SNMP MIB Search

Return to vendor list
View mib
Download mib file
Mib: CISCO-WWNMGR-MIB
Version: 1


Objects
Scalar Object
wwnmSecondaryBaseMacAddress.1.3.6.1.4.1.9.9.286.1.1.1
The first MAC address used for generating World Wide
Names (WWNs) when the default range of WWNs generated
from supervisor MAC address are exhausted.
wwnmSecondaryMacAddressRange.1.3.6.1.4.1.9.9.286.1.1.2
The number of secondary MAC Addresses starting from
and including the wwnmSecondayBaseMacAddress.
wwnmType1MaxWwns.1.3.6.1.4.1.9.9.286.1.1.3
Maximum number of NAA Type 1 WWNs that are available
for assignment to internal entities.
wwnmType1AvailableWwns.1.3.6.1.4.1.9.9.286.1.1.4
Number of NAA Type 1 WWNs that are currently
available for assignment to internal entities.
wwnmTypeOtherMaxWwns.1.3.6.1.4.1.9.9.286.1.1.5
Maximum number of total WWNs of types NAA Type 2
and Type 5 WWNs available for assignment to  internal
entities.
wwnmTypeOtherAvailableWwns.1.3.6.1.4.1.9.9.286.1.1.6
Sum of number of NAA Type 2 and Type 5 WWNs currently
available for assignment to the internal entities.
wwnmType1ReservedWwns.1.3.6.1.4.1.9.9.286.1.1.7
Number of NAA Type 1 WWNs that are reserved
for internal purposes.
wwnmTypeOtherReservedWwns.1.3.6.1.4.1.9.9.286.1.1.8
Number of total WWNs of types NAA Type 2
and Type 5 WWNs reserved for internal purposes.
Trap
wwnmType1WwnShortageNotify.1.3.6.1.4.1.9.9.286.1.2.1.0.1
A WWN shortage notification is generated whenever the
number of available Type 1 WWNs 'wwnmType1AvailableWwns'
reduces to either 20% or 10% or 0% of the maximum number
of Type 1 WWNs 'wwnmType1MaxWwns'.
After a shortage event is generated for a threshhold
(say 20%), another such event will not be generated until
after an availability event (see
wwnmType1WwnAvailableNotify) is generated for the same
threshold.
wwnmType1WwnAvailableNotify.1.3.6.1.4.1.9.9.286.1.2.1.0.2
An availability notification is generated whenever
the number of available Type 1 WWNs
(wwnmType1AvailableWwns) increases to either 25% or 15%
or 5% of the maximum number of Type 1 WWNs
(wwnmType1MaxWwns) after a wwnmType1WwnShortageNotify
notification has been generated for either 20% or 10%
or 5% respectively.
wwnmTypeOtherWwnShortageNotify.1.3.6.1.4.1.9.9.286.1.2.1.0.3
A WWN shortage notification is generated whenever the
number of available Type Other WWNs
'wwnmTypeOtherAvailableWwns' reduces to either 20% or
10% or 0% of the maximum number of Type Other WWNs
'wwnmTypeOtherMaxWwns'.
After a shortage event is generated for a threshhold
(say 20%), another such event will not be generated until
after an availability event (see
wwnmType1WwnAvailableNotify) is generated for the same
threshold.
wwnmTypeOtherWwnAvailableNotify.1.3.6.1.4.1.9.9.286.1.2.1.0.4
An availability notification is generated whenever
the number of available Type Other WWNs
(wwnmTypeOtherAvailableWwns) increases to either 25%
or 15% or 5% of the maximum number of Type Other WWNs
(wwnmTypeOtherMaxWwns) after a
wwnmTypeOtherWwnShortageNotify notification has been
generated for either 20% or 10% or 5% respectively.
Object Identifier
ciscoWwnmgrMIB.1.3.6.1.4.1.9.9.286
MIB module for WWN Manager related management
functionalities.
ciscoWwnmMIBObjects.1.3.6.1.4.1.9.9.286.1
wwnmConfigurationGroup.1.3.6.1.4.1.9.9.286.1.1
wwnmNotificationGroup.1.3.6.1.4.1.9.9.286.1.2
wwnmNotification.1.3.6.1.4.1.9.9.286.1.2.1
wwnmNotificationPrefix.1.3.6.1.4.1.9.9.286.1.2.1.0
ciscoWwnmMIBConformance.1.3.6.1.4.1.9.9.286.2
ciscoWwnmMIBCompliances.1.3.6.1.4.1.9.9.286.2.1
ciscoWwnmMIBGroups.1.3.6.1.4.1.9.9.286.2.2
Group
cwmWwnmConfigurationGroup.1.3.6.1.4.1.9.9.286.2.2.6
A collection of objects for WWN Manager.
cwmWwnmNotificationGroup.1.3.6.1.4.1.9.9.286.2.2.8
A collection of notifications for the
WWN assignment.
Copyright (c) Tandem Systems, Ltd., 2002-2012