SNMP MIB Search

Return to vendor list
View mib
Download mib file
Mib: CISCO-OPTICAL-MONITORING-MIB
Version: 1


Objects
Scalar Object
comParametersEntry.1.3.6.1.4.1.9.10.83.1.1.1.1
Only the ifIndices of optical interfaces
whose parameters need to be monitored will
be used to index this table.
Tabular Object
comTxBiasCurrent.1.3.6.1.4.1.9.10.83.1.1.1.1.1
This  holds the value of the laser diode forward
bias current for the interface being instrumented,
and is an indication of the Tx optical power.
comTxPowerSupported.1.3.6.1.4.1.9.10.83.1.1.1.1.2
Boolean to indicate if the interface being instrumented
supports comTxPower. comTxPowerSupported is set to true
if the interface supports the comTxPower object, and set
to false otherwise.
comTxPower.1.3.6.1.4.1.9.10.83.1.1.1.1.3
This object holds the value of the transmitter optical
power for the interface being instrumented. The optical
is proportional to the laser diode current. This object
makes sense only if comTxPowerSupported is true. All
values must be converted to microWatts.
comTxLaserTempSupported.1.3.6.1.4.1.9.10.83.1.1.1.1.4
Boolean to indicate if the interface being instrumented
supports comTxLaserTemp. comTxLaserTempSupported is set
to true if the interface supports the comTxLaserTemp
object, and set to false otherwise.
comTxLaserTemp.1.3.6.1.4.1.9.10.83.1.1.1.1.5
This object holds the value of the transmitter laser
diode temperature for the interface being instrumented.
This object indicates the health of the transmitter.
comRxPowerACDC.1.3.6.1.4.1.9.10.83.1.1.1.1.6
This object holds the value of the total power
(AC + DC) at the optical  Rx of the interface.
All values must be converted to microWatts.
comRxPowerACSupported.1.3.6.1.4.1.9.10.83.1.1.1.1.7
Boolean to indicate if comRxPowerAC is supported by
the interface being instrumented. comRxPowerACSupported
is set to true if the interface supports the comRxPowerAC
object,and set to false otherwise.
comRxPowerAC.1.3.6.1.4.1.9.10.83.1.1.1.1.8
This object holds the value of the AC power at
the optical Receiver of the interface. Not all
interfaces support this object.This object makes
sense only if comRxPowerACSupported is true. All
values must be converted to microWatts.
Table
comParametersTable.1.3.6.1.4.1.9.10.83.1.1.1
This table lists the instrumented parameters of all
interfaces on the network element whose optical
parameters are to be monitored.
Object Identifier
ciscoOpticalMonitoringMIB.1.3.6.1.4.1.9.10.83
This MIB module is used to monitor optical parameters
of a network element.This MIB deals with the operating
parameters of the optical layer. The optical layer is a
term that defines all the devices/systems that deal with
the conversion of data in it's electrical form to optical
form, transmission of the optical data, reception, and
finally re-conversion to electrical signals.
ciscoOpticalMonMIBObjects.1.3.6.1.4.1.9.10.83.1
comParameters.1.3.6.1.4.1.9.10.83.1.1
ciscoOpticalMonMIBNotifPrefix.1.3.6.1.4.1.9.10.83.2
ciscoOpticalMonMIBNotifications.1.3.6.1.4.1.9.10.83.2.0
ciscoOpticalMonMIBConformance.1.3.6.1.4.1.9.10.83.3
ciscoOpticalMonMIBCompliances.1.3.6.1.4.1.9.10.83.3.1
ciscoOpticalMonMIBGroups.1.3.6.1.4.1.9.10.83.3.2
Group
ciscoOpticalMonMIBParamGroup.1.3.6.1.4.1.9.10.83.3.2.1
Parameters of the optical interfaces.
Copyright (c) Tandem Systems, Ltd., 2002-2011