SNMP MIB Search

Return to vendor list
View mib
Download mib file
Mib: CISCO-FABRIC-C12K-MIB
Version: 1


Objects
Scalar Object
cfcGenericGlobalFabConfigMode.1.3.6.1.4.1.9.9.281.1.1.1.1
This object gives the current bandwidth and
redundancy configuration of fabric in the system.
cfcGenericGlobalFabMasterSched.1.3.6.1.4.1.9.9.281.1.1.1.2
This object gives the entPhysicalIndex of the master
scheduler fabric card in the system. If there is no
master scheduler card then this object will return the
value zero.
cfcGenericFabToFabEntry.1.3.6.1.4.1.9.9.281.1.1.2.1.1
An entry providing various ToFabFIA statistics and
information of the associated linecard identified
by entPhysicalIndex.
cfcGenericFabFrFabEntry.1.3.6.1.4.1.9.9.281.1.1.2.2.1
An entry providing FrFabFIA information of the
associated linecard identified by entPhysicalIndex.
cfcGenericFabFrFabSliEntry.1.3.6.1.4.1.9.9.281.1.1.2.3.1
An entry providing per serial link information maintained
by the FrFabFIA on an associated linecard.
cfcGenericScaEntry.1.3.6.1.4.1.9.9.281.1.1.3.1.1
An entry providing various statistics and information
of SCA on an associated CSC identified by the
respective entPhysicalIndex.
cfcGenericXbarEntry.1.3.6.1.4.1.9.9.281.1.1.4.1.1
An entry providing Xbar information on an associated
fabric card identified by entPhysicalIndex.
cfcPreOc192FabToFabEntry.1.3.6.1.4.1.9.9.281.1.2.1.1.1
An entry providing various statistics and
counters of pre-OC192 ToFabFIA on an associated
linecard identified by entPhysicalIndex.
cfcPreOc192FabFrFabEntry.1.3.6.1.4.1.9.9.281.1.2.1.2.1
An entry providing various statistics and information
of pre-OC192 FrFabFIA on an associated linecard
identified by entPhysicalIndex.
cfcPreOc192ScaEntry.1.3.6.1.4.1.9.9.281.1.2.2.1.1
An entry providing various statistics and information
of pre-OC192 SCA on an associated CSC identified by
entPhysicalIndex.
cfcPreOc192XbarEntry.1.3.6.1.4.1.9.9.281.1.2.3.1.1
An entry providing various statistics and information
of Pre-OC192 Xbar on an associated fabric card identified
by entPhysicalIndex.
cfcOc192FabToFabEntry.1.3.6.1.4.1.9.9.281.1.3.1.1.1
An entry providing various statistics and information
of OC192 ToFabFIA on an associated linecard identified
by entPhysicalIndex.
cfcOc192FabFrFabEntry.1.3.6.1.4.1.9.9.281.1.3.1.2.1
An entry providing various statistics and information
of OC192 FrFabFIA on an associated linecard identified
by entPhysicalIndex.
cfcOc192FabFrFabSliEntry.1.3.6.1.4.1.9.9.281.1.3.1.3.1
An entry providing per serial link information maintained
by the OC192 FrFabFIA on an associated linecard identified
by entPhysicalIndex.
cfcOc192FabFrFabStatEntry.1.3.6.1.4.1.9.9.281.1.3.1.4.1
An entry providing per module statistics information
maintained by the OC192 FrFabFIA on an associated
linecard identified by entPhysicalIndex.
cfcOc192ScaEntry.1.3.6.1.4.1.9.9.281.1.3.2.1.1
An entry providing various statistics and information
of OC192 SCA on an associated CSC identified by
entPhysicalIndex.
cfcOc192XbarEntry.1.3.6.1.4.1.9.9.281.1.3.3.1.1
An entry providing various statistics and information
of OC192 Xbar on an associated fabric card identified
by entPhysicalIndex.
cfcNotifEnable.1.3.6.1.4.1.9.9.281.1.4.1
This variable indicates whether the system
produces the notifications defined in the MIB.
A false value will prevent the notifications in
the MIB from being generated by the system.
Tabular Object
cfcGenericFabToFabState.1.3.6.1.4.1.9.9.281.1.1.2.1.1.1
Indicates the current state of the ToFabFIA.
active - ToFabFIA is currently active.
On reaching a test point for the FIA errors, the
ToFabFIA will be moved to halted state.
cfcGenericFabToFabGrantPEs.1.3.6.1.4.1.9.9.281.1.1.2.1.1.2
Count of parity errors detected by the ToFabFIA
on the grant lines to SCA.
cfcGenericFabToFabRequestPEs.1.3.6.1.4.1.9.9.281.1.1.2.1.1.3
Count of parity errors detected by the ToFabFIA
on the request lines to SCA. These errors are detected
by the SCA and fed back to the ToFabFIA.
cfcGenericFabToFabCellFifoPEs.1.3.6.1.4.1.9.9.281.1.1.2.1.1.4
Count of cell parity errors detected by the ToFabFIA
while dequeuing cells from the cell fifo.
cfcGenericFabFrFabState.1.3.6.1.4.1.9.9.281.1.1.2.2.1.1
Indicates the current state of the FrFabFIA.
active - FrFabFIA is currently active.
On reaching a test point for the FIA errors, the
FrFabFIA will be moved to halted state
cfcGenericFabFrFabSliFabIndex.1.3.6.1.4.1.9.9.281.1.1.2.3.1.1
The entPhysicalIndex of the switch fabric cards (CSC/SFC)
present in the monitored system.
cfcGenericFabFrFabSliLOSErrors.1.3.6.1.4.1.9.9.281.1.1.2.3.1.2
Count of LOS errors detected by the FrFabFIA
on the serial link to the fabric card identified by
cfcGenericFabFrFabSliFabIndex.
cfcGenericFabFrFabSliCRCErrors.1.3.6.1.4.1.9.9.281.1.1.2.3.1.3
Count of CRC errors detected by the FrFabFIA
on the serial link to the fabric card identified by
cfcGenericFabFrFabSliFabIndex.
cfcGenericFabFrFabSliLOSState.1.3.6.1.4.1.9.9.281.1.1.2.3.1.4
State of LOS detection as enabled on FrFabFIA
(identified by entPhysicalIndex) for the serial link
to the switch fabric card identified by
cfcGenericFabFrFabSliFabIndex.
Value is either,
(1) losOff
(2) losOn
A losOff state normally indicates that the FrFabFIA
has detected a state of persisting LOS on the serial
link and has disabled LOS detection for that serial
link.
cfcGenericScaIdentifier.1.3.6.1.4.1.9.9.281.1.1.3.1.1.1
The vendor-specific identifier string of SCA ASIC. This
identifier generally includes the revision number and the
manufacturing part number of SCA.
cfcGenericScaIntrStatus.1.3.6.1.4.1.9.9.281.1.1.3.1.1.2
Gives the status/occurrence of different alarm conditions
in the SCA. This object is a read-clear object, that is
the value of the object is cleared on every read.
cfcGenericScaIntrsEnabled.1.3.6.1.4.1.9.9.281.1.1.3.1.1.3
Gives the list of different alarm conditions enabled to
be generated by the SCA.
cfcGenericScaConfig.1.3.6.1.4.1.9.9.281.1.1.3.1.1.4
Gives the current configuration of the SCA ASIC.
quarterBandwidth (0)       -- 1/4th of the full bandwidth
is supported per slot by
the switch.
halfBandwidth (1)          -- 1/2th of the full bandwidth
is supported per slot by
the switch.
fullBandwidth (2)          -- Full bandwidth is supported
per slot by the switch.
enableParity (3)           -- Parity handling by SCA is
enabled.
priMcast (4)               -- Priority of Multicast
requests is greater then
Unicast requests.
priUnicast (5)             -- Priority of Unicast
requests is greater then
Multicast requests.
priAlternating (6)         -- Alternate the priority
between pri-mcast and
pri-unicast modes every
cell clock.
earlyIntrOnLOS (7)         -- Cause early interrupt on
loss-of-sync error.
noEarlyIntrOnLOS (8)       -- Allow time to resync on
loss-of-sync error.
forceXbarParityXer (9)     -- Force bad parity on xbar
on every cell clock.
forceGrantParityXer (10)   -- Force bad partity on grant
to every line card.
unicastAcceptMode (11)     -- Enable unicast accept
pointer updating only on
cell periods when Unicast
has higher priority over
multicast.
forceXbarCrcOnCtlLink0 (12)-- Force CRC error on Xbar
control link 0.
forceXbarCrcOnCtlLink0 (13)-- Force CRC error on Xbar
control link 1.
forceXbarCrcOnCtlLink0 (14)-- Force CRC error on Xbar
control link 2.
forceXbarCrcOnCtlLink0 (15)-- Force CRC error on Xbar
control link 3.
cfcGenericScaPELog.1.3.6.1.4.1.9.9.281.1.1.3.1.1.5
Indicates the modules which caused the parity error and
resulted in an interrupt. The corresponding bit is set on
occurrence of parity error for a module. This object is a
read-clear object, that is the value of the object is
cleared on every read.
cfcGenericScaFifoOverflowLog.1.3.6.1.4.1.9.9.281.1.1.3.1.1.6
Indicates the modules which caused an overflow at the
request fifo and resulted in an interrupt. The
corresponding bit is set on occurrence of fifo overflow
for a module. This object is a read-clear object, that is
the value of the object is cleared on every read.
cfcGenericScaLCsEnabled.1.3.6.1.4.1.9.9.281.1.1.3.1.1.7
Indicates the modules which are present and the SCA has
been configured to start accepting requests from this
module.
cfcGenericScaForcedBackPressure.1.3.6.1.4.1.9.9.281.1.1.3.1.1.8
Indicates the linecards which exerted backpressure.
SCA will not grant Xbar connection to these linecards.
cfcGenericScaOc192LCsPresent.1.3.6.1.4.1.9.9.281.1.1.3.1.1.9
Indicates the OC192 linecards present in the monitored
system. The corresponding bit is set for each linecard
present, indicating the postion.
cfcGenericScaPreOc192LCsPresent.1.3.6.1.4.1.9.9.281.1.1.3.1.1.10
Indicates the Pre-OC192 linecards present in the
monitored system. The corresponding bit is set for
each linecard present, indicating the position.
cfcGenericXbarIdentifier.1.3.6.1.4.1.9.9.281.1.1.4.1.1.1
The vendor-specific identifier string of Xbar ASIC. This
identifier generally includes the revision number and the
manufacturing part number of Xbar.
cfcPreOc192FabToFabScaLosts.1.3.6.1.4.1.9.9.281.1.2.1.1.1.1
Indicates the number of times the ToFabFIA lost contact
with SCA(scheduler controller Asic) on master CSC.
cfcPreOc192FabToFabUCFifoOvFlws.1.3.6.1.4.1.9.9.281.1.2.1.1.1.2
Count of unicast fifo overflow errors on the ToFabFIA.
Problems between BMA/CSAR and the ToFabFIA may be one
of the reasons for these errors.
cfcPreOc192FabToFabUCFifoUnFlws.1.3.6.1.4.1.9.9.281.1.2.1.1.1.3
Count of unicast fifo underflow errors on the ToFabFIA.
These errors are caused by the SCA granting without
actually getting a request from the ToFabFIA.
cfcPreOc192FabToFabMCFifoErrs.1.3.6.1.4.1.9.9.281.1.2.1.1.1.4
Count of multicast fifo overflow and underflow errors
on the ToFabFIA. Problems between BMA/CSAR and the
ToFabFIA may be one of the reasons for multicast fifo
overflow errors. Underflow errors are caused by the SCA
granting without actually getting a request from the
ToFabFIA.
cfcPreOc192FabToFabBmaPEs.1.3.6.1.4.1.9.9.281.1.2.1.1.1.5
Count of parity errors on cells received from BMA by the
ToFabFIA.
cfcPreOc192FabToFabBmaHskErrs.1.3.6.1.4.1.9.9.281.1.2.1.1.1.6
Count of handshake errors between the BMA/CSAR and the
ToFabFIA.
cfcPreOc192FabToFabUniDestMCRqs.1.3.6.1.4.1.9.9.281.1.2.1.1.1.7
Count of requests with single destination in a multicast
request detected by ToFabFIA. The FIA will send this
cell to the destination.
cfcPreOc192FabToFabMultiDstUCRqs.1.3.6.1.4.1.9.9.281.1.2.1.1.1.8
Count of requests with multiple destinations in a unicast
request detected by a ToFabFIA. The FIA will drop this
cell.
cfcPreOc192FabToFabEmptyDestRqs.1.3.6.1.4.1.9.9.281.1.2.1.1.1.9
Count of requests with empty destination detected by
ToFabFIA. The FIA will drop this cell.
cfcPreOc192FabFrFabCellFifoPEs.1.3.6.1.4.1.9.9.281.1.2.1.2.1.1
Count of cisco cell fifo parity errors detected by the
FrFabFIA while dequeuing cells from the cell fifo.
cfcPreOc192FabFrFabRedFifoPEs.1.3.6.1.4.1.9.9.281.1.2.1.2.1.2
Count of redundant data fifo parity errors detected by
the FrFabFIA.
cfcPreOc192FabFrFabRedFifoOvflws.1.3.6.1.4.1.9.9.281.1.2.1.2.1.3
Count of redundant data fifo overflow errors detected by
the FrFabFIA. This is caused if the back pressure
is broken (i.e. the FrFabFIA exerts back pressure and the
SCA keeps giving more data to it).
cfcPreOc192FabFrFabCellDrops.1.3.6.1.4.1.9.9.281.1.2.1.2.1.4
Count of number of cells dropped by the FrFabFIA.
In case of non-redundant fabric configuration, cell drops
can occur when a parity error is detected on one or more
than one serial link. In case of redundant fabric
configuration cell drops can occur when a cell gets
corrupted on more than one serial link.
cfcPreOc192ScaReSyncDelay.1.3.6.1.4.1.9.9.281.1.2.2.1.1.1
The number of cell periods that the SCA will allow
the serial links connected to a module and Xbar to be
resynced, if a loss-of-sync has occurred on the
corresponding module. The value '0' indicates that on
occurrence of LOS, the sca will only log the LOS event
and do the scheduling for that module as normal.
cfcPreOc192ScaLOSLog.1.3.6.1.4.1.9.9.281.1.2.2.1.1.2
Indicates the LOS event occurrence on each linecard
connected to this CSC. The corresponding bit is set on
occurrence of LOS event on a line card. This object is
a read-clear object, that is the value of the object is
cleared on every read.
cfcPreOc192XbarIntrStatus.1.3.6.1.4.1.9.9.281.1.2.3.1.1.1
Indicates the occurrence of different alarm conditions in
Xbar. This object is a read-clear object, that is the
value of the object is cleared on every read.
cfcPreOc192XbarParityChkStatus.1.3.6.1.4.1.9.9.281.1.2.3.1.1.2
Indicates the parity check state in control data received
from SCA to the Xbar.
true(1) indicates that the parity check is enabled.
false(2) indicates that the parity check is disabled.
cfcOc192FabToFabMccDataPEs.1.3.6.1.4.1.9.9.281.1.3.1.1.1.1
Count of the parity errors on data lines from
MCC to ToFabFIA. This error would cause the
ToFabFIA to halt.
cfcOc192FabToFabMccCmdPEs.1.3.6.1.4.1.9.9.281.1.3.1.1.1.2
Count of the parity errors on command lines from
MCC to ToFabFIA. This error would cause the
ToFabFIA to halt.
cfcOc192FabToFabBackPressurePEs.1.3.6.1.4.1.9.9.281.1.3.1.1.1.3
Count of the parity errors on back pressure line from
FrFabFIA to ToFabFIA. This error would cause the
ToFabFIA to halt.
cfcOc192FabToFabCellFifoOvFlws.1.3.6.1.4.1.9.9.281.1.3.1.1.1.4
Count of the cell fifo overflow errors detected by the
ToFabFIA. This error would cause the ToFabFIA to halt.
cfcOc192FabToFabCellFifoUnFlws.1.3.6.1.4.1.9.9.281.1.3.1.1.1.5
Count of the cell fifo underflow errors detected by the
ToFabFIA. This error would cause the ToFabFIA to halt.
cfcOc192FabToFabMccCmdSeqEndErrs.1.3.6.1.4.1.9.9.281.1.3.1.1.1.6
Count of the illegal sequence of command errors where
a middle or start command followed by a start command
is received from MCC.
cfcOc192FabToFabMccCmdSeqStrErrs.1.3.6.1.4.1.9.9.281.1.3.1.1.1.7
Count of the illegal sequence of command errors where
an end command followed by an end or middle command
is received from MCC.
cfcOc192FabFrFabPktLenErrs.1.3.6.1.4.1.9.9.281.1.3.1.2.1.1
Count of the packets (after reassembly from Cisco
cells) which exceed the maximum permitted packet
length of FrFabFIA. These packets will be dropped.
cfcOc192FabFrFabExtRamPEs.1.3.6.1.4.1.9.9.281.1.3.1.2.1.2
Count of the parity errors detected in FrFabFIA's
external SRAM.
cfcOc192FabFrFabPktLenPEs.1.3.6.1.4.1.9.9.281.1.3.1.2.1.3
Count of the parity errors detected in payload packet
length field of the FrFabFIA's Payload Header SRAM.
cfcOc192FabFrFabHdrSramPEs.1.3.6.1.4.1.9.9.281.1.3.1.2.1.4
Count of the parity errors detected in payload header
field of the FrFabFIA's Payload Header SRAM.
cfcOc192FabFrFabTxCtrlPEs.1.3.6.1.4.1.9.9.281.1.3.1.2.1.5
Count of the parity errors detected on the Tx control
bits of FrFabFIA.
cfcOc192FabFrFabHdrFifoOvFlws.1.3.6.1.4.1.9.9.281.1.3.1.2.1.6
Count of the overflow errors in the FrFabFIA's reassembly
fifos in the on-chip payload header SRAM.
cfcOc192FabFrFabExtSramOvFlws.1.3.6.1.4.1.9.9.281.1.3.1.2.1.7
Count of the overflow errors in the FrFabFIA's reassembly
external SRAM's payload fifos.
cfcOc192FabFrFabFirstLastErrs.1.3.6.1.4.1.9.9.281.1.3.1.2.1.8
Count of the First-Last errors detected by FrFabFIA's.
If a first cell is received for a reassembly fifo, while
an earlier packet in the same reassembly fifo is still
waiting for its last cell, then it is called a First-Last
Error.
cfcOc192FabFrFabSeqErrs.1.3.6.1.4.1.9.9.281.1.3.1.2.1.9
Count of the sequence errors detected by FrFabFIA in
the cells received for reassembly. If a cell is received
whose sequence number is not an unit increment from the
previous cell of the same packet then it is a sequence
error.
cfcOc192FabFrFabSliSwitchIndex.1.3.6.1.4.1.9.9.281.1.3.1.3.1.1
The entPhysicalIndex of the switch fabric cards (CSC/SFC)
present in the monitored system.
cfcOc192FabFrFabSliXorErrs.1.3.6.1.4.1.9.9.281.1.3.1.3.1.2
Count of the XOR check errors detected by FrFabFIA
reassembly. The data paths are horizontally XORed and
the result is expected to match the contents of the
redundant path else it is counted as XOR error, this
error applies only in redundant mode of fabric.
cfcOc192FabFrFabSliCellDrops.1.3.6.1.4.1.9.9.281.1.3.1.3.1.3
Count of the total cells dropped by the FrFabFIA from
the fabric card due to uncorrectable errors. Uncorrectable
errors are the errors other than CRC, LOS, Horizontal XOR
and idle cell which cannot be corrected.
cfcOc192FabFrFabStatLCIndex.1.3.6.1.4.1.9.9.281.1.3.1.4.1.1
The entPhysicalIndex of the Line card present in the
monitored system.
cfcOc192FabFrFabStatUCHiPktDrops.1.3.6.1.4.1.9.9.281.1.3.1.4.1.2
Count of Unicast high priority packets dropped, from
source module indicated by cfcOc192FabFrFabStatLCIndex.
cfcOc192FabFrFabStatUCLoPktDrops.1.3.6.1.4.1.9.9.281.1.3.1.4.1.3
Count of Unicast low priority packets dropped, from
source module indicated by cfcOc192FabFrFabStatLCIndex.
cfcOc192FabFrFabStatMCHiPktDrops.1.3.6.1.4.1.9.9.281.1.3.1.4.1.4
Count of Multicast high priority packets dropped, from
source module indicated by cfcOc192FabFrFabStatLCIndex.
cfcOc192FabFrFabStatMCLoPktDrops.1.3.6.1.4.1.9.9.281.1.3.1.4.1.5
Count of Multicast low priority packets dropped, from
source module indicated by cfcOc192FabFrFabStatLCIndex.
cfcOc192ScaRotationPeriod.1.3.6.1.4.1.9.9.281.1.3.2.1.1.1
Determines the period of rotating the priority between
Unicast and Multicast, in cell periods, when the SCA is
configured with alternating priority mode.
For example, if the value of this object is 63 then
the priority will change every 64 cell periods, if the
value is 0 then the priority will change every cell
period.
cfcOc192ScaDisableGrants.1.3.6.1.4.1.9.9.281.1.3.2.1.1.2
Indicates the disable of grants by SCA to any requests
coming from a specific module. The corresponding bit
is set for each module.
cfcOc192XbarCtrlLOSStatus.1.3.6.1.4.1.9.9.281.1.3.3.1.1.1
Indicates the occurrence of LOS errors on the control path
of Xbar.
frameLosErr (0)               -- Frame LOS error.
sliErrorOnControlLink0 (1)    -- LOS detected on SLI
control link 0.
sliErrorOnControlLink1 (2)    -- LOS detected on SLI
control link 1.
sliErrorOnControlLink2 (3)    -- LOS detected on SLI
control link 2.
sliErrorOnControlLink3 (4)    -- LOS detected on SLI
control link 3.
This object is a read-clear object, that is the value
of the object is cleared on every read.
cfcOc192XbarCtrlCRCErr.1.3.6.1.4.1.9.9.281.1.3.3.1.1.2
Indicates the occurrence of CRC error on any of the
four control links. This object is a read-clear object,
that is the value of the object is cleared on every read.
Table
cfcGenericFabToFabTable.1.3.6.1.4.1.9.9.281.1.1.2.1
A table providing ToFabFIA statistics and
information in the managed system.
cfcGenericFabFrFabTable.1.3.6.1.4.1.9.9.281.1.1.2.2
A table providing FrFabFIA information in the
managed system.
cfcGenericFabFrFabSliTable.1.3.6.1.4.1.9.9.281.1.1.2.3
A table providing per serial link information maintained
by the FrFabFIA in the managed system.
cfcGenericScaTable.1.3.6.1.4.1.9.9.281.1.1.3.1
A table providing SCA statistics and information in
the managed system.
cfcGenericXbarTable.1.3.6.1.4.1.9.9.281.1.1.4.1
A table providing Xbar information in the
managed system.
cfcPreOc192FabToFabTable.1.3.6.1.4.1.9.9.281.1.2.1.1
A table providing pre-OC192 ToFabFIA statistics and
information in the managed system.
cfcPreOc192FabFrFabTable.1.3.6.1.4.1.9.9.281.1.2.1.2
A table providing pre-OC192 FrFabFIA statistics and
information in the managed system.
cfcPreOc192ScaTable.1.3.6.1.4.1.9.9.281.1.2.2.1
A table providing pre-OC192 SCA statistics and
information in the managed system.
cfcPreOc192XbarTable.1.3.6.1.4.1.9.9.281.1.2.3.1
A table providing Pre-OC192 Xbar statistics and
information in the managed system.
cfcOc192FabToFabTable.1.3.6.1.4.1.9.9.281.1.3.1.1
A table providing OC192 ToFabFIA statistics
and information in the managed system.
cfcOc192FabFrFabTable.1.3.6.1.4.1.9.9.281.1.3.1.2
A table providing FrFabFIA statistics and
information in the managed system.
cfcOc192FabFrFabSliTable.1.3.6.1.4.1.9.9.281.1.3.1.3
A table providing per serial link information maintained
by the OC192 FrFabFIA in the managed system.
cfcOc192FabFrFabStatTable.1.3.6.1.4.1.9.9.281.1.3.1.4
A table providing per module statistics information
maintained by the OC192 FrFabFIA in the managed system.
cfcOc192ScaTable.1.3.6.1.4.1.9.9.281.1.3.2.1
A table providing OC192 SCA statistics and information in
the managed system.
cfcOc192XbarTable.1.3.6.1.4.1.9.9.281.1.3.3.1
A table providing OC192 Xbar statistics and information
in the managed system.
Trap
ciscoFabricC12kMIBFabMasterSchCh.1.3.6.1.4.1.9.9.281.0.1
This notification is generated when master scheduler
on the system changes. It typically indicates the
switchover of the scheduler card.
cfcGenericGlobalFabMasterSched represents the
entPhysicalIndex of the new master scheduler card,
while entPhysicalName represents the entity physical
name of the card. The case of all scheduler cards going
down would be represented by a value 0 for the
cfcGenericGlobalFabMasterSched and noSuchInstance for the
entPhysicalName.
Object Identifier
ciscoFabricC12kMIB.1.3.6.1.4.1.9.9.281
Cisco Fabric MIB module for c12000 series of routers.
This MIB module is used for managing/tracking the c12000
fabric entities and fabric related configuration, status
and statistics information.
C12000 fabric architecture is based on NxN non-blocking
crossbar switch fabric, where N stands for the maximum
number of LCs that can be supported in the chassis (this
includes the RP). The connections through the switch
fabric is controlled by a scheduler (CSC), the CSC
accepts transmission requests from line cards, issues
grants to access the fabric, and provides a reference
clock to all the cards in the system to synchronize data
transfer across the crossbar.
Some of the error status objects in the MIB are read-clear,
that is the value of the object is cleared on a query of the
object.
Details about the various fabric related attributes
specified in the MIB could be found at following link,
http://www.cisco.com/warp/public/108/hwts_12000_22281.html
Acronyms and terms used in the MIB module:
GSR           - Gigabit Switch Router.
RP            - Route Processor.
LC            - Line Card.
SFC           - Switch Fabric Card.
CRC           - Cyclic Redundancy Check.
CSC           - Clock Scheduler Card.
CiscoCell     - The unit of data that is exchanged
between line cards through the switch
fabric.
FIA           - Fabric Interface Asic, this Asic
resides on the line card and is
used to interface line card and
switch fabric.
ToFabFIA      - Represents the ToFabric FIA, FIA
which transmits data from the
line card to the fabric.
FrFabFIA      - Represents the From Fabric FIA, FIA
which receives data from the fabric.
SCA           - Scheduler Control Asic, this Asic
resides on each CSC and is used to
arbitrate among the line card
requests to transmit CiscoCells
through the switch fabric.
Xbar          - Crossbar Switch Asic, this Asic
resides on each fabric card and provides
the functionality of a crossbar
switch.
SLI           - Serial Link interface block, this
block resides on the FIA on the line
cards and the Xbar and SCA on the
switch fabric. The functionality of SLI
is to interface the linecards and fabric
cards.
BMA           - Buffer Manager Asic, this Asic is
located on a Pre OC-192 linecard.
It provides the packet buffering
and buffer queue management.
MCC           - Memory Communication Controller Asic,
this Asic is located on a OC-192
linecard and is an enhanced packet buffer
Asic. MCC captures the data and control
path information for packets destined
to all line cards in the system. On the
receive side MCC interfaces with the
Rx Asic where the packets are looked up
and sent to the MCC for buffering. On the
transmit side it interfaces with the
ToFabFIA where packets arrived from MCC
will be segmented into CiscoCells before
being sent across the fabric.
CSAR          - Cisco Cell Segmentation And Reassembly,
The name of an FPGA used on the RP which
handles traffic between the processor
and switch fabric.
Request       - A signal sent by a FIA (on a line card)
to the SCA (on Master CSC) requesting a
switch connection to a output linecard as an
intent to transmit CiscoCells across.
Grant         - A signal sent by the SCA to a FIA (on a
line card) granting a switch connection which
was requested by the FIA.
SRAM          - Static Random Access Memory.
LOS           - Loss Of Signal.
FPGA          - Field Programmable Gate Array.
ciscoFabricC12kMIBNotifs.1.3.6.1.4.1.9.9.281.0
ciscoFabricC12kMIBObjects.1.3.6.1.4.1.9.9.281.1
ciscoFabricC12kMIBConform.1.3.6.1.4.1.9.9.281.2
cfcGeneric.1.3.6.1.4.1.9.9.281.1.1
cfcGenericGlobal.1.3.6.1.4.1.9.9.281.1.1.1
cfcGenericFab.1.3.6.1.4.1.9.9.281.1.1.2
cfcGenericSca.1.3.6.1.4.1.9.9.281.1.1.3
cfcGenericXbar.1.3.6.1.4.1.9.9.281.1.1.4
cfcPreOc192.1.3.6.1.4.1.9.9.281.1.2
cfcPreOc192Fab.1.3.6.1.4.1.9.9.281.1.2.1
cfcPreOc192Sca.1.3.6.1.4.1.9.9.281.1.2.2
cfcPreOc192Xbar.1.3.6.1.4.1.9.9.281.1.2.3
cfcOc192.1.3.6.1.4.1.9.9.281.1.3
cfcOc192Fab.1.3.6.1.4.1.9.9.281.1.3.1
cfcOc192Sca.1.3.6.1.4.1.9.9.281.1.3.2
cfcOc192Xbar.1.3.6.1.4.1.9.9.281.1.3.3
cfcNotif.1.3.6.1.4.1.9.9.281.1.4
ciscoFabricC12kMIBCompliances.1.3.6.1.4.1.9.9.281.2.1
ciscoFabricC12kMIBGroups.1.3.6.1.4.1.9.9.281.2.2
Group
ciscoFabricC12kGlobalGroup.1.3.6.1.4.1.9.9.281.2.2.1
A collection of Global fabric configuration
objects.
ciscoFabricC12kFiaGroup.1.3.6.1.4.1.9.9.281.2.2.2
A collection of generic FIA status and statistics
objects.
ciscoFabricC12kScaGroup.1.3.6.1.4.1.9.9.281.2.2.3
A collection of generic SCA status objects.
ciscoFabricC12kXbarGroup.1.3.6.1.4.1.9.9.281.2.2.4
A collection of generic Xbar status objects.
ciscoFabricC12kPreOc192FiaGroup.1.3.6.1.4.1.9.9.281.2.2.5
A collection of pre-OC192 FIA status and statistics
objects.
ciscoFabricC12kNotifEnableGroup.1.3.6.1.4.1.9.9.281.2.2.12
The collection of objects which are used to
control generation of notification.
ciscoFabricC12kNotifGroup.1.3.6.1.4.1.9.9.281.2.2.13
A collection of notifications generated by
the devices supporting this MIB.
ciscoFabricC12kPreOc192ScaGroup.1.3.6.1.4.1.9.9.281.2.2.6
A collection of Pre-OC192 SCA status objects.
ciscoFabricC12kPreOc192XbarGroup.1.3.6.1.4.1.9.9.281.2.2.7
A collection of Pre-Oc192 Xbar status objects.
ciscoFabricC12kOc192FiaGroup.1.3.6.1.4.1.9.9.281.2.2.8
A collection of OC192 FIA status and statistics
objects.
ciscoFabricC12kOc192LCGroup.1.3.6.1.4.1.9.9.281.2.2.9
A collection of OC192 linecard generic objects.
ciscoFabricC12kOc192ScaGroup.1.3.6.1.4.1.9.9.281.2.2.10
A collection of OC192 SCA status objects.
ciscoFabricC12kOc192XbarGroup.1.3.6.1.4.1.9.9.281.2.2.11
A collection of OC192 Xbar status objects.
Copyright (c) Tandem Systems, Ltd., 2002-2011