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Current Receive Queue Length."
::= { wfSyncEntry 58 }
wfSyncRxReplenMisses OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of packet buffer misses while attempting to replenish driver
receive ring."
::= { wfSyncEntry 59 }
wfSyncStartUpMode OBJECT-TYPE
SYNTAX INTEGER {
active(1),
passive(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Initiation of link level for LLC2 running LAPB"
DEFVAL { active }
::= { wfSyncEntry 60 }
wfSyncIdleRRFrames OBJECT-TYPE
SYNTAX INTEGER {
on(1),
off(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Transmit Link level RR's (Reciever Readys) during idle time. Every
wfSyncLinkIdleTimer expiration an RR will be sent."
DEFVAL { off }
::= { wfSyncEntry 61 }
wfSyncMultilineMode OBJECT-TYPE
SYNTAX INTEGER {
standard(1),
monitor(2),
primary(3),
secondary(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This indicates the roll the sync line plays in a
Bandwidth on Demand multiline circuit. If this is
not BOD, the mode is standard."
DEFVAL { standard }
::= { wfSyncEntry 62 }
wfSyncBODExamPeriod OBJECT-TYPE
SYNTAX INTEGER(5..200)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This indicates the interval that the line should
be polled for possible congestion. This value is in
tenths of a second"
DEFVAL { 10 }
::= { wfSyncEntry 63 }
wfSyncBODFullThreshold OBJECT-TYPE
SYNTAX INTEGER(10..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the percentage of the theoretical maximum line
throughput that must be reached or exceeded before the line is
considered congested."
DEFVAL { 70 }
::= { wfSyncEntry 64 }
wfSyncBODRecoverThreshold OBJECT-TYPE
SYNTAX INTEGER(10..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the recovery threshold expressed as a percentage of the
theoretical maximum line throughput. The actual throughput must fall
below this percentage in order for the BOD circuit to
revert back to the primary line only. This value should be
set to less than one half the value of wfSyncBODFullThreshold
to avoid toggling the secondary."
DEFVAL { 20 }
::= { wfSyncEntry 65 }
wfSyncBODPeriodsToFail OBJECT-TYPE
SYNTAX INTEGER(1..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the number of consecutive periods where the line
throughput is above the congestion threshold required to declare
the line congested."
DEFVAL { 10 }
::= { wfSyncEntry 66 }
wfSyncKG84ACycle OBJECT-TYPE
SYNTAX INTEGER {
cycle5ms(5),
cycle10ms(10),
cycle25ms(25),
cycle50ms(50),
cycle100ms(100),
cycle200ms(200),
cycle500ms(500)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Monitor sample time in milliseconds"
DEFVAL { cycle100ms }
::= { wfSyncEntry 67 }
wfSyncKG84ASyncLossInterval OBJECT-TYPE
SYNTAX INTEGER {
num2cycles(2),
num5cycles(5),
num10cycles(10),
num25cycles(25),
num50cycles(50),
num100cycles(100),
num200cycles(200),
num500cycles(500)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"timer starts when FCS error detected; if no good frame received
during this time, declare loss of synchronization"
DEFVAL { num50cycles }
::= { wfSyncEntry 68 }
wfSyncKG84ARemoteResyncWait OBJECT-TYPE
SYNTAX INTEGER {
num2cycles(2),
num5cycles(5),
num10cycles(10),
num25cycles(25),
num50cycles(50),
num100cycles(100),
num200cycles(200),
num500cycles(500)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"when loss of synchronization is detected, and CTS is low, start timer; if
CTS is not high when timer expires, force sync request"
DEFVAL { num200cycles }
::= { wfSyncEntry 69 }
wfSyncKG84ASyncPulse OBJECT-TYPE
SYNTAX INTEGER(2..4096)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"interval to pulse KG84a SYNC signal, in milliseconds"
DEFVAL { 10 }
::= { wfSyncEntry 70 }
wfSyncKG84AResyncs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of KG84 resyncs performed"
::= { wfSyncEntry 71 }
wfSyncKG84AResyncsDetected OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"number of KG84 resyncs detected"
::= { wfSyncEntry 72 }
wfSyncKG84ABsu OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"value taken from mk5025 sync chip control block"
::= { wfSyncEntry 73 }
wfSyncKG84AState OBJECT-TYPE
SYNTAX INTEGER {
idle(1),
local(2),
remote(3),
sync(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"state of sync"
DEFVAL { idle }
::= { wfSyncEntry 74 }
wfSyncKG84AOkFrames OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"count of valid frames received. This value taken from normal sync
processing, updated by timer routine when FCE error detected"
::= { wfSyncEntry 75 }
wfSyncPollingEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Enable or Disable Sync Polling. When Sync Polling is enabled, the
the Sync Driver will be disabled if the DSR lead is dropped. If
disabled, the DSR lead is ignored."
DEFVAL { disabled }
::= { wfSyncEntry 76 }
wfSyncBackupPool OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Backup pool id containing this line driver"
::= { wfSyncEntry 77 }
wfSyncDemandPool OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Dial on demand pool id containing this line driver"
::= { wfSyncEntry 78 }
wfSyncLineNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"line number for this line instance"
::= { wfSyncEntry 79 }
wfSyncHoldDownTime OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Wait this number of seconds before bringing the line
up. This prevents line waffling if this is a
reactivated primary line in a backup configuration
and it is a dirty line"
::= { wfSyncEntry 80 }
wfSyncNetworkType OBJECT-TYPE
SYNTAX INTEGER {
gosip(1),
net2(2),
c03(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specific Network Link Level to be executed, LAPB mode only.
The types GOSIP and NET2 are used in conjunction with an MK5025
chip revision C04. If a customer must be NET2 compliant and is
using an MK5025 chip revision C03, the C03 option must be used."
DEFVAL { net2 }
::= { wfSyncEntry 81 }
wfSyncActiveCct OBJECT-TYPE
SYNTAX INTEGER(1..1023)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Active CCT number for this line instance"
::= { wfSyncEntry 82 }
wfSyncCableType OBJECT-TYPE
SYNTAX INTEGER(0..4)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of Cable attached to the sync port - this is
needed for V.25bis and Raise DTR to properly
communicate with the modem"
::= { wfSyncEntry 83 }
wfSyncRxDropPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Rx packets dropped by driver."
::= { wfSyncEntry 84 }
wfSyncTxDropPackets OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Tx packets dropped by driver."
::= { wfSyncEntry 85 }
wfSyncModule OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
three(3),
four(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Module number for ASN platform, filled in by driver. For non-ASN
platforms this attribute will not be used."
::= { wfSyncEntry 86 }
wfSyncActualConnector OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2),
three(3),
four(4),
five(5),
six(6),
seven(7),
eight(8)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Actual connector number for ASN platform, filled in
by driver. For non-ASN platforms, this attribute will
not be used."
::= { wfSyncEntry 87 }
wfSyncLineCoding OBJECT-TYPE
SYNTAX INTEGER {
nrz(1),
nrzi(2),
nrzimark(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Line Coding for sync interface. Can be either NRZ or NRZI."
DEFVAL { nrz }
::= { wfSyncEntry 88 }
wfSyncLastChange OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of SysUpTime at the time the interface entered it's current
operational state (UP state). SysUpTime is defined as the time (in
hundredths of a second) since the network management portion of the
system was last re-initialized. Usually the time since boot."
::= { wfSyncEntry 89 }
wfSyncOutQLen OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The instantaneous current length of the output packet queue (in packets)."
::= { wfSyncEntry 90 }
wfSyncRemoteLpbkDetection OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute enables Remote Loopback Detection. When enabled along with
wfSyncBofl, the device driver will detect when it is receiving its own
BOFL packets and will bring the interface down assuming that somewhere
down stream the link has been put into loopback. "
DEFVAL { disabled }
::= { wfSyncEntry 91 }
wfSyncLastState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
init(3),
wait(4),
notpresent(5),
dsrwait(6),
holddown(7),
remoteloop(8),
notpres(20)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state which the driver was in prior to the most recent
re-initialization."
::= { wfSyncEntry 92 }
wfSyncExternalClkSpeed OBJECT-TYPE
SYNTAX INTEGER(1200..6000000)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"External Clock Speed. If external clocking is configured, this attribute
should be set to the clock speed of the externally supplied clock.
Depending on the protocols configured on this interface, this value may
control internal decision making within the router. In some cases, router
software uses this attribute for route selection. If Priority Queuing is
configured, it chooses queue depths based on this attribute. This attribute
has no effect when Internal clocking is configured."
DEFVAL { 64102 }
::= { wfSyncEntry 93 }
wfSyncBChannelOverride OBJECT-TYPE
SYNTAX INTEGER {
bchannel1(1),
bchannel2(2),
default(3),
floatingb(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"For ISDN, indicates which B Channel we're using. By default, we'd like
the B Channel tied to the connector defined in the instance id, but
the user may override that here, which gives the ability of connecting
the B Channel to specific SCC's."
DEFVAL { default }
::= { wfSyncEntry 94 }
wfSyncBChannel OBJECT-TYPE
SYNTAX INTEGER {
bchannel1(1),
bchannel2(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates which B Channel is running"
::= { wfSyncEntry 95 }
wfSyncForceIFTF OBJECT-TYPE
SYNTAX INTEGER {
default(1),
forcehdlcflags(2),
forceidles(3),
flagstreaming(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the Inter Frame Time Fill (IFTF) pattern which gets transmitted
when no data is being transmitted on a particular channel.
For SDLC Lines, DEFAULT and FORCE_HDLC_FLAGS both result in
HDLC Flags (0x7E) as the fill character.
FLAGSTREAMING will cause the fill character to alternate between
Flags (0x7E) and Idles (0xFF), depending upon the current state of the line.
For ISDN BRI Lines, DEFAULT, FORCE IDLES and FLAGSTREAMING all
result in Idles (0xFF) as the fill character.
For all other line types, DEFAULT, FORCE HDLC FLAGS and FLAGSTREAMING all
result in HDLC Flags (0x7E) as the fill character.
Leave this field at the default unless required for the attached
device. The AS/400 high speed serial controller requires the use of
FLAGSTREAMING for error-free operation."
DEFVAL { default }
::= { wfSyncEntry 96 }
wfSyncPriority OBJECT-TYPE
SYNTAX INTEGER(1..50)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used by dial/switched services to assign priority of lines
within the same demand or backup pool"
DEFVAL { 1 }
::= { wfSyncEntry 97 }
wfSyncTurboBofl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DEBUG parameter - Turbo bofl enabled or disabled"
DEFVAL { disabled }
::= { wfSyncEntry 98 }
wfSyncBoflNum OBJECT-TYPE
SYNTAX INTEGER(1..127)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DEBUG parameter - Number of breath of life packets per breath
of life"
DEFVAL { 1 }
::= { wfSyncEntry 99 }
wfSyncBoflLen OBJECT-TYPE
SYNTAX INTEGER(22..4450)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DEBUG parameter - breath of life packet length"
DEFVAL { 200 }
::= { wfSyncEntry 100 }
wfSyncTurboBoflMisses OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DEBUG parameter - breath of life allocation failures"
::= { wfSyncEntry 101 }
wfSyncTurboBoflInvocations OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DEBUG parameter - breath of life invocations"
::= { wfSyncEntry 102 }
wfSyncBandwidthOnDemandPool OBJECT-TYPE
SYNTAX INTEGER(1..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Bandwidth pool id containing this line driver"
::= { wfSyncEntry 103 }
wfSyncBODRecoverPeriodsToPass OBJECT-TYPE
SYNTAX INTEGER(1..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This is the number of consecutive periods where the queue
depth is below the congestion threshold required to declare
the line congested. It is used for recovery. That is,
once a line is declared as congested, this is the number of
consecutive examination periods where the queue depth is
below the recovery threshold value required to delare that the
line is no longer congested."
DEFVAL { 10 }
::= { wfSyncEntry 104 }
wfSyncBODHistory OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"DEBUG parameter - This is the SBOD history buffer."
::= { wfSyncEntry 105 }
wfSyncBODDebugFlag OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"DEBUG parameter - This is the SBOD Debug flag, used to control
debug code for SBOD."
::= { wfSyncEntry 106 }
wfSyncBChRateAdaption OBJECT-TYPE
SYNTAX INTEGER {
adaption64k(1),
adaption128k(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute is only relevant when this Synchronous device driver
is performing as an ISDN B channel over a BRI interface in leased
line mode. This attribute specifies the piece of ISDN line's bandwidth
which data from this driver will occupy. "
DEFVAL { adaption64k }
::= { wfSyncEntry 107 }
wfSyncBChActualRateAdaption OBJECT-TYPE
SYNTAX INTEGER {
adaption64k(1),
adaption128k(2),
adaption56kmsb(3),
adaption56klsb(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Indicates the current B Channel Rate Adaption in use. This attribute
is only relevant when this Synchronous device driver is performing
as an ISDN B channel over a BRI interface in leased line or dial-up
mode. This attribute indicates the speed of this B-channel. It also
specifies their bit positions for the case of 56K selections."
::= { wfSyncEntry 108 }
wfSyncWanType OBJECT-TYPE
SYNTAX INTEGER {
synchronous(1),
asynchronous(2),
pasynchronous(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This attribute indicates whether this port should be
configured as a SYNCHRONOUS or UART/ASYNCHRONOUS interface."
DEFVAL { synchronous }
::= { wfSyncEntry 109 }
wfSyncAsyncBaudRate OBJECT-TYPE
SYNTAX INTEGER {
baudrate1200b(1200),
baudrate2400b(2400),
baudrate4800b(4800),
baudrate7200b(7200),
baudrate9600b(9600),
baudrate12000b(12000),
baudrate14400b(14400),
baudrate19200b(19200),
baudrate28800b(28800),
baudrate38k(38400),
baudrate56k(57600),
baudrate64k(64000),
baudrate76k(76800),
baudrate96k(96000),
baudrate115k(115200)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the baud rate of the Tx/Rx character stream.
This value should always be >= than speed at which the
modems connect, but is independent of that speed.
For instance, for V34 modems, the maximum modular
connection speed is 28800 kbps. If your modems can
do V.42 bis or MNP 5 data compression, with high
(4 to 1) compression ratios you could fill a 115Kbps
pipe."
DEFVAL { baudrate9600b }
::= { wfSyncEntry 110 }
wfSyncCfgAsyncCmndMaxIdles OBJECT-TYPE
SYNTAX INTEGER(1..500)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum number of idles we'll receive (in Command Mode)
between ASYNC frames. Values other than zero over-ride the
router selected values. A value of zero has a special
meaning. Zero causes router based defaults to be used.
This attribute is used to delineate frames when the QUICC
is configured for UART/ASYNCHRONOUS mode."
::= { wfSyncEntry 111 }
wfSyncAsyncCmndMaxIdles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum number of idles we'll receive (in Command Mode)
(i.e. when the modems have not yet connected & entered
data state), before closing the ASYNC frame. This value
is used to delineate frames when receiving data when the
SYNC port is configured for UART/ASYNCHRONOUS mode."
::= { wfSyncEntry 112 }
wfSyncCfgAsyncDataMaxIdles OBJECT-TYPE
SYNTAX INTEGER(1..500)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Maximum number of idles we'll receive (in Data Mode)
between ASYNC frames. Values other than zero over-ride the
router selected values. A value of zero has a special
meaning. Zero causes router based defaults to be used.
This attribute is used to delineate frames when the QUICC
is configured for UART/ASYNCHRONOUS mode."
::= { wfSyncEntry 113 }
wfSyncAsyncDataMaxIdles OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Maximum number of idles we'll receive (in Command Mode)
(i.e. when the modems have connected & entered data state),
before closing the ASYNC frame. This value is used to
delineate frames when receiving data when the SYNC port is
configured for UART/ASYNCHRONOUS mode."
::= { wfSyncEntry 114 }
wfSyncFramesAbortTx OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of frames where CTS was lost during transmission."
::= { wfSyncEntry 115 }
wfSyncPasyncParityType OBJECT-TYPE
SYNTAX INTEGER {
odd(1),
even(2),
high(3),
low(4),
none(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Type of parity chosen for Polled Async"
DEFVAL { even }
::= { wfSyncEntry 116 }
wfSyncPasyncCharacterLength OBJECT-TYPE
SYNTAX INTEGER {
five(5),
six(6),
seven(7),
eight(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of data bits chosen for Polled Async"
DEFVAL { eight }
::= { wfSyncEntry 117 }
wfSyncPasyncStopLength OBJECT-TYPE
SYNTAX INTEGER {
one(1),
two(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Number of stop bits chosen for Polled Async"
DEFVAL { two }
::= { wfSyncEntry 118 }
wfSyncPasyncBaudRate OBJECT-TYPE
SYNTAX INTEGER {
baudrate150b(150),
baudrate300b(300),
baudrate600b(600),
baudrate1200b(1200),
baudrate2400b(2400),
baudrate4800b(4800),
baudrate7200b(7200),
baudrate9600b(9600),
baudrate12000b(12000),
baudrate14400b(14400),
baudrate19200b(19200),
baudrate28800b(28800),
baudrate38k(38400),
baudrate56k(57600),
baudrate64k(64000),
baudrate76k(76800),
baudrate96k(96000),
baudrate115k(115200)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Indicates the baud rate of the Tx/Rx character stream.
This value should always be >= than speed at which the
modems connect, but is independent of that speed.
For instance, for V34 modems, the maximum modular
connection speed is 28800 kbps. If your modems can
do V.42 bis or MNP 5 data compression, with high
(4 to 1) compression ratios you could fill a 115Kbps
pipe."
DEFVAL { baudrate600b }
::= { wfSyncEntry 119 }
wfSyncLocalConnectionState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
unknown(3)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the cable at the router end."
DEFVAL { unknown }
::= { wfSyncEntry 120 }
wfSyncRemoteConnectionState OBJECT-TYPE
SYNTAX INTEGER {
up(1),
down(2),
devicestreaming(3),
unknown(4)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the cable at the device end."
DEFVAL { unknown }
::= { wfSyncEntry 121 }
wfSyncTimeSlotAssignment OBJECT-TYPE
SYNTAX DisplayString
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Lists the time-slots which constitute this channel. Read only
attribute that contains a list of time-slots from 1 to 24
used by the channel assigned to the FT1 card. It contains
a list of the timeslots from 1 to 32 for the G.703 card."
::= { wfSyncEntry 122 }
wfSyncEiaStatus OBJECT-TYPE
SYNTAX INTEGER {
txd(1),
rxd(2),
rts(4),
cts(8),
dsr(16),
dcd(32),
txc(64),
rxc(128),
dtr(256),
txdToggled(65536),
rxdToggled(131072),
rtsToggled(262144),
ctsToggled(524288),
dsrToggled(1048576),
dcdToggled(2097152),
txcToggled(4194304),
rxcToggled(8388608),
dtrToggled(16777216)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The state of the EIA signals at the router interface.
The signals are designated as bits in this entry. If the
signal is asserted, it is marked as a 1. If not asserted,
it is marked as a 0. The state of each signal will be updated
every second. Bits 0-15 are reserved for actual signal state.
Bits 16-31 are reserved for indicating toggling of the signal.
Toggling signals are indicated as a 1. Signals not toggling
are indicated with a 0.
The following signals are defined and monitored:
The bit definition as as follows with bit #0 being the LSB.
* signal status - bits 0-15 *
bit 0 = TXD transmit data
1 = RXD receive data
2 = RTS request to send
3 = CTS clear to send
4 = DSR data set ready
5 = DCD data carrier detect
6 = TXC transmit clock
7 = RXC receive clock
8 = DTR data terminal ready.
* signal toggle status bits 16-31 *
bit 16 = TXD transmit data
17 = RXD receive data
18 = RTS request to send
19 = CTS clear to send
20 = DSR data set ready
21 = DCD data carrier detect
22 = TXC transmit clock
23 = RXC receive clock
24 = DTR data terminal ready."
::= { wfSyncEntry 123 }
wfSyncEiaStatusReset OBJECT-TYPE
SYNTAX INTEGER {
reset(1),
noaction(21)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Reset The EIA status for the EIA signals in wfSyncEiaStatus.
This is particularly useful for clearing the toggle status. "
DEFVAL { noaction }
::= { wfSyncEntry 124 }
wfSyncUcastMap OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Used to map ifEntry.ifInUcastPkts to wfSyncRxFrames and
ifEntry.ifOutUcastPkts to wfSyncTxFrames."
DEFVAL { disabled }
::= { wfSyncEntry 125 }
END