ANNEX-MIB DEFINITIONS ::= BEGIN
IMPORTS
enterprises, NetworkAddress, IpAddress,
Counter, Gauge, TimeTicks
FROM RFC1155-SMI
DisplayString, PhysAddress
FROM RFC1213-MIB
OBJECT-TYPE
FROM RFC-1212;
xylogics OBJECT IDENTIFIER ::= { enterprises 15 }
prod OBJECT IDENTIFIER ::= { xylogics 1 }
prodannex OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Product name."
::= { prod 1 }
annex OBJECT IDENTIFIER ::= { xylogics 2 }
hw OBJECT IDENTIFIER ::= { annex 1 }
sw OBJECT IDENTIFIER ::= { annex 2 }
ports OBJECT IDENTIFIER ::= { annex 3 }
parallelport OBJECT IDENTIFIER ::= { annex 4 }
annexconfig OBJECT IDENTIFIER ::= { annex 5 }
annexcmds OBJECT IDENTIFIER ::= { annex 6 }
hwType OBJECT-TYPE
SYNTAX INTEGER {
err(1),
annexII(16),
annex3(42),
microannex(52),
microels(55)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"An identifier for the Annex hardware type."
::= { hw 1 }
hwRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The revision level of the hardware platform."
::= { hw 2 }
romRev OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The revision number of the ROM Monitor software."
::= { hw 3 }
serialNumber OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The serial number assigned to the unit."
::= { hw 4 }
memorySize OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of memory present in the unit."
::= { hw 5 }
swType OBJECT-TYPE
SYNTAX INTEGER {
err(1),
annexIImx(16),
annexIIux(17),
annex3ux(42),
annex3mx(43),
microannexux(52),
microannexmx(53),
microels(55)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The software version currently running on
the Annex."
::= { sw 1 }
swRevMajor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The major software release number."
::= { sw 2 }
swRevMinor OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minor software release number."
::= { sw 3 }
swBuild OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The full name of the software build, including
the software version, major and minor version
numbers and the date and time of the build."
::= { sw 4 }
imageName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The name of the most recently booted image."
::= { sw 5 }
bootHost OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The Internet address of the host from which
the Annex booted."
::= { sw 6 }
defaultDomain OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The default domain name provided by the DNS
nameserver."
::= { sw 7 }
currentDate OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current date and time provided by the time
server."
::= { sw 8 }
usableMemory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of available for data buffers and
other structures after the Annex has booted."
::= { sw 9 }
freeMemory OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The amount of currently available memory."
::= { sw 10 }
minFreeMemory OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum amount of free memory since booting
the Annex."
::= { sw 11 }
cpuUtilization OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Percent of CPU time currently being used."
::= { sw 12 }
maxProcs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of process structures
allocated for use."
::= { sw 13 }
mostProcs OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The maximum number of active processes since
the Annex was booted."
::= { sw 14 }
activeProcs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of currently active processes."
::= { sw 15 }
cpuIRescheds OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of processes whose time slice has
expired in the last minute."
::= { sw 16 }
cpuTRescheds OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of processes whose time slice
has expired since booting the Annex."
::= { sw 17 }
contextISwtchs OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of context switches in the last
minute."
::= { sw 18 }
contextTSwtchs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of context switches since
booting the Annex."
::= { sw 19 }
cpuIActivates OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of processes that were activated
in the last minute."
::= { sw 20 }
cpuTActivates OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of processes that were activated
since booting the Annex."
::= { sw 21 }
maxCallouts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of allocated Callout structures
for timed events in the Annex."
::= { sw 22 }
leastCallouts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The minimum number of Callout structures
available since last booting the Annex."
::= { sw 23 }
freeCallouts OBJECT-TYPE
SYNTAX Gauge
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current number of free Callout structures."
::= { sw 24 }
totalPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of serial ports on this Annex."
::= { ports 1 }
totalInChars OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of characters received on all
serial ports."
::= { ports 2 }
totalOutChars OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of characters transmitted on
all serial ports."
::= { ports 3 }
totalParityErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of parity errors detected
on all serial ports."
::= { ports 4 }
totalOverrunErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of overruns detected on all
serial ports."
::= { ports 5 }
totalFramingErrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The total number of framing errors detected
on all serial ports."
::= { ports 6 }
portTable OBJECT-TYPE
SYNTAX SEQUENCE OF PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of port entries."
::= { ports 7 }
portEntry OBJECT-TYPE
SYNTAX PortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The port's configuration parameters."
INDEX { anxpPortIndex }
::= { portTable 1 }
PortEntry ::= SEQUENCE {
anxpPortIndex INTEGER,
anxpMode INTEGER,
anxpCtrlLines INTEGER,
anxpBidirModem INTEGER,
anxpAllowBcast INTEGER,
anxpBcastDirection INTEGER,
anxpInputStartChar DisplayString,
anxpInputStopChar DisplayString,
anxpOutputStartChar DisplayString,
anxpOutputStopChar DisplayString,
anxpIxanyFlowCtl INTEGER,
anxpLongBreak INTEGER,
anxpShortBreak INTEGER,
anxpForwardTimer INTEGER,
anxpForwardCount INTEGER,
anxpImask7Bits INTEGER,
anxpAttnChar DisplayString,
anxpInputBufSize INTEGER,
anxpInputIsActivity INTEGER,
anxpOutputIsActivity INTEGER,
anxpInactivityTimer INTEGER,
anxpResetIdleTimer INTEGER,
anxpCliInactivity INTEGER,
anxpCliSecurity INTEGER,
anxpConnectSecurity INTEGER,
anxpPortServerSecurity INTEGER,
anxpPortPassword DisplayString,
anxpUserName DisplayString,
anxpDedicatedAddr IpAddress,
anxpDedicatedPort DisplayString,
anxpPrompt DisplayString,
anxpTermVar DisplayString,
anxpNewLineTerm INTEGER,
anxpEcho INTEGER,
anxpMapToLower INTEGER,
anxpMapToUpper INTEGER,
anxpHardwareTabs INTEGER,
anxpCharErase INTEGER,
anxpLineErase INTEGER,
anxpEraseChar DisplayString,
anxpEraseWord DisplayString,
anxpEraseLine DisplayString,
anxpRedisplayLine DisplayString,
anxpToggleOutput DisplayString,
anxpTelnetEscape DisplayString,
anxpNeedDsr INTEGER,
anxpTelnetCRLF INTEGER,
anxpLatbEnable INTEGER,
anxpSlipSecure INTEGER,
anxpNetLocalAddr IpAddress,
anxpNetRemoteAddr IpAddress,
anxpSlipSubnetMask IpAddress,
anxpSlipLoadDumpHost IpAddress,
anxpNetMetric INTEGER,
anxpSlipAllowDump INTEGER,
anxpSlipDoCompression INTEGER,
anxpSlipAllowCompression INTEGER,
anxpSlipMtuSize INTEGER,
anxpSlipNoIcmp INTEGER,
anxpSlipTos INTEGER,
anxpPppMru INTEGER,
anxpPppAcm INTEGER,
anxpPppSecurityProto INTEGER,
anxpPppUserRemote DisplayString,
anxpPppPasswdRemote DisplayString,
anxpLatAuthGroupVal DisplayString,
anxpPppDialupAddr INTEGER,
anxpBanner INTEGER,
anxpPsHistory INTEGER,
anxpLocation DisplayString,
anxpType INTEGER,
anxpCliImask7 INTEGER
}
anxpPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique number from 1 to totalPorts that
identifies each serial port."
::= { portEntry 1 }
anxpMode OBJECT-TYPE
SYNTAX INTEGER {
cli(1),
slave(2),
adaptive(3),
unused(4),
slip(5),
dedicated(6),
ppp(7)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the mode for access to
the serial line port. The default is cli"
::= { portEntry 2 }
anxpCtrlLines OBJECT-TYPE
SYNTAX INTEGER {
none(1),
dcddtr(2),
ctsrts(3),
both(4)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of hardware control used on the port:
modem control (dcddtr), flow control (ctsrts),
or both."
::= { portEntry 3 }
anxpBidirModem OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the port is
configured for adaptive use with a bidirectional
modem."
::= { portEntry 4 }
anxpAllowBcast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether the serial port can receive
administrative broadcast messages."
::= { portEntry 5 }
anxpBcastDirection OBJECT-TYPE
SYNTAX INTEGER {
port(1),
network(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the direction that an administrative
broadcast message is sent. This parameter is
valid only when the port is defined as a slave
port by the anxpMode parameter."
::= { portEntry 6 }
anxpInputStartChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control character sequence that restarts
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff."
::= { portEntry 7 }
anxpInputStopChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control character sequence that stops
input if the charPortInFlowType parameter
(in the char MIB) is set to xonXoff."
::= { portEntry 8 }
anxpOutputStartChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control character sequence that restarts
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff."
::= { portEntry 9 }
anxpOutputStopChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The control character sequence that stops
output if the charPortOutFlowType parameter
(in the char MIB) is set to xonXoff."
::= { portEntry 10 }
anxpIxanyFlowCtl OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter specifies whether any input
character will be treated as a start (xon)
character when output has been suspended by
a stop (xoff) character."
::= { portEntry 11 }
anxpLongBreak OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break greater than two seconds."
::= { portEntry 12 }
anxpShortBreak OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
returns the user to the CLI prompt after
receiving a break shorter than two seconds."
::= { portEntry 13 }
anxpForwardTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the inter-character
timer that sets the amount of time, in tens of
milliseconds, that will elapse before
forwarding the received data. The value of
zero turns off the timer."
::= { portEntry 14 }
anxpForwardCount OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the number of received characters
buffered for the port by the Annex before
forwarding the characters to the host or
network."
::= { portEntry 15 }
anxpImask7Bits OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, instructs the Annex to ignore
the eighth bit of all received characters
on the port."
::= { portEntry 16 }
anxpAttnChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (2..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines a control character sequence as an
attention character to return the user to
the CLI prompt. The Annex-II only allows
a single control character (eg. ^A), while
the Annex3 and MicroAnnex allow a string
of control characters to be defined
(eg. ^A^B^Z)."
::= { portEntry 17 }
anxpInputBufSize OBJECT-TYPE
SYNTAX INTEGER (4..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of 256-byte blocks allocated to
receive input characters from this port."
::= { portEntry 18 }
anxpInputIsActivity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether received input characters
are considered as activity for the port."
::= { portEntry 19 }
anxpOutputIsActivity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Controls whether transmitted output characters
are considered as activity for the port."
::= { portEntry 20 }
anxpInactivityTimer OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time, in minutes, which a port
can remain inactive before the Annex terminates
all sessions and resets the port. A value of
0 disables the timer."
::= { portEntry 21 }
anxpResetIdleTimer OBJECT-TYPE
SYNTAX INTEGER {
input(1),
output(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines whether input or output resets the
idle timer for the port."
::= { portEntry 22 }
anxpCliInactivity OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time, in minutes, that the Annex
waits before hanging up the serial port after
it becomes idle. A value of 0 turns off the
timer. A value of 255 means immediate, which
causes the Annex to hang up the port immediately
after exiting from the last job."
::= { portEntry 23 }
anxpCliSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether security is
enabled for the port."
::= { portEntry 24 }
anxpConnectSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the host-based
security policy is enabled for access from the
port to the network."
::= { portEntry 25 }
anxpPortServerSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the host-based
security policy is enabled for access to the
port from the port server."
::= { portEntry 26 }
anxpPortPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines a password for the
port for local password protection."
::= { portEntry 27 }
anxpUserName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string defining the user name for the
user of the serial port."
::= { portEntry 28 }
anxpDedicatedAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When the anxpMode parameter is set to dedicated,
this parameter defines the Internet address
of the host to which this port can connect to."
::= { portEntry 29 }
anxpDedicatedPort OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The application name or TCP port number to
which this port can connect when the anxpMode
parameter is set to dedicated. The allowed
application names are 'telnet', 'rlogin',
'login', 'call', and 'mls'."
::= { portEntry 30 }
anxpPrompt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines a port-specific
prompt."
::= { portEntry 31 }
anxpTermVar OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string defining the type of terminal attached
to the serial port."
::= { portEntry 32 }
anxpNewLineTerm OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether a carriage
return is echoed as just a carriage return
(enabled), or whether the carriage return is
echoed as a carriage return and line feed."
::= { portEntry 33 }
anxpEcho OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes all characters as they are received
from the port."
::= { portEntry 34 }
anxpMapToLower OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex translates all upper
case characters to lower case as they are
received from the port."
::= { portEntry 35 }
anxpMapToUpper OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex translates all lower
case characters to upper case as they are
transmitted to the port."
::= { portEntry 36 }
anxpHardwareTabs OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, this parameter allows the Annex
to expand ASCII tab characters."
::= { portEntry 37 }
anxpCharErase OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes the character erase and word erase
characters for a video terminal (enabled)
or for a hard-copy terminal (disabled)."
::= { portEntry 38 }
anxpLineErase OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
echoes the line erase character for a video
terminal (enabled) or for a hard-copy terminal
(disabled)."
::= { portEntry 39 }
anxpEraseChar OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the character erase control character
sequence."
::= { portEntry 40 }
anxpEraseWord OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the word erase control character
sequence."
::= { portEntry 41 }
anxpEraseLine OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the line erase control character
sequence."
::= { portEntry 42 }
anxpRedisplayLine OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the reprint line control character
sequence."
::= { portEntry 43 }
anxpToggleOutput OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the flush control character used to
flush the output buffer."
::= { portEntry 44 }
anxpTelnetEscape OBJECT-TYPE
SYNTAX DisplayString (SIZE (2))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the control character that returns the
user to the telnet: prompt when running the
CLI telnet command."
::= { portEntry 45 }
anxpNeedDsr OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether the DSR signal needs to be
asserted when connecting to a slave port."
::= { portEntry 46 }
anxpTelnetCRLF OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines what characters are transmitted
out the port to the network when the
End-of-Line character is sensed. 'enabled'
means transmit Line-Feed and Carriage-Return.
'disabled' means transmit Carriage-Return
and NULL. The default is enabled."
::= {portEntry 47 }
anxpLatbEnable OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Controls interpretation of LAT Data-B packets
received from host."
::= { portEntry 48 }
anxpSlipSecure OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
"If anxEnableSecurity is not set, this
parameter selects slip session logging. If
anxEnableSecurity is set, this parameter
permits slip access only from secure ports."
::= { portEntry 49 }
anxpNetLocalAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address for the Annex's side
of the point-to-point (SLIP or PPP) link."
::= { portEntry 50 }
anxpNetRemoteAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address for the host at the
remote end of the point-to-point (SLIP or PPP)
link."
::= { portEntry 51 }
anxpSlipSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The subnet mask for this SLIP interface."
::= { portEntry 52 }
anxpSlipLoadDumpHost OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of the host from which
the Annex receives a load or to which the
Annex sends a dump over the SLIP interface."
::= { portEntry 53 }
anxpNetMetric OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the hop count to
the remote end of the SLIP or PPP interface."
::= { portEntry 54 }
anxpSlipAllowDump OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines whether the Annex is
allowed to dump across a SLIP link."
::= { portEntry 55 }
anxpSlipDoCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will start TCP/IP
header compression on this SLIP link."
::= { portEntry 56 }
anxpSlipAllowCompression OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will use TCP/IP
header compression on this SLIP link only
if the other end of the SLIP link initiates
the compression."
::= { portEntry 57 }
anxpSlipMtuSize OBJECT-TYPE
SYNTAX INTEGER {
large(1),
small(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Force the compressed SLIP interface to use
a Maximum Transmission Unit (MTU) of either
1024 bytes (large) or 256 bytes (small). The
default is large."
::= { portEntry 58 }
anxpSlipNoIcmp OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex will discard any
ICMP packets directed to this SLIP link."
::= { portEntry 59 }
anxpSlipTos OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex sends interactive
traffic over this SLIP link before any other
traffic."
::= { portEntry 60 }
anxpPppMru OBJECT-TYPE
SYNTAX INTEGER (64..1500)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the maximum receive
unit in bytes. The default value is 1500."
::= { portEntry 61 }
anxpPppAcm OBJECT-TYPE
SYNTAX DisplayString (SIZE (8..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter specifies which of the first
32 bytes (0x00, ... 0x1F) can be sent as
clear text and which need to be escaped. A
bit on in the mask indicates the character
must be escaped. The mask should be specified
as an 8 hex character string (0x1F000000 and
1F000000 are both acceptable)."
::= { portEntry 62 }
anxpPppSecurityProto OBJECT-TYPE
SYNTAX INTEGER {
none(1),
pap(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines which security protocol will be used
to authenticate the remote user. This
parameter must be set and the Annex
enable_security (anxEnableSecurity) must be
enabled before authentication is performed.
The default is none"
::= { portEntry 63 }
anxpPppUserRemote OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The username used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the username is
defined or <unset> if the username is not
defined."
::= { portEntry 64 }
anxpPppPasswdRemote OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The username used by the Annex to identify
itself if the remote PPP peer asks for
authentication. Reading this parameter
will return either <set> if the password is
defined or <unset> if the password is not
defined."
::= { portEntry 65 }
anxpLatAuthGroupVal OBJECT-TYPE
SYNTAX DisplayString (SIZE (32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This port parameter specifies which remote
group codes are accessible to a user on a
particular Annex port. Each port has its own
set of group codes."
::= { portEntry 66 }
anxpPppDialupAddr OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex requests the
PPP dialup addresses from the host-based
ACP."
::= { portEntry 67 }
anxpBanner OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies whether the Annex banner and message-
of-the-day are displayed on the port. The
default is enabled."
::= { portEntry 68 }
anxpPsHistory OBJECT-TYPE
SYNTAX INTEGER (0..32767)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies how much data to buffer on a slave
port."
::= { portEntry 69 }
anxpLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A descriptive string for a this port. This
string is displayed by the CLI who command."
::= { portEntry 70 }
anxpType OBJECT-TYPE
SYNTAX INTEGER {
dialin(1),
hardwired(2),
terminal(3),
modem(4),
printer(5)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of device attached to the port. The
default is hardwired."
::= { portEntry 71 }
anxpCliImask7 OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines whether input at the CLI is masked to
7 bitx. The default is disabled."
::= { portEntry 72 }
anxpParaPorts OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of parallel ports on this Annex."
::= { parallelport 1 }
anxpParaPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AnxpParaPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Table of parallel port parameters."
::= { parallelport 2 }
anxpParaPortEntry OBJECT-TYPE
SYNTAX AnxpParaPortEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"The Annex parallel port configuration
parameters."
INDEX { anxpParaPortIndex }
::= { anxpParaPortTable 1 }
AnxpParaPortEntry ::= SEQUENCE {
anxpParaPortIndex INTEGER,
anxpParaPortHardwareTabs INTEGER,
anxpParaPortMapToUpper INTEGER,
anxpParaPortPrinterWidth INTEGER,
anxpParaPortInterface INTEGER,
anxpParaPortSpeed INTEGER
}
anxpParaPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique number from 1 to anxpParaPorts that
identifies each parallel port."
::= { anxpParaPortEntry 1 }
anxpParaPortHardwareTabs OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
will send a tab character to the printer. If
disabled, the tab is replaced with spaces."
::= { anxpParaPortEntry 2 }
anxpParaPortMapToUpper OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When enabled, the Annex translates all lower
case characters to upper case before
transmitting the characters to the printer
port."
::= { anxpParaPortEntry 3 }
anxpParaPortPrinterWidth OBJECT-TYPE
SYNTAX INTEGER (40..132)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The defined maximum number of characters per
printer line."
::= { anxpParaPortEntry 4 }
anxpParaPortInterface OBJECT-TYPE
SYNTAX INTEGER {
centronics(1),
dataproducts(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of printer attached to the port."
::= { anxpParaPortEntry 5 }
anxpParaPortSpeed OBJECT-TYPE
SYNTAX INTEGER {
normal(1),
high-speed(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The printer speed on the Micro-Annex."
::= { anxpParaPortEntry 6 }
anxInetAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of the Annex."
::= { annexconfig 1 }
anxPrefLoadAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The preferred load address for the Annex."
::= { annexconfig 2 }
anxPrefDumpAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The preferred dump address for the Annex."
::= { annexconfig 3 }
anxLoadDumpGateway OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of a gateway used when
the preferred load or dump host is on a
different network or subnet."
::= { annexconfig 4 }
anxLoadDumpSeq OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Lists the available network interfaces and the
order that the Annex uses them when doing a
down-line load or up-line dump."
::= { annexconfig 5 }
anxLoadBcast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1), disabled(2) }
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines whether the Annex
broadcasts for the config or the motd
files if they were not found on the
preferred load host."
::= { annexconfig 6 }
anxServerCap OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines whether the Annex can act as a file
server host for another Annex. The
allowable values are 'all', 'none' (the
default), or one or more of the following
names separated by commas:
'config', 'motd', 'image'."
::= { annexconfig 7 }
anxTimeBcast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines whether the Annex
broadcasts for the time if the preferred load
host does not provide a time server."
::= { annexconfig 8 }
anxBcastAddr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address used by the Annex when
sending broadcasts."
::= { annexconfig 9 }
anxSubnetMask OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet subnet mask."
::= { annexconfig 10 }
anxAuthAgent OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex can
send an ICMP Address Mask Reply to a received
ICMP Address Mask Request."
::= { annexconfig 11 }
anxMaxVcli OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The maximum number of virtual CLI connections
allowed by the Annex at any one time. 0 means
the Annex does not allow VCLI connections. 255
allows the Annex to maintain an unlimited number
of VCLI connections."
::= { annexconfig 12 }
anxIpEncapType OBJECT-TYPE
SYNTAX INTEGER {
ethernet(1),
ieee802(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter specifies whether the Annex
encapsulates IP packets in the Ethernet format
or the IEEE 802.2/802.3 Data Link Layer format."
::= { annexconfig 13 }
anxNameServer1Type OBJECT-TYPE
SYNTAX INTEGER {
none(1),
ien116(2),
dns(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name service type used by the primary
nameserver host."
::= { annexconfig 14 }
anxNameServer1Addr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of the primary
nameserver host."
::= { annexconfig 15 }
anxNameServer2Type OBJECT-TYPE
SYNTAX INTEGER {
none(1),
ien116(2),
dns(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name service type used by the secondary
nameserver host."
::= { annexconfig 16 }
anxNameServer2Addr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of the secondary
nameserver host."
::= { annexconfig 17 }
anxNameServerBcast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
broadcasts a name server request if the
preferred name servers do not respond."
::= { annexconfig 18 }
anxRwhod OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines whether the Annex listens for RWHO
broadcasts when building its host table."
::= { annexconfig 19 }
anxMinUniqueHostNames OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines whether the Annex minimum uniqueness
feature is available."
::= { annexconfig 20 }
anxHostTableSize OBJECT-TYPE
SYNTAX INTEGER (0..251)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the number of entries in the Annex
host table. 0 indicates no host table. 251
sets no limit on the size of the table."
::= { annexconfig 21 }
anxRouted OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines whether the RIP-listener of the routing
daemon on the Annex is enabled."
::= { annexconfig 22 }
anxEnableSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
security system is enabled."
::= { annexconfig 23 }
anxPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Setting this parameter changes the Annex's
administration password. Reading this parameter
will return either <set> if the password is
defined or <unset> if the password is not
defined."
::= { annexconfig 24 }
anxSecurServer1Addr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of the primary host where
the Annex sends its security requests."
::= { annexconfig 25 }
anxSecurServer2Addr OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of the secondary host
where the Annex sends its security requests."
::= { annexconfig 26 }
anxNetTurnAround OBJECT-TYPE
SYNTAX INTEGER (1..10)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time (in seconds) that the Annex
waits for a response from a security server."
::= { annexconfig 27 }
anxSecurBcast OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
will broadcast its security requests when
neither of the preferred security servers are
available."
::= { annexconfig 28 }
anxVcliSecurity OBJECT-TYPE
SYNTAX INTEGER {
enabled(1),
disabled(2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter controls whether the Annex
performs user validation on the virtual CLI
connections."
::= { annexconfig 29 }
anxVcliPassword OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines a password used by the
Annex when setting up a virtual CLI connection."
::= { annexconfig 30 }
anxAcpKey OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..15))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the Annex's
encryption key used when exchanging messages
between the Annex and the security server."
::= { annexconfig 31 }
anxSysLogMask OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the priority levels of events logged
in the Annex syslog file.
The allowable values are 'all', 'none', or
one or more of the following level names
separated by commas:
'emergency', 'alert', 'critical', 'error',
'warning', 'notice', 'info', 'debug' "
::= { annexconfig 32 }
anxSysLogFacility OBJECT-TYPE
SYNTAX INTEGER {
loglocal0(17),
loglocal1(18),
loglocal2(19),
loglocal3(20),
loglocal4(21),
loglocal5(22),
loglocal6(23),
loglocal7(24)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the 4.3BSD syslog
facility used in logging the Annex messages."
::= { annexconfig 33 }
anxSysLogHost OBJECT-TYPE
SYNTAX IpAddress
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Internet address of the host configured to
log Annex messages."
::= { annexconfig 34 }
anxCliPrompt OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The string used by the Annex to prompt all
CLI users."
::= { annexconfig 35 }
anxMotdFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The host file name that contains the
message-of-the-day for the Annex."
::= { annexconfig 36 }
anxTftpDirName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the directory name to be prepended
to all files (boot image, motd, macros, etc.)
when booting via TFTP."
::= { annexconfig 37 }
anxTftpDumpName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The full pathname of the TFTP dump file, if any."
::= { annexconfig 38 }
anxTimeZone OBJECT-TYPE
SYNTAX INTEGER (-1200..1200)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the timezone where the Annex resides in
minutes west of GMT."
::= { annexconfig 39 }
anxDaylightSavings OBJECT-TYPE
SYNTAX INTEGER {
us(1),
australian(2),
westeuropean(3),
mideuropean(4),
easteuropean(5),
canadian(6),
british(7),
none(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the daylight savings time for the geographic
location of the Annex."
::= { annexconfig 40 }
anxLatKey OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Annex specific LAT key used to enable
or disable the LAT protocol."
::= { annexconfig 41 }
anxCircuitTimer OBJECT-TYPE
SYNTAX INTEGER (1..100)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time interval in tens of milliseconds
between the transmission of LAT packets."
::= { annexconfig 42 }
anxFacilityNum OBJECT-TYPE
SYNTAX INTEGER (0..32767)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The LAT facility number."
::= { annexconfig 43 }
anxLatGroupVal OBJECT-TYPE
SYNTAX DisplayString (SIZE (32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Annex LAT group code for permitting access
to LAT services. To access a specific LAT
service, the Annex must have at least one
enabled group code match the service's set
group codes. The Annex will not maintain any
information about unauthorized services.
The value is displayed as a string of hex
characters with each bit defining whether a
specific group is enabled or disabled."
::= { annexconfig 44 }
anxKeepAliveTimer OBJECT-TYPE
SYNTAX INTEGER (10..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time interval, in seconds, between the
transmission of identification packets during
times of network inactivity."
::= { annexconfig 45 }
anxReXmitLimit OBJECT-TYPE
SYNTAX INTEGER (4..120)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The number of times to retransmit a packet
before notifying the user of a network failure."
::= { annexconfig 46 }
anxServerName OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..16))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string of up to 16 characters used to name
the Annex in the LAT protocol."
::= { annexconfig 47 }
anxServiceLimit OBJECT-TYPE
SYNTAX INTEGER (16..2048)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter defines the upper bound on the
number of services that the Annex can maintain
in its local service table."
::= { annexconfig 48 }
anxConfigFile OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the host file that contains the alias
and menu entries."
::= { annexconfig 49 }
anxLatVcliGroupVal OBJECT-TYPE
SYNTAX DisplayString (SIZE (32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This Annex parameter specifies which remote
group codes are accessible to virtual cli users.
All virtual cli users have the same group code.
The value is displayed as a string of hex
characters with each bit defining whether a
specific group is enabled or disabled."
::= { annexconfig 50 }
anxLatQueueMax OBJECT-TYPE
SYNTAX INTEGER (0..255)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines the maximum number of host requests
(HIC's) that the Annex will save in its internal
queue when the requested resource is not
available (port busy)."
::= { annexconfig 51 }
anxLatLocation OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..32))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"A string of up to 32 characters used to
identify the location of the Annex for
the LAT protocol."
::= { annexconfig 52 }
anxDisabledModules OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..64))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Defines which selectable modules are
currently disabled. The allowable values
are 'all', 'none' or one or more of the
following names separated by commas:
'admin', 'lat', 'ppp', 'slip', 'snmp',
'nameserver', 'cli-edit'.
If this is a MicroAnnex ELS, the values
'ppp' and 'slip' are not valid."
::= { annexconfig 53 }
anxSysLogPort OBJECT-TYPE
SYNTAX INTEGER (0..64)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Specifies the Annex port number where syslog
messages are sent. If set to 0, syslog
messages are not sent to an Annex port. This
is independent of any host-based syslogging
that may be enabled. The maximum port number
allowed will depend on the highest numbered
port on the specific Annex."
::= { annexconfig 54 }
anxcBoot OBJECT-TYPE
SYNTAX INTEGER {
immediate(1),
delayed(2),
dumpboot(3),
diagnosticboot(4),
abortschedule(5),
quiet(6)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The type of boot to be performed.
To initiate a dump, this parameter needs to
be set by the management station. The values
stored in anxcBootImage, anxcBootTime, and
anxcBootMsg are used as needed, depending on
the boot type."
::= { annexcmds 1 }
anxcBootImage OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The name of the image file to be used with
the boot command."
::= { annexcmds 2 }
anxcBootTime OBJECT-TYPE
SYNTAX DisplayString (SIZE (5..10))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The time at which the next boot is scheduled
in HH:MM format."
::= { annexcmds 3 }
anxcBootMsg OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The broadcast message to be displayed when the
next boot is performed."
::= { annexcmds 4 }
anxcReset OBJECT-TYPE
SYNTAX INTEGER {
all(1),
macros(2),
motd(3),
nameserver(4),
security(5),
printerport(6),
serialports(7),
virtualports(8)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Writing a value to this object causes the
annex to reset the appropriate subsystem."
::= { annexcmds 5 }
anxcBcast OBJECT-TYPE
SYNTAX INTEGER {
all(1),
serial(2),
virtual(3)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"Writing a value to this object causes the
annex to send the message in anxcBcastMsg to the
specified port set."
::= { annexcmds 6 }
anxcBcastMsg OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..100))
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The message to be broadcast to the Annex
ports."
::= { annexcmds 7 }
END