SNMP MIB Search

   Sample: altiga stat   Advanced Search
Donate your MIB  
Search:   
   
 
Return to vendor list
View mib
Download mib file
Mib: OLD-CISCO-ENV-MIB
Version: 1


Objects
Scalar Object
envPresent.1.3.6.1.4.1.9.2.1.77
Is there an environmental monitor card in
this box?, 0 - No, 1-AGS card present, wrong
firmware, 2-AGS CARD present, firmware ok,
3-7000 support
envTestPt1Descr.1.3.6.1.4.1.9.2.1.78
Description of the test point 1. Typically
ambient air or the temperature of air
entering the router
envTestPt1Measure.1.3.6.1.4.1.9.2.1.79
Current value of test point 1. Typically a
temperature in centigrade.
envTestPt2Descr.1.3.6.1.4.1.9.2.1.80
Description of the test point 2. Typically
airflow or the temperature of air leaving the
router
envTestPt2Measure.1.3.6.1.4.1.9.2.1.81
Current value of test point 2. Typically a
temperature in centigrade.
envTestPt3Descr.1.3.6.1.4.1.9.2.1.82
Description of the test point 3. Typically
+5 volt
envTestPt3Measure.1.3.6.1.4.1.9.2.1.83
Current value of test point 3. Typically the
value in millivolts of the +5v supply
envTestPt4Descr.1.3.6.1.4.1.9.2.1.84
Description of the test point 4. Typically
+12 volt
envTestPt4Measure.1.3.6.1.4.1.9.2.1.85
Current value of test point 4. Typically the
value in millivolts of the +12v supply
envTestPt5Descr.1.3.6.1.4.1.9.2.1.86
Description of the test point 5. Typically
-12 volt
envTestPt5Measure.1.3.6.1.4.1.9.2.1.87
Current value of test point 5. Typically the
value in millivolts of the -12v supply
envTestPt6Descr.1.3.6.1.4.1.9.2.1.88
Description of the test point 6. Typically
-5 volt
envTestPt6Measure.1.3.6.1.4.1.9.2.1.89
Current value of test point 6. Typically the
value in millivolts of the -5v supply
envTestPt1MarginVal.1.3.6.1.4.1.9.2.1.90
Value at which the router will shutdown.
Typically the ambient air temperature that
will shut the router down. (e.g. 43)
envTestPt2MarginVal.1.3.6.1.4.1.9.2.1.91
Value at which the router will shutdown.
Typically the airflow air temperature that
will shut the router down. (e.g. 58)
envTestPt3MarginPercent.1.3.6.1.4.1.9.2.1.92
+/- Percentage that will shut the router
down, (e.g. 10%) typically +5 volt
envTestPt4MarginPercent.1.3.6.1.4.1.9.2.1.93
+/- Percentage that will shut the router
down, (e.g. 15%) typically +12 volt
envTestPt5MarginPercent.1.3.6.1.4.1.9.2.1.94
+/- Percentage that will shut the router
down, (e.g. 15%) typically -12 volt
envTestPt6MarginPercent.1.3.6.1.4.1.9.2.1.95
+/- Percentage that will shut the router
down, (e.g. 10%) typically -5 volt
envTestPt1last.1.3.6.1.4.1.9.2.1.96
Value of TestPt1 when last shutdown
occurred.
envTestPt2last.1.3.6.1.4.1.9.2.1.97
Value of TestPt2 when last shutdown
occurred.
envTestPt3last.1.3.6.1.4.1.9.2.1.98
Value of TestPt3 when last shutdown
occurred.
envTestPt4last.1.3.6.1.4.1.9.2.1.99
Value of TestPt4 when last shutdown
occurred.
envTestPt5last.1.3.6.1.4.1.9.2.1.100
Value of TestPt5 when last shutdown
occurred.
envTestPt6last.1.3.6.1.4.1.9.2.1.101
Value of TestPt6 when last shutdown
occurred.
envTestPt1warn.1.3.6.1.4.1.9.2.1.102
Is this test point at a warning level?
envTestPt2warn.1.3.6.1.4.1.9.2.1.103
Is this test point at a warning level?
envTestPt3warn.1.3.6.1.4.1.9.2.1.104
Is this test point at a warning level?
envTestPt4warn.1.3.6.1.4.1.9.2.1.105
Is this test point at a warning level?
envTestPt5warn.1.3.6.1.4.1.9.2.1.106
Is this test point at a warning level?
envTestPt6warn.1.3.6.1.4.1.9.2.1.107
Is this test point at a warning level?
envFirmVersion.1.3.6.1.4.1.9.2.1.108
Description of Environmental Card firmware
envTechnicianID.1.3.6.1.4.1.9.2.1.109
Technician ID
envType.1.3.6.1.4.1.9.2.1.110
The type of environmental card
envBurnDate.1.3.6.1.4.1.9.2.1.111
The calibration / burn in date
envSerialNumber.1.3.6.1.4.1.9.2.1.112
Serial Number of environmental monitor card
Object Identifier
lenv.1.3.6.1.4.1.9.2.1
Copyright (c) Tandem Systems, Ltd., 2002-2008