SNMP MIB Search

Return to vendor list
View mib
Download mib file
Mib: Wellfleet-DS3E3-MIB
Version: 1


Objects
Scalar Object
wfDs3E3ConfigEntry.1.3.6.1.4.1.18.3.4.26.10.1
per circuit DS3/E3 configuration objects;
wfDs3E3ConfigLineIndex corresponds to Wellfleet circuit number
wfDs3E3ActionEntry.1.3.6.1.4.1.18.3.4.26.17.1
An entry in the DS3E3 Config table
Tabular Object
wfDs3E3ConfigLineIndex.1.3.6.1.4.1.18.3.4.26.10.1.5
this corresponds to the Wellfleet circuit number
wfDs3E3ConfigDelete.1.3.6.1.4.1.18.3.4.26.10.1.1
Create/Delete parameter
wfDs3E3ConfigDisable.1.3.6.1.4.1.18.3.4.26.10.1.2
Enable/Disable parameter
wfDs3E3ConfigState.1.3.6.1.4.1.18.3.4.26.10.1.3
State of the DS3 Port.
wfDs3E3ConfigLastChange.1.3.6.1.4.1.18.3.4.26.10.1.4
The value of sysUpTime at the time the interface entered
its current operational state.
wfDs3E3ConfigIfIndex.1.3.6.1.4.1.18.3.4.26.10.1.6
this is value of ifIndex from the Interfaces table of
MIB II (RFC 1213).
wfDs3E3ConfigLineType.1.3.6.1.4.1.18.3.4.26.10.1.7
the variety of DS3/E3 application implementing this circuit
wfDs3E3ConfigLineCoding.1.3.6.1.4.1.18.3.4.26.10.1.8
the variety of Zero Code Suppression used on the link
wfDs3E3ConfigLoopbackConfig.1.3.6.1.4.1.18.3.4.26.10.1.9
the loopback configuration of the DS3/E3 interface
wfDs3E3ConfigLineStatus.1.3.6.1.4.1.18.3.4.26.10.1.10
the status of the DS3/E3 line
wfDs3E3ConfigPrimaryClockSource.1.3.6.1.4.1.18.3.4.26.10.1.11
Selects the Primary source of the Tx Clock for the DS3/E3
interface
wfDs3E3ConfigSecondaryClockSource.1.3.6.1.4.1.18.3.4.26.10.1.12
Selects the Secondary source of the Tx Clock for the DS3/E3
interface
wfDs3E3ConfigMtu.1.3.6.1.4.1.18.3.4.26.10.1.13
MTU parameter for all channels on DS3 .
wfDs3E3ConfigLineBuildOut.1.3.6.1.4.1.18.3.4.26.10.1.14
Set according to cable length, short (less than 225 feet)
or long (greater than 225 feet).
wfDs3E3ConfigCurrentClock.1.3.6.1.4.1.18.3.4.26.10.1.15
Indicates the clock source currently in use by the DS1
wfDs3E3ConfigExtClockOperational.1.3.6.1.4.1.18.3.4.26.10.1.16
Indicates whether the External clock is operational
wfDs3E3ConfigSetupAlarmThreshold.1.3.6.1.4.1.18.3.4.26.10.1.17
Specifies setup time for performance failure conditions,
in seconds. When a performance defect is present for greater
than the time specified by this parameter a performance
failure is registered and a message is logged.
wfDs3E3ConfigClearAlarmThreshold.1.3.6.1.4.1.18.3.4.26.10.1.18
Specifies clear time for performance failure conditions,
in seconds. When a performance failure condition has been
cleared for greater than the time specified by this parameter
then the failure cleared condition is registered and a
message is logged.
wfDs3E3ConfigLoopbackState.1.3.6.1.4.1.18.3.4.26.10.1.19
Indicates the current loopback state of this interface.
The interface can be in one the following states:
Line Loopback
Payload Loopback
no loopback
Loopback modes can be initiated by either of two methods:
Manager requested Loopback is initiated by the Manager of
this device.
Network requested Loopback is initiated by this interface
receiving an in-band request on the network from the far
end device.
wfDs3E3ConfigSendCode.1.3.6.1.4.1.18.3.4.26.10.1.20
This variable is currently read-only and it indicates what type of code has
been sent across the DS3 interface by the device.  The values mean:
SENDNOCODE - sending looped or normal data
SENDLINECODE - sending a request for a line loopback
SENDPAYLOADCODE - sending a request for a payload loopback
SENDDS1LOOPCODE - sending a request for a DS1 loopback
wfDs3E3ActionPortLineNumber.1.3.6.1.4.1.18.3.4.26.17.1.1
Instance ID LineNumber, filled in by driver
wfDs3E3ActionSendFeacLoopCode.1.3.6.1.4.1.18.3.4.26.17.1.2
Selects a Far End Alarm and Control Channel code to be
sent to the remote end.
wfDs3E3ActionSendFeacDs1LoopUpCode.1.3.6.1.4.1.18.3.4.26.17.1.3
Selects Loop Up code to be sent to the remote end for a DS1.
Value passed through this attribute is the DS1 Port number
(1 through 28).
wfDs3E3ActionSendFeacDs1LoopDownCode.1.3.6.1.4.1.18.3.4.26.17.1.4
Selects Loop Down code to be sent to the remote end for a DS1.
Value passed through this attribute is the DS1 Port number
(1 through 28).
wfDs3E3ActionClearCurrentStats.1.3.6.1.4.1.18.3.4.26.17.1.5
Clears this port's Current 15 minute Statistics.
wfDs3E3ActionClearFarEndCurrentStats.1.3.6.1.4.1.18.3.4.26.17.1.6
Clears this port's Far End, Current 15 minute Statistics.
wfDs3E3ActionClearDayCurrentStats.1.3.6.1.4.1.18.3.4.26.17.1.7
Clears this port's Current Day Statistics.
wfDs3E3ActionClearFarEndDayCurrentStats.1.3.6.1.4.1.18.3.4.26.17.1.8
Clears this port's Far End, Current Day Statistics.
wfDs3E3ActionClearIntervalStats.1.3.6.1.4.1.18.3.4.26.17.1.9
Clears All Interval Statistics (15 minute and day) of this port.
wfDs3E3ActionClearFarEndIntervalStats.1.3.6.1.4.1.18.3.4.26.17.1.10
Clears All Far End Interval Statistics (15 minute and day) of this port.
Table
wfDs3E3ConfigTable.1.3.6.1.4.1.18.3.4.26.10
The DS3/E3 Configuration table
wfDs3E3ActionTable.1.3.6.1.4.1.18.3.4.26.17
DS3E3 configuration Action record -
write only Configuration parameters
Copyright (c) Tandem Systems, Ltd., 2002-2011